• Title/Summary/Keyword: 비내진 설계

Search Result 15,044, Processing Time 0.04 seconds

Deformation Based Seismic Design of Asymmetric Wall Structures (변형에 기초한 비대칭 벽식 주초의 내진설계)

  • 홍성걸;조봉호
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.43-53
    • /
    • 2002
  • Current torsional provisions focus n restricting torsional effect of asymmetric wall structures by proportioning strength of wall based on the traditional assumption that stiffness and strength are independent. Recent studies have pointed out that stiffness of structural wall is dependent on the strength. This implies that actual stiffness of walls can be determined only after torsional design is finished and current torsional provisions may result in significant errors. To overcome this shortcoming, this paper proposes deformation based torsional design for asymmetric wall structures. Contrary to the current torsional provisions, deformation-based torsional design uses displacement and rotation angle as design parameters and calculates base shear for inelastic torsional response directly. Main purpose of deformation based torsional design is not to restrict torsional response but to ensure intended torsional mechanism according to the capacity design concept. Because displacement and rotation angle can be used as performance criteria indicating performance level of asymmetric structures, this method can be applied to the performance based seismic design effectively.

Direct Inelastic Design for Steel Structures (강구조를 위한 직접비탄성설계법)

  • Eom, Tae Sung;Park, Hong Gun
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.2 s.69
    • /
    • pp.181-190
    • /
    • 2004
  • A new inelastic design method performing iterative calculations using secant stiffness was developed. Since the proposed design method uses linear analysis, it is convenient and stable in numerical analysis. At the same time, the proposed design method can accurately estimate the inelastic strength and ductility demands of the members by performing iterative calculation. In the present study, the procedure of the proposed design method was established. Design examples using the proposed method were presented, and its advantages were highlighted by comparisons with existing design methods using elastic or plastic analysis. Unlike the existing inelastic design methods performing the preliminary design on the structure and checking its validity using nonlinear analysis, the proposed integrated analysis-design method can directly calculate the strength and ductility demands of each member. In addition, the proposed design method can address the inelastic design strategy intended by the engineer, such as strength and ductility limits of members and the design concept of strong-column and weak-beam. As a result, economical and safe design can be achieved.

A Comparative Study of LRFD Methods Using Linear Elastic and Nonlinear Inelastic Analysis (선형탄성해석 및 비선형비탄성해석을 이용한 LRFD 설계법의 비교 연구)

  • Jang, Eun Seok;Park, Jung Woong;Kim, Seung Eock
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.6
    • /
    • pp.633-642
    • /
    • 2007
  • Although the Load and Resistance Factor Design (LRFD) method is an advanced design approach, it does not accurately capture the interaction between individual members and structural system. A nonlinear inelastic analysis for the entire structure is required to solve this problem. According to many design codes of advanced countries, a nonlinear inelastic analysis can be applied to predict the structural behavior and strength reasonably. In this study, an LRFD design method using practical nonlinear inelastic analysis was proposed. Design examples using the proposed method waspresented, and the economical efficiency and adequacy of the proposed method was investigated by comparing the design results with that of the AISC-LRFD. It has been consequently demonstrated that the proposed method can reduce the construction cost through savings in steel.

Asynchronous Circuit and System Design (비동기 회로 및 시스템 설계)

  • Park, Y.S.;Park, I.H.
    • Electronics and Telecommunications Trends
    • /
    • v.13 no.1 s.49
    • /
    • pp.41-51
    • /
    • 1998
  • 전역 클럭을 사용하는 동기 회로 설계 기술은 설계의 단순화 및 자동화가 용이하기 때문에 현재 많이 사용하는 설계 기술이다. 그러나 다양한 기능과 고성능을 필요로 하는 대규모 시스템이나 회로 설계에서는 전역 클럭 사용으로 인한 신호 지연, 전력 소모 등이 문제로 부각되면서 비동기 회로 설계 기술이 각광을 받고 있다. 비동기 회로 설계 기술은 1940년대에 개발된 기술이지만 설계 자체가 어렵고 면적 증가 등의 단점으로 제한된 분야에서 이용되었다. 현재 이러한 단점을 극복하기 위한 연구가 회로 설계, 검증, 동기/비동기 인터페이스, 그리고 저전력 회로 등의 분야에서 많이 진행되고 있다.

Preliminary Study on Nonlinear Static Response Topology Optimization Using Equivalent Load (등가하중을 이용한 비선형 정적 응답 위상최적설계의 기초연구)

  • Lee, Hyun-Ah;Zeshan, Ahmad;Park, Gyung-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.12
    • /
    • pp.1811-1820
    • /
    • 2010
  • Most components in the real world show nonlinear response. The nonlinearity may arise because of contact between the parts, nonlinear material, or large deformation of the components. Structural optimization considering nonlinearities is fairly expensive because sensitivity information is difficult to calculate. To overcome this difficulty, the equivalent load method was proposed for nonlinear response optimization. This method was originally developed for size and shape optimization. In this study, the equivalent load method is modified to perform topology optimization considering all kinds of nonlinearities. Equivalent load is defined as the load for linear analysis that generates the same response field as that for nonlinear analysis. A simple example demonstrates that results of the topology optimization using equivalent load are very similar to the numerical results. Nonlinear response topology optimization is performed with a practical example and the results are compared with those of conventional linear response topology optimization.

Seismic Performance Evaluation of Special Moment Steel Frames with Torsional Irregularities - II Improving Seismic Design Method (비틀림 비정형을 갖는 철골특수모멘트골조의 내진성능평가 - II 내진설계 방법개선)

  • Han, Sang Whan;Kim, Tae O
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.5
    • /
    • pp.369-376
    • /
    • 2017
  • This paper is the sequel of a companion paper (I. Seismic Design) for design and assessment of the torsional irregular structure using ASCE 7-10 criteria. This study evaluates the influence of torsional provisions on the performance of the designed steel moment frame with different eccentricity, taking the collapse probability as performance metric using the methodology in FEMA P695. The result show that torsional irregular structure designed according to ASCE 7-10 has an excessive seismic performance and the collapse strength is low as the eccentricity increases. To make the design reasonable, a new design approach is proposed in this study.

Design of a Low-rise RC Building with Damping System (저층 철근콘크리트 건축물의 제진 구조 설계)

  • Lee, Eun-Jin;Hyoun, Chang-Kook;Choi, Ki-Sun;You, Young-Chan
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.454-457
    • /
    • 2011
  • 본 논문에서는 국내에서 아직 기준이 마련되지 않은 제진설계에 대한 접근을 소개하였다. ASCE 7-05 기준에 근거하여 국내 5층 규모의 철근콘크리트 신축 건물에 제진 설계를 수행하였다. 우리나라의 현행 기준을 만족하면서 효과적인 제진 시스템 설계를 위한 방법을 소개한다. ASCE 7-05 기준에서는 제진 구조물 해석 시 부재력이 공칭강도의 1.5배를 초과하지 않은 경우 경계비선형 해석을 허용하고 있다. 이 때의 제진 설계 프로세스는 기존의 중력하중 및 등가정적하중의 75%에 의한 단면을 가정하여 부재설계를 실시하고, 선형 시간이력 해석을 통해 제진장치 및 가새를 설계한다. 이후 우리나라 실정에 맞도록 보정된 인공 지진파를 입력하여 경계비선형 해석을 실시하고, 밑면 전단력 및 층간변위 등의 만족여부를 검토한다. 이 때 목표성능을 완전탄성설계 또는 유사탄성설계로 정하여 목표성능을 만족하는지도 검토하여야 한다. 본 논문에 적용한 신축 건물은 유사탄성 설계를 위해 경계비선형 해석을 실시하였고, 가장 효과적인 제진 설계를 위해 댐퍼의 종류, 설치방법, 개수, 변위 증폭비 등을 변수로 한 case study를 진행하였다. 해석 결과 목표성능을 만족하는 범위 내에서 가장 효과적인 제진 설계는 점성댐퍼, 이층 토글형태, 증폭비 2.0, 총 8개의 댐퍼를 설치하는 것으로 나타났다.

  • PDF

Application of Direct Inelastic Design for Steel Structures (철골조를 위한 직접비탄성설계법의 적용)

  • Eom, Tae Sung;Park, Hong Gun
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.1 s.74
    • /
    • pp.103-113
    • /
    • 2005
  • In the present study, the Direct Inelastic Design (DID) for steel structures developed in the previous study was improved to expand it applicability. The proposed design method can perform inelastic designs that address the design characteristics of steel structures: Group member design, discrete member sizes, variation of moment-carrying capacity according to axial force, connection types, and multiple design criteria and load conditions. The design procedure for the proposed method was established, and a computer program incorporating the design procedure was developed. The design results from the conventional elastic method and the DID were compared and verified by the existing computer program for nonlinear analysis. Compared with the conventional elastic design, the DID addressing the inelastic behavior reduced the total weight of steel members and enhanced the deformability of the structure. The proposed design method is convenient because it can directly perform inelastic design by using linear analysis for secant stiffness. Also, it can achieve structural safety and economical design by controlling deformations of the plastic hinges.

Design of Anchorage Zone in Prestressed Concrete Structure Using Nonlinear Strut-and-Tie Model (비선형 스트럿-타이 모델을 이용한 PSC 구조물의 정착부 설계)

  • 배한욱;송하원;변근주;변윤주
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.5
    • /
    • pp.101-107
    • /
    • 1998
  • 본 논문은 비선형 스트럿-타이 모델에 의한 프리스트레스트 콘크리트 정착부의 거동해석 및 설계에 관한 연구이다. 프리스트레스트 콘크리트 구조물의 정착부는 긴장재의 인장력 도입으로 인해 비교적 작은 단면에 큰 집중하중으로 발생하는 매우 중요한 구조부위이며, 기존의설계가 비교적 다른 구조부위의설계에 비하여 경험적으로 이루어지고 있을 뿐 만 아니라 해석에도 많은 시간과 계산량이 소요되는 단점이 있다. 비선형 스트럿-타이 모델을 대상 정착부의 비선형 재료거동을 따르도록 비선형 해석을 실시하여 설계를 수행하고 구조물의 극한하중을 추정하는 방법이다. 본 논문에서는 긴장력이 정착부의 중앙에 도입되는 경우, 편심으로 도입되는 경우, 다중 정착구가 존재하는 경우에 대하여 선형과 비선형 스트럿-타이 모델을 구성하여 정착부의 역학적 거동을 고찰하였고 실험결과와 비교하였다. 비교로부터 비선형 모델을 사용한 경우 선형 모델을 사용한 경우보다 안정성을 유지하면서 경제적인 설계가 가능하고 추정극학강도도 실험결과에 더욱 근접함을 알았다.

A Study on the Static Eccentricities of Buildings Designed by Different Design Eccentricities (설계편심의 크기에 따른 비틀림 비정형 건물의 최종 정적편심 크기의 비교에 관한 연구)

  • Lee, Kwang-Ho;Jeong, Seoung-Hoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.5
    • /
    • pp.33-40
    • /
    • 2012
  • To reduce the vulnerability of torsional irregular buildings caused by seismic loads, the torsional amplification factor was introduced by the seismic code. This factor has been applied differently in a variety of seismic codes. In this study, the final static eccentricity, and the lateral and torsional stiffness ratios of buildings designed with different design eccentricities were compared. The increment of the torsional amplification factor resulted in a decrement of the final static eccentricity of the building. However, after reaching the maximum value of this factor, the final static eccentricity of the building increased again. The final static eccentricity of the building designed by multiplying the sum of the inherent and accidental eccentricity by the torsional amplification factor was zero or had a minus value, depending to the position of the vertical element.