• 제목/요약/키워드: 비구조

검색결과 144건 처리시간 0.033초

비구조요소의 내진 설계를 위한 기존 층응답스펙트럼의 평가 (A Study on Evaluation of Floor Response Spectrum for Seismic Design of Non-Structural Components)

  • 최경석;이원호;양원직;김형준
    • 한국지진공학회논문집
    • /
    • 제17권6호
    • /
    • pp.279-291
    • /
    • 2013
  • The seismic damage of non-structural components, such as communication facilities, causes direct economic losses as well as indirect losses which result from social chaos occurring with downtime of communication and financial management network systems. The current Korean seismic code, KBC2009, prescribes the design criteria and requirements of non-structural components based on their elastic response. However, it is difficult for KBC to reflect the dynamic characteristics of structures where non-structural components exist. In this study, both linear and nonlinear time history analyses of structures with various analysis parameters were carried out and floor acceleration spectra obtained from analyses were compared with both ground acceleration spectra used for input records of the analyses and the design floor acceleration spectrum proposed by National Radio Research Agency. Also, this study investigates to find out the influence of structural dynamic characteristics on the floor acceleration spectra. The analysis results show that the acceleration amplification is observed due to the resonance phenomenon and such amplification increases with the increase of building heights and with the decrease of structure's energy dissipation capacities.

물 밑에 잠긴 구 주위의 층류 유동장 해석 (Analysis of Laminar Flows around Submerged Spheres)

  • 곽승현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권8호
    • /
    • pp.1094-1099
    • /
    • 2010
  • 수중에 있는 구 주위의 3차원 층류유동을 수치 해석하였다. 유한체적법을 기반으로 나비에 스톡스 방정식을 비구조격자로 풀어 물체주위의 동역학 현상을 규명하였다. 보티시티, 속도, 동압, 레지듀얼, 항력계수 등의 데이터를 가지고 분석하였다. 레이놀드 수는 425, 300, 250, 100 이다. 구 사이의 거리가 작은 경우가 구 한 개의 후류 유동보다 안정됨을 보였고 구 사이의 간격이 커짐에 따라 유동현상은 불안정하게 나타났다. 후방의 구는 정체압력의 감소를 보였고 이로 인해 저항이 줄어들게 됨을 알 수 있었다. 항력계수의 비교는 본 수치계산이 타당함을 입증하였다.

국내 학교시설 천장재의 내진성능 분석 (Analysis on the Seismic Performance of Ceiling System in School Buildings)

  • 박성철;조진일;정태환
    • 교육녹색환경연구
    • /
    • 제15권1호
    • /
    • pp.11-18
    • /
    • 2016
  • 본 연구는 학교현장의 안전교육 과정에서 학교시설 비구조재 중 위험도가 상대적으로 높은 천장재의 내진성능을 평가하고 대책방안을 제시하는 것이다. 평가도구의 개발을 위하여 본 연구는 다음과 같은 4단계로 진행되었다. 첫 단계에서는 국내 외의 내진성능평가 가이드라인들을 분석하여 주요 천장재의 구성품목과 각 품목별 평가방법들을 조사하고, 두 번째 단계에서는 문헌조사의 결과를 기반으로 주요 품목들의 내진성능 실태를 면밀하게 조사하였다. 세 번째 단계에서는 조사된 천장재 구조를 정량적으로 평가하여 지반 및 지진의 유형에 따른 적정성을 평가하였다. 마지막으로 국내 학교시설 천장재에서 우선적으로 고려되어야 할 내진성능보강 대책방안을 제시하였다.

월류형 잠제 주위의 수면 변동 특성 (Characteristics of Water Surface Variation around Double-Breaking Type Artificial Reef)

  • 신영섭;이성대
    • 한국해양공학회지
    • /
    • 제33권3호
    • /
    • pp.280-288
    • /
    • 2019
  • A submerged breakwater is one of the coastal structures used to reduce wave energy and coastal erosion. However, a submerged breakwater has a negative aspect in that a strong rip current occurring around an open inlet due to a difference in mean water levels at the front and rear sides of the structure leads to scouring. Such scouring has a bad effect on its stability. In order to eliminate this kind of demerit, this study investigated an artificial reef of the overflow type with openings. We also developed a program where the flows around the artificial reef of the overflow type could be analyzed numerically. An unstructured grid system was used to cover the various geometries, and the level set method was applied to treat the movement of the free surface. To verify these numerical schemes, hydraulic physical tests were performed on the submerged breakwater and double breaking type artificial reef. Then, the wave height and velocity distribution around the reef were examined using the experimental results. Comparisons between the results of hydraulic and numerical tests showed reasonable agreement.

비내진 상세를 갖는 금속마감패널 천장시스템의 진동대 실험을 통한 내진성능평가 (Seismic Performance Evaluation of Non-seismic T-bar type Steel-Panel Suspended Ceiling using Shaking Table Test)

  • 이재섭;인성우;정담이;이두용;이상현;조봉호
    • 대한건축학회논문집:구조계
    • /
    • 제35권10호
    • /
    • pp.171-180
    • /
    • 2019
  • In Korea, the seismic design of non-structural elements was interested by Earthquake of the 2016 Gyeong-ju and 2017 Po-hang. Among the non-structural elements, the ceiling system with steel panel used in Po-hang station showed failure examples of non-seismic design ceiling. In this study, the seismic performance of suspended ceiling with steel-panel, such as those used in Po-hang Station, was evaluated by shaking table tests. The shaking table tests were performed in accordance with the ICC-ES AC156 standard with floor acceleration being applied horizontally in one direction using a $3.3{\times}3.3m^2$ frame. The ceiling system consists of steel-panels, carrying channels, main and cross T-bars, and anti-falling clips. The anti-falling clip prevents the steel panel falling completely. The shaking table test confirmed that the damage at the previous stage had a direct impact on the damage state at the next stage. Through the shaking table test, the damage state of the T-bar type steel-panel suspended ceiling system was defined.

무정전전원장치(UPS)의 진동대 실험 및 동적특성 분석 (Investigation of Dynamic Characteristcs Uninterruptible Power Supply System (UPS) Using Shaking Table Tests)

  • 이승재;김주영;최경규
    • 대한건축학회논문집:구조계
    • /
    • 제35권11호
    • /
    • pp.129-136
    • /
    • 2019
  • Non-structural elements are vulnerable to earthquake ground motion. In this study, an experimental study for the electrical non-structural element was performed using tri-axial shaking table tests. A 100kVA UPS(Uninterruptible Power Supply system) was used as the test specimen. The test specimen was anchored to the concrete slab using the conventional installation detail. The input acceleration were generated in accordance with ICC-ES AC156 code. Scale factors of the input acceleration with respect to the required response spectrum defined in ICC-ES AC156 were from 25% to 600%. Based on the test results, damage and dynamic characteristics of UPS were evaluated and analyzed including natural frequency, damping ratio, acceleration time history response, dynamic amplification factor and relative displacement.

음압격리병동의 건축 비구조요소 내진설계를 위한 전산도구 개발 (Development of Computational Tools for Seismic Design of Architectural Components in Negative Pressure Isolation Wards)

  • 추유림;김태진
    • 한국지진공학회논문집
    • /
    • 제26권3호
    • /
    • pp.127-136
    • /
    • 2022
  • Recently, an unprecedented emerging infectious disease has rapidly spread, causing a global shortage of wards. Although various temporary beds have appeared, the supply of wards specializing in infectious diseases is required. Negative pressure isolation wards should maintain their function even after an earthquake. However, the current seismic design standards do not guarantee the negative pressure isolation wards' operational (OP) performance level. For this reason, some are not included in the design target even though they are non-structural elements that require seismic design. Also, the details of non-structural elements are usually determined during the construction phase. It is often necessary to complete the stability review and reinforcement design for non-structural elements within a short period. Against this background, enhanced performance objectives were set to guarantee the OP non-structural performance level, and a computerized tool was developed to quickly perform the seismic design of non-structural elements in the negative pressure isolation wards. This study created a spreadsheet-based computer tool that reflects the components, installation spacing, and design procedures of non-structural elements. Seismic performance review and design of the example non-structural elements were conducted using the computerized tool. The strength of some components was not sufficient, and it was reinforced. As a result, the time and effort required for strength evaluation, displacement evaluation, and reinforcement design were reduced through computerized tools.

금강 상류구간에 대한 홍수예경보시스템 구축 (Establishment of a Flood Forecasting and Warning System for the Upper Section of the Geumgang River)

  • 김상호;김정한;김원
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2023년도 학술발표회
    • /
    • pp.373-373
    • /
    • 2023
  • 기후변화로 인한 홍수재해는 우리나라를 포함한 모든 전세계의 이슈로 우리 앞에 다가와 있다. 수자원 인프라가 잘 구축된 우리나라와 달리 저개발국가로써 관련 인프라가 미흡한 국가의 경우대규모 예산 투입이 필요한 댐, 제방 등의 수자원 인프라 시설보다는 비구조적대책인 홍수예경보시스템 구축을 통해 재해취약지역내 우선적으로 도입하는 유역단위 비구조적인 홍수관리계획이 필요하다(김광기, 2022). 본 연구에서는 2012년 금강권역을 대상으로 구축된 홍수예측모형에 대한 개선을 위해 최신 하도자료와 시설물 현황 자료를 반영하여 수리학적 모형을 신규 구축하였다. 이를 위한 수리학적 홍수추적 모형은 FLDWAV 모형을 사용하였으며, 모형의 대상구간은 금강 상류에 위치한 용담댐에서부터 대청댐 구간까지 189.32 km 구간을 선정하였다. 대상구간은 총 773개의 하도단면으로 구성하여 대상하천에 대한 지형변화를 최대한 반영하고자 하였으며, 홍수사상은 유량이 많은 홍수사상뿐만 아니라 저유량에서도 모형의 정확도를 확보하기 위해 다양한 사상을 선정하여 보정과 검증을 실시하였다. 본 연구에서 구축된 금강의 용담댐에서 대청댐 구간에 대한 수리학적 해석모형은 다양한 홍수사상을 대상으로 모형에 대한 보정과 검증을 실시함으로써 보다 정확도 높은 홍수예경보시스템을 구축하여 하천 재해 발생을 예방하는데 활용할 수 있을 것으로 기대한다.

  • PDF

장주기 지진동을 고려한 건축물 및 비구조요소의 가속도 응답 증폭비 (A Study on the Acceleration Response Amplification Ratio of Buildings and Non-structural Components Considering Long-Period Ground Motions)

  • 오상훈;김주찬
    • 한국지진공학회논문집
    • /
    • 제27권1호
    • /
    • pp.1-12
    • /
    • 2023
  • Structures of high-rise buildings are less prone to earthquake damage. This is because the response acceleration of high-rise buildings appears to be small by generally occurring short-period ground motions. However, due to the increased construction volume of high-rise buildings and concerns about large earthquakes, long-period ground motions have begun to be recognized as a risk factor for high-rise buildings. Ground motion observed on each floor of the building is affected by the eigenmode of the building because the ground motion input to the building is amplified in the frequency range corresponding to the building's natural frequency. In addition, long-period components of ground motion are more easily transmitted to the floor or attached components of the building than short-period components. As such, high-rise buildings and non-structural components pose concerns about long-period ground motion. However, the criteria (ASCE 7-22) underestimate the acceleration response of buildings and non-structural components caused by long-period ground motion. Therefore, the characteristics of buildings' acceleration response amplification ratio and non-structural components were reviewed in this study through shake table tests considering long-period ground motions.

임간초지 개발에 관한 연구 III. 임간혼파초지에서 3요소 시비수준이 목초의 품질과 무기성분함량 및 나무생장에 미치는 영향 (Studies on the Grassland Development in the Foerst III. Effect of fertilizer level on quality , mineral constituents and tree growth of grass-clover mixtures grown under pine trees)

  • 서성;한영춘;박문수;이종열
    • 한국초지조사료학회지
    • /
    • 제5권3호
    • /
    • pp.187-194
    • /
    • 1985
  • 본(本) 시험(試驗)은 임간혼파초지(林間混播草地)에서 3 요소(要素) 시비수준(施肥水準)이 목초(牧草)의 조단백질(粗蛋白質), 조섬유(粗纖維) 및 무기성분함량(無機成分含量)과 임간지(林間地)에서 자란 나무의 생장(生長)에 미치는 영향을 구명(究明)하고자 차광정도(遮光程度) $40{\sim}50%$인 수영(樹齡) $10{\sim}15$년생(年生)의 소나무지대에서 실시(實施)되었다. 4. 시험(試驗)은 13가지 NPK 시비수준을 달리하여 난괴법 3반복으로 배치되었으며, 1984년도(年度) 수원 근교 임간지에서 수행된 시험(試驗)의 결과(結果)를 요약(要約)하면 다음과 같다. 1. 목초중(牧草中) 조단백질함량(粗蛋白質含量)과 총단백질량(總蛋白質量)은 대체로 질소시비수준이 표준비 이상일 때 높았으며, 3 요소 무비구와 질소무비구에서 가장 낮았고, 인산과 칼리가 단백질함량에 미치는 영향은 작았다. 2. 조섬유함량중(粗纖維含量中) lignin과 silica함량은 3 요소 시비수준이 증가함에 따라 감소하였으나 (P<0.05), NDF, ADF, cellulose 및 hemicellulose함량은 시비수준별(施肥水準別) 유의성 있는 차이가 없었다. 조섬유함량(粗纖維含量)과 소화율(消化率)은 질소시비에 의해 영향을 받았으며, 인산과 칼리시비의 영향은 작았다. 3. 목초(牧草)의 무기성분함량중(無機成分含量中) N, K 및 $SiO_2$ 함량은 시비수준별(施肥水準別) 차이가 있었으나, P, Ca, Mg 및 Na 함량은 시비수준별 차이가 없었다. 4. 각 시비수준별(施肥水準別) NPK 비료회수율(肥料回收率)은 표준비시용에서 가장 높았고, 그 이상의 시비수준(施肥水準)에서는 낮았으며, $K_2O>N>P_2O_5$순(順)이었다. 5. 나무생장(生長)도 3 요소(要素) 시비수준(施肥水準)이 증가함에 따라 증가하는 경향을 보였으며 목초(牧草)에 미치는 영향과 마찬가지로 질소시비의 영향이 크고, 인산과 칼리시비의 영향은 작았다. 6. 이상(以上)의 결과(結果)를 종합(綜合)하여 볼 때 목초중(牧草中) 단백질(蛋白質), 조섬유(粗纖維) 및 무기성분함량(無機成分含量)과 나무생장(生長)에서는 질소시비(施肥)의 영향이 가장 컸으며, 임간초지(林間草地)에서 목초(牧草)의 품질(品質)을 높이고, 양질(良質)의 목초(牧草)를 가축에게 급여하기 위해서는 표준비시용(標準肥施用)($N-P_2O_5-K_2O=28-20-24kg/10a$)이 바람직하다고 생각된다.

  • PDF