• Title/Summary/Keyword: 비공면

Search Result 3, Processing Time 0.017 seconds

Spacecraft Intercept on Non-coplanar Elliptical Orbit Considering J2 Perturbation (J2 섭동을 고려한 비공면 타원 궤도에서의 우주비행체 요격)

  • Oghim, Snyoll;Leeghim, Henzeh
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.11
    • /
    • pp.902-910
    • /
    • 2018
  • This paper deals with spacecraft intercept problem on non-coplanar elliptical obit considering J2 perturbation. This disturbance addressed in this work is a major factor changing the trajectory of a spacecraft orbiting the Earth. To resolve this issue, a real-time intercept method is proposed. This method is based on the optimization problem which consist of the equation of motion considering spherical earth and impulse, and the optimal solution numerically obtained is set as the direction of the thrust of the interceptor. The position error is resolved by iteratively solving the optimization problem and modifying the direction of thrust of interceptor. The proposed method in this paper is verified by using various numerical examples.

Methodologic Aspect of LINAC-based Stereotactic Radiosurgery (선형가속기 기반 뇌정위 방사선 수술기법)

  • Choi, Tae Jin
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.127-137
    • /
    • 2012
  • A conversing beam is firstly designed for radiosurgery by a neurosugern Lars Leksell in 1949 with orthogonal x-rays tube moving through horizontal moving arc to focusing the beam at target center. After 2 decades he composits 201 source of the Co-60 for gamma knife which beams focused at locus. Sveral linac-based stereotactic radiosurgery using the circular collimated beam which size range for 0.4~4.0 cm in a diameter by non-coplanar multiarc have been developed over the decades. The irregular lesions can be treated by superimposing with several spherical shots of radiation over the tumour volume. Linac based techniques include the use of between 4 and 11 non-co-planar arcs and a dynamic rotation technique and use photon beam energies in the range of 6~10 MV. Reviews of the characteristics of several treatment techniques can be found in the literature (Podgorsak 1989, Schell 1991). More in recent, static conformal beams defined by custom shaped collimators or a mini- or micro-multileaf collimator (mMLC) have been used in SRS. Finally, in the last few years, intensity-modulated mMLC SRS has also been introduced. Today, many commercial and in-house SRS programs have also introduced non-invasive immobilization systems include the cyberknife and tomotherapy and proton beam. This document will be compared the characteristics of dose distribution of radiosurgery as introduced gamma knife, BrainLab include photon knife in-house SRS program and cyberknife in currently wide used for a cranial SRS.

Non-Linear Optical Properties of Polyacetylene Using Ab Initio Time-Dependent Hartree-Fock Theory (폴리 아세틸렌의 비선형 광학성질에 대한 양자 역학적 고찰)

  • Kim, Seung Joon
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.5
    • /
    • pp.317-326
    • /
    • 1996
  • The frequency dependent longitudinal polarizabilities ${\alpha}zz(\omega)$ and the second hyper-polarizabilities ${\gamma}zzzz(\omega)$ of the linear polyenes, $C_4H_6\;to\;C_{30}H_{32}$, have been evaluated using the ab initio time-dependent coupled perturbed Hartree-Fock (TDCPHF) theory with the 6-31G basis set. The ratios of the dynamic properties to the static values have been examined to illustrate the relative dispersion effect and extrapolated to the infinite polymer limit. Also the effect of interchain interaction for linear and nonlinear optical properties has been investigated for $C_4H_6$ and the theoretical discussion has been described to overcome the limitation of ab initio TDHF method in the resonance region.

  • PDF