• Title/Summary/Keyword: 불포화화강암풍화토

Search Result 11, Processing Time 0.021 seconds

Analysis of Rainfall Infiltration Velocity for Unsaturated Soils by an Unsaturated Soil Column Test : Comparison of Weathered Gneiss Soil and Weathered Granite Soil (불포화토 칼럼시험을 통한 불포화토 내 강우침투속도 분석: 편마암 풍화토와 화강암 풍화토의 비교)

  • Park, Kyu-Bo;Chae, Byung-Gon;Kim, Kyeong-Su;Park, Hyuek-Jin
    • Economic and Environmental Geology
    • /
    • v.44 no.1
    • /
    • pp.71-82
    • /
    • 2011
  • The unsaturated soil column tests were carried out for weathered gneiss soil and weathered granite soil in order to obtain the relationship between rainfall intensity and infiltration velocity of rainfall on the basis of different unit weight conditions of soil. In this study, volumetric water content and pore water pressure were measured using TDR sensors and tensiometers at constant time interval. For the column test, three different unit weights were used as in-situ condition, loose condition and dense condition, and rainfall intensities were selected as 20 mm/h and 50 mm/h. In 20 mm/h rainfall intensity condition, average rainfall infiltration velocities for both gneiss and weathered granite soils were obtained as $2.854{\times}10^{-3}$ cm/s ~ $1.297{\times}10^{-3}$ cm/s for different unit weight values and $2.734{\times}10^{-3}$ cm/s ~ $1.707{\times}10^{-3}$ cm/s, respectively. In 50 mm/h rainfall intensity condition, rainfall infiltration velocities were obtained as $4.509{\times}10^{-3}$ cm/s ~ $2.016{\times}10^{-3}$ cm/s and $4.265{\times}10^{-3}$ cm/s ~ $3.764{\times}10^{-3}$ cm/s respectively. The test results showed that the higher rainfall intensity and the lower unit weight of soil, the faster average infiltration velocity. In addition, the weathered granite soils had faster rainfall infiltration velocities than those of the weathered gneiss soils except for the looser unit weight conditions. This is due to the fact that the weathered granite soil had more homogeneous particle size, smaller unit weight condition and larger porosity.

Analysis of Rainfall Infiltration Velocity in Unsaturated Soils Under Both Continuous and Repeated Rainfall Conditions by an Unsaturated Soil Column Test (불포화토 칼럼시험을 통한 연속강우와 반복강우의 강우침투속도 분석)

  • Park, Kyu-Bo;Chae, Byung-Gon;Park, Hyuck-Jin
    • The Journal of Engineering Geology
    • /
    • v.21 no.2
    • /
    • pp.133-145
    • /
    • 2011
  • Unsaturated soil column tests were performed for weathered gneiss soil and weathered granite soil to assess the relationship between infiltration velocity and rainfall condition for different rainfall durations and for multiple rainfall events separated by dry periods of various lengths (herein, 'rainfall break duration'). The volumetric water content was measured using TDR (Time Domain Reflectometry) sensors at regular time intervals. For the column tests, rainfall intensity was 20 mm/h and we varied the rainfall duration and rainfall break duration. The unit weight of weathered gneiss soil was designed 1.21 $g/cm^3$, which is lower than the in situ unit weight without overflow in the column. The in situ unit weight for weathered granite soil was designed 1.35 $g/cm^3$. The initial infiltration velocity of precipitation for the two weathered soils under total amount of rainfall as much as 200 mm conditions was $2.090{\times}10^{-3}$ to $2.854{\times}10^{-3}$ cm/s and $1.692{\times}10^{-3}$ to $2.012{\times}10^{-3}$ cm/s, respectively. These rates are higher than the repeated-infiltration velocities of precipitation under total amount of rainfall as much as 100 mm conditions ($1.309{\times}10^{-3}$ to $1.871{\times}10^{-3}$ cm/s and $1.175{\times}10^{-3}$ to $1.581{\times}10^{-3}$ cm/s, respectively), because the amount of precipitation under 200 mm conditions is more than that under 100 mm conditions. The repeated-infiltration velocities of weathered gneiss soil and weathered granite soil were $1.309{\times}10^{-3}$ to $2.854{\times}10^{-3}$ cm/s and $1.175{\times}10^{-3}$ to $2.012{\times}10^{-3}$ cm/s, respectively, being higher than the first-infiltration velocities ($1.307{\times}10^{-2}$ to $1.718{\times}10^{-2}$ cm/s and $1.789{\times}10^{-2}$ to $2.070{\times}10^{-2}$ cm/s, respectively). The results reflect the effect of reduced matric suction due to a reduction in the amount of air in the soil.

Analysis on Failure Critical Depth of Unsaturated Landslide Zone According to the Geological Condition (지질별 불포화토 사면의 붕괴 임계심도 분석)

  • Nam, Koung-Hoon;Kim, Min-Gyu;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.25 no.2
    • /
    • pp.299-304
    • /
    • 2015
  • Slope stability analysis of unsaturated soil slopes due to rainfall infiltration is an important issue in evaluating landslide analysis and stability assessment. The purpose of this study is to establish the critical depth considering weathered soil of parent rock and rainfall intensity at main scarp in national landslide. Based on the analytical results, it is found that as rainfall duration and Slope angle increased, the critical depth of gneiss-weathered soil increased from 3.00 m to 3.77 m, the critical depth of granite weathered-soil increased from 1.75 m to 2.40 m, and the critical depth of mudstone-weathered soil increased from 3.00 m to 4.15 m, respectively. The critical depth of granite-weathered soil with low cohesion and high internal friction angle is much lower than those of other soils. It is interestingly shown that a decrease in the safety factor is highly significant, much affected by the slope increase rather than the rainfall intensity.

Comparative Study on Unsaturated Characteristic Curves of Boeun Granite Weathered Soil during Drying and Wetting Paths (건조 및 습윤과정에서 보은 화강암 풍화토의 불포화특성곡선 비교)

  • Song, Young-Suk
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.7
    • /
    • pp.15-24
    • /
    • 2016
  • To investigate the unsaturated characteristics of the Boeun granite weathered soil, matric suction and volumetric water content were measured in both drying and wetting paths using Automated Soil-Water Characteristics Curve Apparatus. Based on the measured results, Soil-Water Characteristics Curve was estimated by van Genuchten (1980) model. The relationship between effective degree of saturation and matric suction showed the non-linear curve with S-shape and the hysteresis phenomenon occurred during drying and wetting paths. Suction Stress Characteristics Curve was estimated by the Lu and Likos (2006) model. The suction stress in drying path was constantly maintained and that in wetting path tended to increase when the effective degree of saturation was low. But the suction stress in drying path was larger than that in wetting path at the same degree of saturation when the effective degree of saturation became larger. Meanwhile, Hydraulic Conductivity Function was evaluated by the van Genuchten (1980) model which is one of the parameter estimation methods. The unsaturated hydraulic conductivity decreased with increasing the matric suction, and the decreasing velocity regarding to the matric suction in drying path was larger than that in wetting path.

Comparison of Infiltration Rate of Slope in Model Test and Finite Element Analysis (모형시험과 유한요소해석에서 비탈면 강우의 침투량 비교)

  • Yu, Yong-Jae;Kim, Jae-Hong
    • Land and Housing Review
    • /
    • v.9 no.2
    • /
    • pp.51-57
    • /
    • 2018
  • The causes of landslides are dependant on rainfall events and the soil characteristics of a slope. For the conventional slope stability, the slope stability analysis has been carried out assuming the saturated soil theory. But, in order to clearly explain a proper soil slope condition by rainfall, the research should be performed using the unsaturated soil mechanism suitable for a soil slope in the field. In the study, by using two major categories of soils in Korea, such as granite and gneiss weathered soils, landslide model test and finite element method have been compared with the difference of seepage and soil stability analysis. The hydraulic conductivity of gneiss weathered soil is slower than that of granite weathered soil, and the gneiss weathered soil contains much finer soils than the granite weathered soil. It was confirmed that the instability of the slope was progressing slowly due to the slow rate of volumetric water content of the surface layer.

Dynamic Behavior of Unsaturated Decomposed Granite Soils under Low Shear Strain Amplitude (저전단변형율에서의 불포화화강풍화토의 동적 거동)

  • Huh, Kyung-Han;Baek, Joong-Yuk
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.2 s.17
    • /
    • pp.57-63
    • /
    • 2005
  • In case of general structures, it has been known that the strain amplitude band experienced by the base in a state of service load is less than 1% and most of the base show low, strain amplitude behavior less than 0.01%. In this study examining the influence affected to dynamic behavior in a condition of the low strain amplitude of unsaturated decomposed granite soils, the resonant column test, using some samples in Su-won area, has been performed for each degree of saturation resulted from different void ratios and confined stress. It is found out that the minimum value of the damping ratio occurred in roughly $17{\sim}18%$ according to void ratios regardless of confined pressure in the same manner with the case of the maximum shear elastic modulus; and it is estimated that for the influence of surface tension in the optimum degree of saturation, the damping ratio appears to be least.

The Physical and Shear Strength Properties of the Weathered Limestone Soils in Changsung and Hwasun Area of Chonnam Province, Korea (전라남도 장성과 화순에 분포하는 석회암풍화토의 물성 및 전단 특성)

  • 김해경
    • The Journal of Engineering Geology
    • /
    • v.13 no.3
    • /
    • pp.335-344
    • /
    • 2003
  • This study is focused to the physical and shear strength properties of the weathered limestone soils distributed in Changsung and Hwasun area, Chonnam province. Disturbed soil was used as soil samples. To grasp the physical and shear strength properties of weathered limestone soil, specific gravity test, atterberg limit, grain size distribution and direct shear test were conducted in the laboratory. The physical and shear strength properties of the weathered limestone soil in the study areas are as follows. The range of specific gravity (Gs) is 2.78 to 2.80, liquid limits (LL) 37 to 38 (%), plasticity index (PI) 13.7 to 15.4, and soil classification CL. The range of strength parameters by direct shear test (vd, $1.5t/\textrm{m}^3$) is 3.07 to 4.4 ($t/\textrm{m}^2$) of cohesion and 34.8 to $42.4^{\circ}$ of internal friction angle in unsaturated soils. As a result of comparing with the weathered granite soils (Yang, 1997: Mun, 1998: Park, 1998), it is considered that physical properties of the weathered limestone soils in this study are different from the weathered granite soils. On the other hand, internal friction angle of shear parameters is found to be similar.

Study on Landslide Flume Tests Using Stability Analysis of the Unsaturated Infinite Slope (불포화 무한사면의 안정해석을 활용한 산사태 모형실험에 관한 연구)

  • Song, Hyo-Sung;Chae, Byung-Gon;Song, Young-Suk;Choi, Jung-Hae;Seo, Won-Gyo;Woo, Ik
    • The Journal of Engineering Geology
    • /
    • v.29 no.4
    • /
    • pp.541-552
    • /
    • 2019
  • In this study, landslide flume tests were performed to analyze characteristics of ground characteristics and landslide occurrence due to rainfall infiltration. As test materials, weathered granite soil and gneiss soil, the most frequent landslides in Korea, were used, and landslides were triggered by heavy rain (Intensity = 200 mm/hr). The measurement sensors were installed with 3 sets at toe, slope, top part and shallow (GL-0.2 m), middle (GL-0.4 m), and deep (GL-0.6 m) depth in the slope and measured at 10 second intervals. After landslide flume tests, the slope stability analysis was performed by applying the unsaturated soil theory based on the change of ground characteristics and compared with actual landslide occurrence from flume test. As a result of the analysis, factor of safety reflected the landslide occurrence from flume test and factor of safety decreased as rainfall infiltration, leading to slope failure. Finally we compared to the factor of safety below 1 and actual landslide occurrence time, the average difference was 1,600 seconds for weathered granite soil and 5,400 seconds for weathered gneiss soil.

Comparison of Rainfall Seepage Characteristics of Gneiss and Granite Weathered Soil (편마암풍화토와 화강암풍화토의 강우 침투특성 비교)

  • Song, Young-Suk;Yoo, Yong-Jae;Kim, Tae-Wan;Kim, Jae-Hong
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.6
    • /
    • pp.21-28
    • /
    • 2021
  • The factors of landslides depend on rainfall intensity, duration, and the characteristics of the soil slope. The conventional slope stability analysis has been carried out by assuming that the slope is saturated. But, a site slope consisting of unsaturated ground must be imitated and interpreted in order to explain a proper behavior of the slope due to rainfall. In this study, by using two major categories of soils in Korea, such as granite and gneiss weathered soils, landslide model test and numerical analysis have been compared with the difference of seepage and volumetric water content. In general, the permeability of gneiss weathered soil, which contains a lot of fines content, is slower than that of granite weathered soil. As a result, in extreme rainfall, numerical analysis can show results that can penetrate quickly, resulting in saturation or more dangerous collapse.

Application of Weathered Granite Soils as Backfill Material of Reinforced Earth Structure (보강토구조물 뒤채움 재료로서 화장풍화토의 적용성)

  • 김상규;이은수
    • Geotechnical Engineering
    • /
    • v.12 no.1
    • /
    • pp.63-72
    • /
    • 1996
  • The current practice in construction of reinforced earth retaining walls is to use a granular soil for the backfill material. When the material is available in site, the construetion cost can be remarkably reduced. As the weathered granite soils are abundant and widely distributed throughout the Korean peninsula: whether they are suitable or not as the backfill material is considered to be the most important key in economic construction of the wall. This paper investigates the grain size distribution of the weathered soils which locate at many places throughout the nation and then examines limitation of their use based on the specifications of different countries. The variaton of shear strength with both different fine contents and saturation is also investigated. It is known that the grain size distribution of most weathered soils are not satisfied with the general requirement. However their use is possible in wide range when the backfill keeps in unsaturated condition using good drainage facilities and 1 or pervious reinforcements.

  • PDF