The Fusion Effect of Deep Transverse Stroking, Manual Stretching Exercise and Active Muscle Release Technique on Psoas Major Muslce Thickness and Muscle Tone and Pelvic Angle of Non-specific Low Back Pain Patient (비특이성 허리통증환자 큰허리근의 근두께와 근긴장도, 골반각도에 심부횡적강찰법과 수동신장운동, 능동적근육이완기법이 융합적으로 미치는 영향)

  • Lee, Ho-Jae;Shim, Jae-Hun;Kim, Ji-Won;Kim, Ki-Song
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.3
    • /
    • pp.137-144
    • /
    • 2018
  • The purpose of this study was to investigate the fusion effects and difference them of the deep transverse stroking, manual stretching exercise and active muscle release technique on psoas major muscle thickness and muscle tone, and pelvic angle in non-specific low back pain patients. Psoas major muscle thickness was significantly decreased after the application of the deep transverse stroking $0.19{\pm}0.16cm$ (p <0.05), manual stretching exercise $0.18{\pm}0.14cm$ (p <0.05), and active muscle release technique $0.43{\pm}0.35cm$ (p <0.05). The pelvic angle was significantly decreased after the application of the deep transverse stroking $4.48{\pm}1.63^{\circ}$ (p <0.05), manual stretching exercise $5.36{\pm}2.04^{\circ}$ (p <0.05), and active muscle release technique $7.24{\pm}2.23^{\circ}$ (p <0.05). The Psoas major muscle tone was significantly decreased after application of the deep transverse stroking $0.96{\pm}0.93Hz$ (p <0.05), but manual stretching exercise $0.87{\pm}1.20Hz$ (p> 0.05) and active muscle release technique $0.82{\pm}0.98Hz$ (p> 0.05) there was no significant difference after application. There were no significant differences between the three intervention methods in the pelvic angle and psoas major muscle thickness and tone changes. In order to change psoas major muscle thickness and pelvic angle, three intervention methods should be applied appropriately according to the condition and environment of the patient, and deep transverse stroking is more effective for changing psoas major muscle tone.

Comparison of Activity Capacity Change and GFR Value Change According to Matrix Size during 99mTc-DTPA Renal Dynamic Scan (99mTc-DTPA 신장 동적 검사(Renal Dynamic Scan) 시 동위원소 용량 변화와 Matrix Size 변경에 따른 사구체 여과율(Glomerular Filtration Rate, GFR) 수치 변화 비교)

  • Kim, Hyeon;Do, Yong-Ho;Kim, Jae-Il;Choi, Hyeon-Jun;Woo, Jae-Ryong;Bak, Chan-Rok;Ha, Tae-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.27-32
    • /
    • 2020
  • Purpose Glomerular Filtration Rate(GFR) is an important indicator for evaluating renal function and monitoring the progress of renal disease. Currently, the method of measuring GFR in clinical trials by using serum creatinine value and 99mTc-DTPA(diethylenetriamine pentaacetic acid) renal dynamic scan is still useful. After the Gates method of formula was announced, when 99mTc-DTPA Renal dynamic scan is taken, it is applied the GFR is measured using a gamma camera. The purpose of this paper is to measure the GFR by applying the Gates method of formula. It is according to effect activity and matrix size that is related in the GFR. Materials and Methods Data from 5 adult patients (patient age = 62 ± 5, 3 males, 2 females) who had been examined 99mTc-DTPA Renal dynamic scan were analyzed. A dynamic image was obtained for 21 minutes after instantaneous injection of 99mTc-DTPA 15 mCi into the patient's vein. To evaluate the glomerular filtration rate according to changes in activity and matrix size, total counts were measured after setting regions of interest in both kidneys and tissues in 2-3 minutes. The distance from detector to the table was maintained at 30cm, and the capacity of the pre-syringe (PR) was set to 15, 20, 25, 30 mCi, and each the capacity of post-syringe (PO) was 1, 5, 10, 15 mCi is set to evaluate the activity change. And then, each matrix size was changed to 32 × 32, 64 × 64, 128 × 128, 256 × 256, 512 × 512, and 1024 × 1024 to compare and to evaluate the values. Results As the activity increased in matrix size, the difference in GFR gradually decreased from 52.95% at the maximum to 16.67% at the minimum. The GFR value according to the change of matrix size was similar to 2.4%, 0.2%, 0.2% of difference when changing from 128 to 256, 256 to 512, and 512 to 1024, but 54.3% of difference when changing from 32 to 64 and 39.43% of difference when changing from 64 to 128. Finally, based on the presently used protocol, 256 × 256, PR 15 mCi and PO 1 mCi, the GFR value was the largest difference with 82% in PR 15 mCi and PO 1 mCi. conditions, and at the least difference is 0.2% in the conditions of PR 30 mCi and PO 15 mCi. Conclusion Through this paper, it was confirmed that when measuring the GFR using the gate method in the 99mTc-DTPA renal dynamic scan. The GFR was affected by activity and matrix size changes. Therefore, it is considered that when taking the 99mTc-DTPA renal dynamic scan, is should be careful by applying appropriate parameters when calculating GFR in the every hospital.