• Title/Summary/Keyword: 분사지속시간

Search Result 18, Processing Time 0.031 seconds

Experimental Study on Fuel/Air Mixing using Inclined Injection in Supersonic Flow (경사 분사에 의한 초음속 유동 연료-공기 혼합에 관한 실험적 연구)

  • Lee, Dong-Ju;Jeong, Eun-Ju;Kim, Chae-Hyoung;Jeung, In-Seuck
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.281-284
    • /
    • 2008
  • The flow of combustor in scramjet engine is supersonic speed. So residence time and mixing ratio are very important factors for efficient combustion. This study used open cavity on fuel/air mixing model and laser schlieren was carried out to investigate flow characteristics around a jet orifice and a cavity. A source of illumination has 10 ns endurance time so it can observe unsteady flow characteristics efficiently. Pressure was measured by varying momentum flux ratio. And the change of critical ignition point was observed to change of momentum flux ratio.

  • PDF

Experimental Study on Fuel/Air Mixing using Inclined Injection in Supersonic Flow (경사 분사에 의한 초음속 유동 연료-공기 혼합에 관한 실험적 연구)

  • Lee, Dong-Ju;Jeong, Eun-Ju;Kim, Chae-Hyoung;Jeung, In-Seuck
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.4
    • /
    • pp.9-15
    • /
    • 2009
  • The flow of combustor in scramjet engine has supersonic speed so that the residence time and mixing ratio are very important factors for the efficient combustion. This study used open cavity(L/D=4.8) as a fuel/air mixing model. Laser schlieren visualization and pressure measurement were carried out to observe the flow characteristics around a jet orifice and a cavity at the time of fuel injection. As a result of 10ns laser schlieren, unsteady flow which was around the cavity could be observed effectively. Pressure was measured that momentum flux ratio(J) was changed. And the change of critical ignition point could be observed by the momentum flux ratio changed.

Study on Water Cycle Performance Evaluation Experiment of Permeable Block (투수블럭의 물순환 성능평가 실험에 관한 연구)

  • Jang, Young Su;Park, Jong Bin;Lee, Jae Hyuk;Kim, Jae Moon;Jung, Min Ho;Shin, Hyun Suk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.331-331
    • /
    • 2020
  • 급격한 산업화와 도시화로 인한 도시유역의 불투수면의 증가와 이에 따른 배수능력의 저하로 인해 도시 물순환의 왜곡이 발생하였다. 따라서 과거 도시 물관리 기법의 한계가 나타났으며 이를 위해 저영향개발 기법 등과 같은 도시 물관리 기법의 패러다임이 변화하였다. 본 연구에서는 저영향개발 기법에서 도시유역 내 활용이 유용한 침투형 시설 중 투수블럭에 대한 물순환 성능평가를 실외실험을 통해 분석하였다. 성능평가 실험은 부산대학교 양산캠퍼스 한국 GI&LID 센터 내 투수블록 뿐만 아니라 블록 하부 골재층까지 설치가 가능하도록 되어있어 실제 현장과 유사한 환경을 구축이 가능한 2.4×10.9×0.4 (m) 규모의 주차장형 LID 실증시험시설을 활용하였다. 인공강우 분사를 위한 실외 인공강우모사 장치 크기는 2×2(m)으로 본 시험을 위하여 5개의 인공강우모사 장치를 연결하여 활용하였으며, 본 시험장치는 강우를 공급하기 위한 수조와 펌프, 일정한 유량을 유입하기 위한 유량계, 강우를 분사하기 위한 노즐, 인공강우가 실제 강우와 같이 자유낙하 하도록 구현하기 위한 오실레이터 등으로 구성되었다. 시험대상인 틈새투수블록은 석재블록 규격 400×600×100 mm이며 재질은 받침안정층(흙), 투수블록(화강석)으로 구성되어 있다. 실험의 시나리오는 시험체에 강우강도 30mm/hr, 50mm/hr, 100mm/hr에 해당하는 양을 1시간 동안 유입하여 시험 시작 후, 강우지속시간, 표면유출지속시간, 표면유출량을 1분 단위로 측정. 시험체에 유공관이 설치된 경우에는 침투유출지속시간, 침투유출량도 함께 1분 단위로 측정하였으며 각 강우강도별로 측정하고, 1회 측정 후, 각 시험별 시험 대상체의 조건을 같게 하기 위한(하부 지반의 건조) 약 3일 이후(상황에 따라 변동 가능) 시험하였다. 본 실험의 결과, 강우강도가 30 mm/hr와 50 mm/hr인 경우에는 화강석 틈새투수블록포장에서 지표 유출이 발생하지 않았으며, 강우강도 100 mm/hr의 경우 260 L의 지표 유출이 발생하여, 불투수표면 대비 84%의 지표유출 저감률을 보여줌으로서 투수블럭에 물순환 성능에 대한 효과를 분석하였다.

  • PDF

Design of Supersonic Wind Tunnel for Analysis of Flow over a Backward Facing Step with Slot Injection (슬롯 분사가 있는 후향계단 유동장 분석을 위한 초음속풍동 설계)

  • Kim, Ick-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.363-367
    • /
    • 2016
  • A test section of a supersonic wind tunnel was designed for the analysis of flow characteristics over a backward-facing step with Mach 1.0 slot injection in a supersonic flow of Mach 2.5. The cavity flow of a high-speed vehicle is very complex at supersonic speed, so it is necessary to do experiments using supersonic wind tunnels to verify numerical analysis methods. The previous 2D symmetrical nozzle was replaced with an asymmetrical nozzle. The inviscid nozzle contour was designed using Method of Characteristics (MOC), and the boundary layer thickness correction was reflected by experimental data from the wind tunnel. The results were compared with a CFD analysis. The PID control system was changed to be based on the change of tank pressure. This improved the control efficiency, and the run times of supersonic flow increased by about 1 second. The flow characteristics over a backward facing step with slot injection were visualized by a Schlieren device. This equipment will be used for an experimental study of the film cooling effectiveness over a cavity with various velocities, mass flows, and temperatures.

A Study on the Cleaning Device of Bidet Washer (비데 세정기의 세척장치에 관한 연구)

  • Lim, Yeon-Jeong;Lim, Sang-Ho
    • Industry Promotion Research
    • /
    • v.4 no.1
    • /
    • pp.21-27
    • /
    • 2019
  • This study is about the bidet which is used to clean the anal and local parts after the user seated on the left side of the toilet in the toilet. The cleaner of the bidet which is contaminated from various bacteria and dirt is washed clean with clean water to keep it clean The present invention relates to a cleaning device for a bidet cleaner that hygienically maintains a bidet used by a plurality of users. As a result of developing and studying a bidet nozzle that can be implemented with a bidet nozzle and a washing nozzle for automatically washing the jetting head of the bidet and the jetting head, the optimum jetting time of the nozzle after the hydraulic jetting is 1 second To 10 seconds, it was confirmed that the nozzle cleanliness of an average of 5 seconds was maintained at 100%. Subsequent studies will require further study of the durability of the product and the cleaning safety at a pressure of $5kg/mm^2$. Toilet bidet is a product that is closely related to the safety and life of the people, but the development of various technologies is still insufficient. Therefore, it is meaningful that this study contributed to the quality of life of the people by continuously researching and developing the bidet.

Flame Retardant and Weather Proof Characteristic of Dan-Chung Treated Wooden by Flame Retardant Performance (방염처리 방법에 따른 단청목재의 방염 및 내후특성)

  • Park, Cheul-Woo;Hong, Sang-Wan;Lee, Jong-Kyun;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.2
    • /
    • pp.122-130
    • /
    • 2013
  • One of recent methods to protect wooden cultural assets from fire, there is the flame retardation which is applied directly to wood and it is to prevent fire through securing flame resistance for the material and delaying combustion when failed fire in advance and then to gain time for people in the room to evacuate and it has same goal with the Korean Fire Service Act by protecting life and property. However, in case of spraying flame retardant on the colored surface of the wooden cultural assets, there are continuous problems of decoloration, efflorescence and water absorbtion after sometime and accordingly there increases danger of damages of cultural assets. So when treating with flame retardant on wooden cultural assets, there has to be no problems on dancheong after sometime and securing sustainable methods for flmae retardation should be preceded. Accordingly, this study aims to provide basic sources for selecting proper flame retardation methods by evaluating and analyzing flame retardation capabilities according to types of flame retardants which are frequently used nowadays and spraying them on the dancheong-painted surface and confirming if there is no problem on the dancheong and wood after sometime and if flame retardation effect is sustainable with its quality and capability through precise analysis.

Fouling Control Technique of Membrane Using Simultaneously Washing Process (동시세정방식을 이용한 막의 fouling 억제기술)

  • Choi, I-Song;Son, Chang-Sun;Kim, Sung-Yoon;Lim, Byung-Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1637-1641
    • /
    • 2009
  • 본 연구는 막공정을 이용하는 수처리기술에 있어서 최대 난점 중의 하나인 fouling 현상을 억제하기 위하여 여과방향의 반대방향에서 여과수를 지속적으로 분사하여 줌으로써 여과와 세정이 동시에 일어나는 동시세정방식을 평가하기 위한 것이다. 실험은 성균관대학교 환경플랜트 내에 pilot 실험지를 조성하여 실시하였으며, 실험원수는 오수처리방류수를 저류하는 연못수와 오수원수를 혼합하여 농도를 조절한 후에 저농도와 고농도 조건에서 실험을 실시하였다. 저농도 조건(SS 10$\sim$20 mg/L)에서는 연못의 HRT를 고려하여 일일 5시간 씩 8일간 가동하였고, 고농도 조건(SS 200 mg/L 이상)에서는 8시간씩 가동하였다. 저농도의 경우에는 가동기간 중 배수가 일어나지 않았고, 일일 운전 종료 후 유지관리를 위한 강제배수만 실시하였다. 고농도에서는 초기에 배수가 짧은 term으로 자주 일어났지만, 20분 이상의 비교적 긴 여과지속시간을 유지하였고 유입수 농도가 낮아지면서 배수타임이 점점 늘어나는 경향을 보였다. 이러한 결과는 동시세정방식에 의한 여과기술에 있어 유입수 농도가 fouling 발생빈도에 크게 영향을 미친다는 것을 의미하며, $5\;{\mu}m$의 미세막에서도 고농도 운전이 가능하다는 사실을 보여준다. 동시세정방식은 Rum Filter의 fouling을 억제하고 지속적인 운전을 가능하게 해주는 핵심기술이다. 세정 시 세정압력설정은 매우 중요한 운전인자 중 하나인데, 세정압력이 너무 클 경우에는 소요되는 동력이 많아져 효율적인 설계 및 운전에 장애요인이 될 수 있고, 너무 낮을 경우에는 세정이 제대로 되지 않고 여과막 내부와 외부의 압력차를 크게 가져와 배수타임이 빨라지는 결과를 초래한다. 따라서 적절한 세정압력을 파악하고 설정하기 위하여 세정압력을 변화시켜가면서 이에 따른 차압의 변화를 관측하여 보았다. 여과막의 공극과 세정압력에 변화를 주면서 실험을 한 결과, 세정압력이 커지면 여과막에 작용하는 부하가 약간 증가하는 것으로 나타났지만, 그 차이가 $0.02\;kg_f/cm^2$으로 나타나, $4.0\;kg_f/cm^2$ 이상의 세정압력에서 적용이 가능한 것으로 나타났다. 또한, 유입유량을 설정하기 위하여 $4.5\;kg_f/cm^2$의 세정압력을 유지한 상태로 유입유량을 점진적으로 증가시키면서 압력의 변화를 관측하였다. $5\;{\mu}m$에서는 180 LPM 및 200 LPM에서, $8\;{\mu}m$에서는 200 LPM에서 자체적으로 설정한 배수차압 상승분인 $0.1\;kg_f/cm^2$를 초과한 것으로 나타났고, $10\;{\mu}m$ 이상에서는 모두 200 LPM이상 처리해도 배수압력에 걸리지 않는 것으로 나타났다. 이러한 결과는 현재 본 시스템에 적용하고 있는 유입유량 기준치를 2배 이상 상회하는 결과로서 추가적인 실험을 통하여 기존 여과기술보다 여과지속시간이길고, 여과 flux가 높은 기술을 개발할 수 있을 것으로 판단된다.

  • PDF

A Study on the DME Application Performance of a High Pressure Fuel Pump for an Electric Controlled Common-rail Compression Ignition Engine (전자제어 커먼레일 압축착화엔진용 고압연료펌프의 DME 적용 성능에 관한 연구)

  • Chung, Jae-Woo;Kim, Nam-Ho;Kang, Jung-Ho;Park, Sang-Wook;Lee, Ho-Kil;Choi, Seung-Kyu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.2
    • /
    • pp.132-140
    • /
    • 2009
  • Recently, the interest in the development of high efficiency Diesel engine technology using alternative fuel has been on the rise and related studies are being performed. Therefore, the DME(Dimethyl Ether), an oxygen containing fuel as an alternative fuel for light oil that can be used for diesel engines since it generates very little smoke. But it is unavoidable that the modification of a fuel supply system in an engine to application of the DME fuel because of DME fuel properties. So, in this study, a DME high pressure pump for a common-rail fuel supply system has been composed and the test results of the pump have been presented. As the results of the tests, it is confirmed that DME pump inlet pressure, pump speed and common-rail pressure effects on the volumetric efficiencies of the pump. Finally, it is defined that the optimum plunger volume of a DME pump has to be extended to the minimum 150% compared to a Diesel pump plunger volume considering DME fuel properties and volumetric efficiencies characteristics at same specifications of the high pressure pump.

Study on the Combination of In-situ Chemical Oxidation Method by using Hydrogen Peroxide with the Air-sparging Method for Diesel Contaminated Soil and Groundwater (과산화수소를 이용한 현장원위치 화학적 산화법과 공기분사법(Air-sparging)을 연계한 디젤 오염 토양/지하수 동시 정화 실내 실험 연구)

  • Kim, Nam-Ho;Kim, In-Su;Choi, Ae-Jung;Lee, Min-Hee
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.6
    • /
    • pp.8-17
    • /
    • 2006
  • Laboratory scale experiments were performed to investigate the removal efficiency of the in-situ chemical oxidation method and the air-sparging method for diesel contaminated soil and groundwater. Two kinds of diesel contaminated soils (TPH concentration : 2,401 mg/kg and 9,551 mg/kg) and groundwater sampled at Busan railroad station were used for the experiments. For batch experiments of chemical oxidation by using 50% hydrogen peroxide solution, TPH concentration of soil decreased to 18% and 15% of initial TPH concentration. For continuous column experiments, more than 70% of initial TPH in soil was removed by using soil flushing with 20% hydrogen peroxide solution, suggesting that most of diesel in soil reacted with hydrogen peroxide and degraded into $CO_2$ or $H_2O$ gases. Batch experiment for the air-sparging method with artificially contaminated groundwater (TPH concentration : 810 mg/L) was performed to evaluate the removal efficiency of the air-sparging method and TPH concentration of groundwater decreased to lower than 5 mg/L (waste water discharge tolerance limit) within 72 hours of air-sparging. For box experiment with diesel contaminated real soil and groundwater, the removal efficiency of air-sparging was very low because of the residual diesel phase existed in soil medium, suggesting that the air-sparging method should be applied to remediate groundwater after the free phase of diesel in soil medium was removed. For the last time, the in-situ box experiment for a unit process mixed the chemical oxidation process with the air-sparging process was performed to remove diesel from soil and groundwater at a time. Soil flushing with 20% hydrogen peroxide solution was applied to diesel contaminated soils in box, and subsequently contaminated groundwater was purified by the air-sparging method. With 23 L of 20% hydrogen peroxide solution and 2,160 L of air-sparging, TPH concentration of soil decreased from 9,551 mg/kg to 390 mg/kg and TPH concentration of groundwater reduced to lower than 5 mg/L. Results suggested that the combination process of the in-situ hydrogen peroxide flushing and the air-sparging has a great possibility to simultaneously remediate fuel contaminated soil and groundwater.

Self-driving quarantine robot with chlorine dioxide system (이산화염소 시스템을 적용한 자율주행 방역 로봇)

  • Bang, Gul-Won
    • Journal of Digital Convergence
    • /
    • v.19 no.12
    • /
    • pp.145-150
    • /
    • 2021
  • In order to continuously perform quarantine in public places, it is not easy to secure manpower, but using self-driving-based robots can solve problems caused by manpower. Self-driving-based quarantine robots can continuously prevent the spread of harmful viruses and diseases in public institutions and hospitals without additional manpower. The location of the autonomous driving function was estimated by applying the Pinnacle filter algorithm, and the UV sterilization system and chlorine dioxide injection system were applied for quarantine. The driving time is more than 3 hours and the position error is 0.5m.Soon, the stop-avoidance function was operated at 95% and the obstacle detection distance was 1.5 m, and the automatic charge recovery was charged by moving to the charging cradle at the remaining 10% of the battery capacity. As a result of quarantine with an unmanned quarantine system, UV sterilization is 99% and chlorine dioxide is sterilized more than 95%, which can contribute to reducing enormous social costs.