• Title/Summary/Keyword: 분배실

Search Result 44, Processing Time 0.033 seconds

A Case Study on the Spatial Configuration and Allocation of Catering Facilities of Newly-Built Elementary Schools in Sejong City (세종시 신설초등학교의 조리장 공간구성과 면적에 관한 사례 연구)

  • Song, Byung-Ha
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.433-442
    • /
    • 2017
  • This study consists of five case studies of the catering facilities of newly-built elementary schools' in Sejong City, regarding the spatial configuration and allocation. The analysis indicated that the space allocated in the cooking area in the five schools compared to the standard was as follows: School A; 99.2%, B; 91.1%, C; 81.4%, D; 110.8%, E; 88.1%. Accordingly, the cooking area was close to, or slightly above the standard; nevertheless, other areas in the facilities were not allocated sufficient space and were not appropriately planned. Among the other findings, the receiving areas of three schools were not even planned, and the receiving works were carried out in the pre-preparation area. Considering the flow of the dish-washing process, the width of the room should be at least 3.6 meters with a passage width of 1.6 meters, and easy access to the cooking and dining areas must be equipped. An interview with all five supervisors showed that most complaints focused on the cooking and dishwashing areas, whereas there were none in the storage and workers' area. The result highlights the importance of the cooking and dishwashing areas as the main functions in catering facilities, and future planning strategies should consider this aspect.

Cluster-based Pairwise Key Establishment in Wireless Sensor Networks (센서 네트워크에서의 안전한 통신을 위한 클러스터 기반 키 분배 구조)

  • Chun Eunmi;Doh Inshil;Oh Hayoung;Park Soyoung;Lee Jooyoung;Chae Kijoon;Lee Sang-Ho;Nah Jaehoon
    • The KIPS Transactions:PartC
    • /
    • v.12C no.4 s.100
    • /
    • pp.473-480
    • /
    • 2005
  • We can obtain useful information by deploying large scale sensor networks in various situations. Security is also a major concern in sensor networks, and we need to establish pairwise keys between sensor nodes for secure communication. In this paper, we propose new pairwise key establishment mechanism based on clustering and polynomial sharing. In the mechanism, we divide the network field into clusters, and based on the polynomial-based key distribution mechanism we create bivariate Polynomials and assign unique polynomial to each cluster. Each pair of sensor nodes located in the same cluster can compute their own pairwise keys through assigned polynomial shares from the same polynomial. Also, in our proposed scheme, sensors, which are in each other's transmission range and located in different clusters, can establish path key through their clusterheads. However, path key establishment can increase the network overhead. The number of the path keys and tine for path key establishment of our scheme depend on the number of sensors, cluster size, sensor density and sensor transmission range. The simulation result indicates that these schemes can achieve better performance if suitable conditions are met.

Development of Sub-scale Combustor for a Liquid Rocket Engine Using Swirl Injector with External Mixing (외부혼합 와류분사기를 장착한 액체로켓엔진용 축소형 연소기 개발)

  • Han, Yeoung-Min;Kim, Seung-Han;Seo, Seong-Hyeon;Lee, Kwang-Jin;Kim, Jong-Gyu;Seol, Woo-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.10
    • /
    • pp.102-111
    • /
    • 2004
  • The procedure of design and manufacture of sub-scale combustor using bipropellant swirl injector with external mixing for a liquid rocket engine are described. The results of cold flow test, ignition test and combustion test of the sub-scale combustor are also given in this paper. The sub-scale combustor uses liquid oxygen(LOx) and kerosene as propellants and has a injector head, an ablative material combustor wall and a water cooled nozzle. The injector head has LOx manifold, fuel manifold, fire face plate, one center swirl injector and 18 main swirl injectors. The cold flow, ignition and combustion tests were successfully performed without damage of combustor. Results of hot firing tests show that combustion efficiency meets the target of design and operations of start and stop cyclogram are stable and high frequency combustion instability does not occur.

A Study on Hydraulic Modifications of Low-Pressure Membrane Inlet Structure with CFD and PIV Techniques (CFD와 PIV 기법을 이용한 저압막 유입부 수리구조 개선에 관한 연구)

  • Oh, Jeong Ik;Choi, Jong-Woong;Lim, Jae-Lim;Kim, Donggil;Park, No-Suk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.11
    • /
    • pp.607-618
    • /
    • 2015
  • This study was conducted to suggest hydraulic modification for improving evenness of inlet flow distribution into side stream type low-pressure MF (microfiltration) module using CFD (computational fluid dynamics) simulation and PIV (particle image velocimetry) techniques. From the results of CFD simulation for various typed inlet structure, it was investigated that installing internal orifice baffle in inlet the distribution channel could improve the evenness of inlet flow distribution over about 40%. Also, from the results of PIV measurements which were carried out for verifying the CFD simulation, it was observed that the momentum of the water body coming from the opposite side of the inlet was relatively larger. This momentum would generate strong shear force in the near of inlet side wall. On the other hands, occurrence of dead zone and eddy flow was confirmed in the opposite side.

Estimation of the First Modal Participation Factor of a Shear Building under Earthquake Load (지진하중을 받는 전단구조물의 1차 모드참여계수 산정)

  • Hwang, Jae-Seung;Kim, Hong-Jin;Kang, Kyung-Soo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.1 s.41
    • /
    • pp.25-32
    • /
    • 2005
  • Seismic load is distributed to modes of a structure through the modal participation factor(MPF). The modal participation factor is essential to analyze structural response under earthquake load. MPF of a real structure differs from that of analytical mathematical model due to the error induced from analytical assumptions and during the construction. In this study, an identification method is proposed to calculate the 1st MPF of real structure based on $H^{\infty}$ optimal model reduction. The MPF is obtained from the relationship between observability and controllability matrices realized from system identification and those of a prototype 2-degree state space model. The proposed method is verified thorough numerical examples.

Individual and Organizational Effect of IT Human Resources on Career Satisfaction, Career Prospects and Career Commitment (IT인력의 개인과 조직특성이 경력만족, 경력전망 및 경력몰입에 미치는 영향에 관한 연구)

  • Park, Se-Youn;Cho, Nam-Wook
    • The Journal of Society for e-Business Studies
    • /
    • v.14 no.3
    • /
    • pp.87-105
    • /
    • 2009
  • This paper investigates the effect of individual and organizational factors of IT human resources on their career satisfaction, career prospect and career commitment. In this paper, a quantitative method was used to study the effect; A survey of IT developers and IT related employees was conducted. Factor analyses and regression analyses were used in verifying the consequences. As a result, followings were found:From the individual perspective, the self-esteem of IT human resource showed the most significant effect on career satisfaction and the desire for career success had significant effect on career commitment. Among organizational factors, the fairness of evaluation showed the most significant effect on both career prospect and career commitment. It has been also shown that organizations should provide more opportunities for individual growth to enhance career prospect. Finally, career prospect affected career satisfaction; Both career satisfaction and career prospect showed effect on career commitment. This research provided guidelines in enhancing the career commitment of IT human resources, thereby effectively managing IT human resources.

  • PDF

Development Status of Korea Accelerated Loading and Environment Simulator (KALES) (한국형 포장가속시험시설의 개발현황)

  • Yang, Seong-Cheol;Yu, Tae-Seok;Eom, Ju-Yong
    • International Journal of Highway Engineering
    • /
    • v.2 no.2
    • /
    • pp.139-148
    • /
    • 2000
  • Currently existing Accelerated Pavement Testing (APT) systems developed in several countries have been employed mainly to test the performance of asphalt pavement. Meanwhile, the length of concrete pavement is similar to that of asphalt pavement in expressways of Korea. and is expected to increase due to its durability and compatibility to our weather condition. To meet the society's demand of having our own APT system which can examine the long-term performance of concrete pavement, a contract study to develop Korea Accelerated Loading and Environment Simulator (KALES) for concrete pavement has been performed for 3 years from 1997 through 1999. Through the project, a detailed design was Peformed for the KALES system in which the entire structure of KALES, loading mechanism, wandering mechanism, suspension system, driving system were proposed. Also in advance to design a full-scale KALES system, a sample scale model was manufactured and tested for operating motion and force distribution. It is evident that the proposed prototype KALES system will provide higher degree of traffic simulation and durable operation, based on the satisfactory fatigue analysis.

  • PDF

The Effect of International Diversification on Dividend Payout ratio and Dividend Yield Rate (국제적 다각화가 배당성향 및 배당수익률에 미치는 효과 분석)

  • Choi, Yu-Jeong;Lim, Jae-Hwan
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.12
    • /
    • pp.187-197
    • /
    • 2020
  • In this study, how international diversification of domestic companies increases corporate profits and increases the dividend income of paid-in capital investors, who provided the basis for corporate business activities in the process of distributing profits. I tried to find out if it had an effect. An empirical analysis was conducted using a fixed-effect model for companies with settlements at the end of December listed on the domestic securities market from 2011 to 2018. It was confirmed that the higher the level of international diversification of individual companies, the higher the company's dividend payout ratio and dividend yield. This means that companies can steadily expand corporate profits and dividend yield of shareholders by securing new overseas markets through international diversification, it can be seen that a company's international diversification strategy can contribute to the increase of corporate value by increasing the company's dividend payout ratio by increasing dividendable profit.

Modelling Water Loss Control Interventions in Urban Water System from a Water-Energy-Environment Nexus Perspective (물-에너지-환경 넥서스 관점의 도시 물순환 시스템 내 물 손실 관리 방안 모델링)

  • Choi, Seo Hyung;Shin, Eunher
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.32-32
    • /
    • 2021
  • 넥서스는 물, 에너지, 식량, 토지, 기후 및 환경 등의 부문 간 연관성과 상호의존성을 나타내며, 이러한 넥서스 개념은 최근에 학계와 정책결정자들에게 많은 관심을 받고 있다. 더 나아가 넥서스 관점의 도입으로 단일 부문별로 자원을 관리하는 기존의 정책 결정 체계의 한계를 극복하고, 관련 있는 부문 간의 시너지와 트레이드오프를 고려한 지속가능한 발전을 위한 의사 결정이 가능하게 되었다. 일반적으로 취수-도수-정수처리-송수-분배·급수-물이용-하수집수-하수처리-물재이용으로 구성되는 도시 물순환 시스템에서 공급과정에서 발생되는 물손실 관리를 위한 전략 및 프로그램은 물부문 만에서 평가를 통해 수립되고 있다. 본 연구에서는 시스템 다이나믹스(System Dynamics)를 적용하여 물, 에너지 및 환경 부문을 동시에 고려한 도시 물순환 시스템 모델을 개발하여, 넥서스 관점에서의 합리적인 도시 물손실 관리 방안을 도출하고자 하였다. 그리고 모델 내 부문 간 자원의 사용량 및 이동량의 정량화를 위해 물, 에너지, 환경 지표로 각각 물발자국(Water Footprint), 총 에너지 사용량(Total Energy Use) 및 탄소발자국(Carbon Footprint)이 적용되었다. 개발된 모델을 3개의 도시 에너지 인텐시티 현황(낮음, 보통, 높음)과 4개의 물손실 현황(낮은 물손실, 높은 물손실&낮은 명목손실비, 높은 물손실&보통 명목손실비, 높은 물손실&높은 명목손실비)을 고려한 12개의 시나리오에 적용하여 분석하였다. 그 결과 기존의 경제적인 측면 중심의 의사결정 과정에서는 명목손실이 물손실 관리 전략 수립 및 적용의 우선순위였으나, 넥서스 관점에서는 실손실 부분의 개선이 중요함을 알 수 있었다. 또한, 도시의 단위 물공급 에너지 인텐시티가 자원 사용 및 이동에 큰 영향을 미치는 것으로 분석되어서, 넥서스 관점의 의사결정시 사전적으로 분석해야 하는 중요 항목인 것으로 도출되었다. 이와 같은 범용적이고 포괄적인 도시 물순환 물-에너지-환경 넥서스 모델을 통해, 지속가능하고, 체계적이며, 구체적이고, 실현가능한 넥서스관점의 물손실 관리가 가능할 것으로 판단된다.

  • PDF

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF