• Title/Summary/Keyword: 분무입경

Search Result 163, Processing Time 0.024 seconds

An experiment for comparison of an imaging measurement technique for a water spray with a phase-Doppler measurement technique (PDPA와 화상처리법(PMAS)의 비교를 위한 분무 측정 실험)

  • Jurng, J.;Lee, G.W.
    • Journal of ILASS-Korea
    • /
    • v.3 no.1
    • /
    • pp.1-9
    • /
    • 1998
  • Two measurement techniques of droplet sizing, an imaging technique(PMAS) and a phase-Doppler measurement technique (PDPA), have been compared using a water spray from a pressurized-type swirl nozzle. The result showed that SMD measured by PDPA was larger than that measured by PMAS by about 40 %. Such discrepancy of SMD could be explained by the fact that the light signal intensity used by PDPA can be biased towards larger particles. On the other hand there could be lower opportunity to capture the images of the large particles with PMAS, since the large particles could be out of sight due to their high speed.

  • PDF

A Numerical Analysis on the Spray Characteristics at Different Injection System Parameters in a Common-rail Diesel Engine (연료분사계 변수의 변화에 따른 커먼레일 디젤엔진의 분무특성에 관한 수치적 분석)

  • Lee, Suk-Young;Jeon, Chung-Hwan
    • Journal of ILASS-Korea
    • /
    • v.15 no.1
    • /
    • pp.8-16
    • /
    • 2010
  • This paper present the diesel spray characteristics at different injection system parameters in a HSDI diesel engine. The spray characteristics was calculated by the coupled simulation of fuel injection system model and three-dimensional KIVA-3V code with TAB spray model. The relevant injection parameters are accumulator volume, control chamber initial volume, control orifice diameter, needle valve diameter and nozzle chamber initial volume, etc. Parametric investigation with respect to twelve relevant injection parameters showed that there was a significant advantage in varying control chamber initial volume, control chamber orifice diameter, and nozzle chamber orifice diameter with respect to effect the SMD and fuel injection speed. Consequently, in order to design the fuel injection system for spray characteristics, it seems reasonable to suppose to be optimized the fuel injection system.

Development of the low Emission type Fuel Feeding System for Diesel Automobile I (Characteristics and Spray of Emulsified Fuel) (디젤자동차의 저공해형 연료공급장치 개발 I (유화연료의 특성 및 분무거동))

  • Cho, S.C.;Yoon, M.K.;Ryu, J.I.
    • Journal of ILASS-Korea
    • /
    • v.2 no.3
    • /
    • pp.8-16
    • /
    • 1997
  • Ta investigate characteristics and spray of emulsified fuet we are mixed water with diesel oil using ultrasonic energy fuel feeding system. Separation ratio of emulsified fuel was shown good condition that of water content is small and longer ultrasonic energy adding time. Viscosity of emulsified fuel increased 79% with addition to water content and surface tension increased 1.6% in comparision to pure diesel oil. The SMD of emulsified fuel adding ultrasonic energy decreased with 3% in comparision to pure diesel oil. With increasing 5, 10% water content the SMD decreased 15.6, 20.1% in comparision to pure diesel oil. The mind-explosion was investigated with 4step.

  • PDF

Effect of Ambient Conditions on Spray Behavior of Gasoline Injector (가솔린 분무 거동에 미치는 분위기 조건의 영향)

  • 이창식;이기형;최수천;권상일
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.2
    • /
    • pp.27-32
    • /
    • 2000
  • The main objective of this work is to investigate the effect of ambient conditions on the spray behavior and spray characteristics of high-pressure fuel injector. For this purpose, the effects of ambient pressure and temperature on the spray characteristics have been studied by applying the analysis of visualization system and phase Doppler particle analyzer. In this experiment, the visualization of spray behavior was performed under various ambient gas conditions and injection parameters such as gas temperature, ambient pressure, injection pressure of injector, and axial distance from the nozzle tip. Based on the investigation results, the spray tip penetration and spray width decrease with the increase of ambient gas pressure in the spray chamber. The effects of the spray parameters on the microscopic characteristics of gasoline spray were discussed.

  • PDF

Spray characteristics on mixing region scale of twin fluid atomizer (이류체 분사노즐의 혼합영역 형상에 따른 분무특성)

  • 김병문;김혁주;이충원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.2147-2159
    • /
    • 1991
  • The effects of principal dimensions of internal mixing twin-fluid atomized and operating conditions on the atomizing characteristics are experimentally investigated. The tests are conducted over the wide range of air/liquid ratio to predict influences of the diameter and length of nozzle, contacting angle between air and liquid in the mixing chamber, and air orifice diameter on the mean drop size(SMD), spray angle, distribution of drop size, and spray dispersion, And also, initial distribution of liquid column by air stream within the mixing chamber are observed through the transparent nozzles. A He-Ne laser particle sizer(MALVERN Model 2604) was used to measure the Sauter.s mean diameter( $D_{321}$) and droplet sizes distribution. In this experiment the air/liquid ratio, mixing length and nozzle diameter have a great influence on SMD, spray angle, droplet sizes distribution and spray dispersion.

Spray Pattern Analysis of the Injector in a Small Liquid-Rocket Engine (소형 액체로켓엔진 인젝터의 분무패턴 분석)

  • Jung, Hun;Kim, Jin-Seok;Kim, Jeong-Soo;Park, Jeong;Kim, Sung-Cho;Jang, Ki-Won
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.146-149
    • /
    • 2006
  • Spray characteristics of an injector employed in mono-propellant hydrazine thrusters were investigated by PIV(particle image velocimetry) and LDA/PDA(laser/phase Doppler anemometry) techniques. The instanteneous plane image data captured by PIV measurement were examined in order to judge a pass-fail criteria of spray injection performance according to the specific pressure supplied. LDA/PDA technique were also applied to measure the velocity and droplet size of spray were not obtained from PIV measurement. The objective of this experimental study was the clear understanding of spray characteristics as well as the derivation of injector performance to understand clearly the spray characteristics by comparing the both results.

  • PDF

Spray Characteristics of the Pressure Swirl Injector for the APU Gas Turbine Engine (APU 가스터빈엔진 압력식 스월인젝터의 분무특성)

  • Choi, Chea-Hong;Choi, Seong-Man;Lim, Byeong-Jun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.359-364
    • /
    • 2007
  • Spray characteristics of the APU gas turbine engine were investigated. In order to understand blow out phenomena of the APU engine, we performed fuel spray test. In the test, four operating conditions such as sea level idle, sea level max power, 20,000 feet idle, 20,000 feet max power were used as spray experimental conditions. PDPA(phase Doppler Particle Analyzer) was used for measuring the particle diameter and velocity. Also spray visualization was performed by using ND-YAG sheet laser beam. From the test result, in the case of 20,000 feet idle condition, SMD is about 100 ${\mu}m$ and maximum particle velocity is about 10 m/s. For the flame stability, spray quality should be improved at 20,000 feet idle condition.

  • PDF

Improvement of Image Processing Algorithm for Particle Size Measurement Using Hough Transform (Hough 변환을 이용한 입경 측정을 위한 영상처리 알고리즘의 개선)

  • Kim, Yu-Dong;Lee, Sang-Yong
    • Journal of ILASS-Korea
    • /
    • v.6 no.1
    • /
    • pp.35-43
    • /
    • 2001
  • Previous studies on image processing techniques for panicle size measurement usually have focused on a single panicle or weakly overlapped particles. In the present work, the image processing algorithm for particle size measurement has been improved to process heavily-overlapped spherical-particle images. The algorithm consists of two steps; detection of boundaries which separate the images of the overlapped panicles from the background and the panicle identification process. For the first step, Sobel operator (using gray-level gradient) and the thinning process was adopted, and compared with the gray-level thresholding method that has been widely adopted. In the second, Hough transform was used. Hough transform is the detection algorithm of parametric curves such as straight lines or circles which can be described by several parameters. To reduce the measurement error, the process of finding the true center was added. The improved algorithm was tested by processing an image frame which contains heavily overlapped spherical panicles. The results showed that both the performances of detecting the overlapped images and separating the panicle from them were improved.

  • PDF

Characteristic of Tractor Attachment Boom Sprayer Nozzle (트랙터 부착 붐 방제기 노즐 분무특성)

  • Kang, TaeGyoung;Kim, Sungwoo;Kim, Youngkeun;Lee, Sanghee;Choi, Yong;Jun, Hyeonjong;Choi, Ilsoo;Kim, Hyeonggon
    • Journal of ILASS-Korea
    • /
    • v.21 no.4
    • /
    • pp.195-199
    • /
    • 2016
  • Spraying of nozzles and design of tractor-attached boom sprayers have been studied for analysis of liquid spraying features. The following conclusions have been drawn. At all pressures, twin flat spray tips was finer than flat spray tips. A fine spray with VMD of 101 to 200 appeared at 1.5MPa. So, it was selected as the boom sprayer nozzle. In spraying uniformity analysis, Type B was proven to have more uniformity than Type A and Type C at 52.0 cm attached distance. Type A and Type C were proven to have more uniformity than Type B at 58.5 cm attached distance. It is concluded that these results reflect atomizing characteristics of nozzles during pest control with tractor-attached boom sprayer. Therefore, optimum setting will be putting Type C with 58.5 cm distance.

Effects of spray nozzles on the structure of twin spray (이중 분무의 중첩 구조에 미치는 분무 노즐의 영향)

  • Jurng, J.S.;Park, C.B.;Im, K.S.
    • Journal of ILASS-Korea
    • /
    • v.1 no.3
    • /
    • pp.51-59
    • /
    • 1996
  • An experiment was carried out on the structure of twin spray from pressurize-swirl nozzles, in order to investigate the effect of different size of spray nozzles on the characteristics of the overlap of two single sprays, for example, mean diameter, number density, and spatial distribution of flow rate. Using image processing method, the distributions of size and velocity of droplets of a single spray and twin spray were measured and compared to investigate the overlapping effect of two identical sprays. Comparing experimental results from a twin-spray with those from two-single sprays shows that the flow rate distribution of the twin-spray was concentrated around the midst of the overlapping region of two sprays. In this region, Sauter mean diameter (SMD) did not change much in the twin spray from 6032 nozzles, but it was smaller by 10 micrometers in the twin-spray than two-single sprays from 60063 nozzles. In spite of large difference in Weber numbers of the colliding sprays between the 60063 and 6032 nozzles, the phenomena did not have a big change in the overlapping region of twin spray. This shows that in the collision between droplets from two single spray in the overlapping region to cause the disruption of droplets, the size distribution of spray droplets was also important as well as Weber number.

  • PDF