• Title/Summary/Keyword: 분무법

Search Result 410, Processing Time 0.028 seconds

Characterization and Improvement of Dissolution Rate of Solid Dispersion of Celecoxib in PVP K30/Eudragit EPO (PVP K30/Eudragit EPO에 의한 셀레콕시브 고체분산체의 용출률 향상 및 특성)

  • Jeon, Dae Yeon;Jang, Ji Eun;Lee, Jeong Hwan;Yang, Jae Won;Park, Sang Mi;Lim, Dongkwon;Khang, Gilson
    • Polymer(Korea)
    • /
    • v.38 no.4
    • /
    • pp.434-440
    • /
    • 2014
  • We prepared nanoparticles containing insoluble celecoxib by the method of solid dispersions using a spray dryer to improve solubility of celecoxib. We used PVP K30 and Eudragit EPO as water-soluble carriers for the solid dispersion, and poloxamer 407 as a surfactant. Characterization of celecoxib solid dispersion was performed by scanning electron microscope (SEM), differential scanning calorimetry (DSC), X-ray diffraction (XRD) and Fourier-transform infrared spectroscopy (FTIR). The results of SEM, DSC and XRD demonstrated that celecoxib is amorphous in solid dispersion. The dissolution rate measured in intestinal juice showed that the method of solid dispersion improved celecoxib solubility as compared with a conventional drug (Celebres$^{(R)}$). In conclusion, solid dispersion formulation prepared by a spray dryer would improve the solubility of celecoxib in oral administration.

Fabrication of Sm0.5Sr0.5CoO3 cathode films for intermediate temperature SOFCs by electrostatic spray deposition (정전분무증착법에 의한 중온형 고체산화물 연료전지를 위한 Sm0.5Sr0.5CoO3 양극막의 제조)

  • Park, In-Yu;Im, Jong-Mo;Jung, Yeong-Geul;Shin, Dong-Wook
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.2
    • /
    • pp.69-73
    • /
    • 2010
  • The microstructural change of the $Sm_{0.5}Sr_{0.5}CoO_3$ (SSC) electrode for a cathode material of solid oxdie fuel cells (SOFCs) deposited by the electrostatic spray deposition (ESD) technique was characterized. Samarium chloride hexahydrate $(SmCl_3{\cdot}6H_2O)$, strontium chloride hexahydrate $(SrCl_2{\cdot}gH_2O)$, cobalt nitrate hexahydrate $(Co(No_3)_2{\cdot}6H_2O)$ as starting materials and methyl alcohol as solvent were used to make precursor solution. The suitable porous SSC films for a cathode of SOFCs were deposited on Si substrate and it is observed that the microstructure was strongly dependent on processing parameters such as deposition time, substrate temperature, and applied voltage. Scanning Electron Microscope (SEM) and X-ray Diffractometer (XRD) measurement were used to investigate the microstructure and crystallinity of the SSC films. The ESD technique is shown to be an efficient method in which the SOFCs' cathode film can be fabricated with the desired phases and microstructure.

Evaluation of corrosion resistance for various coated steel sheets by different types of corrosion test method (내식성 코팅 강재의 부식시험 종류 별 내식성 비교 평가)

  • Park, Jae-Hyeok;Hwang, Seong-Hwa;Park, Jun-Mu;Eom, Jin-Hwan;Yun, Yong-Seop;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.163-163
    • /
    • 2017
  • 철강재는 대량 생산이 가능하여 경제성이 뛰어나고 기계적 성질도 우수하여 다양한 산업 분야에서 널리 사용되고 있다. 그러나 철강재는 부식 환경에 취약하기 때문에 그 용도에 따라 다양한 내식성을 부여하는 표면처리를 적용하고 있다. 이러한 철강재에 대한 내식성 표면처리로는 용융아연도금(HDG)과 용융알루미늄도금(HDA)이 우수한 내식성과 다양한 특성으로 널리 사용되고 있으며 아연과 알루미늄을 접목시킨 갈바륨(GL)도금 또한 우수한 내식성 코팅으로 알려져 있다. 또한 최근에는 기존 용융아연도금에 알루미늄(Al) 과 마그네슘(Mg)을 첨가한 3원계 도금강판이 개발되어 기존 용융도금강판 대비 고내식 코팅으로 알려져 있으며 그 적용은 점차 확대되고 있는 추세이다. 일반적으로 이와 같은 강판소재의 내식성 평가에 대해서는 실제 사용할 환경에 폭로하여 비교-시험 하는 것이 가장 확실하고 신뢰도가 높은 방법이다. 그러나 이러한 방법은 경우에 따라 수년에서 수십년에 이르는 장시간이 소요된다. 그러므로 이 방법을 대체하기 위한 각종 가속적 부식 시험들이 널리 적용되고 있다. 즉, 그 목적이나 용도에 따라 염수분무(SST), 침지(Immersion) 및 전기화학적 분극(Polarization) 등 실내에서 부식 시험 하는 방법이 사용되고 있다. 한편, 이러한 부식 가속 시험들은 실제 외부에서 폭로 시험한 결과와의 상관성이 불명확한 경우가 많아 종종 해석에 어려움을 갖고 있는 실정이다. 또한 이 시험 방법들은 동일 재료를 시험하더라도 시험방법의 차이에 따라 부식요인이나 해석방법이 다르므로 인해 그 내식성 결과가 다르게 나타날 수 있다. 그 중 시험목적에 따라 전기화학적 분극 또는 임피던스 분광법(EIS)과 건조 및 습윤 등의 부식 환경 인자들을 적용한 복합부식시험(CCT) 방법은 근사한 대안으로 주목받고 있다. 하지만 이들 시험 또한 실제 부식 환경과는 여러 환경 및 요인들이 다르기 때문에 그 시험방법에 따라 목적하는 시험 결과가 상이하게 나타날 수 있어 해석-평가 하기에 종종 곤란을 갖는다. 이에 따라 최근에는 재현성이 우수하고 실제 부식 환경을 유사하게 모사할 수 있는 내식성 시험과 해석-평가에 대한 내용이 주요한 과제로 사료되고 있다. 본 연구에서는 다양한 내식성 코팅 강판소재들에 대하여 염수분무(SST), 복합부식(CCT), 갈바닉 시험, EIS 시험을 통하여 부식시험 종류 및 시험 환경, 코팅 소재 별 부식경향을 비교-분석하고자 하였다. 또한 이들 부식 진행과정에서는 미세구조관찰(SEM), 결정구조 분석(XRD) 및 원소조성 분석(EPMA)을 통해 다양한 조건에 따른 강판소재들의 부식경향을 비교-평가하고, 실제 환경과의 상관성 및 가속관계를 도출하고자 하였다.

  • PDF

Physicochemical Property and Release Behavior of Ibuprofen Solid Dispersion with Cellulose Acetate Prepared with Various Methods (이부프로펜과 셀룰로오스아세테이트의 고체분산체 제조방법에 따른 물리화학적 성질 및 용출 특성)

  • Lee, Eun-Yong;Oh, Myeong-Jun;Kim, Se-Ho;Seong, Kyong-Yeol;Lee, Young-Hyun;Kim, Soo-Jin;She, Han-Sol;Lee, Dong-Won;Khang, Gil-Son
    • Polymer(Korea)
    • /
    • v.35 no.2
    • /
    • pp.113-118
    • /
    • 2011
  • Solid dispersion is used to improve the solubility of water-insoluble drug. Release properties depend on the characteristics of polymer and the physicochemical properties of solid dispersion. In this study the solid dispersions of ibuprofen and cellulose acetate were prepared using spray-drying and rotary evaporation. The physicochemical properties of the solid dispersions were analyzed by SEM, XRD, DSC, and FTIR. The hydrophilicity of polymer was analyzed by measuring the contact angle of water. The results of DSC and XRD analysis demonstrated that the crystallinity of ibuprofen was changed by solid dispersion preparation. The results of contact angle showed that hydrophilicity was proportional to polymer content. Release profile showed that for solid dispersion. the release rate of ibuprofen decreased as polymer content increased in intestinal juice (pH 6.8). The dissolution rate of ibuprofen was improved with increasing polymer content in gastric juice (pH 1.2).

Characterization and Improved Dissolution Rate of Aceclofenac Solid Dispersion (아세클로페낙 고체분산체의 특성 및 용출률 개선)

  • Kim, Yun-Tae;Park, Hyun-Jin;Lee, Young-Hyun;Hong, Hee-Kyung;Eom, Shin;Kim, Yong-Ki;Lee, Eun-Yong;Choi, Myoung-Gyu;Lee, Jae-Jun;Cho, Yong-Baik;Khang, Gil-Son
    • Polymer(Korea)
    • /
    • v.33 no.6
    • /
    • pp.596-601
    • /
    • 2009
  • We prepared nanoparticles containing insoluble aceclofenac by the method of solid dispersions using spray dryer to improve solubility of aceclofenac. We used PVP-K30 as a water soluble carrier for the solid dispersion and poloxamer as a surfactant. Characterization of aceclofenac solid dispersion was performed by SEM, DSC, XRD and FT-IR. The results of SEM, DSC and XRD demonstrated that aceclofenac is amorphous in solid dispersion. The formation of salt by hydrogen bond between aceclofenac and PVP K-30 was confirmed by FT-IR. The dissolution rate measured in intestinal juice showed the method of solid dispersion improved aceclofenac solubility as compared with a conventional drug($Airtal^{(R)}$). In conclusion, the method of solid dispersion using spray dryer would improve solubility of aceclofenac in oral administration.

Sibutramine Release Behavior from Microspheres Prepared by Spray-Dry Method (분무건조 방법으로 제조된 미립구에서 Sibutramine의 방출거동)

  • Park, Jung-Soo;Oh, Jung-Soo;Oh, Jae-Min;Kim, Yun-Tae;Lee, Jun-Hee;Mo, Jong-Hyun;Lee, Hai-Bang;Khang, Gil-Son
    • Polymer(Korea)
    • /
    • v.32 no.3
    • /
    • pp.193-198
    • /
    • 2008
  • Sibutramine is a highly crystalline and poorly water soluble drug as the appetite depressant for obesity treatment. In order to increase water solubility of sibutramine, microspheres including sibutramine were prepared by solid dispersion method using a spray dryer. The crystallinity and morphology of the prepared microspheres were confirmed by SEM and XRD. The morphology of micro spheres has gradually changed into spherical shape as increasing evaporation rate of solvent. According to XRD analysis, crystallinity of sibutramine in micro spheres was decreased by below 10%. Release behavior of microspheres was investiaged at pH 1.2, pH 6.8, and solubility of the sibutramine was significantly different depending on pH. The hard capsule showed fast release of sibutramine comparing with the tablet. These results demonstrated that the pharmaceutical preparation is able to control the release behaviors.

Evaluation of Resistance to Colletotrichum acutatum in Pepper Genetic Resources (고추 유전자원의 탄저병(Colletotrichum acutatum) 저항성 평가)

  • Kim, Sang-Gyu;Ro, Na-Young;Hur, On-Sook;Ko, Ho-Cheol;Gwag, Jae-Gyun;Huh, Yun-Chan
    • Research in Plant Disease
    • /
    • v.18 no.2
    • /
    • pp.93-100
    • /
    • 2012
  • Resistance of pepper (Capsicum spp.) to anthracnose (Colletotrichum acutatum) was evaluated during regeneration of Capsicum spp. in National Agrobiodiversity Center. Disease severity of 896 pepper accessions (430 accessions of C. annuum, 219 accessions of C. baccatum, 14 accessions of C. chacoense, 153 accessions of C. chinense, 70 accessions of C. frutescens, 2 accessions of C. pubescens, and unidentified 8 accessions) was investigated at 14 days after inoculation in $28^{\circ}C$ humid chamber. Forty nine accessions of pepper germplasm were resistant to C. acutatum. Among them, nine accessions were highly resistant to C. acutatum without wounding spray inoculation. Four accessions belonged to the species C. baccatum, one accession to C. chacoense, and four accessions to C. frutescens. Forty two resistant candidate accessions were inoculated with pin-prick wounding using a syringe needle. Five accessions were resistant as a less than 3% of disease severity to C. acutatum with wounding inoculation 5 days after inoculation. All resistant accessions were C. baccatum. These five pepper germplasm might be used as breeding resources for the anthracnose resistance breeding program.

Reconsideration and Conservational Scientific Diagnosis of Silla Stone Monument in Bongpyeong-ri, Uljin (울진 봉평리 신라비의 재판독과 보존과학적 진단)

  • Jo, Young-hoon;Lee, Chan-hee;Shim, Hyun-yong
    • Korean Journal of Heritage: History & Science
    • /
    • v.46 no.3
    • /
    • pp.48-67
    • /
    • 2013
  • This study was focused on the recognition of historical values and the establishment of conservation schemes for a Silla stone monument in Bongpyeong-ri, Uljin by combining the humanistic investigation of inscription reinterpretation and the scientific conservational diagnosis of deterioration. According to the investigation of inscription, a total of 13 letters were reconsidered compared to the preceding researches. Thus, the meaning and interpretation of previous inscription was partially changed. This monument is composed of gneissose leucogranite and the most suitable site as provenance of the stone would be the Jukbyeon seashore (2.1km). The site shows similar color, size and composition of minerals, gneissose structure and magnetic susceptibility as the Bongpyeong stone monument. This monument developed a structural crack (crack index 0.4) and a microcrack (crack index 2.0) along the gneissose structure. The horizontal strength is weaker than the vertical strength. Therefore, the cracks should be reinforced and treated. However, consolidating is not urgently needed because the total weathering grade by ultrasonic velocity shows the stage of moderate weathering(3,403m/s, 0.32). Also, the major problems of chemical deterioration are blackening (85.2%) with soil, iron oxide,rubbing mark, and salt crystals (17.3%) from the sea. Therefore, the contaminants and the salt crystals should be removed using pressure spray and pulp paper, while the application of poultice should be examined through clinical tests.

Microwave Absorbing Properties of Silver-coated Ni-Zn Ferrite Spheres Prepared by Electroless Plating (무전해 도금법에 의해 제조된 은 피복 Ni-Zn Ferrite Sphere의 전파흡수특성)

  • Kim, Jong-Hyuk;Kim, Jae-Woong;Kim, Sung-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.3
    • /
    • pp.202-206
    • /
    • 2005
  • The present investigation provides an electromagnetic radiation absorptive composition which comprises silver-coated ferrite microspheres dispersed in silicon rubber matrix for the aim of thin microwave absorber in GHz frequencies. Ni-Zn ferrite spheres with $50{\mu}m$ size in average were prepared by spray-drying and sintering at $1130^{\circ}C$. Conductive silver layer was plated on ferrite spheres by electroless plating. Conductive Ni-Zn ferrite sphere with uniform silver layer were obtained in the concentration of 10 g/L $AgNO_3$ per 20 g ferrite spheres. For this powder, electrical resistance is reduced as low as $10^{-2}\~10^{-3}\;\Omega$. The most sensitive material parameters with silver plating is real and imaginary parts of complex permittivity. The conductive Ni-Zn ferrite spheres have large values of dielectric constant. Due to this high dielectric constant of microspheres, matching thickness is reduced to as low as 2 mm at the frequency of 7 GHz, which is much thinner than conventional ferrite absorbers.

Accurate determination of chloramphenicol in meat by isotope dilution liquid chromatography mass spectrometry (ID-LC/MS) (동위원소희석 액체크로마토그래피-질량분석법을 이용한 육류 중 클로람페니콜의 정밀한 정량 분석에 관한 연구)

  • Song, Hye-Min;Kim, Byung-Joo;Jeong, Hyuk;Ahn, Seong-Hee
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.524-530
    • /
    • 2010
  • Chloramphenicol is one of the most effective antibiotics for treatment of food-producing animals for typhoid fever. However, it has been reported that it caused severe side effects such as aplastic anemia in human, therefore the use of chloramphenicol for food-producing animal is prohibited by European Union and other countries. In this study, the analytical method using isotope dilution liquid chromatography-mass spectrometry (ID-LC/MS) was established for accurate determination of chloramphenicol in meat. Chloramphenicol was extracted with ethylacetate from porcine and solid phase extraction cartridge was used for enhancing the recovery. The residue of chloramphenicol in porcine was analyzed using the liquid chromatography mass spectrometer (LC/MS) interfaced with electrospray ionization source. Analysis was performed in negative mode with selected reaction mornitoring mode at m/z 321${\rightarrow}$257 of $[M-H]^-$ ${\rightarrow}$ $[M-H-(HCOCl)]^-$ and m/z 326 ${\rightarrow}$ 262 channels for its isotope. The established method was tested using fortified samples at the level of 0.2 1, 10, $25\;{\mu}g$/kg and analytical results agreed with the gravimetrically fortified values within their uncertainties. This method was validated by analyzing a certified reference material, BCR 445, from IRMM (Institute for Reference Materials and Measurement). Our measurement values agreed with the certified value within their uncertainties. The uncertainty of our measured value was much lower than that the certified value from IRMM.