• Title/Summary/Keyword: 부하함수

Search Result 265, Processing Time 0.026 seconds

Improved instantaneous Following Control Function for High Power Factor PWM Matrix Converter (고역율 PWM 매트릭스 컨버터의 개선된 순시추종 제어함수)

  • Kim, Kwang-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.35-43
    • /
    • 2005
  • Matrix converters have been studied for eliminating dc link of conventional converter-inverter system, and various undulation strategy have been proposed. Therefore, matrix converter have no energy storage component except for small ac later for the elimination of switching ripple, and can be made compact and highly reliable compare with the do link inverter system. Matrix converter, however, directly connected the input and the output terminals by bidirectional static switch. As a result if the input voltage are asymmetrical, and contain harmonics, the influence of the distortions directly appear on the output terminal. This problem is a major obstacle to the matrix converter. A new control method using average comparison strategy have been proposed in this paper. This control method realizes sinusoidal input and output current unity input displacement factor regardless of load power factor. Moreover, compensation of the asymmetrical and/or harmonic containing input voltage is automatically realized, and calculation time of control function is reduced.

Determination of Strain Energy Function of Rubber Materials Considering Stress Softening Behavior (응력연화거동을 고려한 고무 재료의 변형률 에너지 함수 결정)

  • Kim, W.S.;Hong, S.I.
    • Elastomers and Composites
    • /
    • v.42 no.3
    • /
    • pp.168-176
    • /
    • 2007
  • When the rubber vulcanizates reinforced with carbon black or silica are subjected to cyclic loading from its virgin state, the stress required on reloading is less than that on the initial loading. This stress softening phenomenon is referred to as the Mullins effect. The strain energy function of rubber vulcanizates was investigated using theory of pseudo-elasticity incorporated damage parameter that Ogden and Roxburgh have proposed to describe the damage-induced stress softening effect in rubber-like solids. The quasi-static cyclic loading test was performed using the NR-SBR vulcanizates reinforced with carbon black, and then the effect of a damage parameter to stress-strain curve in reloading and subsequent reloading paths was studied. The strain energy function of the rubber vulcanizates with a different filler content was also evaluated.

Speed Control of Darrieus Wind Turbine for Load-variation (다리우스 풍력터빈의 부하변동에 따른 속도제어)

  • 오철수
    • Journal of Energy Engineering
    • /
    • v.4 no.3
    • /
    • pp.402-406
    • /
    • 1995
  • 다리우스 풍력터빈의 속도설정을 터빈이 만드는 토크와 발전기가 요구하는 토크의 \평형을 통해 찾아 낼 수 있음을 검토하였다. 풍속에 따른 속도-토크곡선에서 일정충력곡선이 만나는 점이 터빈의 동작점으로 되며 이는 안정 및 불안정이 될 수도 있다. 풍속과 출력이 각각 변할 때 이 동작점이 어떻게 이동되는가 하는 점을 제시하였다. 또한 터빈의 속도에 관한 제어 블록선도를 제시하여 그 출력변화에 따른 속도변화의 전달함수를 알아내고 이의 형태는 1차 시지연 함수로 유도된다.

  • PDF

Exploration of Functional Parallelism using threads (스레드를 이용한 함수 병렬성 추출)

  • 김현철;이성우;류시룡;유기영
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2000.10c
    • /
    • pp.633-635
    • /
    • 2000
  • 본 논문에서는 프로그램을 루프 구조에 근거하여 계층적으로 표현한 HTG (Hierarchical Task Graph)의 복합 노드 태스크들을 공유 메모리 다중처리기 환경에서의 효율적 수행을 위한 새로운 스케쥴링 기법을 제안한다. 단일처리기의 멀티스레드 구조를 비롯한 여러 플랫폼에 적용하기 위해 자바의 스레드를 사용하여 구현하였으며, 기존의 HTG의 함수 병렬성을 위한 비티 벡터 알고리즘과 성능을 비교 분석하였다. 실험 결과에서 보듯이, 제안된 기법이 비트 벡트 방법에 비해 수행 시간 측면에서 효율적임을 알 수 있으며 또한, 좋은 부하 균형을 유지하였다.

  • PDF

Data Distribution using Genetic Algorithm (유전자 알고리즘을 이용한 데이타 분산 기법)

  • 이순미;박혜숙
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.10b
    • /
    • pp.187-189
    • /
    • 2003
  • 분산 데이타베이스 시스템은 통신망으로 연결되어 있는 컴퓨터 노드들의 집합으로 구성되어 있으며 각 노드들은 데이타, 프로그램, 처리능력 등의 자원을 공유한다. 데이타의 분산은 접근 시간 단축, 가용성과 신뢰성, 동시성의 증가와 같은 장점이 있으나 통신 비용과 시스템 부하와 같은 성능저하 요인이 될 수도 있으므로 데이타를 최적의 노드에 분산시키는 할당 문제가 중요한 이슈이다. 본 논문에서는 시스템 운영 비용을 최소화 시키는 최적의 할당 노드를 찾기 위한 목적 함수를 기술하였으며 유전자 알고리즘을 사용하여 할당 목적 함수의 해를 구현하였다.

  • PDF

Quantification of Myocardial Blood flow using Dynamic N-13 Ammonia PET and factor Analysis (N-13 암모니아 PET 동적영상과 인자분석을 이용한 심근 혈류량 정량화)

  • Choi, Yong;Kim, Joon-Young;Im, Ki-Chun;Kim, Jong-Ho;Woo, Sang-Keun;Lee, Kyung-Han;Kim, Sang-Eun;Choe, Yearn-Seong;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.316-326
    • /
    • 1999
  • Purpose: We evaluated the feasibility of extracting pure left ventricular blood pool and myocardial time-activity curves (TACs) and of generating factor images from human dynamic N-13 ammonia PET using factor analysis. The myocardial blood flow (MBF) estimates obtained with factor analysis were compared with those obtained with the user drawn region-of-interest (ROI) method. Materials and Methods: Stress and rest N-13 ammonia cardiac PET imaging was acquired for 23 min in 5 patients with coronary artery disease using GE Advance tomograph. Factor analysis generated physiological TACs and factor images using the normalized TACs from each dixel. Four steps were involved in this algorithm: (a) data preprocessing; (b) principal component analysis; (c) oblique rotation with positivity constraints; (d) factor image computation. Area under curves and MBF estimated using the two compartment N-13 ammonia model were used to validate the accuracy of the factor analysis generated physiological TACs. The MBF estimated by factor analysis was compared to the values estimated by using the ROI method. Results: MBF values obtained by factor analysis were linearly correlated with MBF obtained by the ROI method (slope = 0.84, r = 0.91), Left ventricular blood pool TACs obtained by the two methods agreed well (Area under curve ratio: 1.02 ($0{\sim}1min$), 0.98 ($0{\sim}2min$), 0.86 ($1{\sim}2min$)). Conclusion: The results of this study demonstrates that MBF can be measured accurately and noninvasively with dynamic N-13 ammonia PET imaging and factor analysis. This method is simple and accurate, and can measure MBF without blood sampling, ROI definition or spillover correction.

  • PDF

An Analysis of Optimal Operation Strategy of ESS to Minimize Electricity Charge Using Octave (Octave를 이용한 전기 요금 최소화를 위한 ESS 운전 전략 최적화 방법에 대한 분석)

  • Gong, Eun Kyoung;Sohn, Jin-Man
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.85-92
    • /
    • 2018
  • Reductions of the electricity charge are achieved by demand management of the load. The demand management method of the load using ESS involves peak shifting, which shifts from a high demand time to low demand time. By shifting the load, the peak load can be lowered and the energy charge can be saved. Electricity charges consist of the energy charge and the basic charge per contracted capacity. The energy charge and peak load are minimized by Linear Programming (LP) and Quadratic Programming (QP), respectively. On the other hand, each optimization method has its advantages and disadvantages. First, the LP cannot separate the efficiency of the ESS. To solve these problems, the charge and discharge efficiency of the ESS was separated by Mixed Integer Linear Programming (MILP). Nevertheless, both methods have the disadvantages that they must assume the reduction ratio of peak load. Therefore, QP was used to solve this problem. The next step was to optimize the formula combination of QP and LP to minimize the electricity charge. On the other hand, these two methods have disadvantages in that the charge and discharge efficiency of the ESS cannot be separated. This paper proposes an optimization method according to the situation by analyzing quantitatively the advantages and disadvantages of each optimization method.

Field Cooling Tests of Paddy Stored in Steel Bins with a Grain Cooler (곡물냉각기를 이용한 철제 원형빈에서 벼 냉각)

  • 김의웅;김동철
    • Food Science and Preservation
    • /
    • v.11 no.2
    • /
    • pp.263-268
    • /
    • 2004
  • Two field cooling tests were conducted to evaluate the cooling characteristic of paddy with a prototype grain cooler. The first test was carried out during summer season in a steel bin with 180.3ton of paddy at Sunchon. And the second test was carried out during harvesting season in a steel bin with 272.2ton of paddy at Ulsan. At the first test, initial paddy temperature of 23.6$^{\circ}C$ was dropped to 14$^{\circ}C$, and initial moisture content of 19.9% was dropped to 19.3% after 52.5 hours of cooling. At the second test, initial paddy temperature of 16.1$^{\circ}C$ dropped to 5.5$^{\circ}C$ after 78.0 hours of cooling. And, at the first test, the average air flow rates of chilled air leaving the grain cooler and penetrating the grain layer were 77.5 ㎥/min and 42.5 ㎥/min, respectively. To prevent leakage of chilled air from plenum chamber of steel bin, which was about 45% of the average air flow rates of chilled air leaving the grain cooler, a proper method was required. The average total power consumption at the first test during summer was 22.1 ㎾ with control of fan damper. At the second test, it was 17.4 ㎾ due to controlling the capacity of compressor with unloading solenoid valve and changing the flow rates of hot refrigerant gas flowing into evaporator and reheater from compressor, resulting in 27% reduction of energy consumption.

Practical Study on Adjustment of Load Correlation Equations of Pole Transformer (주상변압기 부하 상관식 조정에 관한 실증적 연구)

  • 박창호;김두봉;김기현;배주천;윤상윤;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.102-108
    • /
    • 2000
  • This paper presents a result of practical study about the adjustment of load correlation equation for the load management of pole transformer. For adjusting the load correlation equation, we analyze the correlative relation between working electric energy[kWh] and peak load[A]. To enhance the accuracy of correlation equation, we classify the 12 representative area patterns. And then, we select the 24 sample pole transformer for each area pattern. For the reliability of the data using the load correlation equation, load management equipment is utilized for each sample pole transformer. Through the on-line data acquisition, we construct the database. For adjusting the load correlation equation, we consider the two points. One is the goodness of fitness for load correlation equation and the other is prevention of pole transformer damage due to the overload. Finally, we propose the correlation equation using the linear and quadratic equation all at once. Through the case studies, we verify that the proposed load correlation equation is reduced the error ratio than conventional correlation equation.

  • PDF

A History-based Scheduler for Dynamic Load Balancing on Distributed VOD Server Environments (분산 VOD 서버 환경에서 히스토리 기반의 동적 부하분산 스케줄러)

  • Moon, Jongbae
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.04a
    • /
    • pp.210-213
    • /
    • 2010
  • 최근 사용자의 멀티미디어에 대한 요구의 증가가 VOD (Video-on-Demand) 서비스를 발전시키게 되었다. VOD는 엔터테인먼트나 원격 교육, 광고 및 정보 등 많은 분야에서 사용되고 있다. 이러한 VOD 서비스는 많은 디스크 I/O와 네트워크 I/O를 요구하며 기존 웹 서버 시스템과 비교했을 때 오랜 시간동안 서비스를 해야 하는 특징을 가지고 있다. 또한 VOD 서비스는 많은 네트워크와 디스크의 대역폭을 요구하며, 서비스의 QoS에 민감해서 사용자 응답시간이 길어지면 사용자 요청의 취소율이 높아지게 된다. 따라서 불만족스러운 서비스의 증가로 네트워크 부하만 증가하게 된다. 이러한 기존 웹 서버 환경과는 다른 부하의 패턴이 있는 VOD 서비스 환경에서는 부하를 균형적으로 분배하여 서비스의 QoS를 높이는 것이 매우 중요하다. 본 논문에서는 분산 VOD 시스템 환경에서 부하를 효율적으로 분산하기 위해 계층형 분산 VOD 시스템 모델과 사용자 요청 패턴의 히스토리와 유전 알고리즘을 기반으로 한 스케줄러를 제안한다. 본 논문에서 제안한 계층형 분산 VOD 시스템 모델은 서버들을 지역적으로 분산하고 제어 서버를 지역마다 설치하여 지역에 있는 VOD 서버들을 관리하도록 구성한다. 사용자 요청을 지역 서버군 내에서 분산시키기 위해서 히스토리를 기반으로 한 유전 알고리즘을 사용한다. 이러한 히스토리 정보를 기반으로 유전 알고리즘의 적합도 함수에 적용하여 VOD 시스템을 위한 유전 알고리즘과 유전 연산을 구현한다. 본 논문에서 제안한 부하 분산 알고리즘은 VOD 서비스 환경에서 사용자 요구에 대한 부하를 보다 정확하게 예측하여 부하를 분산할 수 있다. 본 논문에서 제안한 계층형 분산 VOD 시스템의 부하 분산 알고리즘의 성능을 테스트하기 위해 OPNET 기반 시뮬레이터를 구현한다. 라운드로빈(round-robin) 방식과 랜덤(random) 방식과의 비교 실험을 통해 본 논문에서 제안한 부하 분산 알고리즘의 성능을 평가한다. 비교 실험을 통해 본 논문에서 제안한 알고리즘이 보다 안정적인 QoS를 제공하는 것을 보여준다.