• Title/Summary/Keyword: 부피측정

Search Result 1,050, Processing Time 0.03 seconds

Volume Measurement Method for Object on Pixel Area Basis through Depth Image (깊이 영상을 통한 화소 단위 물체 부피 측정 방법)

  • Ji-hwan Kim;Soon-kak Kwon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.29 no.1
    • /
    • pp.125-133
    • /
    • 2024
  • In this paper, we propose a volume measurement method for an object based on depth image. The object volume is measured by calculating the object height and width in actual units through the depth image. The object area is detected through differences between the captured and background depth images. The volume of the 2×2 pixel area, formed by four adjacent pixels using the depth information associated with each pixel, is measured. The object volume is measured as the sum of the volumes for whole 2×2 areas in the object area. In simulation results, the average measurement error for the object volume is 2.1% when the distance from the camera is 60cm.

Effects of Various Intracranial Volume Measurements on Hippocampal Volumetry and Modulated Voxel-based Morphometry (두개강의 용적측정법이 해마의 용적측정술과 화소기반 형태계측술에 미치는 영향)

  • Tae, Woo-Suk;Kim, Sam-Soo;Lee, Kang-Uk;Nam, Eui-Cheol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.63-73
    • /
    • 2009
  • Purpose : To investigate the effects of various intracranial volume (ICV) measurement methods on the sensitivity of hippocampal volumetry and modulated voxel-based morphometry (mVBM) in female patients with major depressive disorder (MDD). Materials and Methods : T1 magnetic resonance imaging (MRI) data for 41 female subjects (21 MDD patients, 20 normal subjects) were analyzed. Hippocampal volumes were measured manually, and ICV was measured manually and automatically using the FreeSurfer package. Gray and white matter volumes were measured separately. Results : Manual ICV normalization provided the greatest sensitivity in hippocampal volumetry and mVBM, followed by FreeSurfer ICV, GWMV, and GMV. Manual and FreeSurfer ICVs were similar in normal subjects (p = 0.696), but distinct in MDD patients (p = 0.000002). Manual ICV-corrected total gray matter volume (p = 0.0015) and Manual ICV-corrected bilateral hippocampal volumes (right, p = 0.014; left, p = 0.004) were decreased significantly in MDD patients, but the differences of hippocampal volumes corrected by FreeSurfer ICV, GWMV, or GMV were not significant between two groups (p > 0.05). Only manual ICV-corrected mVBM analysis was significant after correction for multiple comparisons. Conclusion : The method of ICV measurement greatly affects the sensitivity of hippocampal volumetry and mVBM. Manual ICV normalization showed the ability to detect differences between women with and without MDD for both methods.

  • PDF

New Method of Volume Measurement for Reference Weights of a Pressure Balance Using a Gas Pycnometer (기체용적계를 이용한 분동식 압력계용 기준분동의 새로운 부피측정 방법)

  • Lee, Yong Jae;Lee, Woo Gab;Mohammed, Mohammed Abdurahman;Park, Yon-Kyu;Oh, Chae Yoon
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.5
    • /
    • pp.231-237
    • /
    • 2013
  • New method of volume measurement for reference weights of a pressure balance using a gas pycnometer is proposed. The result of volume measurement of proposed method shows the uncertainties of approximately 0.2% at the level of confidence of 95% for reference weights in the ranges of 1 kg, 2 kg, and 5 kg. This measuring system consists of a sample chamber, an expansion chamber, a precision pressure gage, a precison thermometer, a vacuum pump, and helium as a medium gas. The measurement principle of this proposed method is based on Boyle's law. This method will contribute a reliability of the volume measurements of reference weights for a pressure balance to the national measurement standard.

Measurement of Photospetroscpopies by Anesthetics in Purple Membrane and Red Membrane (Purple Membrane과 Red Membrane에서 마취제에 의한 분광학적 측정)

  • Kim, Ki-Jun;Jeong, Hyeon-ghak;Kim, Juhan;Song, Hui-jun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.2
    • /
    • pp.472-477
    • /
    • 2018
  • The excess molar volumes of a general anesthetics on Purple membrane and Red membrane separated by extraction in Halobacteriun Halobium and in suspensions of vesicle have been determined at $25^{\circ}C$, it was used a excess volume dilatometer. The anesthesia characteristics of general anesthetics, Propofol was fined by our study to correlate with excess molar volume. Excess volume changes of the vesicle measured by excess volume dilatometer, which is an important amino acid and lipid in the purple membrane and red membrane by means of specific weight in Halobacteriun Halobium, were studied by absorption intensity at 280 nm and 330 nm. The particle size analysis and relative turbidity of Purple membrane and Red membrane by means of Propofol were measured for mechanical properties. In the samples where Propofol is incoporated in vesicle, especially, the excess molar volume of PM + RM + Propofol is the greatest than the excess molar volumes of PM, and RM.

MR 뇌 영상으로부터 20대 한국인의 소뇌 부피 측정

  • 김태영;이법이;정순철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.295-295
    • /
    • 2004
  • 본 연구에서는 한국인 20대 남자 50명(23$\pm$2세)과 여자 50명(20$\pm$1세)의 MR 뇌 영상을 KAIST 뇌과학 연구센터에 있는 37 MRI 기기로 획득하였고 Brain Voyager(B/V)를 이용하여 소뇌의 부피를 측정하고자 한다. 남자와 여자의 뇌의 구조가 부분적으로 차이가 있다는 것은 이미 밝혀진 사실이다 남자의 전체적인 brain volume이 약 10% 크다는 사실도 잘 알려져 있다. 그러므로 본 연구에서도 성별에 따라 소뇌의 부피의 차이가 있는지도 검증하고자 한다.(중략)

  • PDF

Evaluation on Protrusion of the Imaginary Prostate Volume Using Three-Dimensional Volume Rendering (3차원 볼륨 렌더링을 이용한 가상 돌출형 전립선 부피 평가)

  • Seoung, Youl-Hun;Joo, Yong-Hyun;Rhim, Jae-Dong;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.208-215
    • /
    • 2009
  • This study is to compare the accuracy of evaluation regarding the volume of the prostate, which three-dimensional volume rendering was produced the shape of protrusion, by measuring two kinds of craniocaudal length from the top of the protrusion and from the exclusion of the protrusion as the starting points. For the imaginary protrusion prostate models, total of 10 models were roughly made by using devils-tongue jelly and changing each of the 10 ml of capacity from 10 ml to 100 ml. For the protrusion prostate models aimed at estimating the real volume, through 64 cannel computed tomography (CT) and 3.0 tesla magnetic resonance image (MRI) were conducted by planimetry technique from three-dimensional volume rendering. And then we performed to evaluate on significance of these volumes by wilcoxon signed rank test. Also the obtained volumes data by ellipsoid volume formula were measured the volume of protrusion prostate models two times with each method using the two kinds of craniocaudal length from top of the protrusion and from exclusion of the protrusion as the starting points. Finally, the significance of differences using wilcoxon signed rank test was evaluated between the real volume by planimetry technique and the measured volume by ellipsoid volume formula from three-dimensional volume rendering. The average of the protrusion length on the models was $0.90{\pm}0.18\;mm$ in CT and was $0.75{\pm}0.11\;mm$ in MRI. There were not statistically significant difference between MRI and CT from the volume of protrusion prostate models (p=0.414). In MRI (p=0.139) and CT (p=0.057), there were not statistically significant difference between the real volume by planimetry technique and the measured volume by ellipsoid volume from exclusion of the protrusion as the starting points. While, there were statistically significant difference between the real volume by planimetry technique and the measured volume by ellipsoid volume from top of the protrusion as the starting points in MRI (p=0.005) and CT (p=0.005). For the accurate measurement of the protrusion prostate models, the craniocaudal length of the prostate should be measured from the exclusion of the protrusion as the starting points.

  • PDF

College Students' Misconception about the Volume Change of Solution during Acid/Base Titration: Partial Molar Volume of Salt (산·염기 적정에서 용액의 부피 변화에 대한 대학생들의 오개념 연구)

  • Jang, Nak Han
    • Journal of Science Education
    • /
    • v.33 no.2
    • /
    • pp.317-320
    • /
    • 2009
  • I investigated Korean college students' conception about the volume change of solution when they detected the equivalence point during acid/base titration experiment using method of volume measurement. According to this study, most college students had a misconception that the volume increment was due to the formation of water by neutralization during acid/base titration. However, this is not enough to explain the volume change, neglecting contribution of a salt in solution. I calculated the partial molar volume of NaCl formed to explain the volume increment of solution during HCl/NaOH neutralization. Comparing the result of experiment with the calculation of partial molar volume, I elucidated that the main effect of volume increment was due to the partial molar volume of NaCl formed during HCl/NaOH neutralization. Here I propose to introduce college students to the concept of partial molar volume of the salt formed to reduce misconception about the volume change of solution during acid/base neutralization.

  • PDF

Physical property evolution along gas hydrate saturation for various grain size distribution (다양한 입도분포에서의 하이드레이트 함유량에 따른 물성 변화 양상 연구)

  • Jung, Jaewoong;Lee, Jaehyung;Lee, Joo Yong;Lee, Minhui;Lee, Donggun;Kim, Sejoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.149-149
    • /
    • 2011
  • 청정 에너지원으로 높은 잠재력을 가지고 있는 가스하이드레이트는 상업적 기술개발이 미확보된 상태임에도, 우리나라에서 부존이 직접적으로 확인되었기 때문에 에너지원으로서 그 중요성이 부각되고 있다. 현재 전세계적으로 가스하이드레이트 개발 및 생산에 관한 연구가 활발히 진행되고 있으며 이에 대한 기초자료로서 가스하이드레이트가 함유된 퇴적층의 물성자료가 필요하다. 이에 따라 본 연구에서는 입도 분포별 총 5가지의 미고결 시료를 대상으로 투과도, p파속도, 전기비저항 측정을 수행하였다. 연구에 사용된 미고결 시료는 Hama#5($774{\mu}m$), #6($485{\mu}m$), #7($258{\mu}m$), #8($106{\mu}m$) 4가지와 Hama#6과 Hama#7을 1:1($371{\mu}m$)로 혼합하여 사용하였다. 실험에 사용된 장비는 가스하이드레이트를 인공적으로 생성시키기 위해 퇴적층을 모사할 수 있는 고압셀과 자료획득장비, 유체 주입장비, 온도 유지장비이다. 또한 투과도 측정에는 차압계, 전기비저항 측정에 RLC meter, p파속도 측정에 음파 송수신장비를 사용하여 각각의 물성을 측정하였다. 실험과정을 단계별로 요약하면 먼저 시료를 고압셀에 충진한 뒤 주입된 물의 양으로부터 공극률을 측정하고, 절대 투수계수를 측정하였다. 그 후, 메탄가스를 주입하여 퇴적층 내 수포화도(water saturation)를 잔류상태(irreducible saturation)로 유지시키고 메탄가스를 추가적으로 주입하여 원하는 압력까지 가압한 뒤 온도를 $1^{\circ}C$로 낮추었다. 가스하이드레이트의 생성은 급격한 압력강하로부터 알 수 있다. 최종적으로 가스하이트레이트가 함유된 퇴적층의 상대 투수계수를 측정하기 위해 메탄가스를 주입하였고 각각의 측정장비를 통해 전기비저항 및 p파 속도를 측정하였다.$V_g$, $V_h$, $V_w$, $V_ss$는 각각 가스의 부피, 하이드레이트의 부피, 물의 부피, 모래의 부피이다. 또한 수포화도, $S_w=\frac{V_w}{V_v}$이며 하이드레이트 포화도, $S_h=\frac{V_w}{V_v}$, 가스 포화도, $S_g=\frac{V_g}{V_v}$로 정의된다. 본 실험의 결과 투과도는 가스의 부피비, $\frac{V_g}{V}=nS_g$에 민감한 반응을 보였으며, 비저항은 공극수의 부피비, $\frac{V_w}{V}=nS_w$에 민감한 반응을 보였다. 또한 p파 속도는 고체의 부피비, $\frac{V_s+V_h}{V}=n(1-S_h)$에 민감한 반응을 보였다. 이러한 실험의 결과는 가스하이드레이트 개발, 생산 연구에 있어 기초 물성자료로 활용되는데 도움을 줄 것이다.

  • PDF