• Title/Summary/Keyword: 부착미생물

Search Result 315, Processing Time 0.028 seconds

Treatment of Animal Wastewater Using Woodchip Trickling Filter System and Physical and Microbial Characteristics of Wood Chip Media (목편살수여상조를 이용한 축산뇨오수 처리와 목편여재의 물성 및 부착미생물 특성)

  • Ryoo, Jong-Won
    • Journal of Animal Environmental Science
    • /
    • v.17 no.2
    • /
    • pp.71-80
    • /
    • 2011
  • Trickling filter has been extensively studied for the domestic wastewater treatment especially for the small scale plants in rural area. The purpose of this research is to survey the physical and microbial characteristics of wood chip media and the removal efficiency of animal wastewater using wood chip trickling filter system. The trickling filtration system comprises a filtration bed packed with wood chip media having a particle dia. of 5~7cm. The method comprises natural air from the bottom of the bed. The system also comprises a control mechanism including a time a constant discharge pump for controlling supply of the wastewater into the bed. The following conclusions were obtained from the results of this research. 1. The specific surface area of wood chip was 0.4123 $m^2$/g, pore volume was 0.0947 $cm^3$/g, density was 0.49 g/$cm^3$. It has forms of parallelogram and oblong which have numerous small pore space. This wood chip has been good condition for microorganism's habitat, having very larger specific surface area by complex the three dimension structure of cellulose at wood's major ingredients. 2. The total counts of in attached aerobic microbes were ranged from $10^6$ to $10^8$ CFU/g, and anaerobes microbial numbers were from $10^4$ to $10^7$. The aerobic microbial numbers appeared to be much more than those of anaerobic microbial numbers. 3. The average efficiency of $BOD_5$ and CODcr were 74.5% and 51.5%, respectively. The removal efficiency of T-N and T-P were 61.4%, 56.2%, respectively. But SS removal levels remain 19.3%.

The test-bed construction and water purification assessment of the eco-convergence type aerated string contacted oxidation system (생태융합형 접촉산화수로 Test-Bed 구축 및 정화효율 평가)

  • Choi, Sunhwa;Lee, Seung-Heon;Jang, Kyusang;Kim, Heungseop
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.592-592
    • /
    • 2016
  • 국내에는 17,500여개의 농업용 저수지가 전국적으로 분포하고 있다. 국내 농업용 저수지는 대부분이 소규모이며, 연중 수량 변동이 심하고, 유역배율이 작아 태생적으로 수질오염에 취약한 구조로 되어 있다. 특히 농업용 저수지는 도시 근교나 농촌지역에 많이 위치하고 있어 유역 내 축산 농가나 미처리 생활하수에서 유래된 유기물 및 영양염류 유입에 의한 수질오염도가 높다. 저수지에 고농도로 유입되는 유기물, TN, TP를 처리하기 위하여 농어촌연구원과 수생태복원(주)에서는 공동으로 친환경 수처리시설인 생태융합형 접촉산화시스템을 개발하였다. 생태융합 접촉산화수로는 상부 식생과 수로 내의 섬유상 끈상 미생물 접촉재를 이용하여 오염수가 수로를 흐르면서 침전, 여과, 흡착, 산화, 흡수 등 물리학적, 화학적, 생물학적 원리를 이용하여 고농도의 유기물과 질소, 인을 제거하는 물리적, 생물학적 공정을 융복합 기술이다. 본 연구에서는 경기도 시흥시에 소재하고 있는 M 저수지에 현장 Test-bed를 구축하여 수질정화효율을 평가하였다. M 저수지는 유효저수지량이 약 23만톤에 해당하는 소규모 저수지로, 1941년도 준공된 아주 노후화된 저수지로 평균 수심이 2m 이하이고 연중 수질오염도가 높은 저수지이다. 매화저수지 수변에 설치된 생태융합형 접촉산화수로의 전체규모는 길이 8.6m, 폭 2m, 수심 2m에 해당하며, 끈상 미생물 메디아조 3개($2{\times}2{\times}6m^3$), 침전조 1개($2{\times}2{\times}2m^3$)로 구성되어 있다. 기타 부대 장치로는 끈상 메디아조에 산소공급을 위한 Air-mist(마이크로 버블 발생장치), 자동운전계기판, 유입펌프 등이 있다. 생태융합형 접촉산화수로의 처리 공정은 유입수${\rightarrow}$에어미스트${\rightarrow}$고속복합응집장치${\rightarrow}$융복합 산화조(3조)${\rightarrow}$침전조${\rightarrow}$방류로 구성되어 있다. 테스트 베드는 2015년 8월 말경에 구축 완료하였으며, 끈상 미생물 메디아조의 수질정화효율을 평가하기 위하여 9월부터 11월까지 총 7회 걸쳐 유입수와 유출수를 각각 조사하였다. 현장 측정항목인 수온, pH, EC, DO 등은 유입수 및 유출수간 큰 차이가 없었고, COD, SS, Chl-a, TP 등은 수처리시스템 초기 가동시에는 메디아에 미생물 부착율 저조로 유입수 및 유출수 수질농도에 큰 차이가 없었으나, 운영시간의 경과와 함께 메디아의 미생물 충진율이 높아짐에 따라 처리효율이 최대 SS 69.6%, Chl-a 89.3%, TP 89%까지 도달하는 것으로 나타났다. 생태융합 접촉산화수로는 부지 집약적인 컴팩트한 수처리 시설로서 현재 널리 이용되고 있는 인공습지를 대체할 수 있는 경제적인 시설로 판단된다.

  • PDF

Organic Carbon, Nitrogen and Phosphorus Removal in High-concentration Organic Wastewater using the Media attached Microorganism (미생물 접촉재를 이용한 고농도 유기폐수의 유기물 및 질소 ${\cdot}$ 인 제거)

  • Kim, Pan-Soo;Son, Han-Hyung;Lee, Sang-Ho
    • Proceedings of the KAIS Fall Conference
    • /
    • 2007.05a
    • /
    • pp.299-302
    • /
    • 2007
  • 본 연구는 하 ${\cdot}$ 폐수 중의 유기물뿐만 아니라 질소, 인을 생물학적으로 제거하는 실험을 수행하였다. 공정 내 미생물의 유실을 방지하고 미생물이 고농도 상태로 유지 가능한 부착성장의 한 공법인 RBC에 끈상 나선형 미생물 접촉재를 설치한 반웅기를 이용하였다. 원수는 Glucose 1,800 mg/L, $NH_{4}Cl$ 500 mg/L, $KH_{2}PO_{4}$ 5mg/L를 혼합한 인공폐수를 제조하여 공정에 주입하였고, 그 결과 각각 미생물이 폐수에 적응하는 단계인 Period 1에서는 각 수질 분석 항목의 농도가 점차적으로 감소하는 경향을 보였으며, 정상상태라고 판단한 Period 2에서는 최종적으로 유입수에 대한 유출수의 제거율은 각각 $TCOD_{Cr}$ 94%, BOD 87%, T-N 85%, T-P 89%의 결과를 나타내었다.

  • PDF

Microbial Contamination in a Facility for Processing of Fresh-Cut Leafy Vegetables (신선편이 채소류 가공작업장 내 시설 및 제품의 미생물 오염 실태)

  • Kim, Byeong-Sam;Lee, Hye-Ok;Kim, Ji-Young;Yoon, Doo-Hyun;Cha, Hwan-Soo;Kwon, Ki-Hyun
    • Food Science and Preservation
    • /
    • v.16 no.4
    • /
    • pp.573-578
    • /
    • 2009
  • Microbial contamination levels in a fresh-cut leafy vegetable processing plant were evaluated. Total plate counts of samples collected from the walls, equipment, and raw materials ranged from $10^1{\sim}10^2$ CFU/100 $cm^2$, $10^0{\sim}10^4$ CFU/100 $cm^2$, and $10^4{\sim}10^6$ CFU/g, respectively. No coliforms were detected on walls; however, equipment and raw materials contained coliforms in concentrations ranging from ND (not detected)to $10^2$ CFU/100 $cm^2$ and $10^4{\sim}10^5$ CFU/g, respectively. Additionally, total plate counts for falling and floating bacteria in the processing plant were $10^0{\sim}10^1$ CFU/plate and $10^1{\sim}10^3$ $CFU/m^3$, respectively. Pathogenic microorganisms such as Escherichia coli, Salmonella spp, Staphylococcus aureus, or Listeria monocytogenes were not detected on walls, equipment, or raw materials. Overall, the results of this study indicate that hygiene control in the fresh-cut processing plant should be improved.

EFFECTS OF POLYPHOSPHATE MIXED IN ACRYLIC RESIN ON THE ATTACHMENT AND GROWTH OF ORAL BACTERIA (Acrylic Resin에 혼합된 Polyphosphate가 미생물의 부착 및 성장에 미치는 영향)

  • Hong, Sun-Hee;Choi, Yeong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.69-79
    • /
    • 2003
  • The purpose of this present study was to develop a new way of self-curing acrylic resin, using commercially available polyphosphate, Calgon, which is known to be antimicrobial and safe. For the study, polyphosphate(polyP) was blended with acrylic powder and devided into four groups as follows: no polyP(control), 1% polyP, 2% polyP, and 3% polyP. For the experiment, Streptococcus mutans GS5, Streptococcus sobrinus 6715, Streptococcus gordonii G9B and Challis, Porphyromonas gingivalis 2561, and Candida albicans ATCC 90027 were used. Resin specimens in each group were tested in vitro for the purpose of investigating the effect of polyP on the microbial attachment, growth and hydrophobicity of the resin surface. The results were as follows. 1. PolyP added to the acrylic resin decreased attachment of S. mutans GS5, S. sobrinus 6715, S. gordonii G9B. The greater binding inhibition was found in acrylic resin polymerized with polyP at higher concentrations. 2. The addition of polyP to acrylic resin failed to significantly affect the growth of the tested microorganisms. 3. The addition of polyP to acrylic resin seemed to reduce hydrophobicity of the acrylic resin. PolyP in acrylic resin does not seem to exert a direct antibacterial activity, but rather inhibit attachment of oral bacteria, especially mutans streptococci to saliva-coated acrylic resin. The acrylic resin reduces attachment of streptococci may be due to the decreased hydrophobicity caused by polyP added to the resin. PolyP may be included to acrylic resin to inhibit dental caries which often occurs when removable acrylic resin appliance is placed.

  • PDF

Treatment of dyeing wastewater using Moving Bed Bioractor (부유메디아 생물막 공정을 이용한 염색폐수처리)

  • Shin, Dong-Hoon;Lee, Sang-Hun;Ryu, Seung-Han;Park, Jun-Hyung;Jo, Seog-Jin
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2011.03a
    • /
    • pp.110-110
    • /
    • 2011
  • 염색공업 폐수는 그 성분이 일반적으로 매우 복잡하며, 작업공정의 가동 사항에 따라 수질 변동이 큰것이 특징으로, 각 공정에서 배출되는 염료, 보조화학물질, PVA(Polyvinyl alchol), 전분, wax 등이 포함되어 있으며 pH가 높고, 색도로 인해 하천에 방류될 경우 확산성이 높아 미생물에 의한 자정작용을 방해하여 하천의 수중생태계를 파괴할 우려가 있다. 이러한 염색산업에서 발생하는 폐수는 일반적으로 응집침전, 부상분리법 등의 전처리한 후 활성오니공정으로 처리하는 방법이 널리 이용되고 있으나, 이들 처리공정으로는 폐수 속에 포함되어 있는 다양한화학적 구조의 색소성분 및 유해물질을 완벽하게 제거하는 것이 어려운 실정이다. 유기물 함량이 높은 염색폐수를 처리하기 위해 제안된 기술로는 산소활성슬러지법, 유동상 및 고정상 생물막법, 포괄고정화법 등이 있다. 이러한 기술들중 기존의 처리공정을 증축없이도 처리효율을 높일 수 있는 방법으로 담체를 이용한 부유메디아 생물막공정(Moving-Bed BioReactor, MBBR)이 있다. 이공정은 미생물이 부착, 성장할 수 있는 공극율과 비표면적이 큰 담체를 이용하므로 반응조내의 부유 미생물 뿐만 아니라 담체에 고농도로 부착된 부착 미생물에 의해서도 유기물을 제거하기 때문에 다른 공정들에 비해 처리효율이 뛰어나고 기존의 활성슬러지 공정에 비해 갑작스러운 부하변동 및 유독성 폐수유입에 대해서도 안정적으로 운전이 가능한 장점이 있다. 본연구에서는 부유메디아 생물반응기(Moving-Bed BioReactor, MBBR)을 이용하여 염색폐수내 $COD_{Mn}$, 색도 및 난분해성 물질인 PVA 저감에 대한 Lab-scale test 수행하였다. 실험에 사용된 염색폐수의 수질은 평균 pH 13, $COD_{Mn}$ 900 mg/L, SS 135 mg/L, 색도 1,134 [C.U.], PVA 593 mg/L였으며, 2L의 반응기를 사용하여 회분식 실험을 수행였다. 본 실험에서는 호기성 미생물에 의한 염색폐수의 생분해가 유지되는데 필요한 최적의 용존산소 농도와 이에 필요한 공기 폭기량을 결정하기 위하여 i) DO uptake rate측정과 ii) 담체의 충진율, iii) COD/N ratio, iv) Air 유량, v) 담체내 흡착제의 종류, vi) $Ca^{2+}$ 첨가가 염색폐수의 생분해에 미치는 영향을 살펴보았다. 운전시간을 7일로 하여 COD, 색도, PVA 등을 측정한 결과 담체를 첨가한 경우가 담체를 첨가하지 않은 경우 보다 제거효율이 뛰어났다. 특히 충진율 30%(C/N 3)의 경우에서 COD, 색도, PVA의 제거율이 각각 평균 65%, 70%, 60%로 가장 높은 제거효율을 나타내었다.

  • PDF

Adhesion Ability and Inhibition of Enterohemorrhagic E. coli O157:H7 Adhesion to Intestinal Epithelial Cells in Lactobacillus acidophilus (Lactobacillus acidophilus의 장 상피세포에 대한 부착능력 및 장 출혈성 대장균의 부착 억제 능력)

  • 김영훈;박순옥;한경식;오세종;유승권;김세헌
    • Food Science of Animal Resources
    • /
    • v.24 no.1
    • /
    • pp.86-91
    • /
    • 2004
  • The ability of probiotics containing Lactobacillus acidophilus to adhere to the intestinal epithelium may play an important role in colonization of the gastrointestinal tract and preventing enteric pathogen such as enterohemorrhagic E. coli(EHEC O157:H7. In the study, we investigated the adhesion to human intestinal epithelial cells(HT-29) of strains of L. acidophilus(3 from human, 2 from pig, and 1 from calf). All of the tested strains of L. acidophilus were highly observed adhesion ability(from 10$\^$6/ to 10$\^$7/ cfu/mL), compared to L. rhamnosus GG as control. Also, adhered strains of L. acidophilus were significantly preserved in serial wash-out steps. However, no correlation could be observed between cell surface hydrophobicity and adhesion abilities of the tested strains of L. acidophilus. Inhibition of adhesion of EHEC O157:H7 was also examined, a 2 log cycle reduction was observed by all of the tested strains of L. acidophilus. These results suggest that the strains of L. acidophilus with high adhesion ability are resistant to wash-out and adhesion ability inhibition by selected strains of L. acidophilus helps to prevent adhesion of EHEC O157:H7 to intestinal epithelial cells.

Surface Roughness and Cariogenic Microbial Adhesion after Polishing of Smart Chromatic Technology-based Composite Resin (Smart Chromatic Technology 기반 복합 레진의 폴리싱 이후 표면 거칠기 및 우식원성 미생물 부착 )

  • Haesong Kim;Juhyun Lee;Haeni Kim;Howon Park
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.1
    • /
    • pp.65-74
    • /
    • 2023
  • This study compared the surface roughness and microbial adhesion characteristics of Omnichroma, a novel composite resin developed using "smart chromatic technology", with those of two other conventional composite resins with different filler compositions. A total of 144 specimens were fabricated using 3 types of composite resins: Omnichroma (nano-spherical), Filtek Z350XT (nanofill), and Tetric N-Ceram (nanohybrid) and, divided into 3 groups of 48. Finishing was performed using tungsten carbide burs. Specimens were then divided into 3 subgroups using different polishing methods: Control, SofLex, and PoGo. Surface roughness was analyzed quantitatively and qualitatively using an atomic force microscope and a scanning electron microscope. Microbial adhesion was assessed by culturing Streptococcus mutans on the specimens for 24 hours and then measuring colony-forming units attached to the upper surface. The surface roughness (Ra) of Omnichroma was 0.123 ㎛ after finishing, and it exhibited a smooth surface compared to the other resins. However, after polishing, there were no significant differences in the surface roughness between the three composite groups, regardless of the polishing methods. The surfaces of the Control subgroups were significantly rougher than those of the SofLex subgroups in all 3 composite groups. However, except for Tetric N-Ceram, there were no significant differences between the Control and PoGo subgroups in the other composite groups. Microbial adhesion assessment showed no significant differences between any of the 3 composite resin subgroups; however, Omnichroma exhibited higher microbial adhesion than the other two composites. No significant correlation was observed between surface roughness and microbial adhesion.

Microbial Contamination in a Fresh-Cut Onion Processing Facility (신선편이 양파 가공작업장 내의 시설 및 공정별 미생물 오염 실태)

  • Lee, Hye-Ok;Kim, Ji-Young;Yoon, Doo-Hyun;Cha, Hwan-Soo;Kim, Gun-Hee;Kim, Byeong-Sam
    • Food Science and Preservation
    • /
    • v.16 no.4
    • /
    • pp.567-572
    • /
    • 2009
  • We evaluated the microbiological quality of a facility in which freshly cut onions were prepared. The total plate counts on walls, equipment, and raw materials were ND (not detected) to $10^1$ CFU/100 $cm^2$, $10^0{\sim}10^3$ CFU/100 $cm^2$, and $10^3{\sim}10^4$ CFU/g, respectively. No coliforms were detected on walls however, coliforms were detected at concentrations of ND to $10^3$ CFU/100 $cm^2$ and $10^3{\sim}10^4$ CFU/g on equipment and raw materials, respectively. The total plate counts for falling and floating bacteria in the processing plant were ND to $10^0$CFU/plate and $10^1{\sim}10^2$ $CFU/m^3$, respectively. Pathogenic microorganisms such as Escherichia coli, Salmonella spp, Staphylococcus aureus, and Listeria monocytogenes were not detected on walls, equipment, or raw materials. Overall, the results of the study indicate that hygiene control at the fresh-cut processing plant should be improved.