• 제목/요약/키워드: 부착모르타르

검색결과 113건 처리시간 0.026초

타일 뒷발 높이에 따른 부착강도 실험 (Bond Strength Test According to height of foot of Tile)

  • 김범수;서현재;최은규;이정훈;송제영;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.283-284
    • /
    • 2018
  • The rear side surface of tiles act have protrusions that helps secure the adhesion between the tile and the mortar for tile setting. Conventional height of the rear side usually ranges between 1 to 1.5 mm, and the molding method is classified in between press type and compression type during the manufacturing process, with most tiles being produced by the former method. In sites where adhesion failures were observed, tiles were taken to examine the cause of defect. It was determined that height was irregular at the rear side surface. Based on these findings, an experiment was conducted to determine the correlation between the rear surface and the bonding strength of tiles.

  • PDF

마그네슘 인산칼륨 모르타르의 초기재령 부착성능에 관한 연구 (A Study on Early-Age bond strength of Magnesium Potassium Phosphate Mortar)

  • 강혜주;이영원;김재환;강석표
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.98-99
    • /
    • 2015
  • In the study, based on analysing bond strength of MPC and existing rapid harding grout according to shape of cross section, early ages shape of cross section is investigated about effect on bond strength to use MPC as an emergency repair material for road defects such as the form of a pot-hole. The result, MPC is about 10% higher than the shear bond strength rapid harding grout, about 20% higher bending bond strength.

  • PDF

콘크리트 혼화재료 사용에 따른 타일 부착안정성 실험적 연구 (Tile Adhesion Strength Change Testing based on Different Concrete Additive Agents)

  • 김범수;서현재;최은규;이정훈;송제영;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.165-166
    • /
    • 2017
  • The purpose of this study is to investigate the effect of tile adhesion failure due to weak adhesion with concrete admixture (FA, SP) on walls. The test specimens were divided into four types : (1) OPC 100% (2) OPC 80%+FA 20% (3) OPC 80%+SP 20% (4) OPC 60%+SP 40%, each adhered on a 650 × 650mm wall with 200mm thickness capable of attaching two insulation tiles (300 × 600mm). The tests were carried out on the four types of walls by mortar bedding application method, and after 4 weeks of curing period, adhesion strength test was carried out. The adhesion strength difference was investigated between the concrete wall with added admixture (FA, SP) and general concrete wall.

  • PDF

수치해석을 이용한 시공방법에 따른 판넬식 옹벽의 거동 분석에 관한 연구 (Numerical Approach to Evaluate the Behavior of Concrete Panel Considering Construction Method)

  • 강준희;반호기
    • 한국지반환경공학회 논문집
    • /
    • 제23권12호
    • /
    • pp.17-23
    • /
    • 2022
  • 본 논문은 Top-down 방식과 Bottom-up 방식으로 시공된 프리캐스트 판넬식 옹벽의 안전율 변화를 PLAXIS 2D 소프트웨어를 사용하여 수치해석하였다. 수치해석 조건은 시공방식, 네일 및 판넬의 고정방법, 뒤채움재 다짐상태, 강우조건 등이 있다. Top-down 방식과 Bottom-up 방식의 차이점은 뒤채움재의 유무와 지반굴착의 방식으로, Top-down 방식은 지반을 수직으로 굴착한 뒤 시공하나 Bottom-up 방식은 지반을 경사를 주어 굴착한 뒤 모르타르 및 뒤채움재를 이용하여 판넬을 부착한다. 수치해석 결과 Top-down 방식은 Bottom-up 방식과 비교하였을 때, 우기를 제외한 모든 경우에 더 높은 안전률을 확보하였다. Top-down 방식의 우기 시 안전율 저하는 Top-down 방식으로 시공 시 프리캐스트 판넬을 부착하기 위해 사용한 모르타르가 주된 원인이 된 것으로 판단하였다.

나일론 섬유를 적용한 순환 굵은골재 콘크리트의 성능 평가 (Performance of Recycled Coarse Aggregate Concrete with Nylon Fiber)

  • 이승태
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권2호
    • /
    • pp.28-36
    • /
    • 2019
  • 순환골재는 다량의 부착모르타르를 포함하고 있어 콘크리트의 강도감소, 내구성 저하, 균열발생의 원인이 되기도 한다. 본 연구에서는 보통포틀랜드시멘트(OPC)에 고로슬래그미분말(GGBFS)을 0 및 50% 대체한 순환 굵은골재 콘크리트의 역학적 특성 및 내구성에 대한 나일론섬유의 영향에 대하여 실험적으로 고찰하였다. 섬유보강 순환골재 콘크리트를 제조하기 위하여 섬유길이가 상이한 두 종류 나일론섬유를 0 및 $0.6kg/m^3$ 두 단계로 혼입하여 소정의 재령동안 수중양생하였다. 제조된 콘크리트의 압축 및 쪼갬 인장강도, 투수공극량 및 총통과전하량을 측정하여 섬유보강 부순골재 콘크리트의 성능과 비교, 고찰하였다. 또, 재령 28일 콘크리트를 대상으로 SEM 기법을 이용하여 미세조직구조를 관찰하였다. 실험결과에 따르면, 순환골재 콘크리트는 부순골재 콘크리트에 비하여 역학적 성능 및 내구성이 떨어지는 것을 확인하였으나, 나일론섬유를 혼입할 경우, 나일론 섬유의 가교작용으로 인하여 콘크리트의 성능을 개선시키는 것으로 나타났다. 특히, NF2(19 mm)를 사용한 콘크리트는 NF1(6 mm)을 사용한 콘크리트보다 역학적 성능이 다소 우수한 것으로 나타났으며, 이러한 경향은 RA 콘크리트에서 더욱 뚜렷하게 나타났다.

폴리머 혼입률에 따른 고강도 자기 수평 모르타르의 역학적 성능에 대한 실험적 연구 (An Experimental study on the Mechanical Performance of High-Strength Self-Leveling Mortar according to Polymer Mixing Ratio)

  • 정민구;조인성;김인수;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.21-22
    • /
    • 2020
  • This study is about high strength self-leveling mortar according to the mixing ratio of polymer. The self-leveling mortar currently released in Korea maintains a compressive strength of 40 Mpa as of 28 days. In addition, the level of bonding strength and flexural strength are kept the same. However, through this study, it is confirmed how the self-leveling mortar with a compressive strength of 60Mpa as of the 28th is shown according to the amount of polymer mixed. Experimental factors were configured according to the amount of polymer mixed, and the types of experiments were to confirm compressive strength, flexural strength, adhesion strength and flow. In addition, by confirming the early strength, a study was conducted to improve the quick workability compared to the self-horizontal mortar in the market.

  • PDF

습식스프레이공법으로 타설된 고인성 섬유보강 모르타르(ECC)의 역학적 특성과 보수 성능 (Mechanical and Repair Performance of Sprayed Ductile Fiber Reinforced Cememtitious Composite(ECC))

  • 김윤용
    • 콘크리트학회논문집
    • /
    • 제15권3호
    • /
    • pp.462-469
    • /
    • 2003
  • 본 논문에서는 습식스프레이 공법에 의하여 타설되는 고인성 섬유보강 모르타르(ECC)을 구조물의 보수에 적용함으로써 구조물의 내구성을 증진시키는 효과에 대하여 연구하였다. 이를 위하여 굳지않은 상태에서는 스프레이 공정에 적합한 유동특성을 갖고 있으면서, 굳은 후에는 인장변형경화거동을 나타내는 ECC를 스프레이 공법으로 타설하여 시험체를 제작하여 실험하였다. 실험 결과, 스프레이된 ECC의 역학적 특성(인장 및 휨거동)이 일반적인 타설법에 의하여 제작된 ECC와 거의 일치하는 것으로 나타났으며, 이 때에 ECC의 균열폭은 평균 30${\mu}m$로 제어되었다. 구콘크리트/ECC 합성보의 에너지 흡수능력은 구콘크리트/상용 스프레이 모르타르(PM) 합성보에 비하여 매우 우수한 것으로 나타났으며, 경계면의 부착성능도 양호한 것으로 평가되었다. ECC 고유의 균열제어능력과 더불어 보수된 부재(구콘크리트/ECC 합성보)의 탁월한 휨변형능력, 에너지 흡수능력 등은 구조물의 내구성을 증진하는데 큰 이점으로 작용하게 될 것이다.

VAE 분말수지가 고강도 폴리머 시멘트 모르타르의 강도 특성에 미치는 영향 (Effect of VAE Type Powder Polymer on Strength Properties of High Strength Polymer Cement Mortars)

  • 최중구;이건철;고경택;류금성
    • 한국건축시공학회지
    • /
    • 제15권3호
    • /
    • pp.299-306
    • /
    • 2015
  • 현재 건축분야에서는 시멘트 혼화용 폴리머를 혼입한 연구가 진행되고 있는 상황이다. 하지만 대부분의 연구는 보통강도 배합을 대상으로 연구가 진행되고 있다. 따라서 본 연구에서는 고강도 배합과 보통강도 배합에 VAE 계열의 분말형 폴리머를 혼입하여 고강도 폴리머 시멘트 모르타르의 강도 특성 및 역학적 성질을 검토하고자 하였다. 실험결과, 고강도 배합의 경우 VAE 폴리머 적용 시 폴리머 혼입양이 증가할수록 보통강도 배합에 비해 압축강도 및 휨강도가 감소하는 단점을 나타내지만, 폴리머필름 형성으로 인하여 인장강도 및 부착강도가 향상되는 장점을 나타내었다.

일인산 암모늄 수용액 분사 및 침지처리가 순환잔골재의 물성 변화에 미치는 영향 (Effect of Spray and Immersion Treatment of Mono-Ammonium Phosphate Solution on Properties of Recycled Fine Aggregate)

  • 권성준;김승호;박찬우;정철우
    • 한국건설순환자원학회논문집
    • /
    • 제12권3호
    • /
    • pp.314-321
    • /
    • 2024
  • 최근 천연골재의 고갈로 순환골재의 재활용 확대가 절실한 상황에 도달하였다. 순환골재 생산 공정에서 발생된 미세균열 및 표면에 부착된 시멘트 페이스트는 순환골재 재활용의 가장 큰 걸림돌로 작용해 왔는데, 본 연구에서는 이러한 문제를 해결하기 위해, 순환골재의 pH 저감에 효과적으로 알려진 일인산 암모늄 수용액을 활용하였다. 다양한 농도의 일인산 암모늄 수용액을 활용하여 순환잔골재의 분사 및 침지처리를 실시하였고, 처리 전 후의 물성 변화를 관찰하였으며, 최종적으로 모르타르 시험체를 제작하여 압축강도를 평가하였다. 실험 결과에 따르면, 일인산 암모늄 수용액 분사 및 침지처리를 하는 경우 순환잔골재의 흡수율은 증가하고 pH는 감소하였다. 내부의 공극 및 균열에 존재하는 수산화칼슘 및 에트링가이트는 용출되었으며, 수산화인회석의 생성으로 인해 진밀도가 상승하였다. 흡수율의 증가에도 불구하고, 모르타르 시편의 압축강도 또한 증가하였는데, 이는 분사 및 침지처리과정에서 용출된 수산화칼슘 및 에트링가이트의 제거와 순환잔골재 표면에 존재하는 미세분말의 세척으로 인한 부착강도의 증가가 주요한 원인으로 파악되었다. 일인산 암모늄 수용액의 농도가 과다한 경우(침지: 15 % 이상, 분사 20 % 이상), 모르타르의 압축강도는 저하하는 현상을 보였는데, 이는 수화생성물의 과도한 용출에 의해 증가한 흡수율과 관련된 것으로 판단된다.

표면매입보강방법으로 콘크리트내에 매입된 FRP판과 콘크리트 사이의 부착거동 (Bond Behavior between Near-Surface-Mounted Fiber Reinforced Polymer Plates and Concrete in Structural Strengthening)

  • 서수연;윤승조;권영순;최기봉
    • 콘크리트학회논문집
    • /
    • 제23권5호
    • /
    • pp.675-682
    • /
    • 2011
  • 최근 콘크리트 구조물의 보강시 사용되는 FRP(fiber reinforced polymer)를 이용한 보강에서, 철근콘크리트의 피복부분에 홈을 형성하고 이 홈내부에 FRP 바를 삽입한 후 에폭시 모르타르 등으로 보강하는 방법, 즉 표면매입보강(near-surface-mounted retrofit, NSMR)방법의 연구가 최근 활발히 진행되고 있다. 이 연구는 FRP 판을 철근콘크리트 표면에 매입보강시 FRP 판의 부착 특성을 실험적으로 연구한 논문이다. FRP 판의 매입 길이, 전단키의 유무, 보강열수 등을 변수로 부착 실험을 실시하여 파괴 기구를 관찰하고 이를 근거로 콘크리트 할렬 파괴시의 인발강도를 산정할 수 있는 강도식을 제안하였다. 실험 결과 매입 길이가 길수록 인발 내력은 증가하며 FRP 판의 열수가 증가할수록 내력이 증진되는 것으로 나타났다. 콘크리트의 할렬 파괴를 고려하여 내력을 산정한 결과 실험 결과와 좋은 대응을 보이는 것으로 나타났다.