• Title/Summary/Keyword: 부정맥 진단

Search Result 97, Processing Time 0.024 seconds

Persistent Accelerated Idioventricular Rhythm in a Shih Tzu with Central Neuropathy (중추신경 장애를 가진 시추 종의 개에서 지속적인 가속성 심실고유 율동)

  • Han, Suk-Hee;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.27 no.4
    • /
    • pp.440-444
    • /
    • 2010
  • A 7-year-old neutered male Shih Tzu dog weighing 5.2 kg was presented because of severe neurological signs (paddling, unconsciousness, blindness, seizure). ECG revealed accelerated idioventricular rhythm (AIVR) with ~140 bpm ventricular rate. Based on magnetic resonance imaging (MRI) study and cerebrospinal fluid (CSF) analysis, the neurological condition was tentatively diagnosed as disseminated granulomatous meningoencephalomyelitis (GME). The neurological signs were managed with steroids, anticonvulsive drugs, diuretics and antibiotics with 20% mannitol infusion. The rhythm disturbance (AIVR) was managed with oral medication of mexiletine. Because the heart rhythms were unstable without anti-arrhythmic therapy in spite of improvement of clinical signs after emergency treatment for neurological problems, the anti-arrhythmic therapy was maintained till the neurological signs were abolished.

Complications of transcatheter closure of atrial septal defects using the amplatzer septal occluder (심방 중격 결손의 경피적 폐쇄술 후 발생한 합병증에 관한 연구)

  • Jea, Seo Jin;Kwon, Hyo Jin;Jang, Gi Young;Lee, Jae Young;Kim, Soo Jin;Son, Chang Sung;Lee, Joo Won
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.4
    • /
    • pp.401-408
    • /
    • 2008
  • Purpose : Transcatheter closure of atrial septal defects (ASD) is currently established therapy as an alternative to surgery. But rarely, complications are reported in some studies. We report early and intermediate term complications associated with transcatheter closure of atrial septal defects using the Amplatzer septal occluder (ASO). Methods : From June 2003 to May 2006, 64 patients underwent transcatheter closure of secundum ASD or patent foramen ovale using the ASO. The ratio of male to female was 1:2.4, the median age was 17 years (range: 2.6-64 years) and their median weight was 47.5 kg (range: 2.6-64 kg). Results : The median diameter of ASD measured with transthoracic or transesophageal echocardiography was 15 mm (range: 6-28 mm), the median balloon stretched diameter was 18 mm (range: 6.5-34 mm), and the median size of device was 19.5 mm (range: 6-36 mm), was little difference with balloon stretched diameter. There were 10 cases of complications: arrhythmia (2), device malformation (2), aorta to right atrial fistula (1), hemolytic anemia (1), mitral valve encroachment (1), malposition (1), residual shunt (1), and inferior vena cava perforation (1). Conclusion : Transcatheter closure of ASD using ASO is effective and safe therapy. However, significant complications such as aorta to atrial fistula, atrial erosion, or device embolization can happen, so an appropriate selection of patient and device in relevance to size and anatomy of ASD is important for successful closure.

Analysis of Neurological Complications on Antegrade Versus Retrograde Cerebral Perfusion in the Surgical Treatment of Aortic Dissection (대동맥 박리에서 전방성 뇌 관류와 역행성 뇌 관류의 신경학적 분석)

  • Park Il;Kim Kyu Tae;Lee Jong Tae;Chang Bong Hyun;Lee Eung Bae;Cho Joon Yong
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.489-495
    • /
    • 2005
  • In the surgical treatment of aortic dissection, aortic arch replacement under total circulatory arrest is often performed after careful inspection to determine the severity of disease progression. Under circulatory arrest, antegrade or retrograde cerebral perfusion is required for brain protection. Recently, antegrade cerebral perfusion has been used more, because of the limitation of retrograde cerebral perfusion. This study is to compare these two methods especially in the respect to neurological complications. Material and Method: Forty patients with aortic dissection involving aortic arch from May 2000 to May 2004 were enrolled in this study, and the methods of operation, clinical recovery, and neurological complications were retrospectively reviewed. Result: In the ACP (antegrade cerebral perfusion) group, axillary artery cannulation was performed in 10 out of 15 cases. In the RCP (retrograde cerebral perfusion) group, femoral artery Cannulation was performed in 24 out of 25 cases. The average esophageal and rectal temperature under total circulatory arrest was $17.2^{\circ}C\;and\;22.8^{\circ}C$ in the group A, and $16.0^{\circ}C\;and\;19.7^{\circ}C$ in the group B, respectively. Higher temperature in the ACP group may have brought the shorter operation and cardiopulmonary bypass time. However, the length of period for postoperative clinical recovery and admission duration did not show any statistically significant differences. Eleven out of the total 15 cases in the ACP group and thirteen out of the total 25 cases in the RCP group showed neurological complication but did not show statistically significant difference. In each group, there were 5 cases with permanent neurological complications. All 5 cases in the ACP group showed some improvements that enabled routine exercise. However all 5 cases in RCP group did not show significant improvements. Conclusion: The Antegrade, cerebral perfusion, which maintains orthordromic circulation, brings moderate degree of hypothermia and, therefore, shortens the operation time and cardiopulmonary bypass time. We concluded that Antegrade cerebral perfusion is safe and can be used widely under total circulatory arrest.

ECG Signal Compression based on Adaptive Multi-level Code (적응적 멀티 레벨 코드 기반의 심전도 신호 압축)

  • Kim, Jungjoon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.6
    • /
    • pp.519-526
    • /
    • 2013
  • ECG signal has the feature that is repeated in a cycle of P, Q, R, S, and T waves and is sampled at a high sampling frequency in general. By using the feature of periodic ECG signals, maximizing compression efficiency while minimizing the loss of important information for diagnosis is required. However, the periodic characteristics of such amplitude and period is not constant by measuring time and patients. Even though measured at the same time, the patient's characteristics display different periodic intervals. In this paper, an adaptive multi-level coding is provided by coding adaptively the dominant and non-dominant signal interval of the ECG signal. The proposed method can maximize the compression efficiency by using a multi-level code that applies different compression ratios considering information loss associated with the dominant signal intervals and non-dominant signal intervals. For the case of long time measurement, this method has a merit of maximizing compression ratio compared with existing compression methods that do not use the periodicity of the ECG signal and for the lossless compression coding of non-dominant signal intervals, the method has an advantage that can be stored without loss of information. The effectiveness of the ECG signal compression is proved throughout the experiment on ECG signal of MIT-BIH arrhythmia database.

Design of a Holter Monitoring System with Flash Memory Card (플레쉬 메모리 카드를 이용한 홀터 심전계의 설계)

  • 송근국;이경중
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.251-260
    • /
    • 1998
  • The Holter monitoring system is a widely used noninvasive diagnostic tool for ambulatory patient who may be at risk from latent life-threatening cardiac abnormalities. In this paper, we design a high performance intelligent holter monitoring system which is characterized by the small-sized and the low-power consumption. The system hardware consists of one-chip microcontroller(68HC11E9), ECG preprocessing circuit, and flash memory card. ECG preprocessing circuit is made of ECG preamplifier with gain of 250, 500 and 1000, the bandpass filter with bandwidth of 0.05-100Hz, the auto-balancing circuit and the saturation-calibrating circuit to eliminate baseline wandering, ECG signal sampled at 240 samples/sec is converted to the digital signal. We use a linear recursive filter and preprocessing algorithm to detect the ECG parameters which are QRS complex, and Q-R-T points, ST-level, HR, QT interval. The long-term acquired ECG signals and diagnostic parameters are compressed by the MFan(Modified Fan) and the delta modulation method. To easily interface with the PC based analyzer program which is operated in DOS and Windows, the compressed data, that are compatible to FFS(flash file system) format, are stored at the flash memory card with SBF(symmetric block format).

  • PDF

Bilateral Popliteal Artery Entrapment Syndrome (양측성 슬와동맥 포착증후군)

  • Yoo, Dong-Gon;Kim, Chong-Wook;Park, Chong-Bin
    • Journal of Chest Surgery
    • /
    • v.40 no.2 s.271
    • /
    • pp.136-139
    • /
    • 2007
  • Bilateral popliteal artery entrapment syndrome is a rare vascular disease, which leads to ischemic claudication as a result of disturbance to the blood flow from the abnormal relationship of the popliteal artery to the gastrocnemius muscle, a fibrous band or the popliteus muscle in the young male population. A 58-years-old male patient, complaining of ischemic claudication, coldness and 3rd toe gangrene of left leg of 1 month's duration was admitted to our institution. His left ankle-brachial index was decreased; therefore, a femoral artery angiography was peformed, which revealed a total occlusion below the distal superficial femoral artery of the left leg. An EKG revealed atrial fibrillation, suggestive of a thromboembolism of the popliteal artery due to atrial fibrillation; therefore, Urokinase thrombolysis was attempted. After the Urokinase thrombolysis, popliteal artery entrapment syndrome was diagnosed, with MRI then performed for an anatomical diagnosis. The popliteal artery entrapment was type 1, where the popliteal artery was displaced medial to the Gastrocnemius head. After complete removal of the popliteal artery aneurysm, interposition was performed with a contra lateral greater saphenous vein graft. A mild right popliteal artery aneurysm still remained, but surgery was not performed. Currently, the patent is surviving, without complications. Herein, the good results obtained for the surgical treatment of a severely affected leg, and the conservative treatment of a mildly affected leg, are reported.

Effects of CP AP Therapy on Systemic Blood Pressure, Cardiac Rhythm and Catecholamines Concentration in Patients with Obstructive Sleep Apnea (폐쇄성 수면 무호흡에서 CPAP 치료가 전신성 혈압, 심조율 및 catecholamines 농도에 미치는 영향)

  • Kang, Ji-Ho;Lee, Sang-Haak;Choi, Young-Mee;Kwon, Soon-Seog;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Song, Jeong-Sup;Park, Sung-Hak;Moon, Hwa-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.6
    • /
    • pp.715-723
    • /
    • 2000
  • Background : Obstructive sleep apnea syndrome (OSAS) affects systemic blood pressure and cardiac function. The development of cardiovascular dysfunction including the changes of systemic blood pressure and cardiac rhythm, suggests that recurrent hypoxia and arousals from sleep may increase a sympathetic nervous system activity. Continuous positive airway pressure (CPAP) therapy has been found to be an effective treatment of OSAS. However, only a few studies have investigated the cardiovascular and sympathetic effects of CPAP therapy. We evaluated influences of nasal CPAP therapy on the cardiovascular system and the sympathetic activity in patients with OSAS. Methods : Thirteen patients with OSAS underwent CPAP therapy and were monitored using polysomnography, blood pressure, heart rate, presence of arrhythmia and the concentration of plasma catecholamines, before and with CPAP therapy. Results: The apnea-hypopnea index (AHI) was significant1y decreased (p<0.01) and the lowest arterial oxygen saturation level was elevated significantly after applying CPAP (p<0.01). Systolic blood pressure tended to decrease after CPAP but without statistical significance. Heart rates during sleep were not significantly different after CPAP. However, the frequency and number of types of arrhythmia decreased and sinus bradytachyarrhythmia disappeared after CPAP. Although there was no significant difference in the level of plasma epinephrine concentration, plasma norepinephrine concentration significantly decreased after CPAP (p<0.05). Conclusion : CPAP therapy decreased the apnea-hypopnea index, hypoxic episodes and plasma norepinephrine concentration. In addition, it decreased the incidence of arrhythmia and tended to decrease the systemic blood pressure. These results indicate that CPAP may play an important role in the prevention of cardiovascular complications in patients with OSAS.

  • PDF

Mid-term results of IntracardiacLateral Tunnel Fontan Procedure in the Treatment of Patients with a Functional Single Ventricle (기능적 단심실 환자에 대한 심장내 외측통로 폰탄술식의 중기 수술성적)

  • 이정렬;김용진;노준량
    • Journal of Chest Surgery
    • /
    • v.31 no.5
    • /
    • pp.472-480
    • /
    • 1998
  • We reviewed the surgical results of intracardiac lateral tunnel Fontan procedure for the repair of functional single ventricles. Between 1990 and 1996, 104 patients underwent total cavopulmonary anastomosis. Patients' age and body weight averaged 35.9(range 10 to 173) months and 12.8(range 6.5 to 37.8) kg. Preoperative diagnoses included 18 tricuspid atresias and 53 double inlet ventricles with univentricular atrioventricular connection and 33 other complex lesions. Previous palliative operations were performed in 50 of these patients, including 37 systemic to pulmonary artery shunts, 13 pulmonary artery bandings, 15 surgical atrial septectomies, 2 arterial switch procedures, 2 resections of subaortic conus, 2 repairs of total anomalous pulmonary venous connection and 1 Damus-Stansel-Kaye procedure. In 19 patients bidirectional cavopulmonary shunt operation was performed before the Fontan procedure and in 1 patient a Kawashima procedure was required. Preoperative hemodynamics revealed a mean pulmonary artery pressure of 14.6(range 5 to 28) mmHg, a mean pulmonary vascular resistance of 2.2(range 0.4 to 6.9) wood-unit, a mean pulmonary to systemic flow ratio of 0.9(range 0.3 to 3.0), a mean ventricular end-diastolic pressure of 9.0 (range 3.0 to 21.0) mmHg, and a mean arterial oxygen saturation of 76.0(range 45.6 to 88.0)%. The operative procedure consisted of a longitudinal right atriotomy 2cm lateral to the terminal crest up to the right atrial auricle, followed by the creation of a lateral tunnel connecting the orifices of either the superior caval vein or the right atrial auricle to the inferior caval vein, using a Gore-Tex vascular graft with or without a fenestration. Concomitant procedures at the time of Fontan procedure included 22 pulmonary artery angioplasties, 21 atrial septectomies, 4 atrioventricular valve replacements or repairs, 4 corrections of anomalous pulmonary venous connection, and 3 permanent pacemaker implantations. In 31, a fenestration was created, and in 1 an adjustable communication was made in the lateral tunnel pathway. One lateral tunnel conversion was performed in a patient with recurrent intractable tachyarrhythmia 4 years after the initial atriopulmonary connection. Post-extubation hemodynamic data revealed a mean pulmonary artery pressure of 12.7(range 8 to 21) mmHg, a mean ventricular end-diastolic pressure of 7.6(range 4 to 12) mmHg, and a mean room-air arterial oxygen saturation of 89.9(range 68 to 100) %. The follow-up duration was, on average, 27(range 1 to 85) months. Post-Fontan complications included 11 prolonged pleural effusions, 8 arrhythmias, 9 chylothoraces, 5 of damage to the central nervous system, 5 infectious complications, and 4 of acute renal failure. Seven early(6.7%) and 5 late(4.8%) deaths occured. These results proved that the lateral tunnel Fontan procedure provided excellent hemodynamic improvements with acceptable mortality and morbidity for hearts with various types of functional single ventricle.

  • PDF

Impact of fetal diagnosis of congenital heart disease on parents (선천성 심질환의 산전 진단이 보호자의 임신 유지 결정에 미치는 영향)

  • Choi, Eun Young;Lee, Chang Hoon;Yoon, Myung Ja;Han, Eun Sook;Hong, Joon Suk;Jung, Yun Sook;Choi, Jung Yun
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.10
    • /
    • pp.1073-1078
    • /
    • 2006
  • Purpose : This study was performed to assess how a fetal diagnosis of congenital heart disease affects parents, as regards pregnancy management and care of infants after birth. Methods : Database search to find out abnormal fetal echocardiography performed at Seoul National University Children's Hospital from July 1988 to June 2003 revealed 370 examinations. After excluding both arrhythmias without structural cardiac disease and multiple pregnancies, 299 pregnancies remained and this data formed the basis of this analysis. We retrospectively reviewed the medical records with special attention to pregnancy outcomes and also tried to find out factors influencing parental decisions on whether to continue or terminate pregnancy. Results : In this study, the mean gestation age at diagnosis was $28{\pm}6.0weeks$. The mean age of mothers was $30{\pm}3.9$ years old. Younger gestational ages at diagnosis(P=0.000), more severe grades of fetal heart disease(P=0.002) and younger mothers(P=0.014) correlated with terminations of pregnanies. But the grades of fetal status, the grades of associated anomaly, whether in-vitro-fertilization was carried out or not and numbers of previous children were not significant. Conclusion : This study found that the earlier gestational ages at diagnosis, younger maternal age and higher grades of fetal heart disease tended to lead parent to select abortions. Fetal echocardiographies were performed too late. Moreover Koreans have a biased view that malformation is a something incurable and a tragedy not only to oneself, but also to a family. So parents select terminations of pregnancy, even in curable cases. This is very unethical.

Changes of Microembolic Signals after Heart Valve Surgery (심장 판막 수술 후 미세색전의 변화)

  • 조수진;이은일;백만종;오삼세;나찬영
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.316-320
    • /
    • 2003
  • Background: The detection of circulating microemboli by transcranial Doppler ultrasonography (TCD) has the potential to select the patients with high risk for future symptomatic brain embolism. We prospectively evaluated the positive rate and the frequency of microembolic signals (MES) before and after the heart valve surgery (HVS). Material and Method: Fifty in-patients with heart valve disease were enrolled in this study. Patients with history of previous stroke or heart valve surgery were excluded. Two unilateral TCD monitoring sessions were peformed from middle cerebral artery for 1-hour, before and after HVS. Result: Mechanical Heart valves were implanted in 28 patients, tissue valves were implanted in 10 patients, and remaining 12 patients received mitral valve repair. Positive rate of MES was significantly increased after HVS (50%), compared to that of before HVS (8%, p=0.00). There was no relation between MES after HVS and intensity of anticoagulation, cardiac rhythm, patients' age, and history of hypertension. The positive rate of MES after implantation of mechanical heart valve (71.4%) was significantly higher than those after implantation of tissue valve or mitral valve plasty (p=0.002). Conclusion: Positive rate of MES was increased significantly after the implantation of HVS. The changes of MES in those with mechanical prosthesis may be related to the increased risk or embolism after Hvs.