• Title/Summary/Keyword: 부식 높이

Search Result 44, Processing Time 0.028 seconds

A STUDY ON THE BONDING OF COMPOMER TO DECIDUOUS DENTIN (컴포머와 유치 상아질의 결합에 관한 연구)

  • Kim, Jee-Tae;Kim, Yong-Kee;Kim, Jong-Soo;Kwon, Soon-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.509-518
    • /
    • 2002
  • The purpose of this study was to evaluate the bonding of compomer to deciduous dentin which is known to have been developed to improve the weak properties of glass ionomer cement and composite resin. 120 sound primary molars were used for the shear bond strength test and another 24 for the scanning electron microscopic evaluation. Each material was ailed into polyethylene mold attached to exposed dentinal surface($3{\times}4mm$ in diameter) of sample blocks. Shearbond strength was measured using Universal testing machine and data were analyzed statistically with Oneway-ANOVA and Scheffe test. Scanning electron microscopic observation was performed in order to evaluate the pattern of distribution and penetration of resin tags and hybrid layer. Compomer groups(II-V) showed significantly higher bond strength values than glass ionomer group(I)(p<.05). Etching-compomer groups(III, V) showed the significantly higher bond strength than non-etching compomer groups(II, IV)(p<.05), but slightly lower values than composite resin group(VI) with no statistically significant difference(p>.05). No significantly different bond strength was found between compomer groups of different bonding system(p>.05). Scanning electron micrographs showed more irregular distribution of short and thin resin tags in non-etching compomer groups(II, IV) whereas the more regular and intimate distribution of long and thick tags in etching compomer groups(III, V) and composite resin group(VI). The evaluation of hybrid layer also showed more regular formation of thicker layer in etching compomer groups(III, V). Based on the results of present study, the use of compomer as an esthetic restorative material for primary molars might be justified.

  • PDF

Evaluation of Static and Fatigue Performances of Decks Reinforced with GFRP Rebar for Reinfocement Ratio (GFRP 보강근으로 보강된 바닥판의 보강비에 따른 정적 및 피로성능 평가)

  • You, Young-Jun;Park, Young-Hwan;Choi, Ji-Hun;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.491-497
    • /
    • 2014
  • The corrosion of steel reinforcement in reinforced concrete bridge decks significantly affects the degradation of the capacity. Due to the advantageous characteristics such as high tensile strength and non-corrosive property, fiber reinforced polymer (FRP) has been gathering much interest from designers and engineers for possible usage as a alternative reinforcement for a steel reinforcing bar. However, its application has not been widespread, because there data for short- and long-term performance data of FRP reinforced concrete members are insufficient. In this paper, seven full-scale decks with dimensions of $4000{\times}3000{\times}240mm$ were prepared and tested to failure in the laboratory. The test parameter was the bottom reinforcement ratio in transverse direction. The decks were subjected to various levels of concentrated cyclic load with a contact area of $577{\times}231mm$ to simulate the vehicle loading of DB-24 truck wheel loads acting on the center span of the deck. It was observed that the glass FRP (GFRP) reinforced deck on a restraint girder is strongly effected to the level of the applied load rather than the bottom reinforcement ratio. The study results showed that the maximum load less than 58% of the maximum static load can be applied to the deck to resist a fatigue load of 2 million cycles. The fatigue life of the GFRP decks from this study showed the lower and higher fatigue performance than that of ordinary steel and CFRP rebar reinforced concrete deck. respectively.

Web-based Evaluation Framework for the Flood Warning Facilities and Operational System (홍수예경보 시설 및 운영시스템에 대한 웹기반의 평가체계)

  • Kang, Boo-Sik;Lee, Joo-Heon;Hong, Il-Pyo;Kwon, Jin-Wook
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1494-1498
    • /
    • 2009
  • 세계기상기구(WMO)에 의하여 홍수예경보시스템의 평가를 위하여 개발된 MOFFS Ver.3의 개선을 위하여 특정유역의 홍수방어체계의 취약성을 평가하고 홍수방어시스템의 완성도를 높이기위한 DSS-FOP를 개발하였다. DSS-FOP는 지점별, 홍수사상별로 예보시스템 운영결과를 간단한 평가양식에 나타내는 시스템이며, 홍수방어구조물(Flood control infra)과 홍수조절운영(Flood control operation)으로 분류한다. 홍수방어구조물은 수문관측, 홍수방어구조물, 홍수조절지휘소로, 홍수조절 운영은 자료처리 및 전송, 홍수예측모형, 예경보발령의 총 6가지 주요평가항목과 하부의 23가지 세부평가항목으로 구성하였다. 점수부여체계는 최대점수, 목표점수, 성과점수, 부족점수, 취약점수의 산정을 통하여 구조물인프라와 운영측면에서의 시스템취약부분을 평가 진단할 수 있도록 하였다. 개발된 DSS-FOP를 이용하여 국내의 한강유역과 UN/ESCAP 태풍위원회의 회원국인 태국의 Khlong U-Taphao 유역을 대상으로 적용하고 그 결과를 비교 평가하였다. 한강유역의 경우 하천정보센터 신설 및 조직강화로 인적자원측면에서 높은 성과점수를 보였으며, 향후 수문레이더 설치 등으로 관측분야에서의 개선이 기대된다. 태국의 Khlong U-Taphao 유역의 경우 목표수준을 다소 조정할 필요가 있으며, 비상행동계획의 마련이 시급하다. 더불어 홍수방어구조물에 대한 지속적인 투자가 필요한 상황이다. 이러한 DSS-FOP의 평가결과는 국가별, 유역별, 호우사상별로 관리되며, 태풍위원회 회원국의 적용 및 기술지침의 작성을 위해 많은 평가 및 조사가 축적되어야 한다.

  • PDF

Evaluation of Chloride Ion Penetration Characteristics for Concrete Structures at Coastal Area (해안지역 콘크리트 구조물의 염소이온침투특성 평가)

  • Han, Sang-Hun;Yi, Jin-Hak;Park, Woo-Sun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.23 no.1
    • /
    • pp.11-17
    • /
    • 2011
  • A major source of durability problems in concrete structures is the corrosion of steel by the damage of passivity layer around steel bars. As chloride ion penetration is major cause of the destruction of passivity layer, evaluation of depth and concentration profile of chloride ion is the essential factor for the service-life estimation of concrete structure. To estimate chloride ion penetration characteristics, this paper on the basis of in-situ experimental data investigated the depth and concentration profile of chloride ion penetration. The core specimens are obtained at air-zone, splash zone, and tidal zone in Wando, Masan, Incheon, Gwangyang, and donghae harbors. Colorimentric method measured the chloride ion penetration depth and ASTM C 114 evaluated the concentration profile of chloride ion. Based on experimental data, the influence of harbor location and exposure condition on chloride ion penetration is evaluated.

A Study on Enhanced Tubes for Electric Utility Steam Condensers (발전소 수증기 응축기용 전열 촉진관에 대한 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.31-41
    • /
    • 2016
  • A computer program that simulates electric utility steam condensers was developed, and used to investigate the effects of enhanced tubes in steam condensers. The replacement of smooth tubes with enhanced tubes reduces the steam condensing temperature, and increases the efficiency of the electric utility. Therefore, a significant amount of power may be reserved without any modification of the utility. Three enhanced tubes, corrugated, low fin with internal ribs, and low fin with internal 3-D roughness, were considered. The results showed that there is an optimal internal roughness height. Low fin tubes with a 3-D roughness were superior to the other enhanced geometries. This was attributed to longitudinal vortices generated between the circumferential dimples. An additional 0.5 MW~1.3 MW was possible when smooth tubes were replaced with enhanced tubes in the 600 MW electric utility condenser. The additional power increased with increasing coolant temperature. More investigations on fouling, corrosion, and mechanical properties will be necessary for actual applications of enhanced tubes in electric utility condensers.

근접셀렌화법을 의해 제조된 $Cu(In,Ga)Se_2$ 흡수층의 물성

  • Lee, Sang-Hwan;Seo, Jin-U;Lee, Eun-U;Park, Sun-Yong;Kim, U-Nam;Jeon, Chan-Uk
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.34.2-34.2
    • /
    • 2010
  • Cu(In,Ga)Se2 (CIGS) 화합물 반도체를 기반으로 한 태양전지는 박막태양전지 기술 중 세계최고효율을 기록하고 있다. CIGS를 합성하는 방법은 동시증발법, 스퍼터링/셀렌화 등의 진공방식과 나노분말법, 전착법, 용액법 등의 비진공방식이 있으나, 현재까지 진공방식이 양산기술로서 완성도가 높은 것으로 알려져 있다. 특히 스퍼터링에 의한 전구체 박막 증착과 셀렌 분위기에서의 열처리 공정을 결합시킨 2단계 공정은 동시증발법에 비해 대면적 모듈 제조에 유리한 것으로 알려져 있다. 셀렌화 공정은 통상 반응성이 매우 높은 H2Se 기체를 이용하고 있으나, 부식성 및 안전성 문제를 해결하기 위해 추가적인 설비가 요구되므로 제조비용을 높이는 단점을 갖는다. 한편, Se 증기를 이용하면 안전성은 담보되나 낮은 반응성으로 인해 고온에서 장시간 열처리를 해야하는 문제를 안고 있다. 본 연구에서는 새로운 Se 증기를 사용하되 반응효율을 높일 수 있는 새로운 셀렌화 열처리방법을 제시하고자 한다. 기존의 Se 증기가 별도의 증발원을 이용하여 공급된 것과는 달리, 금속전구체 직상부에 Se이 코팅된 별도의 커버글라스를 위치시켜 Se의 손실을 최대한 억제하였다. Se 커버글라스가 밀착된 금속프리커서를 $200{\sim}600^{\circ}C$ 온도범위에서 열저항가열로 내부에서 열처리하였으며, 추가로 Se을 공급하지는 않았다. 이와 같은 방법 제조된 CIGS 박막의 물성을 X선회절법, 주사전자현미경 등으로 관찰하였으며, 예비실험결과 비교적 낮은 온도에서 chalcopyrite 상이 형성됨을 확인하였다. 근접셀렌화에 의해 제조된 CIGS 박막이 적용된 태양전지를 제조하여 셀렌화 공정변수에 따른 소자특성변화를 제시하고자 한다.

  • PDF

An Approach to Risk Assessment of City Gas Pipeline (도시가스 배관의 위험평가 방법론 제시)

  • Park Kyo-Shik;Lee Jin-Han;Jo Young-Do;Park Jin-Hee
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.1 s.18
    • /
    • pp.33-40
    • /
    • 2003
  • In this work, a novel approach was introduced to assess cost of loss resulting from risk as well as to help deciding inspection period through quantifying risk. In order to quantifying risk of city gas pipeline, frequency and consequence analysis were required. The main causes of city gas accident were analyzed to be digging, external corrosion, ground movement, and equipment failure. Tools to evaluate frequency of each cause was also suggested. Among city gas accidents, fire damage is the dominant one and mainly discussed; fatality, burning injury, and damage to building were estimated using the consequence model suggested. By combining frequency and consequence analysis, evaluating cost of risk management together with calculating example. This work could be applicable for city gas companies to plan how to manage risk most effectively.

  • PDF

Evaluation of Service Life in RC Column under Chloride Attack through Field Investigation: Deterministic and Probabilistic Approaches (염해 실태조사를 통한 철근 콘크리트 교각의 내구수명 평가 - 결정론적 및 확률론적 해석방법)

  • Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.5
    • /
    • pp.67-74
    • /
    • 2015
  • RC (Reinforced Concrete) structures are considered as cost-benefit and durable however performances of structural safety and durability are degraded due to steel corrosion. Service life in RC structure is differently evaluated due to different local environmental conditions even if it is exposed to the same chloride attack. In the paper, 25 concrete cores from field investigation are obtained from 4 RC columns with duration of 3.5~4.5 years exposed to sea water. Through total chloride content measurement, surface chloride contents and apparent diffusion coefficients are evaluated. Service life of the target structure is estimated through deterministic method based on Fick's $2^{nd}$ Law and probabilistic method based on durability failure probability, respectively. Probability method is evaluated to be more conservative and relatively decreased service life is evaluated in tidal zone and splash zone over 40.0 m. Chloride penetration behavior with coring location from sea level and the present limitations of durability design method are investigated in the paper.

Characteristic Analysis of Inflow and outflow Using Erosion Control Dam in the Mountainous Watershed (산지유역에서의 사방댐 위어를 이용한 유입량 및 유출량 특성 분석)

  • Moon, Duck Young;Lim, Kwang Suop
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.487-487
    • /
    • 2015
  • 우리나라의 강우 특성 상, 여름철에 집중되는 강우로 인해 홍수가 빈번히 발생하고 겨울과 봄에는 수자원이 부족한 현상이 발생한다. 또한 최근 기후변화에 따라 홍수와 가뭄의 강도와 빈도가 증가하고 있으며, 그로 인한 피해는 점차 증가하고 있다. 이러한 기후변화에 대응하여 효율적인 수자원 관리를 위해서는 저수지와 댐에서의 정량적인 물관리가 필요한 실정이다. 신뢰도 높은 저수지 수문자료 생성을 위하여 상류지역에서 저수지로의 유입량을 정확히 계측하는 것은 저수지 관리에서 무엇보다도 중요하다. 하지만 저수지 상류의 경우에는 대부분 산지 계곡 지형으로 이루어져 일반적인 유량측정에 사용되는 프로펠러 유속계를 이용한 도섭법 유량측정의 경우 많은 제약이 있다. 또한 이에 따른 유량 측정의 신뢰도가 매우 낮아지는 어려움이 존재한다. K-water 연구원은 이러한 문제점을 해결하고 신뢰도 높은 유량측정을 위해서 2012년 10월, 전북 무주군에 위치한 덕곡제 상류 1km 지점의 사방댐에 예언위어를 설치하여 유량측정을 실시하였다. 사방댐은 보통 계곡과 같은 하상구배가 큰 산지 지형에서 갑작스런 강우에 의해 발생하는 급류로 산사태가 일어나는 것과 토사 유출을 방지하기 위해 건설되며, 이러한 사방댐에 예언위어의 설치를 통해 사방댐의 기존용도 외에 유량측정도 할 수 있도록 하였다. 사방댐의 형태를 유지하면서 유량 측정을 위해 폭 12m, 높이 20cm의 예언위어를 설치하였고, 부식을 방지하기 위해 스테인리스 재질을 선택하였다. 사방댐에 설치된 위어로부터 측정된 수위를 유량 환산식에 대입을 함으로써 간단하게 유량산출을 가능하게 하였다. 사방댐에 설치된 위어에 기포식 수위계를 설치하여 30분 단위로 수위를 측정하여 유출량을 측정하였다. 또한 근처의 플럭스 타워에 설치된 강우량계에서 측정된 강우량을 통하여 유입량을 산정하였고, 이를 통하여 유출률을 분석하였다. 이와 같이 사방댐을 활용한다면 인력에 의한 유량측정보다 저비용으로 신뢰도 높은 유량 자료를 얻을 수 있으며, 이를 통해 저수지에서 합리적이고 효율적인 수자원 관리를 할 수 있을 것이라 판단된다.

  • PDF

The Organization of Interface for safety and reliability of Urban Maglev Third rail System (도시형 자기부상열차 제3궤조 전차선로의 안전성 및 신뢰성 확보를 위한 인터페이스 정립)

  • Min, Byong-Chan;Cho, Sang-Hoon;Heo, Young-Tae;Hong, Du-Young;Kim, Chang-Hwan;Jeong, Nam-Cheol
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1189-1194
    • /
    • 2011
  • The Maglev train is operated by levitating from a power of a large number of magnets and moving without direct contact to railway track so that reduces noise and vibration due to mechanical friction. Also, the Maglev passes sharp curves and steep hill without any difficulties. The Maglev has a potential to be an alternative transport system urban areas. For successful commercializing of Maglev, the organization of interface for safety and reliability of third rail system are one of the key considerations. Especially, the components of the third rail system, such as power rail, expansion joints, FRP section insulator, and supporter with epoxy insulator, should be durable, convenient for construction, and easy to maintenance. This paper analyzes the characteristics of the third rail system components and proposes organization of interface for system engineering. The operating tests of KIMM for the proposed third rail system verify the safety. Also, this paper analyzes the life cycle of the system components to improve the system reliability and evaluation.

  • PDF