The Journal of the Korean bone and joint tumor society
/
v.14
no.2
/
pp.140-145
/
2008
After limb salvage operation becomes popular, reconstruction method of epi-metaphyseal osteosarcoma is relatively standardized though it may be operator's matter of preference. Most limb salvage techniques presently used are prosthesis reconstruction and osteoarticular allograft. In the case of prosthesis, it is very stable and shows good postoperative functional score, however, finally, it has a weak point of requirement for removal procedure due to failure. In the long run, allograft reconstruction has a good merit. But, it has a weak point of difficulties in securing the demanded size and shape. Allograft reconstruction should be performed only in the case of safe margin and established indication. In limb salvage operation, intercalary reconstruction is useful method in diaphyseal osteosarcoma, however, in metaphyseal osteosarcoma, the indication is not confirmed. We treated 17 year old osteosarcoma patient with localized in the tibial medial condyle with proximal medial condylectomy and pasteurized bone reconstruction in the conviction of safe surgical margin. We report this case because we guess if this procedure may be applied to premature patients, despite failure hemiarthroplasty can be tried successfully.
When fish meat is washed for the processing of surimi, about 50ff of lipid in the fish meat is removed from the fish meat to the effluent. The removed lipid was easily recovered by centrifugation or filteration of wastewater washed fish meat. Then, the recovered lipid was utilized as a material of mayonnaise sauce processing. The major fatty acids in the recovered lipids are $C_{16:0},\;C_{18:0},\;C_{16:1},\;C_{20:5},\;and\;C_{22:6}$ Polyenoic fatty acids were composed of $33.6\%$ to total fatty acids. When the recovered lipid was substituted for soybean oil in processing of mayonnaise sauce, the maximum percentage of substitution ratio presumed to be $30\%$ according to viscosity, color difference, and emulsion stability evalution for the substituted ones.
Purpose: The aim of this study was to evaluate short-term clinical results and second-look arthroscopic findings after double-bundle anterior cruciate ligament (DB ACL) reconstruction. Materials and Methods: Forty-nine patients, who were followed up for at least 24 months after DB ACL reconstruction, were included. Clinical results, such as, Lysholm knee and Tegner activity scores, and manual laxity and instrumented anterior laxity test results were evaluated. In fifteen patients (15 knees), second-look arthroscopy with staple removal was performed. At second-look arthroscopy, the authors assessed about reconstructed ACL rupture, subjective graft tension and extent of synovial coverage. Results: Lysholm knee scores significantly improved from 67.4 preoperatively to 96.1 at last follow-up (p<0.01). Tegner activity scale improved from 2.0 to 6.1. The Lachman test, at last follow-up, showed normal laxity in 39 (of 49) patients, and the pivot-shift test showed normal laxity in 36 (of 49) patients. Mean side-to-side differences improved significantly from 10.8 mm to 3.3 mm (p<0.01). Second-look arthroscopic findings showed that all patients had a normal or a near normal anteromedial bundle. However, 8 patients (53.3%) were found to have partial or complete posterolateral bundle rupture. Conclusion: Even though double-bundle ACL reconstruction was clinically effective means of restoring knee rotational and anteroposterior stabilities, there were some ruptured posterolateral bundles observed in cases under arthroscopy after double-bundle ACL reconstruction.
Kim, Jong-Tae;Park, Hyung-Choon;Bang, Eun-Seok;Park, Heon-Joon;Kim, Dong-Soo
Journal of the Korean Society for Nondestructive Testing
/
v.27
no.2
/
pp.105-114
/
2007
Two-dimensional imaging of $V_s$ profile becomes more important in Korea because of the large horizontal variation of soil stiffness. To obtain a shear-wave velocity profile in geotechnical practice, various seismic nondestructive investigation methods are being frequently used. In this study, harmonic wavelet analysis of wave (HWAW) method is applied to the determination of $V_s$ profile to overcome some of weaknesses in the existing surface wave methods. HWAW method which is based on time-frequency analysis using harmonic wavelet transform has been developed to determine phase and group velocities of waves. Field testing of this method is relatively simple and fast because one experimental setup which consists of one pair of receivers is needed to determine $V_s$ profile of site. The proposed method uses the signal portion of the maximum local signal/noise ratio to evaluate the phase velocity to minimize the effects of noise, and uses single array inversion which considers receiver locations. Field tests were performed in 2 sites in order to evaluate accuracy of test method and estimate the applicability of 2-D imaging by HWAW method. Through field applications and comparison with other test results, the good accuracy and applicability of the proposed method were verified.
For the simple rapid bioassay of organophosphorus and carbamate pesticide residues, a mass-production system of acetycholinesterase (AChE, EC 3.1.1.7, MAChE) using baculovirus and insect cell culture was constructed. The cDNA for AChE was synthesized from Drosophila melanogaster in Halla Mountain, the lipid anchor tail was removed by PCR and was used for the site-directed mutagenesis of three amino acid residues (E107Y, F368L, L408F). The mutated cDNA was inserted into the baculovirus vector and expressed in insect cells. Maximum cell growth and enzyme activity were reached when the cells $(2{\times}10^6\;cell/ml)$ were infected four times at four-day-intervals. His-tag containing MAChE was purified using Ni-NTA column and used for characterization. The activity was maintained under various pHs (3-10) and temperatures $(20-50^{\circ}C)$ under experimental conditions. As an extraction solution for pesticides, methanol is more effective than ethanol. Against major organophosphate and carbamate pesticides, the MAChE showed better sensitivity than AChE and AChE from housefly (Taiwan).
The fibrin sealant was first designed as an alternative to surgical suture for the purpose of surface-to-surface union especially in parenchymal organs like the liver, spleen and kidney. The clinical application of currently used fibrin sealant was first introduced in 1972. The fibrin sealant consists of principal two components; lyophilized human fibrinogen and bovine thrombin. The fibrinogen component also contains coagulation factor XIII. A solution of aprotinin, an inhibitor of fibrinolysis is used to dissolve the fibrinogen and to provide the first component, and a solution of calcium chloride is also used to provide the second component. From July to December in 1990, during 6 months, we used fibrin sealant in the 28 patients of 33 various cases, in the following ways; supportive application of fibrin sealant after free autogenouse nerve graft for the repair of inferior alveolar nerve, facial nerve or accessory nerve, treament of hemangioma or lymphangioma to thrombosize and lead to the tumor shrinking, skin grafting to stimulate the adhesion and tissue repair, bone grafting in the patients of cleft alveolus, mandibular reconstruction or orthognathic surgery to facilitate the knitting of bone chips, tissue adhesion after tumor resection, radical neck dissection or flap reconstructions, and supportive adhesion of external auditory cannal after TMJ surgery via postauricular approach. No adverse effects were observed, none of the patients developed hepatitis or other blood transmitted disease, and the wound healing were acceptable.
Hollow-fiber membranes, is one of the new technologies that is growing rapidly in the past few decades. In addition, separation membranes using polymer materials, have attracted attentions in various fields including gas separation, fuel cells, water treatment, wastewater treatment, and organic separation. Nanofiltration (NF) membranes having the separation characteristics in the intermediate range between ultrafiltration and reverse osmosis (RO) membranes for liquid separation, with relatively low investment cost and operating pressure lower than that of RO membranes, have high permeance and rejection performance of multivalent ions as well as organic compounds of molecular weight between $200{\sim}1000gmol^{-1}$. In this paper, we would like to review the research trends on the various structure control and characterization of NF hollow fiber membranes with respect to materials and the methods of preparation (phase inversion method and interfacial polymerization method). Currently, most of NF membranes have been manufactured by plate and frame types or spiral wound types. But hollow fiber types have delayed in commercial products, because of the weak strength when to produce on the basis of the existing materials, therefore the development of new materials or improvement of existing materials will be needed. If improving manufacturing technology is available, hollow fiber types will replace spiral wound types and gradually show a higher market share.
Journal of the Institute of Electronics Engineers of Korea SP
/
v.44
no.1
/
pp.94-104
/
2007
Iris recognition is biometric technology which uses a unique iris pattern of user in order to identify person. In the captured iris image by conventional iris recognition camera, it is often the case with eyelid occlusion, which covers iris information. The eyelids are unnecessary information that causes bad recognition performance, so this paper proposes robust algorithm in order to detect eyelid. This research has following three advantages compared to previous works. First, we remove the detected eyelash and specular reflection by linear interpolation method because they act as noise factors when locating eyelid. Second, we detect the candidate points of eyelid by using mask in limited eyelid searching area, which is determined by searching the cross position of eyelid and the outer boundary of iris. And our proposed algorithm detects eyelid by using parabolic hough transform based on the detected candidate points. Third, there have been many researches to detect eyelid, but they did not consider the rotation of eyelid in an iris image. Whereas, we consider the rotation factor in parabolic hough transform to overcome such problem. We tested our algorithm with CASIA Database. As the experimental results, the detection accuracy were 90.82% and 96.47% in case of detecting upper and lower eyelid, respectively.
Gutta-percha와 근관sealer를 사용한 근관 충전은 가장 많이 이용되고 성공률이 높은 방법이지만, 현재 사용되는 모든 근관sealer는 미세누출을 나타낸다. 따라서 더 효과적인 근관 폐쇄를 이루기 위한 재료 및 방법들이 연구되어왔다. 이중 상아질 접착제는 근관 충전재와 함께 사용되어 미세누출을 감소시키지만, 근관 내에 사용하기에 술식이 복잡하고 기술이 요구된다. 본 연구의 목적은 gutta-percha와 레진계 근관 sealer로 충전한 근관에서 self-etching primer를 미리 도포한 경우와 도포하지 않은 경우의 치근단 미세누출을 비교하고, self-etching primer를 도포함에 있어 근관 내에 적용하는 방법에 따른 미세누출을 비교하는 것이다. 또한 근관sealer와 상아질 계면을 주사전자현미경으로 관찰하여, 이 결과를 미세누출과 관련시켜보고자 하였다. 36개의 발거된 사람의 단근치에서 치관부를 절단, 제거하고 ProFile로 근관 형성한 후, 무작위로 선택하여 4개의 군으로 분류하였다. 1군에서는 주사기와 30게이지 주사 바늘로 self-etching primer를 근관 내에 적용하였고, 2군에서는 self-etching primer를 paper point에 적셔 근관 내에 적용하였다. 3군에서는 self-etching primer를 적용하지 않았다. 1, 2, 3군의 치아를 gutta-percha와 AH26 sealer를 사용하여 continuous wave 충전법으로 충전한 후 치근단공 주위 3mm를 제외한 치근변에 nail polish를 2회 도포하였고, 4군(음성 대조군)은 치근면 전체에 도포하였다. 1군과 2군에서 각각 2개의 치아는 주사전자현미경적 관찰을 위해 준비하였다. 모든 치아를 Methylene Blue 수용액에 48시간동안 침적, 수세한 후 치아 장축에 평행하게 양분하여 10배의 실물확대현미경 하에서 치근단 색소 침투를 관찰하였다. Self-etching primer를 도포한 군과 도포하지 않은 군 사이에는 평균 미세누출량에 유의한 차이가 없었다. 주사 바늘로 적용한 군과 paper point로 적용한 군 사이에도 평균 미세누출량에 유의한 차이가 없었다. 상아질과 근관 sealer계면의 주사전자현미경 관찰 결과 일부분에서 긴밀한 접착 관계를 나타내었고, 다른 부분에서는 간극을 나타내었다.
About 2-year old northern goshawk (Accipiter gentilis) which is designated as natural monument (#323-1) in Republic of Korea was rescued by a local farmer and presented with a 2-weeks history of pain, swelling, stiffness and limping. On physical examination, plantar pododermatitis and digit IV weakness were observed. Radiographic findings also showed bone lyses with soft tissue swelling in the foot. A definite diagnosis was made as stage III bumble foot after multidisciplinary approach of the patient. Bacterial culture was performed, and concurrently antibiotic susceptibility testing is determined using wound site exudates specimen. Bacterial isolates were identified as Staphylococcus aureus, known normal skin flora. Treatment was initiated with surgical incision and necrotized tissues removal. Lavage-drainage and ball bandage were applied with topical mupirocin ointment application. Doughnut shaped pad was attached on bottom of the ball bandage to reduce weight bearing. After three weeks of intensive care, the wound site completely healed but digit IV weakness remained permanently. The goshawk returned to nature after eight weeks after treatment.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.