• Title/Summary/Keyword: 부분절연

Search Result 363, Processing Time 0.025 seconds

Measurement of Glass Sintering Degree by Electro-chemical Method (전기 화학적 방법을 이용한 소결도의 측정)

  • 차재민;김웅식;이병철;류봉기
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.6
    • /
    • pp.553-559
    • /
    • 2003
  • PDP rib is one of the important parts of manufacturing process and the sintering degree of rib plays an important role to prevent some problems such as cross talk. Nowadays, the screen-printing method, which is a low price and high production, is used to make a rib. However, it is hard to judge and value the sintering ratio of sintered body itself. In this study, we measured the sintering degree by the dielectric breakdown of pores with the potentiostat. We conformed that this has similar tendency to density of sintered samples and an error being expected by open and closed pores was inspected by change of the microstructure to scanning electron microscope. This result showed that the sintering degree of PDP rib could be analyzed into the electro-chemical method.

Junction Capacitance Dependence of Response Time for Magnetic Tunnel Junction (터널링 자기저항 소자의 접합면 정전용량에 따른 전기적 응답특성)

  • Park, S.Y.;Choi, Y.B.;Jo, S.C.
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.2
    • /
    • pp.68-72
    • /
    • 2002
  • In this research, the effects of capacitance to the access time were studied at the junction area of tunneling magnetoresistance when these were used as memory devices. These results were obtained by applying electric signal input and magnetic field was not used. We applied bipolar square waves of 1MHz to the MTJ samples to obtain the results and time constant ($\tau$) calculated by observing wave responses utilizing an oscilloscope. And time constant was compared with junction area. Each part of MTJ sample, such as electrical pad, lead and contact area, was modeled as an electrical equivalent circuit based on experimental results. For the 200㎛$\times$200㎛ cell, junction capacitance was 90 pF. Also, measurement and simulation results were compared, which showed those similarity.

Analysis of Partial Discharge Characteristics in SF6 Gas Insulation (SF6 가스절연에서 부분방전의 특성분석)

  • Kim, Sun-Jae;Wang, Guoming;Park, Seo-Jun;Kil, Gyung-Suk;An, Chang-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.7
    • /
    • pp.429-434
    • /
    • 2016
  • This paper deals with the characteristics of partial discharge (PD) for the purpose of a condition based maintenance (CBM) of gas insulated switchgears (GIS) in power equipment. Four types of electrode systems such as a protrusion on enclosure (POE), a particle on spacer (POS), a free particle (FP) and a Floating were designed and fabricated. PD pulses were measured using UHF sensor with a frequency range of 300 MHz~1.4 GHz and a DAQ with a sampling rate of 250 MS/s. Discharge inception voltage (DIV), discharge extinction voltage (DEV), and phase resolved partial discharge (PRPD) were analyzed depending on electrode systems. The average DIV in the POS was 28.8 kV. It was about 1.7 times higher than that in the FP, which was the lowest value of 17.2 kV. The FP shuffled and jumped at the applied voltage of 23.5 kV. Over 95% of PD pulses in the POE were generated in the negative polarity ($181^{\circ}{\sim}360^{\circ}$) of applied voltage. The results showed the phase (${\Phi}$)-magnitude (dBm) of PD pulses by UHF sensor, a cluster was formed separately depending on electrode systems.

A Life Prediction of Insulation Degradation Using Complex Sensing System (복합 감지 시스템을 이용한 부분방전의 절연열화 수명추정)

  • Kim, S.H.;Kim, J.H.;Park, J.J.;Choi, J.K.;Yoon, H.J.;Lee, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.348-350
    • /
    • 1997
  • Because of internal voids ininsulators give rise to partial discharge(PD), which cause local breakdown and even entire insulation breakdown. Treeing due to PD is one of the main causes of breakdown of the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation has become important. From this viewpoint, our studies diagnose insulation degradation using the method of computer sensing system, which has the advantages of PD and acoustic emission(AE) sensing system. To use advantages of these two methods can be used effectively to search for treeing location and PD in some materials. In analysis method of degradation. We analyzed the PD pulse and AE pulses by regression analysis, compared to these obtained the correlation coefficient and determination coefficient by T-distribution and saw that PD and AE pulses show a similar pattern on the whole. Finally using statically operator such as the center of gravity(G), the gradient of the discharge distribution(C), we have analyzed for the prediction of life which we can be obtained the time, occurred of many pulse of small discharge amplitude.

  • PDF

평판 디스플레이의 효율화를 위한 진공 인-라인 실장기술에 관한 연구

  • 권상직;홍근조;성정호;이창호;권용범
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.45-45
    • /
    • 2000
  • PDP, FED, 그리고 VFD와 같은 마이크로 전자디스플레이 장치를 제작하기 위한 가장 중요한 기술중에 하나인 패널 내를 고진공으로 만드는 것과 초기의 진공을 유지하는 것이다. PDP 디스플레이는 전면판과 후면판으로 구성되어 있다. 전면판은 ITO전극, 절연체 그리고 MgO보호막으로 구성되어 있으며, 후면판은 어드레스 전극, 반사층, 격벽, 그리고 형광체층이 있다. 기존의 방식은 대기에서 프릿 글라스를 이용하여 두 장의 유리를 봉입하고, 후면판 모서리 부분에 있는 구멍에 배기 글라스 튜브를 붙이고, 튜브를 통해서 배기하고, 플라즈마 가스를 채우고, 최종적으로 tip-off를 한다. 이러한 기존의 방식을 통해서는 배기 컨덕턴스의 한계로 얻을 수 있는 초기 진공도에 한계가 있다. 아울러 두 장의 유리사이는 150$\mu$m 정도의 간격으로 되어 있고, 이웃한 격벽사이는 320$\mu$m 정도의 미세한 공간이 주어지는 구조가 컨덕턴스를 저하시킨다. 이와 같은 초기 진공도의 한계성을 극복하기 위한 연구로서, PDP 패널을 구성하는 두 장의 글라스를 진공 챔버내에서 IR heater를 이용하여 실장하였다. 대개 PbO, ZnO, SiO2,, 그리고 B?로 구성된 프릿 글라스를 대기에서 전면판에 dispensing하고 가소한다. 그리고 프릿 글라스가 형성된 전면판과 후면판을 loading, align 한 다음, 2 10-7torr까지 펌핑한 후 heating, holding 그리고 cooling 공정을 수행하므로 써 두 장의 유리를 실장하였다. 그러나 온도의 non-uniformity, 프릿 성분에 따라서 crack과 기포문제가 진공 실장과정에서 발생하였다. 이와 같은 문제를 개선하기 위해 프릿 글라스의 새로운 조성과 온도 uniformity를 유지하므로써, 프릿 글라스의 기포와 crack 발생없이 재현성 있게 진공 실장하였다. Leak channel 형성유무를 검증하기 위하여 챔버 자체의 펌핑 속도와 제작된 패널의 펌핑 속도를 비교하므로써, leak channel형성 유무를 평가할 수 있는 방법을 이용하였다. 이와 같은 방법을 이용하여, crack 또는 기포가 있는 패널은 leak channel을 형성하여 패널내의 진공을 유지할 수 없음을 검증하였고, crack 또는 기포가 없는 패널은 leak channel없이 패널내의 진공을 유지할 수 있음을 검증하였다. 결과적으로 진공 인-라인 실장시 가장 중요한 요인인 프릿의 변화를 분석하므로써, 고진공을 요구하는 FPD(PDP, FED, VFD)에 적합하게 적용할 수 있으며, 아울러 실장시 진공도를 개선하므로 패널내부의 오염을 최소화하여 디스필레이로서의 효율을 극대화할 수 있을 것이다.

  • PDF

Electric Fan Heater Design for Eco-Energy Saving (친환경 에너지 절감형 전기온풍기 기구설계)

  • Sul, Yong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.474-479
    • /
    • 2016
  • As the Eco-energy is recently required, electrical energy is fast increased. Several induction heating methods are attractive for Eco-energy and energy saving. In this paper, electrical fan heater was designed and developed with new concept for energy saving by electromagnetic induction heating. Proposed system was composed of three module, blast part, induction heating part and power transformation part. Induction heating method was adapted for heating and the resonant inverter was used for increasing of the power transformation efficiency. Full-bridge resonant inverter was adopted to resonant inverter. This system was composed of induction heating part made with metal(SUS 40 series), and power transformation part made with rectifier module, filter module and resonant inverter. From these results, the proposed new electric heater could be saved the energy from faster increasing the temperature compared to commercial gas and other electric heater. This electrical fan heater is possible to be used in field of home, commercial and agricultural area for eco-energy saving heater.

An Experimental Study on the Damage of the Data Process Equipment When $CO_2$ is Discharged ($CO_2$ 소화설비 방사시 정보저장장치의 저온손상에 관한 연구)

  • 이수경;김종훈;김영진;최종운
    • Fire Science and Engineering
    • /
    • v.13 no.3
    • /
    • pp.19-26
    • /
    • 1999
  • $CO_2$ extinguishing system is the most $\phi$pular among the gas extinguishing system. $CO_2$ is usually stored with liquified state. But, it gasifies at the tip of nozzle when $CO_2$ was released through the pipe and head. A ro$\alpha$n temperature is very low when $CO_2$ was released. So electrical instrument, magnetic storage equipment and memory semiconductor are electrically or physically injured by cooling effect in a few minutes. So, we intend to find out temperature profile and electrical damage in compartment area, and supply basic d data for research and making standards and code through the full scale experiment. As result of experiment on the damage due to cooling effect from $CO_2$ extinguishing system, i instantaneous discharging temperature. was $-82.5^{\circ}C$ in average. An average temp. in the compartment after discharging $CO_2$ was $-40^{\circ}C$.

  • PDF

A Study on the Partial Discharge Phase Properties with Branch Type Eleotrical Tree Growth in XLPE Cable Insulation (XLPE 케이블 절연체에서의 가지형 전기트리 성장에 따른 부분방전 위상 특성 연구)

  • Gang, Dong-Sik;Seon, Jong-Ho;Kim, Wi-Yeong;Lee, Hong-Sik;Park, Jeong-Hu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.5
    • /
    • pp.213-221
    • /
    • 2002
  • In order to improve the reliability of XLPE cables, it is necessary to find the useful diagnostic parameter according to long term aging. This paper described the change of partial discharge(PD) phase Properties of XLPE cable insulation with branch type electrical tree degradation. for long term aging. To understand the PD Properties with $\phi$ -q-n distributed shape of XLPE insulation, specimens were prepared by 22.9㎸ distribution cable and made in a type of block(16${\times}$16${\times}$3[mm]). Ogura needles having tip radius of l0${\mu}{\textrm}{m}$ were inserted into each block pieces. The measuring system was consisted of PD detector, digitizer for digital conversion, VXI system for signal processing. The PD properties of the specimens were measured from initiation of tree to breakdown and their characteristics were analyzed. We analyzed the relationship between electrical properties(PD Quantity, PD initiation angle, PD extinction angle, PD occurrence angle : (PD extinction angle - PD initiation angle)) and the normalized aging rate. We found PD parameter, PD initiation angle and occurrence angle, which are a useful diagnostic parameter in estimating the branch type electrical tree for XLPE insulation condition.

Fabrication of Low Power Micro-heater for Micro-Gas Sensor I. The Thermal Distribution Analysis by The Finite Element Method (마이크로 가스센서를 위한 저전력 마이크로 히터의 제조 I. 유한요소법에 의한 열분포해석)

  • Chung, Wan-Young;Lim, Jun-Woo;Lee, Duk-Dong;Yamazoe, Noboru
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.337-345
    • /
    • 1997
  • The micro heater with PSG/$Si_{3}N_{4}$ diaphragm and platinum heater pattern was designed for micro-gas sensor fabrication. The platinum heater and the platinum electrode for sensing layer were designed on the same plane and fabricated in the single photolithography process. The thermal analyses including temperature distribution over the diaphragm and power consumption of the heater were carried by finite element method. The thermal properties of the microsensor with both heater and sensing electrode on the same plane was compared with that of the typical microsensor which had the structure of sensing layer/insulator/heater on the diaphragm.

  • PDF

Development of High Speed Circuit Breaker using Electromagnetic Repulsion Actuator (전자기 반발 구동장치를 사용한 고속 차단기 개발)

  • Hwang, Kwang-Soo;Kim, Young-Il;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.3
    • /
    • pp.441-448
    • /
    • 2022
  • In the distribution system, there are multiple power protection systems such as circuit breakers at substations, and reclosers, minimum circuit ampacities, fault interrupters on distribution lines. They are widely used to prevent partial outages, cascading power failure or blackout so that other healthy systems could maintain the integrity in case of the instant fault or permanent failure on the power lines. However, when a fault happens, it could cause a major black out due to the lack of the protection cooperation between the protection relay of the circuit breaker at a substation and a protection system on the distribution lines. To achieve the power system integrity better, it is required to develop the circuit breaker which can be operational within 1 cycle(16ms). In this study, the high speed circuit breaker which is filled up with eco-friendly gas is developed. This equipment achieved an excellent test results based on IEC 62271-111 standard. It is respected that this equipment would contribute to prevent the wide area blackout by isolating a fault area quicker and faster.