• Title/Summary/Keyword: 부가필터

Search Result 178, Processing Time 0.031 seconds

Development and Performance Evaluation of Positively Charged Porous Filter media for Water Purification System (정수 설비를 위한 양전하가 부가된 다공성 수처리 필터 개발과 성능평가)

  • Lee, Chang-Gun;Joo, Ho-Young;Lee, Jae-Keun;Ahn, Young-Chull;Park, Seong-En
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.95-98
    • /
    • 2006
  • Filtration by fibrous filter is one of the Principle methods used for removing pollutant particles in the liquid. Because of the increasing need to protect both human health and valuable devices from exposure to fine particles, filtration has become more important. Filters have been developed with modified surface charge characteristics to capture and adsorb particles by electrokinetic interaction between the filter surface and particles contained in water. The main purposes of this study are to develop and evaluate the performance evaluation of the apparatus for making a positively charged porous filter media and to analyze the surface characteristics of the filter media for capturing negavitely charged contaminants mainly bacteria and virus from water. The experimental apparatus consists of a mixing tank, a vacuum pumping system, a injection nozzle, a roller press and a controller. The filter media is composed of glass fiber(50-750 nm), cellulose($10-20{\mu}m$) and colloidal charge modifier. The characteristics of filter media is analyzed by SEM(Scanning Electron Microscopy), AFM(Atomic Force Microscopy) and quantified by measuring the zeta potential values.

  • PDF

Active Noise Control in Ductilike System using Adaptive Filtering (적응필터링에 의한 덕트계의 능동소음제어)

  • 이태연;김상명;송원식;오재응
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.17-22
    • /
    • 1991
  • 최근 기계장치로부터 발생하는 소음을 감소시키는 새로운 방법으로서, 능동 적으로 소음을 제어하는 방법에 대한 연구가 활발히 진행되고 있다. 이것은 원하지 않는 소음을 그 신호의 역위상을 갖는 부가음을 이용하여 능동적으 로 감쇠시키는 방법으로서, 저주파수 대역에서 비효율적인 수동적인 방법인 소음기둥에 대한 대안으로 많은 학자들의 관심의 대상이 되어 왔다. 초기에 는 소음을 줄이기 위해 요구되는 여러가지 음향요소의 전달함수를 제어하는 데 대한 불가능성으로 인해 능동 소음제어에 대한 실질적인 발전이 지연되 어 왔으나 최근 마이크로 컴퓨터를 비롯한 전자공학의 발전으로 인해 적응 신호처리 분야가 등장하게 되었으며, 음향계의 소음을 원하는 수준까지 제어 하는 능동 소음제어의 실시간 구현이 가능하게 되었다. 그 중에서도 음이 1 차원적으로 전파한다고 볼 수 있는 길이가 긴 덕트구조물에서의 능동 소음 제어는 가장 기본적이며 현실적으로 자동차 배기계나 냉동.공조설비에 있어 서 실용적으로 적용할 수 있는 문제임 만큼 많은 연구가 이루어지고 있다. 이러한 능동 소음제어 방법을 음향계에 적용하였을 때, 부가적인 음을 발생 하는 제어용 스피커로 인해 입력마이크로폰으로의 음향궤환이 존재하고 이 에 따라 제어계가 불안정해질 수 있으며, 또한 변환기의 사용으로 인한 부가 적인 전달함수가 존재하므로 이에 대한 중요한 의미를 갖고 고려하여야 한 다. 본 연구에서는 적응 필터링 이론에 의한 소음원의 입력신호에 대한 최적 한 예측으로써 부가음을 발생시키고, 입력신호 및 제어된 출력신호간의 차인 오차를 최소화 시키도록 하는 오차적응제어법을 이용한 능동소음 제어 방법 을 제시하였다. 이와 아울러 제어계의 환경변화에 따른 파라메타의 변화에 적응적으로 응답이 가능해야 하는 적응 소음제어 시스템에서, 음향궤환과 함 께 필히 고려해야 하는 부가적인 전달함수의 영향을 고려한 능동 소음제어 에 대해 연구하였다. 경량화 추세에 따라 지반이나 케이싱이 경량이거나 유연하여 회전축과 동적으로 연성된 경우 회전축-베어링-지반으로 이루어진 2중구조의 회전축 계 동특성을 해석할 수 있는 프로그램을 개발하므로서 회전 기계류의 진동 전반에 걸친 문제점에 대한 그 원인과 현상을 명확히 분석하여 국내의 전기 계류의 보다 신뢰성있는 설계 및 제작자료를 확보하는데 기여할 수 있게 하 였다.존의 small molecular Gd-chelate에 비해 매우 큼을 알 수 있었다. MnPC는 간세포에 흡수된 후 담도계로 배출되는 간특이성 조영제임을 확인하였다. 장비 내에서 반복 시행한 평균값의 차이는 대체적으로 유의한 차이가 없었으나, 다른 장비에서 반복 시행한 장비간의 사이에는 유의한 차이가 있는 경우가 더 많았다. 따라서 , MRS 검사를 소뇌나 뇌교의 어떤 절환에 적용하기 전에 각 장비 마다 정상 기준치를 반드시 얻은 후에 이상여부를 판 정하는 것이 필수적이라고 생각된다.EX> 이상이 적절한 진단기준으로 생각되었다. $0.4{\;}\textrm{cm}^3$ 이상의 좌우 부피차를 보이는 모든 증례에서 육안적으로도 해마위축이 뚜렷이 나타났다. 결론 : MR영상을 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both inflection fie이 and the maximum relaxivity value. The results shows a fluences on both inflection field

  • PDF

A Study on Electrodewatering Filter Press Technology for Improvement of Dewarterability of Waterworks Sludge (정수슬러지 탈수효율 향상을 위한 전기필터프레스탈수에 관한 연구)

  • Lee, Jung-Eun;Lee, Jae-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.10
    • /
    • pp.1009-1015
    • /
    • 2006
  • The elcetrodewatering filter press(EDFP) which had anode and cathod plates to be set between filter plates was built for reducing the waterworks sludge and improving performance of dewatering equipment. Several tests to compare the dewaterability with conventional mechanical filter press dewatering(MDEP) and EDFP was conducted through this equipment. As test results, filtration amount discharged from EDFP measured 43.2 kg which increased against MDFP, and cake weight measured 4 kg which was two times against MDFP. The water content of dewatered cake from EDFP was 55wt% and dewatering velocity was 2.3 $kg/m^2{\cdot}cycle$. This water content decrease 20% and dewatering velocity increased 30% with compare to the MDFP. That is to say, EDFP constructed from electrodewatering mechanism increase filtrate discharging amount, which make dewatering velocity increase and produce the low water content dewatered cake against MDFP. Energy consumption of EDFP is analysed to 400 kwh/DS ton. The results to analysis the economical aspect considering the power consumption and the handling cost decline as sludge volume reduction due to producing the low water content cake showed that expenses to handle sludge of 1 ton by dry solid base cut down on 20,000 won. If considering several test aspects, it was analysed that EDFP was excellent in the side of performance as well as economical suitability.

The Necessity of Resetting the Filter Criteria for the Minimization of Dose Creep in Digital Imaging Systems (디지털 영상 시스템에서 선량 크리프 최소화를 위한 부가 필터 두께 권고 기준의 재설정에 대한 연구)

  • Kim, Kyo Tae;Kim, Kum Bae;Kang, Sang Sik;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.757-763
    • /
    • 2019
  • Recently, Following the recent development of flat panel detector with wide dynamic ranges, increasing numbers of healthcare providers have begun to use digital radiography. As a result, filter thickness standards should be reestablished, as current clinical practice requires the use of thicknesses recommended by the National Council on Radiation Protection and Measurements, which are based on information, acquired using conventional analog systems. Here we investigated the possibility of minimizing dose creep and optimizing patient dose using Al filters in digital radiography. The use of thicker Al filters resulted in a maximum 19.3% reduction in the entrance skin exposure dose when medical images with similar sharpness values were compared. However, resolution, which is a critical factor in imaging, had a significant change of 1.01 lp/mm. This change in resolution is thought to be due to the increased amount of scattered rays generated from the object due to the X-ray beam hardening effect. The increase in the number of scattered rays was verified using the scattering degradation factor. However, the FPD, which has recently been developed and is widely used in various areas, has greater response to radiation than analog devices and has a wide dynamic range. Therefore, the FPD is expected to maintain an appropriate level of resolution corresponding to the increase in the scattered-ray content ratio, which depends on filter thickness. Use of the FPD is also expected to minimize dose creep by reducing the exposure dose.

Noisy Time Varying Vibration Signal Analysis using Adaptive Predictor-Binary Tree Structured Filter Bank System (적응예측기-이진트리구조 필터뱅크 시스템을 이용한 잡음이 부가된 시변 진동신호 분석)

  • Bae, Hyeon-Deok
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.1
    • /
    • pp.77-84
    • /
    • 2017
  • Generally, a time-varying vibration signal is generated in a rotating machine system, and when there is a failure in the rotating machine, the signal contains noise. In this paper, we propose a system consisting of an adaptive predictor and a binary tree filter bank for analyzing time - varying vibration signals with noise. And the vibration signal analyzed results in this system is used for fault diagnosis of the rotating machine. The adaptive predictor of the proposed system predicts the periodic signal components, and the filter bank system decomposes the difference signal between the input signal and the predicted periodic signal into subband. Since each subband signal includes a noise signal component due to a failure, it is possible to diagnose the failure of the using rotary machine. The validity of the proposed vibration signal analysis method is shown in the simulations, where the periodic components cancelled vibrating signals are decomposed to 32 subband, and the signal characteristics related faults are analyzed.

Human Body Tracking and Pose Estimation Using CamShift Based on Kalman Filter and Weighted Search Windows (칼만 필터와 가중탐색영역 CAMShift를 이용한 휴먼 바디 트래킹 및 자세추정)

  • Min, Jae-Hong;Kim, In-Gyu;Hwang, Seung-Jun;Baek, Joong-Hwan
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.3
    • /
    • pp.545-552
    • /
    • 2012
  • In this paper, we propose Modified Multi CAMShift Algorithm based on Kalman filter and Weighted Search Windows(KWMCAMShift) that extracts skin color area and tracks several human body parts for real-time human tracking system. We propose modified CAMShift algorithm that generates background model, extracts skin area of hands and head, and tracks the body parts. Kalman filter stabilizes tracking search window of skin area due to changing skin area in consecutive frames. Each occlusion areas is avoided by using weighted window of non-search areas and main-search area. And shadows are eliminated from background model and intensity of shadow. The proposed KWMCAMShift algorithm can estimate human pose in real-time and achieves 96.82% accuracy even in the case of occlusions.

Active Noise Control in Finite Duct by the FIR Filter Modelling Considering the Stuructural Characteristics (구조적특성을 고려한 유한 덕트계의 FIR필터모델링에 의한 능동소음제어)

  • Lee, Tae-Yeon;Song, Won-Shik;Oh, Jae-Eung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.11 no.2
    • /
    • pp.59-67
    • /
    • 1992
  • Recently, the problem which actively control the unwanted noise propagated from the technical structure by the generated secondary sound has become considerable topic from the environmental preservation point of view. In most of these studies, active noise control deals with a plane wave propagation at low frequency using adaptive filtering techniques. On the other hand, in real acoustic systems are mostly short due to the limitation of geometric configuration. In this case, the acoustic properties such as reflections and resonances inside the acoustic system should be considered. In this paper, the acoustic modeling method for short length duct was introduced using the transfer matrix method, and the active noise control problem was investigated with \implementation of FIR filter for the transfer function of control system derived from this modeling method. The identification methods for the acoustic model of actual control system was proposed by numerical computation technique based on the estimation of optimal FIR filter coefficients. The acceptable attenuation on the real acoustic system and stability of the controller are predicted in this computational simulation.

  • PDF

2~6 GHz Wideband GaN HEMT Power Amplifier MMIC Using a Modified All-Pass Filter (수정된 전역통과 필터를 이용한 2~6 GHz 광대역 GaN HEMT 전력증폭기 MMIC)

  • Lee, Sang-Kyung;Kim, Dong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.7
    • /
    • pp.620-626
    • /
    • 2015
  • In this paper, a 2~6 GHz wideband GaN power amplifier MMIC is designed and fabricated using a second-order all-pass filter for input impedance matching and an LC parallel resonant circuit for minimizing an output reactance component of the transistor. The second-order all-pass filter used for wideband lossy matching is modified in an asymmetric configuration to compensate the effect of channel resistance of the GaN transistor. The power amplifier MMIC chip that is fabricated using a $0.25{\mu}m$ GaN HEMT foundry process of Win Semiconductors, Corp. is $2.6mm{\times}1.3mm$ and shows a flat linear gain of about 13 dB and input return loss of larger than 10 dB. Under a saturated power mode, it also shows output power of 38.6~39.8 dBm and a power-added efficiency of 31.3~43.4 % in 2 to 6 GHz.

Development of Remote Monitoring System for groundwater purifier apparatus for community wells (마을 공동 우물용 지하수 정수 장치의 원격 모니터링 시스템 개발)

  • Kim, Dong-Jin;park, Sang-heup;Lee, Hong-Sup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.224-231
    • /
    • 2019
  • Recently, the pollution of groundwater has become serious. In particular, the contamination of groundwater near livestock farms is becoming increasingly severe and it is difficult to drink with drinking water. In this paper, a groundwater purifier apparatus that can be installed in a community well was designed. The designed groundwater purifier apparatus enables a RO membrane filter and UV sterilization to remove pollutants, such as heavy metals, bacteria, and organic compounds. In addition, electrical conductivity, pressure, and flow sensors were added for remote monitoring. Remote monitoring of the system can determine the level of fouling and contamination of RO membrane filters through pressure and flow sensor data, and can record changes in the contamination and condition of groundwater through the electrical conductivity of the feed water. The designed groundwater purifier apparatus was installed at a farmhouse and remote monitoring. The result after 15 days of operating a groundwater purifier apparatus and analyzing the monitoring data revealed an average permeate water flow rate of 2.67L/min and an average water pressure of 7.09kgf/㎠, indicating that the RO Membrane filtered without fouling and clogging. The average electrical conductivity was 796.6 S/㎠ of the feed water and 55.6 S/㎠ of permeate water, which is similar to that of general tap water. Through this, it was confirmed that no pollutant occurred in the surroundings. Therefore, the designed groundwater purifier apparatus can confirm the replacement time of the RO membrane filter in advance through remote monitoring, and check the pollution state of the groundwater.

Real-time Monocular Camera Pose Estimation using a Particle Filiter Intergrated with UKF (UKF와 연동된 입자필터를 이용한 실시간 단안시 카메라 추적 기법)

  • Seok-Han Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.5
    • /
    • pp.315-324
    • /
    • 2023
  • In this paper, we propose a real-time pose estimation method for a monocular camera using a particle filter integrated with UKF (unscented Kalman filter). While conventional camera tracking techniques combine camera images with data from additional devices such as gyroscopes and accelerometers, the proposed method aims to use only two-dimensional visual information from the camera without additional sensors. This leads to a significant simplification in the hardware configuration. The proposed approach is based on a particle filter integrated with UKF. The pose of the camera is estimated using UKF, which is defined individually for each particle. Statistics regarding the camera state are derived from all particles of the particle filter, from which the real-time camera pose information is computed. The proposed method demonstrates robust tracking, even in the case of rapid camera shakes and severe scene occlusions. The experiments show that our method remains robust even when most of the feature points in the image are obscured. In addition, we verify that when the number of particles is 35, the processing time per frame is approximately 25ms, which confirms that there are no issues with real-time processing.