DOI QR코드

DOI QR Code

Development of Remote Monitoring System for groundwater purifier apparatus for community wells

마을 공동 우물용 지하수 정수 장치의 원격 모니터링 시스템 개발

  • Kim, Dong-Jin (Department of Robotics and Automation Engineering, Hoseo university) ;
  • park, Sang-heup (Division of Mechanical Engineering, Kongju University) ;
  • Lee, Hong-Sup (Division of Mechanical Engineering, Kongju University)
  • 김동진 (호서대학교 로봇자동화공학과) ;
  • 박상흡 (공주대학교 기계공학과) ;
  • 이홍섭 (공주대학교 기계공학과)
  • Received : 2019.09.09
  • Accepted : 2019.11.01
  • Published : 2019.11.30

Abstract

Recently, the pollution of groundwater has become serious. In particular, the contamination of groundwater near livestock farms is becoming increasingly severe and it is difficult to drink with drinking water. In this paper, a groundwater purifier apparatus that can be installed in a community well was designed. The designed groundwater purifier apparatus enables a RO membrane filter and UV sterilization to remove pollutants, such as heavy metals, bacteria, and organic compounds. In addition, electrical conductivity, pressure, and flow sensors were added for remote monitoring. Remote monitoring of the system can determine the level of fouling and contamination of RO membrane filters through pressure and flow sensor data, and can record changes in the contamination and condition of groundwater through the electrical conductivity of the feed water. The designed groundwater purifier apparatus was installed at a farmhouse and remote monitoring. The result after 15 days of operating a groundwater purifier apparatus and analyzing the monitoring data revealed an average permeate water flow rate of 2.67L/min and an average water pressure of 7.09kgf/㎠, indicating that the RO Membrane filtered without fouling and clogging. The average electrical conductivity was 796.6 S/㎠ of the feed water and 55.6 S/㎠ of permeate water, which is similar to that of general tap water. Through this, it was confirmed that no pollutant occurred in the surroundings. Therefore, the designed groundwater purifier apparatus can confirm the replacement time of the RO membrane filter in advance through remote monitoring, and check the pollution state of the groundwater.

최근 지하수의 오염이 심각해지고 있다. 특히 축산농가 근처의 지하수 오염은 더욱 심해지고 있으며, 음용수로 마시기 어렵다. 그러나 일부 지역에서는 오염된 것을 알면서도 마시고 있다. 본 논문에서는 마을 공동우물에 설치할 수 있는 지하수 정수 장치를 설계 하였다. 설계된 지하수 정수 장치는 RO 멤브레인 필터를 사용하고, UV 살균을 통해 중금속, 박테리아, 유기화합물 등의 오염물질을 제거할 수 있게 하였다. 또한 원격 모니터링을 위해 전기 전도도, 압력, 유량 등의 센서를 부가하였다. 원격으로 모니터링하는 압력 및 유량 데이터로 RO 멤브레인 필터의 파울링 및 오염의 여부를 판단할 수 있으며, 급수의 전기전도도를 통해 유입되는 지하수의 오염 및 상태의 변동을 파악할 수 있다. 본 논문에서 설계된 지하수 정수 장치를 시골 농가에 설치하여 원격 모니터링 하였다. 15일간 지하수 정수 장치를 운영하고 모니터링 데이터를 분석한 결과, 생산수 유량은 평균 2.67L/min이고 급수의 압력 평균 7.09kgf/㎠로 RO 멤브레인 필터가 파울링 및 막힘없이 필터링되고 있음을 파악할 수 있었다. 또한 평균 전기전도도는 급수 796.6 uS/㎠이고 생산수 55.6uS/㎠로 일반적인 수돗물과 유사한 값을 나타내고 있어 주변에 오염원이 발생하지 않았음을 확인 할 수 있었다. 따라서 설계된 지하수 정수 장치는 원격 모니터링을 통해 필터의 교체 시점을 미리 확인할 수 있고, 지하수의 오염 여부에 대한 상태 확인이 가능하다.

Keywords

References

  1. K-water, Water and Future, pp. 10-11, 159, 2019.
  2. Ji-Hye Yoon, Problems and Improvement of Ground -water Management, Master's thesis, Ajou University, pp. 44-60, 2017.
  3. Joung-Ku Park, Rak-Hyeon Kim, Jin-Yong Lee, Dong -Hyuk Choi, Tae-Dong Kim, "Evaluation of status of Groundwater Quality Monitoring Network of Korea : Implications for Improvement", Journal of Soil and Groundwater Environment, Vol. 12, No. 6, pp. 92-99, 2007.
  4. Mok Young Lee, Sung Woo Lee, Bang Ryun Hur, Guidebook of Standard for Water purification, National Institute of Environment Research, pp. 220, 2013.
  5. Garyoung Lee, Min Kyeong Choi, Chaeeun Shim, Hyunha Shin, Jisoo Lee, Jun Seok Hwang, "Procedure for Implementing Water Supply System: Case of Rainwater and Groundwater Utilization", Journal of Appropriate Technology, Vol. 4, No. 2, pp. 108-119, 2018.
  6. Ministry of Environment, Integrated work instructions on water quality conservation of groundwater, Soil and Groundwater Division(MOE), Korea, pp. 32-33, 311-315, 332-339.
  7. Murat Eyvaz, Serkan Arslan, Ercan Gurbulak, Ebubekir Yuksel, "Textile Materials in Liquid Filtration Practices : Current Status and Perspectives in Water and Wastewater Treatment", pp. 297, IntechOpen, 2017. DOI: https://dx.doi.org/10.5772/intechopen.69462
  8. Kyung-chul Yang, Kyung-soo Chun, Duk-Soo Lee, Jae-Keun Ryu, "Physicochemical Characteristic of Drinking Water in The Longevity Villages", Environmental Monitoring and Assessment, Vol. 11, No. 3, pp. 119-128, 2004.
  9. Ministry of Environment, Manual of action when pollution enters in intake and water purification plant, Korea, pp. 35. 2009.
  10. Masaki Hayashi, "Temperature-Electrical Conductivity Relation of Water for Environmental Monitoring and Geophysical Data Inversion", Journal of Korean Society for Environmental Analysis, Vol. 96, Iss. 1-3, pp. 189-195, 2008. DOI: https://doi.org/10.1023/B:EMAS.0000031719.83065.68
  11. N. R. G. Walton, "Electrical conductivity and Total Dissolved Solids -What is Their Precise Relationship?" Desalination, Vol. 72, pp. 275-292, 1985. https://doi.org/10.1016/0011-9164(89)80012-8
  12. Anna F Rusydi, "Correlation between conductivity and total dissolved solid in various type of water : A review" IOP Conference Series Earth and Environmental Science, Vol. 118, no. 1, pp. 1-6, 2018. DOI: https://doi.org/10.1088/1755-1315/118/1/012019
  13. Ali M. El-Nashar, "History and current Status of Membrane desalination Processes", Desalination And Water Resources Membrane Processes, Vol. 1, pp. 12-14, 34, 2010.