• Title/Summary/Keyword: 복합재보

Search Result 7, Processing Time 0.019 seconds

Vibration Analysis of Axially-Stressed Composite Beam with Viscoelastic Layer (점탄성층을 갖는 복합재보의 축하중 작용시 진동해석)

  • 이덕규
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.33-38
    • /
    • 2002
  • Dynamic analysis of laminated beams with a embedded damping layer under tension or compression axial load is investigated. Layer-Wise Zig-Zag Beam Theory and Interdependent Kinematic Relation using the governing equations of motion are incorporated to model the laminated beams with a damping layer and a corresponding beam zig-zag finite element is developed. Flexural frequencies and modal loss factors under tension or compression axial load are calculated based on Complex Eigenvalue Method. The effects of the axial tension and compression load on the frequencies and loss factors are discussed.

  • PDF

Development of the Low Power Stand-Alone Smoke and Heat Detector for the Reliability Improvement (신뢰성 개선을 위한 저전력 열연 복합식 단독경보형 감지기 개발)

  • Jee, Seung-Wook;Kim, Si-Kuk;Lee, Jae-Jin;Kim, Pil-Young;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.74-79
    • /
    • 2012
  • This study is described for development of the stand-alone smoke and heat detector (SASHD) according to the revised in 2011 type approval and performance inspection code for detector. The main improvement of the revised regulation is source. CMOS microcontroller with nano watt technology is use for development of the workable SASHD over 10 years. The low-power SASHD is developed by using the power-saving sleep mode of microcontroller, by making the low-power source voltage checker, heat detector and smoke detector. The stand-alone detector is developed by smoke and heat detector type for reduce false fire alarm. User can choose type of work between the heat detection mode and smoke & heat detection mode. The SASHD can communicate with each them using RS-485 communication supported from microcontroller. So, this study can develop the SASHD that is able to alarm more wide area when fire occurs and reduce a flash fire alarm.

Vibration Control of a Glass-Fiber Reinforced Termoplastic Composite Beam (유리섬유를 함유한 열가소성 복합재 보의 진동제어)

  • 권대규;윤여흥;이성철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.11-14
    • /
    • 2000
  • This paper presents the vibration control of a glass-fiber reinforced thermoplastic composite beam with a distributed PVDF sensor and piezo-ceramic achlator. The three types of different controllen which are PID, H$\infty$ , and p-synthesis ontrollcr are employed to achieve vibration suppression in the transient vibration of composite beam. In the H$\infty$ , controller design, 1st and 2nd natural frequencies are considered in the modeling, because robust control theory which has robustness to struchred uncertainty is adopled Lo suppress the vibration. If the controller designed by H$\infty$ , theory does not satisfy control performance, it is improved by $\mu$ -synthesis method with D-K iteration so that the$\mu$-contoller based on the structured singular value satisfies the nominal performance and robust performance Simulations and experiments were carried out with the designed controllers m order to demonstrate the suppression efficiency of each controller.

  • PDF

Thermal Vibration Characteristics of a Thin Walled Composite Beam attached on Spacecraft (위성체에 장착된 얇은 벽 복합재 보의 열 진동 특성)

  • Kim, Gyu-Sun;Song, O-Seop
    • Composites Research
    • /
    • v.23 no.6
    • /
    • pp.47-54
    • /
    • 2010
  • Thermal vibration characteristics of a thin walled composite beam attached on spacecraft are investigated in this paper. The composite beam is assumed to have a thin CUS(circumferentially uniform stiffness) wall and modeled with several composite materials which are already space qualified such as T300/Epoxy, YS90AEpoxy. Steady state angle and peak to peak error in spacecraft attitude angle and tip displacement of composite beams are evaluated as a performance index for thermal vibration characteristics. Evaluation results shows that composite beam made out of YS90A has nearly 2 times better than T300 in terms of peak to peak attitude error angle.

The Forced Vibration Control of a Flexible Beam using PZT Actuator (PZT 액튜에이터를 이용한 유연한 보의 강제 진동제어)

  • 윤여흥;임숙정;권대규;이성철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.275-278
    • /
    • 2001
  • Research on the forced vibration control of a flexible GFR composite beam using $\mu$-synthesis is performed on this paper. Modal analysis method and modal coordinates are introduced to obtain the state equations of the structural system. Using these equations, Robust control algorithm using $\mu$-synthesis is adopted to suppress the forced vibration of a flexible beam since the designed controller can considered plant uncertainty and external disturbance. Constant disturbance which is generated by shaking the flexible beam as I's natural frequency is effectively rejected by a PZT actuator. Simulations and experiments are carried out with the designed controller and effectiveness of forced vibration suppression strategy is verified by results.

  • PDF

A Study on Fire Alarm Test of IoT Multi-Fire Detector combined Smoke/CO and Smoke/Temperature Sensors (연기/CO 및 연기/열 복합형 IoT 멀티 화재 감지기의 화재감지실험 연구)

  • Son, Geun­Sik;So, Soo­Hyun
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.2
    • /
    • pp.236-244
    • /
    • 2021
  • Purpose: The purpose of this study is to develop IoT multi-fire detectors combined smoke/carbon monoxide/heat and wireless IoT communication and to confirm the detect performance by smoke generator fire test and cotton wicks fire test. Method: The IoT multi-fire detector combined smoke and CO and combined smoke and heat were experimented the detect performance by smoke generator test and fire test of cotton wicks. And the case of fire alarm was checked. Result: The IoT multi-fire detector combined smoke and CO rung the alarm at the fire test of cotton wicks, did not ring the alarm at the smoke generator test. In comparison, the IoT multi-fire detector combined smoke and heat did not ring the alarm both at the smoke generator test and the fire test of cotton wicks. Conclusion: The IoT multi-fire detector combined smoke and CO detected the only smoke including the carbon monoxide and the IoT multi-fire detector combined smoke and heat did not ring the alarm for lack of heat. As a result, when the developed IoT multi-fire detector was detected the signal more than the set point, the fire alarm was sounded through cotton wicks fire test and smoke generator.

Research on the Reliability Improvement of Automatic Fire Alarm System (자동화재탐지설비의 신뢰성 개선에 관한 연구)

  • Son, Young-Jin;Lee, Young-Il;Lee, Sang-Hyeon
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.42-49
    • /
    • 2008
  • This research is to provide a scheme for an automatic fire alarm system with higher reliability through solving problems of malfunctioning (false or missing fire alarm) and power interruption (result from frequently unwanted activation, etc) of an automatic fire alarm system. A digital control system with microprocessor-based is proposed to reduce the possibility of malfunctioning through a combinational use of heat, smoke and CO sensors. Higher reliability could be achieved by these multiple sensors based fire detection system and fire distinction algorithm. In this research, we implemented actual fire detection system and conducted fire test to verify improvement on reliability.