• Title/Summary/Keyword: 복합발전소

Search Result 177, Processing Time 0.037 seconds

Investigation of the High Cycle Fatigue Crack of the Gas Turbine Compressor Blade Using Finite Element Analysis (유한요소해석을 이용한 가스터빈 압축기 블레이드 피로균열 해석)

  • Yun, Wan-No;Kim, Jun-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.12
    • /
    • pp.107-112
    • /
    • 2010
  • A gas turbine consists of an upstream compressor and a downstream turbine with a combustion chamber, and also the compressor and the turbine are generally coupled using a single shaft. Large scale gas turbine compressor is designed as multi-stage axial flow and the blade is fan-type which is thick and wide. Recently radial cracking happens occasionally at the compressor blade tip of large scale gas turbine. So, FEM was performed on the compressor blade and vibration modes and dynamic stresses were analyzed. According to the analysis, 9th natural frequency mode of the blade, which is 2 strip mode, is near the vane passing frequency by the vane located at the upstream of the blade.

Optimum Design of a Heat Recovery Steam generator(I) (열회수 증기발생기의 최적설계에 대한 연구(I))

  • 신지영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.5
    • /
    • pp.670-678
    • /
    • 1999
  • Heat recovery steam generator(HRSG) is a principal component of the combined cycle power plant (CCPP) which utilizes the waste energy of the gas turbine exhaust gas. A design of the HRSG is a keypoint to achieve high cycle efficiency with competitive cost. This paper presents a brief review on the design of a HRSG which covers the basic design parameters and their effects on the performance and the investment cost. Finally the concept of the optimum design point is presented according to the selection of a pinch point temperature difference and a steam pressure as an illustrated case.

  • PDF

Field test Results for PSS Parameter Tuning in Seo-Incheon Power Plant (서인천 복합화력 발전소의 PSS 파라메터 Tuning)

  • Shin, Jeong-Hoon;Kim, Tae-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1143-1146
    • /
    • 1998
  • Static excitation systems with high gain and fast response times greatly aid transient stability. but at the same time tend to reduce small signal stability. The objective of the power system stabilizer(PSS) control is to provide a positive contribution to damping of the generator rotor angle swings, which are in a broad range of frequencies in the power system. Therefore, this paper shows the field test results for the GE's EX2000 PSS tuning on units at Seo-Incheon power plant. The test is to verify that the PSS response meets GE's design, criteria. The responses of generator terminal voltage, active power, field voltage and current were analyzed and PSS gain was tuned by 10 finally.

  • PDF

Comparison and Evaluation of Chloride Penetration Resistance in Nuclear Power Plant Concrete with Different Water-to-Cement Ratios (물시멘트비가 다른 원전 콘크리트의 염화물 침투저항성 비교평가)

  • Son, Jeong Jin;Kim, Ji-Hyun;Chung, Chul-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.315-316
    • /
    • 2023
  • In the present investigation, the chloride ion penetration resistance of nuclear power plant concrete with varying water-to-cement ratios was assessed. A comparative analysis was conducted on concretes that do not incorporate supplementary cementitious materials, such as fly ash, using permanently decommissioned nuclear structures as a reference. The objective is to employ this acquired data as a fundamental resource for the evaluation of the residual service life of nuclear power plant structures in subsequent studies.

  • PDF

Gesture Recognition Using Stereo Tracking Initiator and HMM for Tele-Operation (스테레오 영상 추적 자동초기화와 HMM을 이용한 원격 작업용 제스처 인식)

  • Jeong, Ji-Won;Lee, Yong-Beom;Jin, Seong-Il
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.8
    • /
    • pp.2262-2270
    • /
    • 1999
  • In this paper, we describe gesture recognition algorithm using computer vision sensor and HMM. The automatic hand region extraction has been proposed for initializing the tracking of the tele-operation gestures. For this, distance informations(disparity map) as results of stereo matching of initial left and right images are employed to isolate the hand region from a scene. PDOE(positive difference of edges) feature images adapted here have been found to be robust against noise and background brightness. The KNU/KAERI(K/K) gesture instruction set is defined for tele-operation in atomic electric power stations. The composite recognition model constructed by concatenating three gesture instruction models including pre-orders, basic orders, and post-orders has been proposed and identified by discrete HMM. Our experimental results showed that consecutive orders composed of more than two ones are correctly recognized at the rate of above 97%.

  • PDF

Change of Ammonia Consumption with Gas Turbine Output in DeNOx System for a 580 MW Combined Cycle Power Plant (580 MW급 복합발전소 탈질설비에서 가스터빈 출력에 따른 암모니아 소모량 변화)

  • Jang, Yong-Woo;Yoo, Ho-Seon
    • Plant Journal
    • /
    • v.15 no.3
    • /
    • pp.23-28
    • /
    • 2019
  • In this study, ammonia consumption by gas turbine output was adjusted to find out the amount of ammonia consumption that complies with the enhanced Air Quality Preservation Act and internal regulation emission standards in SCR type DeNOx System for a 580 MW Sejong Combined Cycle Power Plant. For measurements, the gas turbine output was varied to 50, 99, 149, 198 MW and ammonia consumption was adjusted with the combustion gas and ammonia supply conditions fixed at each stage. When the emission limit were change from 10 ppm to 8 ppm, ammonia consumption was increased from 78, 93, 105, 133 kg/h to 89, 113, 132, 176 kg/h. The increase rate of ammonia consumption was 14, 22, 26, 32% per output category compared to the 10 ppm emission limit, which was shown to increase as output increased.

Study on the Free CaO Analysis of Coal Ash in the Domestic Circulating Fluidized Bed Combustion using ethylene glycol method (에틸렌글리콜법을 활용한 국내 순환유동층보일러 석탄회의 Free CaO 평가 연구)

  • Seo, Jun-Hyung;Baek, Chul-Seoung;Kim, Young-Jin;Choi, Moon-Kwan;Cho, Kye-Hong;Ahn, Ji-Whan
    • Journal of Energy Engineering
    • /
    • v.26 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • This study was carried out to physicochemical properties and free CaO contents of coal ash in domestic circulating fludized bed combustion power plant using ethylene glycol method. Results of physicochemical properties, there are many differences in CaO contents for the region position in CFBC plant. The reason, It is considered to be reflected that regulation of exhaust concentration for oxides of sulfur and other operation characteristics of region position in CFBC plant. Free CaO contents are 1.96 ~ 10.78% of fly ash and 0.07~4.24 % of bottom ash, fly ash is higher than in the bottom ash. besides CaO contents of raw materials, particle distribution have a lot of influence Free CaO contents.

Seismic Fragility Analysis of Multi-Modes Structures Considering Modal Contribution Factor (모드기여도를 고려한 복수모드구조물의 지진취약도분석)

  • 조양희;조성국
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.4
    • /
    • pp.15-22
    • /
    • 2002
  • In the course of seismic probabilistic risk assessment(SPRA), seismic fragility analysis(SFA) is utilized as a tool to evaluate the actual seismic capacity of structures. This paper introduces a methodology of SFA and its evaluation procedures, especially focusing on the basic fragility variables. A new definition of the response spectrum shape factor as one of the most critical basic variables is suggested. The new factor is expressed as a term of linear algebraic sum using the modal contribution factor. The efficiency of new response spectrum shape factor is evaluated and validated to use in practice through the case study of the nuclear power plant structures. The case study results show that the proposed method can be effectively applicable to multi-mode structures with composite modal damping.

A Study on Partial Load Performance of Absorption Type Heat Pump for Waste Heat Recovery of Closed Cooling Water (기기냉각수 폐열회수용 흡수식 히트펌프의 부분부하 성능에 관한 연구)

  • Park, Byungchul;Kim, Taehyeong;Kim, Kwangsu
    • Journal of Energy Engineering
    • /
    • v.28 no.2
    • /
    • pp.47-54
    • /
    • 2019
  • As absorption type heat pump for waste heat recovery is installed in combined cycle power plant for Energy Service Company, performance test is implemented to confirm the operation data on partial load. The operation data changes according to the heat pump operation on partial load are as follows. Total heat output increases, because waste heat of closed cooling water and a portion of LP steam from HRSG is supplied. But electric power output of steam turbine is reduced, because LP steam to steam turbine is reduced. And heat output from HP district heater and LP district heater is reduced, because HP turbine exhaust steam to HP district heater and LP district heater is reduced. On partial load operation, turbine output reduction is higher than the base load operation. Therefore, on partial load, heat pump should be operated in consideration of the heat output increase and electric power output reduction.

A Study on Comparative Analysis of Socio-economic Impact Assessment Methods on Climate Change and Necessity of Application for Water Management (기후변화 대응을 위한 발전소 온배수 활용 양식업 경제성 분석)

  • Lee, Sangsin;Kim, Shang Moon;Um, Gi Jeung
    • Journal of Korean Society of societal Security
    • /
    • v.4 no.2
    • /
    • pp.73-78
    • /
    • 2011
  • In order to resolve the problem of change in global climate which is worsening as days go by and to preemptively cope with strengthened restriction on carbon emission, the government enacted 'Framework Act on Low Carbon Green Growth' in 2010 and selected green technology and green industry as new national growth engines. For this reason, the necessity to use the un-utilized waste heat across the whole industrial system has become an issue, and studies on and applications of recycling in the agricultural and fishery fields such as cultivation of tropical crops and flatfishes by utilizing the waste heat and thermal effluent generated by large industrial complexes including power plants are being actively carried out. In this study, we looked into the domestic and overseas examples of having utilized waste heat abandoned in the form of power plant thermal effluent, and carried out economic efficiency evaluation of sturgeon aquaculture utilizing thermal effluent of Yeongwol LNG Combined Cycle Power Plant in Gangwon-do. In this analysis, we analyzed the economic efficiency of a model business plan divided into three steps, starting from a small scale in order to minimize the investment risk and financial burden, which is then gradually expanded. The business operation period was assumed to be 10 years (2012~2021), and the NVP (Net Present Value) and economic efficiency (B/C) for the operation period (10 years) were estimated for different loan size by dividing the size of external loan by stage into 80% and 40% based on the basic statistics secured through a site survey. Through the result of analysis, we can see that reducing the size of the external loan is an important factor in securing greater economic efficiency as, while the B/C is 1.79 in the case the external loan is 80% of the total investment, it is presumed to be improved to 1.81 when the loan is 40%. As the findings of this study showed that the economic efficiency of sturgeon aquaculture utilizing thermal effluent of power plant can be secured, it is presumed that regional development project items with high added value can be derived though this, and, in addition, this study will greatly contribute to reinforcement of the capability of local governments to cope with climate change.

  • PDF