• 제목/요약/키워드: 복합단열

검색결과 128건 처리시간 0.026초

반대방향의 방향각을 갖는 2열 분사구조의 막냉각 특성(I) -배열의 영향- (Film Cooling from Two Rows of Holes with Opposite Orientation Angles(I) -Configuration Effect-)

  • 안준;정인성;이준식
    • 대한기계학회논문집B
    • /
    • 제25권8호
    • /
    • pp.1122-1130
    • /
    • 2001
  • Film cooling performance from two rows of holes with opposite orientation angles is evaluated in terms of heat flux ratio. The film cooling hole has a fixed inclination angle of 35°and orientation angle of 45°for the downstream row and -45°for the upstream row. Four film cooling hole arrangements including inline and staggered configurations are investigated. The blowing ratio studied was 1.0. Boundary layer temperature distributions are measured to investigate injectant behaviors and mixing characteristics. Detailed distributions of the adiabatic film cooling effectiveness and the heat transfer coefficient are measured using TLC(Thermochromic Liquid Crystal). For the inline configuration, there forms a downwash flow at the downstream hole exit to make the injectant well attach to the wall, which gives high adiabatic film cooling effectiveness and heat transfer coefficient. The evaluation of heat flux ratio shows that the inline configuration gives better film cooling performance with the help of the downwash flow at the downstream hole exits.

반대방향의 방향각을 갖는 2열 분사구조의 막냉각 특성(II) -분사비의 영향- (Film Cooling from Two Rows of Holes with Opposite Orientation Angles(II) -Blowing Ratio Effect-)

  • 안준;정인성;이준식
    • 대한기계학회논문집B
    • /
    • 제25권8호
    • /
    • pp.1131-1139
    • /
    • 2001
  • Experimental results are presented, which describe the effect of blowing ratio on film cooling from two rows of holes with opposite orientation angles. The inclination angle is fixed at 35°, and the orientation angles are set to be 45°for the downstream row, and -45°for the upstream row. The studied blowing ratios are 0.5, 1.0 and 2.0. The boundary layer temperature distributions are measured using thermocouple at two downstream locations. Detailed adiabatic film cooling effectiveness and heat transfer coefficient distributions are measured with TLC(Thermochromic Liquid Crystal). The adiabatic film cooling effectiveness and heat transfer coefficient distributions are discussed in connection with the injectant behaviors inferred from the boundary layer temperature distributions. Film cooling performance, represented by heat flux is evaluated from the adiabatic film cooling effectiveness and heat transfer coefficient data. The results show that the investigated geometry provides improved film cooling performance at the high blowing ratios of 1.0 and 2.0.

반대방향의 방향각을 갖는 2열 분사구조의 막냉각 특성 : 분사비의 영향 (Film Cooling from Two Rows of Holes with Opposite Orientation Angles: Blowing Ratio Effects)

  • 안준;정인성;이준식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.113-118
    • /
    • 2000
  • Experimental results describing the effects of blowing ratio on film cooling from two rows of holes with opposite orientation angles are presented. The inclination angle was fixed at $35^{\circ}$ and the orientation angles were set to be $45^{\circ}$ for downstream row. and $-45^{\circ}$ for upsream row. The studied blowing ratios were 0.5, 1.0 and 2.0. The boundary layer temperature distributions were measured using thermocouple at two downstream loundary layer temperature distributions were measured using thermocouple at two downstream locations. Detailed adiabatic film cooling effectiveness and heat transfer coefficient distributions were measured with TLC(Thermochromic Liquid Crystal). The adiabatic film cooling effectiveness and heat transfer coefficient distributions are discussed in connection with the injectant behaviors inferred from the boundary layer temperature distributions. Film cooling performance, represented by heat flux was calculated with the adiabatic film cooling effectiveness and heat transfer coefficient data.

  • PDF

건축용 외장재의 발연특성에 관한 연구 (A Study on Characteristics of Smoke Release for Architectural Surface Material)

  • 박영주;이해평;황미정;양영숙;유재열;이미리
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 추계학술논문발표회 논문집
    • /
    • pp.486-489
    • /
    • 2011
  • 건축물 내 외벽에 주로 사용되는 건축용 자재 중 샌드위치 패널은 양면으로 도장한 철판 사이에 심재로 단열재를 넣어 구성된 합성복합자재이다. 샌드위치 패널의 사용범위는 창고시설 및 공업용 건축 등의 용도로 많이 사용되고 있으며, 최근에는 시공에 따른 이점으로 주택 및 상업용등으로 널리 확대되어 사용되고 있다. 본 연구에서는 화재초기의 연기밀도는 인명 대피 시 시야확보에 있어 중요한 역할을 하기에 현재 국내에서 사용되는 건축용 외장재를 용도별로 선정하여 시간에 따른 연기밀도의 값을 구하고 용도에 따른 화재 연기의 확산 정도를 예측하는데 목적을 두었다.

  • PDF

대전지역의 건물별 에너지 소비패턴에 대한 실태조사 (Energy Consumption Patterns for Various Building Types in Taejon)

  • 김병선;김윤덕
    • 태양에너지
    • /
    • 제18권3호
    • /
    • pp.41-50
    • /
    • 1998
  • 일반적으로 최종적인 건물 설계에 의한 건물의 에너지 성능은 거주후평가(POE)에 의해 이루어지게 되며, 축적된 평가 결과는 설계에 의한 시행착오를 예측하기 위한 새로운 설계의 Feedback 자료로 이용되어져야 한다. 그러나 이러한 기존 건물의 에너지 평가자료가 구체적으로 편집되어 제시되어 있지 못한 현 실정에서 본 조사는 설계시에 에너지 성능을 비교할 수 있는 척도를 제공해 줄 수 있을 것이며, 추후 건물 에너지 성능규제를 위한 기초 자료가 될 수 있을 것이다. 이에 대전 및 인근지역 35개 공공건물의 건물에너지소비의 패턴이 조사되었으며, 우선 전화국, 백화점, 병원, 연구소, 스포츠센터 수영장, 전시관, 대학교, 호텔의 8개 건물로 분류하였다. 그러나 많은 수의 공공건물은 여러 가지 복합적인 기능을 갖추고 있고 따라서, 건물의 이름만으로 건물의 에너지소비패턴을 분석하기 위하여 (1) 준공연도, (2) 층수, (3) 단열정도, (4) 주연료, (5) 난방면적, (6) 연간난방일수, (7) 평균난방실내온도, (8) 냉방면적, (9) 평균냉방실내온도, (10) 보일러형식, (11) 보일러대수, (12) 보일러용량, (13) 보일러연료사용량, (14) 전기사용량, (15) 최대부하등이 조사되었다.

  • PDF

굵은 입자 시멘트 및 플라이애시를 복합 사용한 콘크리트의 Mock-up Test (Mock-up Test of Concrete using Combined Coarse particle Cement and Fly-Ash)

  • 이충섭;이재윤;장덕배;김영필;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 학계
    • /
    • pp.87-91
    • /
    • 2009
  • This study investigates possibility for practical use through small sized test with OPC and substituted fly ash 10% and return coarse cement (RCC), classed 1100${\sim}$1200 cm2/g, which is made by Cyclone Separator at cement producing process 20% (CF) for OPC. The experimental factors are 48% of W/B and OPC and 2 kinds of concrete proportions. The target slump and air content are $150{\pm}25$ mm and $4.5{\pm}1.5$ %. For the results, the flowalility and air content of CF are less than OPC because it needs more superplasticiser and air-entraining agent. The temperature history of CF is lower than OPC about $6{\sim}10^{\circ}C$. For the strength properties, CF is less than OPC, but their gap is declined at 28 days. The strength of the specimens are ordered by standard curing, field cured specimens, and core specimens.

  • PDF

모델 가스터빈 연소기에서 합성가스 연소성능시험 - Part 2 : NOx/CO 배출특성, 온도특성, 화염구조 (Combustion Performance Test of Syngas Gas in a Model Gas Turbine Combustor - Part 2 : NOx/CO emission Characteristics, Temperature Characteristics and Flame Structures)

  • 이민철;윤지수;주성필;윤영빈
    • 한국항공우주학회지
    • /
    • 제41권8호
    • /
    • pp.639-648
    • /
    • 2013
  • 본 논문은 부게넘 및 태안 IGCC플랜트의 연료를 대상으로 석탄으로부터 생성된 합성가스의 NOx/CO배출 특성, 온도특성, 화염의 구조에 대해 기술하였다. GE7EA 모사 가스터빈 연소기를 대상으로 상압 고온 연소시험을 수행하여 입열량 및 질소희석에 따른 연소특성을 관찰하였다. 입열량이 감소하고, 희석제량이 증가할 때 단열화염온도의 감소로 NOx가 감소하였고, 저부하에서는 희석량이 증가할수록 불완전 연소로 인해 CO가 증가하였다. 이러한 NOx 감소 및 CO발생은 각각 $1500^{\circ}C$$1250^{\circ}C$의 특정 화염온도에서 관찰되었다. 또한 질소 희석이 증가할수록 단열화염온도 및 연소기 라이너의 온도가 감소했고, 화염 부상과 같은 화염구조의 변화로 인해 특이점이 관찰되었다. 본 연구결과를 통해 질소희석이 NOx/CO배출 및 온도, 화염구조에 미치는 영향이 검토되었으며, 시험 데이터는 향후 태안 IGCC 플랜트의 운전시 최적 조건 선정을 위한 기초자료로 활용될 예정이다.

충북 증평 지질학습장 시험부지에 대한 물리탐사 및 지질공학 자료의 해석 (Interpretation of Geophysical and Engineering Geology Data from a Test Site for Geological Field Trip in Jeungpyung, Chungbuk)

  • 김관수;윤현석;사진현;서용석;김지수
    • 지질공학
    • /
    • 제26권3호
    • /
    • pp.339-352
    • /
    • 2016
  • 지하 매질의 물리적인 성질을 정확히 평가하기 위한 가장 일반적인 방법은 해당 지점에서 시추하여 채취한 암편을 대상으로 해석한 지질공학적인 실내시험 결과와 시추공 안에 삽입한 탐사 기구를 통해 얻은 지구물리학적인 자료를 함께 복합적으로 해석하는 것이다. 이 연구에서는 충북 증평의 지질학습장으로 예정된 시험부지 중의 한 곳에서 시추공 탐사 대신 수집한 지표 탄성파탐사(굴절법 및 표면파법) 자료로부터 얻은 P파 및 S파 속도구조와 이를 토대로 작성된 포아송 비 단면을 통해 노두에 좁은 폭으로 드러난 암석 환경(적색퇴적암, 회색화산암, 풍화 화산암) 및 접촉선에서 관찰된 단열, 파쇄대가 확인되는지 알아보았다. 또한 탐사 지역에 주로 분포하는 회색 화산암과 적색 퇴적암을 대상으로 지표지질 조사와 실내 지질공학 실험을 수행하였다. 탐사자료에서 평가된 동적 탄성계수 영률은 지질공학 자료의 정적 탄성계수보다 높았다. 실내 시험에서 회색화산암에 비해 공극률이 작고 함수비가 작은 것으로 평가된 적색퇴적암은 추가적으로 건기와 우기에 실시한 전기탐사(비저항 및 자연전위) 결과에서 건우기와 관계없이 상대적으로 전기비저항이 높고 그 변화 폭이 매우 작은 영역으로 확인되었다. 특히 높은 함수비와 공극률을 갖는 풍화된 회색 화산암과 함께 접촉선에서 좁게 발달한 단열 파쇄대가 우기 때의 충전율을 높이는 열린 통로의 역할을 한 것으로 해석된다.

간척지에서 재배된 양마(Kenaf)의 해부학적 특성(I)-사부와 목부의 생장기관과 높이에 따른 차이- (Anatomical Characteristics of Kenaf Grown in Reclaimed Land(I)-Differences in Phloem and Xylem with Growth Period and Height-)

  • 이선화;이세나;권성민;이명구;조동하;김남훈
    • Journal of the Korean Wood Science and Technology
    • /
    • 제35권6호
    • /
    • pp.43-49
    • /
    • 2007
  • 국내 간척지에서 생장한 양마(kenaf)의 생장기관과 높이에 따른 해부학적 특성을 광학현미경과 주사전자현미경(SEM)을 사용하여 관찰하였다. 2006년 5월에 파종한 케나프를 동년 7, 8, 9,10월 총 4회에 걸쳐 채취하고, 각 생장기간 별로 3, 35, 70, 105 cm의 높이에서 시료를 채취하여 실험을 실시하였다. 사부에는 인피섬유, 방사조직, 사관이 존재하였고 목부에는 도관, 목섬유, 방사조직과 수가 존재하였다. 목질부의 도관은 산재상으로 고립관공과 방사복합관공이 혼재하였고 도관상호간벽공은 교호상 벽공의 형태가 관찰되었다. 또한 목부의 방사조직은 단열, 복열 및 다열방사조직이 혼재하였고 방사유세포의 형태는 직립, 평복, 방형세포가 모두 존재하였다. 생장기간이 길어질수록 사부와 목부가 증가하였고 수심부가 감소하였으며, 인피섬유의 층수와 사부방사조직이 증가하였다. 그리고 사부에 있어서 형성층부위에 가까운 인피섬유의 층이 외층부의 인피섬유의 층보다 더 크고 세포수가 많았다. 또한 생장기간이 길어질수록 접선단면에서 다열방사조직이 많이 관찰되었다. 생장 높이가 높아질수록 사부가 증가하였고 목부가 감소하였으며, 인피섬유의 층수와 사부방사조직이 감소하였다. 그리고 생장높이가 높아질수록 접선단면에서 단열방사조직이 많이 관찰되었다.

굵은입자 시멘트와 광물질 혼화재를 조합 사용하는 콘크리트의 기초적 특성 (A Fundamental Properties of the Concrete Using Coarse Particle Cement and Mineral Admixture)

  • 한천구;장덕배
    • 한국건설순환자원학회논문집
    • /
    • 제5권1호
    • /
    • pp.131-138
    • /
    • 2010
  • 본 연구에서는 보통포틀랜드 시멘트(이하 OPC)제조과정의 분쇄공정 중 밀출구에서 배출되는 비교적 가격이 저렴하면서, 수화열면으로도 효과일 것으로 예상되는 입자분포를 갖는 시멘트(이하 CC)를 대상으로 플라이애시(이하 FA)와 고로슬래그 미분말(이하 BS)를 복합치환하는 3성분계 저발열 시멘트로의 개발 가능성을 검토하기 위하여 유동성, 강도, 간이단열온도 상승량 등 기초적인 특성에 대하여 분석하고자 한다. 실험결과로 유동성은 CC의 치환율이 증가함에 따라 저하하는 경향을 보였고, FA+BS의 치환율이 늘어남에 따라 증가하는 경향을 나타냈다. 공기량은 CC의 치환율이 증가함에 따라 미소하게 감소하는 경향을 나타냈고, FA+BS의 치환율이 증가함에 따라 감소하였다. 응결특성으로 CC 및 FA+BS의 치환율이 증가 할수록 응결 시간은 지연되었다. 간이 단열에 의한 온도 상승량은 전반적으로 CC 치환율이 증가할수록, FA+BS의 치환율이 증가할수록 피크온도는 감소하였고, 이후 온도저하가 완만해 지는 경향을 나타냈다. 압축강도는 CC 및 FA+BS 치환율이 증가할수록 저하하였는데, 재령이 경과함에 따라 장기강도는 Plain과 동등하거나 동등 이상의 강도를 발현 하였다. 종합적으로 CC에 FA+BS를 치환하였을 때 유동성 및 공기량은 저하하는 경향을 나타냈으나, 수화열 면에서 양호한 저감효과를 보여 3성분계 저발열 시멘트로의 개발이 가능성할 것으로 사료된다.

  • PDF