Evaluation the Impact of Installing a Isolation Valve on Condensate System of Nuclear Power Plan (원자력발전소 복수기 수실 차단밸브 설치 영향 평가)

  • Lee, Sun-Ki
    • Journal of Industrial Convergence
    • /
    • v.18 no.4
    • /
    • pp.15-21
    • /
    • 2020
  • Because there are no isolation valves in condensate system of nuclear power plants, circulating water pump was shutdown for the condenser repair. When circulating water pump was shutdown, power plant output decreased about 45%. These output decreasing can minimize by establishing isolation valves. In this paper, evaluated effect to flow conditions change of condensate system, structural integrity of system, condenser pressure of in case of establish isolation valves to condensate system. Results of the evaluation, the flow rate due to the installation of the isolation valve decreased 0.3% when the valve was fully opened and 4.5% when fully closed. In addition, it was found that the vacuum degree of the condenser decreased with decreasing flow rate, but the integrity of the system was maintained.

Mechanical Behavior of Anchorage Zones in Prestressed Concrete Members with Single and Closely-Spaced Anchorages (단일텐던 및 복수텐던이 설치된 프리스트레스트 콘크리트 부재의 정착부 거동 연구)

  • Oh, Byung Hwan;Lim, Dong Hwan;Yoo, Seung Woon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.6
    • /
    • pp.1329-1339
    • /
    • 1994
  • The purpose of present study is to explore the mechanical behavior of anchorage zones in prestressed concrete members with single and closely-spaced multiple tendon anchorages. The cracking loads and local stress distributions at these anchorage zones are studied. To this end, a series of experiments have been conducted. From this study, it is found that the failure of anchorage zones of the closely-spaced multiple tendon members is initiated by cracking along the tendon path and that the tensile stresses arising in the vicinity of anchorage zone of the first tendon are reduced due to additional compression of the second tendon. This results in the increase of cracking capacity of the member. The effects of multiple tendons are presented in the form of strain distribution and cracking load comparisons.

  • PDF

An Analysis of Runoff reduction Amounts for the Detention Pond in Trunk Sewer (간선저류지 설치위치에 따른 우수유출저감효과 분석)

  • Lee, Sung Ho;Lee, Jae Joon;Yoon, Sei Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.556-556
    • /
    • 2016
  • 도시화 및 산업화에 따른 유출량의 증가 및 도달시간의 감소로 인해 도시지역의 침수피해가 빈번하게 발생되고 있는 실정이다. 내수침수피해 방지를 위해 유역내 우수관거 용량향상 및 우수유 출저감시설의 설치 등과 같은 유역전반의 홍수방어 체계를 구축하고자 하는 노력들이 이루어지고 있으나, 국내 대도시의 경우 저류시설 설치를 위한 부지 확보 및 우수관거 교체를 위한 예산확보가 어려운 실정이다. 따라서 도시화, 산업화, 인구집중으로 동일규모의 강우에서도 우수유출이 증대되고 있는 도시지역에서 원활한 내수배제를 위해 우수관거를 연계한 간선저류지 개념을 적용하여 우수유출저감효과를 분석할 필요가 있다. 본 연구에서는 간선저류지를 유역내의 임의의 위치에 설치하여 단일 저류지와 복수 저류지에 대해 각각 우수유출저감효과를 분석하였다. 간선저류지 설치로 인한 우수유출저감효과 분석을 위하여 단일 저류지의 면적은 $1,000m^3$, $2,000m^3$, $3,000m^3$ 등 3가지 크기로 설정하여 분석을 수행하였다. 단일 저류지의 위치에 따른 유출저감효과를 분석하기 위해 저류지의 위치는 전체 유역면적에 대한 저류지 상류부 면적의 비를 20%, 40%, 60%, 80%로 변화시키면서 분석을 수행하였으며, 복수 저류지의 경우 전체 유역면적에 대한 저류지 상류부 면적의 비를 다양하게 적용하여 분석을 수행하여, 단일 저류지 및 복수 저류지 설치 위치에 따른 도시유역의 우수유출저감효과를 분석하였다.

  • PDF

A Study on the Fouling Factor and the Formation of Surface Film in the Power Plant Condenser (발전소 복수기의 Fouling Factor 및 피막특성에 관한 연구)

  • Lee, Seung-Jin;Kim, Jang-Sun;Lee, Seong-Ho
    • Korean Journal of Materials Research
    • /
    • v.7 no.9
    • /
    • pp.750-757
    • /
    • 1997
  • 발전소 복수기의 열전달 표면에 형성되는 불순물의 fouling factor와 튜브내면에 부착되는 피막의 두께변화를 측정하여 복수기 관리에 관한 지침을 제시하고자 모델복수기를 이용하여 60일간 현장실험을 실시하였다. 복수기의 fouling factor는 시험 후 약 40일 이후부터 큰 폭으로 증가하였다. 발전용 복수기의 관청결도가 85-90%로 설계되므로 설계치를 유지하기 위해서는 약 40일 마다 복수기튜브를 세정하여 관청결도를 향상시켜야 할 것으로 판단되었다. 또한 동합금 재질을 사용하는 복수기튜브는 설치 후 보호피막이 형성되는 초기 30일 동안의 방식운전이 복수기튜브 건전성 확보에 중요한 인자임을 유추할 수 있었다.

  • PDF

A Study on the Behaviour of Smoke Spread Caused by Vehicle Fire in a Road Tunnel (터널 내 차량 화재에 따른 연기 확산 거동에 관한 연구)

  • Yoon, Yong-Kyun;Ju, Eun-Hye
    • Tunnel and Underground Space
    • /
    • v.22 no.5
    • /
    • pp.365-372
    • /
    • 2012
  • This paper aims to evaluate the effects that presence, installation number and capacity of ventilation vent and presence of multiple fire sources have on the behaviour of smoke temperature induced by vehicle fire in road tunnel. Six types of scenarios were assumed and FDS was ran to simulate them. As the number of ventilation vents increases, the smoke temperature are calculated to be reduced, but it is shown that effects exerted by two ventilation vents are almost similar to ones by three ventilation vents. Capacity of ventilation vent has a greater impact on the reduction of smoke temperature than installation number of ventilation vents. Smoke temperatures computed for all scenarios except for scenario No. 1 (without ventilation vent) and scenario No. 6 (with multiple fire sources) above fire source are analyzed to be under $400^{\circ}C$ and it means that the radiation of smoke layer above fire source doesn't induce the ignition of materials around fire source.

Actuator design and experimental verification on a high speed underwater vehicle (고속 수중운동체의 구동장치 설계 및 실험적 검증)

  • 곽동훈;양승윤;이동권;김창걸;서진희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.510-515
    • /
    • 1993
  • 본 연구에서는 저속에서도 시스템의 자세 제어가 용이하게 하기 위하여 추진기 뒤에 제어판이 위치하도록 설계하였으며, 일반 서보 시스템과는 달리 무게와 공간 제약이 크고, 제어판 운동에 따른 외란 등록성의 변화가 심하므로 push-pull 형태의 소형, 고출력 편로드 복동 복수 실린더의 작동기를 설계하였다. 또한 일반적으로 서보밸브와 작동기는 일체형으로 설계되나 본 시스템의 공간상 심한 제약으로 인하여 서보밸브와 작동기를 분리하는 방법으로 구조설계를 하고 그 사이 유로는 매니폴드식으로 하여 동력전달을 하였다. 설계된 구동장치를 실제 정밀제작하여 실험을 수행하였으며, 시뮬레이션 결과와 실험에 의하여 얻어진 결과를 비교 분석하여 설계의 타당성 및 시스템의 성능을 검증하였다. 고속 수중운동체에 대하여 저속에서 자세제어를 용이하게 하고, 제한된 좁은 설치공간의 문제점을 해결하기 위하여 1) 추진기 후미에 독립된 4개의 상, 하, 좌, 우 제어판 설치 2) 서보밸브는 몸체에, 작동기는 Tail Tube에 분리 작동 설계 3) 소형의 편로드 복동 복수 실린더로 설계 구성된 유압식 구동장치는 시뮬레이션과 실험 결과를 통하여 시스템의 타당성을 입증하였다. 그러므로, 개발한 구동장치는 저속에서도 큰 제어력으로 자세 제어가 용이하기 때문에 얕은 수심에서 발사시 예상되는 위험 요소를 상다ㅇ 개선 시키므로써 운용범위의 다양화를 가져 올것으로 기대된다.

  • PDF

A Research on Power Decoupled Quadruple-Active-Bridge Converter Adopting Multiple Transformers for DC Distribution System (다수의 변압기를 도입하여 포트 간 전력의 비동조화를 달성할 수 있는 DC 배전용 Quadruple-Active-Bridge 컨버터에 관한 연구)

  • Kim, Inhyeok;Lee, Jun-Young;Jung, Jee-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.139-141
    • /
    • 2020
  • 본 논문에선 다수의 변압기를 도입하여 복수의 입출력 포트 간 전력 동조화 문제를 해결할 수 있는 Quadruple-Active-Bridge(QAB) 컨버터를 제안한다. 기존 QAB 컨버터는 단일 변압기를 사용하기 때문에 입출력 포트 사이의 전력 동조화 문제가 발생한다. 따라서 단일 변압기에서 포트 간 전력 비동조화를 달성하기 위해 입력 포트의 누설 인덕턴스를 최소화하는 최적의 변압기 설계가 필요하나, 복수의 권선 구조로 인해 최적의 설계가 어렵다는 단점이 있다. 이러한 문제점을 해결하고자 본 논문에선 기존의 단일 변압기와 복수의 변압기를 함께 설치하는 구조를 제안한다. 제안한 구조를 통해 별도의 비동조화 알고리즘 없이 출력 포트 사이의 전력 동조화 문제를 해결할 수 있다. 그리고 변압기의 설계도 복잡했던 기존 QAB 와는 달리 쉬워지는 이점도 있다. 제안한 컨버터의 구조 및 전력 비동조화를 등가 모델을 통해 이론적으로 분석한다. 그리고 이를 검증하고자 3 kW급 시작품을 통해 전력전달 구조 및 전력 비동조화를 검증한다.

  • PDF

A Study on the Data Frame Length and Repetitive Transmission for IP Local Broadcasting (인터넷 지역 방송에서 데이터 프레임 길이와 복수 전송에 관한 연구)

  • Oh, Jong-Taek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.3
    • /
    • pp.123-126
    • /
    • 2011
  • As the number of users of smart phone and smart pad are increasing, the deployment of WiFi APs has been accelerated. Also Internet local broadcasting service will be activated near future. But transmission error is the critical problem, due to the one-way transmission of the data to the receivers. In this paper, FER is analysed according to BER and frame length, and repetitive transmission technique is proposed to reduce the effective FER.

Control Algorithm of Differential Power Processing Module for Power Generation from Photovoltaic Panels Including Multiple Strings (복수의 스트링을 가지는 PV 패널에 대응 가능한 차동 전력 조절기의 동작 알고리즘)

  • Kim, Geun-wook;Kim, Mina;Jung, Jee-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.10-12
    • /
    • 2020
  • 차동 전력 조절기 시스템은 PV 모듈의 부분 음영으로 인해 전체 발전량이 감소하는 현상을 방지하기 위해서 사용한다. 기존의 차동 전력 조절기는 PV 패널과 바이패스 다이오드를 연결하여 구성한 PV 스트링당 한 개의 전력변환 장치가 필요하므로, 전력변환 장치의 개수가 증가하고 전력 시스템의 설치비용이 증가한다. 본 논문에서는 복수의 스트링에 단일 전력변환장치를 사용할 수 있는 차동 전력 조절기 모듈의 구조와 동작 알고리즘을 제안한다. 차동 전력 조절기에 대한 동작 알고리즘을 통해 다양한 부분 음영 조건 시에도 기존의 직렬 연결방식이나 차동 전력 조절 방식에 비하여 최대 발전량을 유지할 수 있다. 제안하는 차동 전력 조절기의 동작 알고리즘은 Matlab/Simulink 시뮬레이션을 통해 성능을 검증하였다.