• Title/Summary/Keyword: 복사냉각

Search Result 135, Processing Time 0.027 seconds

A STUDY OF THERMAL ANALYSIS OF KAONICS (적외선 카메라 KAONICS의 열해석)

  • Kang, Ji-Na;Lee, Sung-Ho;Jin, Ho;Park, Soo-Jong;Moon, Bong-Kon;Kim, Sang-Ho;Park, Jang-Hyun
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.4
    • /
    • pp.467-480
    • /
    • 2004
  • It is very important to eliminate thermal background radiation for the near infrared camera system such as KAONICS (KAO Near Infrared Camera System). Thermal background radiations which come from window and cryostat wall influence IR detector and decrease IR system performance. Therefore the cold box which contains optics and detector housing must be cooled down to eliminate thermal background radiation. We carried out quantitative analysis to determine internal cooling temperature to reduce thermal noise in the J, H, Ks, and L bandpass. Additionally, we estimated the incoming heat load and then chose the cryocooler adequate to KAONICS's requirements. The cooling time and the final cooling temperature of the cold box were calculated. These results were also implemented to the system design.

Simulation of Radiative Property Effects on Radiant Cooling of Opaque Surface (비 투과면 복사 냉각에 대한 복사 물성의 영향 예측)

  • Byun, Ki-Hong
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.32-38
    • /
    • 2009
  • The effects of surface radiative properties on the radiant cooling of opaque surfaces under clear sky condition are studied. Two types of surfaces, one gray and the other selective, are compared. For the nighttime cooling, black surface gives the lowest plate temperature and on the other hand the ideal selective surface gives the highest temperature. The reverse is true when there is an insolation. Equivalent radiative heat transfer coefficient of radiant cooling without convection is about $1{\sim}7\;W/m^2-K$ for the range of values studied. The surface with black within the $6{\sim}13\;{\mu}m$ band else zero emissivity could be regarded as a black surface for the nighttime radiant cooling purposes. However, lower band limit of $4\;{\mu}m$ is preferred to $6\;{\mu}m$ for small insolation situations.

Radiant Cooling by the Plate Viewing the Daytime Sky (주간 하늘에 노출된 평판에 의한 복사냉각 실험)

  • Byun, Ki-Hong
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.11-17
    • /
    • 2007
  • The purpose of this study is to check whether the plate temperature could be lower than the surrounding air by using the radiant cooling during the day time in summer at Seoul. Without an insolation shield as this experiment was performed, a few cases were found. The temperatures of the black painted plate are lower than those of the aluminium film coated plate if the following condition exist; no or small insolation over the plate, the wind velocity less than around 2 m/s, and clear sky However if there are insolation over the plate, the temperatures of the aluminium coated plate are lower than the black painted plate. Also, as the wind velocity increases, the plate temperature decreases faster. The temperature response of the small system is much faster than the large system.

The Experimental Study of Radiant Cooling Test System under Different Covers (복사냉각 시스템에서 커버의 영향)

  • Byun, Ki-Hong;Smith, Theodore F.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.11
    • /
    • pp.797-802
    • /
    • 2007
  • The effects of window cover on the performance of the plate type radiant cooling test system are studied. The cover materials tested are 2mm, 1mm, 0.7mm glass, Cokin 007 filter, and PVC film. The measurements are performed during the September nights of 2005 at the rooftop of the building in Seoul. The equivalent height of the building is about a building with twelve floors. The radiant cooling performance of the black painted and aluminum film coated plate are compared under no cover condition. Also the results are compared when the system has cover over the plate. In general, the covers reduce the radiant cooling temperature differences during the nighttime. Among these covers, the PVC film cover shows the best performance. In some cases, the plate with PVC film cover shows lower temperatures than the system without cover.

Nocturnal Radiant Cooling during the Winter by the Plate Viewing the Sky (겨울 야간 하늘에 노출된 평판에 의한 복사냉각 실험)

  • Byun, Ki-Hong
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.5
    • /
    • pp.49-55
    • /
    • 2008
  • The radiant cooling(RC) effects are studied during the winter night. The plate was viewing the nighttime sky. The data were collected at the rooftop of the Engineering building at the Dongguk University in Seoul, Korea. As observed during the summer night, the plate temperature was lower than ambient temperature under the RC favorable conditions. The parameters under study are the wind velocity, cloud index, and visibility for given system size and surface condition. The results follow the same tendency with these parameters as observed from the previous study for the summer night. As long as the wind velocity is less than around 2 m/s, the radiant cooling was observed with the system under study. In some cases, the radiant cooling temperature differences (RCTD) are higher than those for the summer night. The larger the RCTD as the wind velocity decreases and as the sky becomes clear.

Nocturnal Radiant Cooling Experiment by a Plate Viewing the Sky (야간 하늘에 노출된 평판의 복사냉각 실험)

  • Byun Ki-Hong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.6
    • /
    • pp.605-610
    • /
    • 2005
  • The purpose of this experiment is to study the radiant cooling effects by a plate directly viewing the nighttime sky. The measurements are performed on a rooftop of the Engineering building at the Dongguk University in Seoul during the month of August in 2004. The radiant cooling effects are compared using three different types of plate sufaces, namely, galvanized iron, black painted, and aluminum film coated galvanized iron plate. Among these plates, the black Painted surface showed the lowest temperature that is lower than the ambient temperature. The maximum radiant cooling temperature difference, which is ambient temperature minus plate temperature, observed is about 5 K.

A Study on the Characteristics of Acid Dew in Western Pusan, Korea (부산 서부지역에서 산성이슬의 특성에 관한 연구)

  • 황용식;전병일;박문포;문덕환
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.269-270
    • /
    • 2003
  • 이슬은 지표의 물체가 야간복사에 의해 냉각되어 부근의 기온이 노점이하로 떨어지면서 응결되어 생성된 것이다(김광식, 1995). 이슬생성의 세 가지 기본적인 조건은 풍부한 습기와 충분한 야간복사냉각 그리고 지면이나 풀잎사귀 등에 수분이 풍부하여야 한다. 충분한 습기는 주위의 호수 또는 연안으로부터 공급이나 비가 온 후의 습한 토양에서 공급된다고 할 수 있다. 우리나라에 늦여름부터 늦가을까지 이슬이 많이 생기는 이유가 이와 같은 조건을 갖추었기 때문이다. (중략)

  • PDF

The Impact of Interaction between Cloud and Longwave Radiation In Asia Monsoon Circulation (구름-장파복사 상호작용이 아시아 몬순 순환에 미치는 영향)

  • Yu, Geun-Hyeok;Son, Byeong-Ju
    • 한국지구과학회:학술대회논문집
    • /
    • 2003.09a
    • /
    • pp.112-125
    • /
    • 2003
  • 구름의 몬순의 활동에 있어서 직접적으로나 간접적으로 영향을 준다. 본 연구에서는 이러한 구름이 몬순의 활동에 어떠한 영향을 주는지를 알아보기 위해 ISCCP 구름자료와 GAME 재분석 자료를 입력자료로한 장파 복사 모델을 수행하였다. 모델 수행의 결과로 얻어진 대기 상부에서의 플럭스는 CERES 관측치와 비교하였으며, 구름에 의한 가열율은 몬순활동을 해석하기 위해 사용하였다. 구름이 몬순에 끼치는 영향을 파악하기 위해 맑은 대기의 가열율과 구름을 포함한 평균 대기의 가열율의 차이를 구하였으며, 이를 수평과 연직분포의 관점에서 해석하였다. 가열율의 지리적 분포는 수평적으로는 인도양에서 장파 복사 가열율의 최대가 나타났으며, 가열의 최저 (냉각)은 티벳고원에 나타났다. 이러한 공간적 분포는 구름이 남북방향으로 차등가열을 유발시키고 있음을 보여주고 있어 구름의 분포가 열적인 몬순순환을 강화시켜주고 있음을 시사하고 있다. 이러한 차등가열의 강화는 동서방향으로도 나타나 구름이 동서방향 순환에도 영향을 줄 수 있음을 보여준다. 구름에 의한 복사 가열의 연직구조는 운정에 의한 냉각과 운저에 의한 가열이 일어날 수 있음을 보여주고 있으며, 이로 인해 대기의 불안정성이 높아져 연직 운동을 향상시킬 수 있는 역할을 하고 있음이 밝혀졌다. 즉 몬순순환에 의해 생성된 구름은 구름 생성의 원인이 되었던 순환을 더욱 강화시키고 있음을 보이고 있다.

  • PDF

An Experimental Study on the Reduction Effects of Shading Devices on Sky Radiant Cooling in Winter (차양장치의 겨울철 천공복사 냉각 저감 효과에 관한 실험적 연구)

  • Kim, Jin-Hee;Kim, Young-Tag;Lee, Soo-Yeol;Choi, Won-Ki
    • Land and Housing Review
    • /
    • v.12 no.1
    • /
    • pp.129-137
    • /
    • 2021
  • External shading devices are well known solar control devices that can help reduce the cooling load of commercial buildings. For this study, experiments were conducted to examine the feasibility of shading devices in reducing both the cooling and heating loads. The influence of sky radiant cooling during winter was verified for the external shading device, internal roller blind, and window. Results can be summarized as follows. The temperature difference between the inner and outer surfaces of the window with the external shading device was 11.8℃ compared to 14.6℃ for one without the external shading device. This 2.8℃ difference was due to heat exchange by sky radiation when the surface temperature of the shading device was lower than the ambient outdoor air temperature. The roller blind resulted in a lower temperature of 0.8℃ compared to the average temperature of the window's air cavity. This was due to heat exchange by sky radiation of the roller blind surfaces. Without shading devices, the outside surface temperature of the window is about 3℃ higher. The study also found that when external shading devices were installed on both the southwest and southeast sides, the outside surface temperature of the windows were lower on the southwest side than the southeast side.

Prediction of Temperature Distribution for Heat Treatment of 2.5% C-15% Cr Sleeve Casting Roll for Coke Biquette (2.5% C-15% Cr 성형탄 슬리이브 캐스팅로울의 열처리에 대한 온도 분포예측)

  • 하만영;윤영환
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.3
    • /
    • pp.408-418
    • /
    • 1986
  • 본 연구에서는 표면은 단단하고 내면은 강인한 조직을 얻기위하여 대형 성형 탄 로울에 대하여 노에서의 급속가열 및 대기 상태에서의 자연냉각의 열처리가 수행 되어진다. 급속가열 및 냉각시 성형탄 로울 내부의 온도 분포 예측을 위하여 대류 및 복사 열전달 경계조건을 가지는 1차원 비정상 열전도 방정식이 유한 차분법을 사 용하여 해석되어졌다. 여기서 급속가열시 연소가스로 부터 기체복사에 의하여 성 형탄 로울의 바깥표면을 통하여 흡수되는 열량은