• Title/Summary/Keyword: 복부촬영

Search Result 352, Processing Time 0.021 seconds

Limitations of 99mTc-DMSA scan in diagnosing acute pyelonephritis in children (이해관계 선언)

  • Kim, Byung Gee;Kwak, Jae Ryoung;Park, Ji Min;Pai, Ki Soo
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.3
    • /
    • pp.408-413
    • /
    • 2010
  • Purpose : We aimed to prove the relative limitation of $^{99m}Tc-DMSA$ scintigraphy (DMSA) compared to computed tomography (CT) in diagnosing acute pyelonephritis (APN) in children. Methods : Since September 2006, after a 64-channel CT was imported, 10 DMSA false-negative patients have been identified: these patients underwent a CT scan for acute abdomen or acute febrile symptoms and were diagnosed as having APN; however, their DMSA scans were clear. We focused on these 10 DMSA false-negative patients and analyzed their clinical findings and CT results. We used Philips Brilliance Power 64-channel CT scanner for the CT scan and Siemens Orbitor Nuclear Camera 60 Hz for the DMSA scan. Results : The 10 DMSA false-negative patients were mostly males (80%) and infants (80%). They had fever for a mean of 1.1-day duration before admission and showed increase in acute reactants: leukocyte, erythrocyte sedimentation rate, and C-reactive protein. The CT findings of renal lesions were focal in 6 (60%) cases and diffuse in 4 (40%) cases, and most of the lesions were unilateral in 80% of patients. CT proved that 22 renal lesions were neglected by DMSA. Differential renal function test by DMSA was also of no use in the evaluation of renal lesions. Conclusion : In this study, DMSA scan showed limitation in finding renal cortical lesions of CT-proven APN patients. DMSA false-negative results seem to occur at early-phase disease of infantile age, but more prospective studies are needed to determine the reasons and their prevalence.

A Case of Eosinophilic Gastritis Mimicking Borrmann Type-4 Advanced Gastric Cancer (Borrmann 4형 진행위암과 같은 형태를 보인 호산구성 위염(Eosinophilic Gastritis) 1예)

  • Shin Hyun-Wook;Suh Byoung-Jo;Yu Hang-Jong;Lee Hye-Kyung;Kim Jin-Pok
    • Journal of Gastric Cancer
    • /
    • v.5 no.1
    • /
    • pp.47-51
    • /
    • 2005
  • Eosinophilic gastroenteritis is a rare clinicopathologic entity of unknown etiology with a variety of digestive symptoms. The pathogenesis is poorly understood. Diagnostic criteria include demonstration of eosinophilic infiltration of the affected bowel wall, lack of evidence of extraintestinal disease, and exclusion of various disorders that could mimic similar conditions. The disease might involve any area of the gastrointestinal tract from the esophagus to the rectum, but the stomach and the proximal small bowel are most commonly affected. The clinical features depend on which layer and site are involved. We report the case of a 59-year-old male patient with a 3-week history of post-prandial vomiting with malnutrition and weight loss. An abdominopelvic CT showed a gastric outlet obstruction with diffuse wall thickening, as with linitis plastica. Three gastrofiberscopic biopsies showed chronic gastritis. We carried out a radical total gastrectomy with D2 lymph node dissection. The pathologic report revealed a mural type eosinophilic gastritis with a marked hypertrophic scar formation at the proper muscle layer. We report this case with a brief review of the literature. (J Korean Gastric Cancer Assoc 2005;5:47-51)

  • PDF

A Case of Giant Gastric Schwannoma Accompanied with Bleeding (출혈을 동반한 거대 위 신경초종 1예)

  • Kim, Je-Yeon;An, Ji-Yeong;Choi, Min-Gew;Noh, Jae-Hyung;Sohn, Tae-Sung;Kim, Sung
    • Journal of Gastric Cancer
    • /
    • v.6 no.1
    • /
    • pp.47-51
    • /
    • 2006
  • The origin of a submucosal tumor is difficult to determine by endoscopic biopsy. One type of submucosal tumor, which originates in Schwann cell, a schwannoma represents 0.2% of all gastric tumors. We experienced the case of a 57-year-old female patient with a gastric schwannoma presenting with melena and anemia. Computed tomography and upper gastrointestinal endoscopy showed a protruded huge mass from 3 cm below the cardia to angle. Seven endoscopic biopsies indicated only necrotic debri and granulation tissue, chronic gastritis. Because we suspected an advanced gastric cancer, or lymphoma with bleeding, It was performed an operation for an exact diagnosis and a treatment for bleeding. A-post-operative histopathological, immunohistochemical examination led to the final diagnosis of a gastric schwannoma.

  • PDF

A Case of Bronchiectasis with High Serum CA19-9 (혈중 CA19-9이 지속적으로 상승되었던 기관지 확장증 환자 1예)

  • Huh, Jung Hun;Lee, Su Mi;Koo, Tae Hyoung;Shin, Bong Chul;Um, Soo Jung;Yang, Doo Kyung;Lee, Soo-Keol;Son, Choonhee;Rho, Mee Sook;Kim, Ki Nam;Lee, Ki Nam;Choi, Pil Jo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.64 no.5
    • /
    • pp.383-386
    • /
    • 2008
  • An elevated serum CA19-9 level is an indication of pancreatic and biliary tract cancer. However, it has recently become known that nonmalignant gastrointestinal diseases and a variety of nonmalignant respiratory diseases, such as idiopathic interstial pneumonia, collagen vascular disease associated lung diseases, diffuse panbronchiolitis and bronchiectasis, can also show an elevated serum CA19-9 level. We recently encountered a case of bronchiectasis with persistently elevated serum CA19-9, but without any evidence of malignant disease in endoscopic retrograde pancreatocholangiography, abdominal computed tomography, and positron emission tomography. After serial follow-up of 3 years and 10 months, there was still no evidence of cancer. It is believed that the elevated serum CA19-9 level was due to bronchiectasis. An elevated serum CA19-9 level should be interpreted carefully with the patients' clinical condition.

A Clinical Study of Congenital Duodenal Obstruction (선천성 십이지장 폐쇄증의 임상적 고찰)

  • Huh, Young-Soo;Suh, Bo-Yang;Kwun, Koing-Bo
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.2
    • /
    • pp.39-48
    • /
    • 1990
  • Congenital duodenal obstruction in the newborn infant may be due to a variety of causes. Duodenal obstruction often presents with bilious vomiting and upper abdominal distention. Diagnosis is usually established on plain x-ray of the abdomen by the classic finding of the double-bubble. In the period July 1986 to June 1990, 16 patients with congenital duodenal obstruction were operated and the following results were obtained. 1. Sixteen patients were comprised of 11 males and 5 females, the ratio of male and female was 2.2:1. 2. Thirteen patients(81%) had been admitted to our hospital during one month of life. 3. Congenital duodenal obstruction was in 16 cases; malrotation in eight(50%), annular pancreas in six(38%), type 1 atresia in one(6%), and wind-sock anomaly in one(6%). 4. There were two premature patients and six patients of small for gestational age. 5. Overall, bilious vomiting, occurring in three fourths, was the single most frequent presenting complaint. 6. Polyhydramnios occurred in two of the patients. 7. Diagnosis was possible with clinical symptom and simple abdomen. 8. The operative procedures performed were ; duodenoduodenostomy in five, duodenojejunostomy in two, excision of wind-sock membrane in one, and Ladd's procedure in eight. 9. A total of ten asociated congenital anomalies were found in six patients. 10. Postoperative complications occurred in five cases(31%).

  • PDF

Survey of CT Practice and Collective Effective Dose Estimation (CT검사건수 및 CT검사에 의한 집단 실효선량의 추정)

  • Lee, Man-Koo;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.231-237
    • /
    • 2010
  • Computed tomography (CT) has been established as an important diagnostic tool in clinical medicine and has become a major source of medical exposure. A nationwide survey regarding CT examinations was carried out in 2007. Thanks to the appeasement policy regulating the import of CT scanners, there are 1,825 CT scanners across the country as of the end of March 2010, which means that we have 36.8 CT scanners per one million people. The annual number of examinations was 3.29 million, the number of examinations per 1000 population was 68. The most part of examinations was abdomen and pelvis. and the collective effective dose was in these parts. The effective dose per one population was evaluated as 0.952 mSv.

Probe of Unfilled Sheath of Prestressed-Concrete Girder Bridge Using Impact-Echo Method (충격탄성파법을 이용한 PC형교의 쉬이스 내부 그라우트 미충전부 탐사)

  • Lee, Sang Hun;Kim, Sang Jin;Endo, Takao;Sagara, Yuzo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.112-119
    • /
    • 2011
  • Sheaths are arranged in the web and lower part of prestressed-concrete girder bridges, and prestressing wires and concrete are indirectly bonded together by filling interior parts of the sheaths. However, when the filling is not sufficient, water can penetrate the interior parts of the sheaths and, thereby, prestressing wires can be corroded or transverse cracks would occur around sheaths by the freezing and thawing action of the penetrated water. Therefore, it is an important element in maintenance management of structures to find out the sheaths unfilled with grout early after construction. In this paper, in order not to damage bridge members, the impact-echo method with a new approach in application is used to probe sheaths unfilled with grout for real structures. The location of sheaths is first estimated with reinforcing bar probing instrument of radar type and the measurement locations of sheaths are determined. By sending elastic wave to the side of girders and receiving the response, the location of the unfilled part of a sheath was estimated from the difference between high frequency peak and twice the resonance frequency indicating thickness. To verify the location of void estimated by the impact-echo method, pictures were taken by an industrial fiber scope after drilling a hole.

Massive pneumoperitoneum following cardiopulmonary resuscitation (심폐소생술 후 발생한 다량의 기복증)

  • Choi, Jeonjwoo;Shin, Sangyol;Hwang, Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3303-3307
    • /
    • 2015
  • The purpose of this study was attemped to investigate the clinical presentation and pathophysiology of 74-year-old female who developed pneumoperitoneum as complications of chest compression from sudden cardiac arrest. Such chest compression is the same one excercised to by-stander and paramedics. A healthy 74 year female had a sudden mental deterioration while working at a restaurant. She was transfered from 119 emergency medical system to the hospital. After the symptom developed, by-stander called 119 who carry out 6 minutes Cardiopulmonary resuscitation(CPR). Defibrillation and CPR was carried out by health provider after the arrival, and the patients spontaneous circulation returned. After Return of spontaneous circulation(ROSC), patients was transferred to the nearst hopspital, but suspicious of myocardial infarction, she was again transferred to a larger scale hospital. At the hospital she took X-rays and Abdominal CT, and the results of suspicious gastro-intestinal perforation near gastro-esophageal junction, surgical repair was recommended. But in operation room, while operation went on, cardiopulmonary arrest appeared again, and she expired. For this reason, prehospital CPR needs more accurate localization of cardiac massage and serious consideration of positive pressure ventilation. Moreover, treatment of pneumoperitoneum after CPR needs more cautious consideration of patients hemodynamic stability.

Effects on Patient Exposure Dose and Image Quality by Increasing Focal Film Distance in Abdominal Radiography (복부 일반촬영시 초점-필름간거리 변화가 피폭선량 및 화질에 미치는 영향)

  • Kim, You-Hyun;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.52-58
    • /
    • 1998
  • We can and must improve the diagnostic images using available knowledge and technology. At the same time we must strive to reduce the patient's integral and entrance radiation dose. Reducing the integral dose to the patient during the radiologic procedure is a primary concern of the patient, especially the pediatric patient, the radiologist and the technologist. A 100cm focal film distance generally is used for most over-table radiography. The early x-ray tubes and screen film combinations required long exposures, which often resulted in motion artifacts. But nowaday, we have the generators and x-ray tubes that can deliver the energy necessary in a very short time and the receptors that can record the information just as rapidly. And, we performed this studies to evaluate the patient exposure dose and the image quality by increasing focal film distance in diagnostic radiography. There are many factors which affected to exposure factor, but we studied to verify of FFD increase, only. Effect of increasing the focal film distance to a 140 cm distance was tested as follows; 1. The focal film distances were set at 100, 120, and 140cm. 2. A 18cm acryl(tissue equivalent) phantom was placed on the table top. 3. An Capintec 192 electrometer with PM 05 ion chamber was placed at the entrance surface of the phantom, and exposure were made at each focal film distances. 4. The procedure was repeated in the same manner as above except the ion chamber was placed beneath the phantom at the film plane. 5. Exit exposure were normalize to 8mR for each portions of the experiment. Based on the success of the empirical measurements, a detailed mathematical analysis of the dose reduction was performed using the percent depth dose data. The results of this study can be summerized as followings ; 1) Increasing FFD from 100 cm to 140 cm, we would create a situation that would have a significant effect on the overall quality of radiograph and achive the 17.42% reduction of entrance dose and the 18.95% reduction of integral dose that the patient receives. 2) Thickness of Al step wedge for equal film density increased with the long distance. 3) Increasing FFD, Magnification of image was lowered. 4) Resolution of image also increased with the FFD. As the results described above, we strongly recommend using the long FFD to provide better information for our patients and profession in abdomen radiographic studies.

  • PDF

Set Up and Operation for Medical Radiation Exposure Quality Control System of Health Promotion Center (건강검진센터의 의료방사선 피폭 품질관리 시스템 구축 운영 경험 보고)

  • Kim, Jung-Su;Jung, Hae-Kyoung;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.13-17
    • /
    • 2016
  • In this study, standard model of medical radiation dosage quality control system will be suggested and the useful of this system in clinical field will be reviewed. Radiation dosage information of modalities are gathered from digital imaging and communications in medicine(DICOM) standard data(such as DICOM dose SR and DICOM header) and stored in database. One CT scan, two digital radiography modalities and two mammography modalities in one health promotion center in Seoul are used to derive clinical data for one month. After 1 months research with 703 CT scans, the study shows CT $357.9mGy{\cdot}cm$ in abdomen and pelvic CT, $572.4mGy{\cdot}cm$ in brain without CT, $55.9mGy{\cdot}cm$ in calcium score/heart CT, screening CT at $54mGy{\cdot}cm$ in chest screening CT(low dose screening CT scan), $284.99mGy{\cdot}cm$ in C-spine CT and $341.85mGy{\cdot}cm$ in L-spine CT as health promotion center reference level of each exam. And with 1955 digital radiography cases, it shows $274.0mGy{\cdot}cm2$ and for mammography 6.09 mGy is shown based on 536 cases. The use of medical radiation shall comply with the principles of justification and optimization. This quality management of medical radiation exposure must be performed in order to follow the principle. And the procedure to reduce the radiation exposure of patients and staff can be achieved through this. The results of this study can be applied as a useful tool to perform the quality control of medical radiation exposure.