• Title/Summary/Keyword: 보철 치료

Search Result 703, Processing Time 0.029 seconds

The effects of desensitizing agents, bonding resin and tooth brushing on dentin permeability, in vitro (지각과민 처치제 후 접착레진 처리가 상아질 투과도에 미치는 영향)

  • Hong, Seung-Woo;Park, No-Je;Park, Young-Bum;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.165-176
    • /
    • 2014
  • Purpose: The effects of desensitizing agent are often for a short duration. One of the reasons is believed to be wear of desensitizing agent by tooth brushing. To reduce the wear and make the duration longer, dental bonding resin was applied and the changes of dentin permeability after toothbrushing were measured. Materials and methods: Extracted teeth free from caries were chosen. Coronal dentin discs with thickness of 1 mm were prepared. Using the split chamber device developed by Pashely, hydraulic conductance and scanning electron microscope images (SEM) were compared and contrasted before and immediately after the application of desensitizing agent and bonding resin and then after equivalent tooth brushing of 1 week, 2 weeks, and 6 weeks. Four commercially available desensitizing agents were used in this study; they were All-Bond 2, Seal & Protect, Gluma, and MS Coat. And Dentin/Enamel Bonding resin (Bisco Inc.) was used. The results of this study are as follows. Results: On all specimens, the hydraulic conductance decreased after the application of tooth desensitizing agent and bonding resin. Compared with the specimens treated only with desensitizer, the specimens treated with All-Bond 2, Gluma, MS Coat and plus D/E bonding resin had a little increase in hydraulic conductance after 1, 2 and 6-week tooth brushing. In case of Seal & Protect, the specimens showed the same result only after 6-week tooth brushing. On examination of SEM, the dentinal tubule diameter had decreased after treatment of desensitizing agents and bonding resin. And the specimens treated with All-Bond2, Seal&Protect, Gluma, MS Coat and plus D/E bonding resin had an significant decrease in diameter of dentinal tubule after 6-week tooth brushing. Conclusion: According to the results of this study, it is effective to use bonding resin after application of desensitizer in reducing the wear by tooth brushing and making the duration longer. In this study, just 6-week tooth brushing was performed, and it is not enough to regard it as a long-term data. So further study is needed and more perfect method for treating dentin hypersensitivity should be developed.

Comparison of condylar guidance using ARCUSdigma 2 and Checkbite (ARCUSdigma 2와 Checkbite를 사용하여 측정한 과로경사각 비교)

  • Lee, Dong-In;Lee, Chang-Hee;Son, Mee-Kyoung;Chung, Chae-Heon;Kang, Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.153-159
    • /
    • 2013
  • Purpose: Nowadays, checkbite methods and a digital sensor are used to analyze the movement of mandible. However, there are no study comparing two methods. Therefore, this study has compared measuring the condylar inclination methods by using the new ARCUSdigma 2 system and the checkbite method. Materials and methods: Young 20 adults without any orthodontic treatment experiences, missing teeth, and restorations with the change of occlusal plane were tested. Angles of condylar path were measured 3 times each, based on Camper's line, by using two methods. KaVo PROTAR Evo 7 semi-adjustable articulator was used and the data were statistically analyzed. Results: 1. The anterior sagittal condylar inclination by ARCUSdigma 2 system were measured as $26.97^{\circ}({\pm}7.38^{\circ})$ on the left side and $29.80^{\circ}({\pm}8.19^{\circ})$ on the right side. The lateral condylar inclination were measured as $5.75^{\circ}({\pm}3.47^{\circ})$ on the left side and $8.10^{\circ}({\pm}4.98^{\circ})$ on the right side. 2. The anterior sagittal condylar inclination by checkbite method were measured as $25.20^{\circ}({\pm}6.53^{\circ})$ on the left side and $28.18^{\circ}({\pm}7.38^{\circ})$ on the right side. The lateral condylar inclination were measured as $10.97^{\circ}({\pm}5.63^{\circ})$ on the left side and $12.03^{\circ}({\pm}5.22^{\circ})$ on the right side. There was no statistically significant difference between male and female (P>.05). 3. The lateral condylar inclinations of ARCUSdigma 2 were statistically significantly smaller than that of checkbite method (P<.05). Conclusion: In Both of 2 methods, there was no statistically significant difference between male and female (P>.05). However, the lateral condylar inclinations of ARCUSdigma 2 were statistically significantly smaller than that of checkbite method (P<.05).

Evaluation of the accuracy of two different surgical guides in dental implantology: stereolithography fabricated vs. positioning device fabricated surgical guides (제작방법에 따른 임플란트 수술 가이드의 정확성비교: stereolithography와 positioning device로 제작한 수술 가이드)

  • Kwon, Chang-Ryeol;Choi, Byung-Ho;Jeong, Seung-Mi;Joo, Sang-Dong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.271-278
    • /
    • 2012
  • Purpose: Recently implant surgical guides were used for accurate and atraumatic operation. In this study, the accuracy of two different types of surgical guides, positioning device fabricated and stereolithography fabricated surgical guides, were evaluated in four different types of tooth loss models. Materials and methods: Surgical guides were fabricated with stereolithography and positioning device respectively. Implants were placed on 40 models using the two different types of surgical guides. The fitness of the surgical guides was evaluated by measuring the gap between the surgical guide and the model. The accuracy of surgical guide was evaluated on a pre- and post-surgical CT image fusion. Results: The gap between the surgical guide and the model was $1.4{\pm}0.3mm$ and $0.4{\pm}0.3mm$ for the stereolithography and positioning device surgical guide, respectively. The stereolithography showed mesiodistal angular deviation of $3.9{\pm}1.6^{\circ}$, buccolingual angular deviation of $2.7{\pm}1.5^{\circ}$ and vertical deviation of $1.9{\pm}0.9mm$, whereas the positioning device showed mesiodistal angular deviation of $0.7{\pm}0.3^{\circ}$, buccolingual angular deviation of $0.3{\pm}0.2^{\circ}$ and vertical deviation of $0.4{\pm}0.2mm$. The differences were statistically significant between the two groups (P<.05). Conclusion: The laboratory fabricated surgical guides using a positioning device allow implant placement more accurately than the stereolithography surgical guides in dental clinic.

Effect of Tightening Torque on Abutment-Fixture Joint Stability using 3-Dimensional Finite Element Analysis (임플란트 지대주나사의 조임회전력이 연결부 안정성에 미치는 영향에 관한 3차원 유한요소해석 연구)

  • Eom, Tae-Gwan;Suh, Seung-Woo;Jeon, Gyeo-Rok;Shin, Jung-Wook;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.125-135
    • /
    • 2009
  • Statement of problem: Loosening or fracture of the abutment screw is one of the common problems related to the dental implant. Generally, in order to make the screw joint stable, the preload generated by tightening torque needs to be increased within the elastic limit of the screw. However, additional tensile forces can produce the plastic deformation of abutment screw when functional loads are superimposed on preload stresses, and they can elicit loosening or fracture of the abutment screw. Therefore, it is necessary to find the optimum tightening torque that maximizes a fatigue life and simultaneously offer a reasonable degree of protection against loosening. Purpose: The purpose of this study was to present the influence of tightening torque on the implant-abutment screw joint stability with the 3 dimensional finite element analysis. Material and methods: In this study, the finite element model of the implant system with external butt joint connection was designed and verified by comparison with additional theoretical and experimental results. Four different amount of tightening torques(10, 20, 30 and 40 Ncm) and the external loading(250 N, $30^{\circ}$) were applied to the model, and the equivalent stress distributions and the gap distances were calculated according to each tightening torque and the result was analyzed. Results: Within the limitation of this study, the following results were drawn; 1) There was the proportional relation between the tightening torque and the preload. 2) In case of applying only the tightening torque, the maximum stress was found at the screw neck. 3) The maximum stress was also shown at the screw neck under the external loading condition. However in case of applying 10 Ncm tightening torque, it was found at the undersurface of the screw head. 4) The joint opening was observed under the external loading in case of applying 10 Ncm and 20 Ncm of tightening torque. 5) When the tightening torque was applied at 40 Ncm, under the external loading the maximum stress exceeded the allowable stress value of the titanium alloy. Conclusion: Implant abutment screw must have a proper tightening torque that will be able to maintain joint stability of fixture and abutment.

A study of lower facial change according to facial type when virtually vertical dimension increases (가상적 수직 교합 고경 증가 시 안모의 유형에 따른 하안모 변화에 관한 연구)

  • Kim, Nam-Woo;Lee, Gung-Chol;Moon, Cheol-Hyun;Bae, Jung-Yoon;Kim, Ji-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the effect of increased vertical dimension of occlusion on lower facial changes by facial type. Materials and methods: Lateral cephalograms from 261 patients were obtained and classified by sagittal (Class I, II, and III) and vertical (hypodivergent, normodivergent, and hyperdivergent) facial patterns. Retrusive displacement of soft tissue Pogonion and downward displacement of soft tissue Menton were measured in each group after 2 mm of vertical dimension of occlusion was increased at the lower central incisor using a virtual simulation program. The ratio of both displacements was calculated in all groups. The statistical analysis was done by 2-way ANOVA and Post hoc was done by Tukey test (5% level of significance). Results: Retrusive displacement of soft tissue Pogonion in Class III group was statistically different compared to Class I and II, and in vertical facial groups all 3 groups were significantly different (P<.05). Downward displacement of soft tissue Menton showed statistically significant difference between all sagittal groups and vertical groups (P<.05). The ratio of both displacements showed statistically significant difference in all sagittal groups and vertical groups (P<.05), and Class II hyperdivergent group had the highest value. Conclusion: Lower facial change was statically significant according to the facial type when vertical dimension of occlusion increased. Class II hyperdivergent facial type showed the highest ratio after increase in vertical dimension of occlusion.

Gender Differences in Nasalance Scores in Korean Speaking Adults (비음측정기를 이용한 한국어를 사용하는 정상 성인에서 성별에 따른 비음도의 차이에 관한 연구)

  • Kwon, Ho-Beom;Choi, Song-Un;Chang, Seok-Woo;Lee, Seok-Hyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.1
    • /
    • pp.19-27
    • /
    • 2008
  • The purpose of this study was to obtain normative nasalance scores for adult subjects speaking the Korean language and to determine whether significantly different scores exist for female and male speakers. Mean nasalance scores were obtained for normal speaking Korean adults while they are reading vowels, consonants, no nasal sentence, mild nasal sentence, and high nasal sentence. Thirty adults who had lived in Seoul area with normal articulation, resonance, and voice were included. Among the subjects 15 were male aged 24-38 years and 15 were female aged 19-33. Nasometer data were collected and analyzed using the Kay Nasometer 6400. Nasalance scores were evaluated to investigate the effect of gender by using statistical tests. Nasalance data showed that nasalance values varied accroding to speech stimuli, and there was no significant difference in nasalance scores between male and female speakers in most of the language samples.

Anatomical characteristics of the midpalatal suture area for miniscrew implantation using CT image (정중구개봉합부의 해부학적 구조에 관한 전산화 단층촬영을 이용한 연구)

  • Park, Young-Chel;Lee, Jong-Suk;Kim, Doo-Hyung
    • The korean journal of orthodontics
    • /
    • v.35 no.1 s.108
    • /
    • pp.35-42
    • /
    • 2005
  • There is lack of data for the amount of vertical bone in the midpalatal region for miniscrew implantation. The purpose of this study was to measure the structure of the midpalatal suture area using CT image and V-works 4.0 program (Cybermed Inc, Seoul, Korea). CT images of 14 male and 14 female adults were reconstructed. In detail, it was 1) to measure the length of maxilla on the midsagittal plane 2) to measure vertical bone height in the midpalatal area 3) to establish the zone of safety for miniscrew implantation. The following results were obtained. The mean length of ANS-PNS was 51.08mm in males and 47.34mm in females. There was a statistically significant difference between males and females (p<0.05). The vertical bone height of the midpalatal suture area was above 0mm except for 6mm posterior from the central Point of ANS-PNS in males The zone of safety was located 19.43mm posterior from the ANS in males while it was 17.62mm in females along the palatal plane. These results support that the safety zone of the midpalatal area is suitable for screw implantation. Midpalatal miniscrew implantation is a powerful tool in modern orthodontics Through many applications. it can expand the modern orthodontic field.

REMOVABLE FLEXIBLE DENTURE FOR CHILDREN WITH OLIGODONTIA : A CASE REPORT (탄성의치를 사용한 부분무치증 환아의 보철적 수복)

  • Kim, Jin-Young;Lee, Kwang-Hee;La, Ji-Young;Lee, Dong-Jin;An, So-Youn;Kim, Yun-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.1
    • /
    • pp.150-156
    • /
    • 2009
  • Objectives : The conventional removable appliance, composed of wires and acrylic resin, had unaesthetic results and poor retention. The flexible denture, as an alternative, presents improved aesthetics with the thin and strong resin retentive area. In addition, it also enhances patients' sensory function as a result of decreased volume of denture base. The flexibility of the flexible denture reduces the possibility of fracture and distributes the masticatory forces transmitted to the abutments and residual bone tissue. This report describes a 10-year-old girl and a 6-year-old boy with oligodontia treated with the flexible dentures as an alternative to conventional removable appliances. Methods : Impression was taken using alginate material and sent to a laboratory with the bite for fabrication of the flexible denture. Prior to try-in, the flexible denture was immersed in water at $90^{\circ}C$ for one minute and cooled. Impinging area of the denture was checked by $Fit-Checker^{(R)}$ and removed and the denture was delivered to the patient. Results : Both patients were satisfied with the flexible dentures, which presented improved retention and aesthetics. Conclusion : For patients with oligodontia, flexible dentures can be considered as a treatment of choice, which may replace the conventional denture.

  • PDF

Factors associated with the survival rate and the marginal bone loss of dental implant over 7-years loading (7년 이상 기능한 임플란트의 변연골 흡수와 생존율에 영향을 주는 요인)

  • Choi, Jung-Hyeok;Koh, Jae-kwon;Kwon, Eun-Young;Joo, Ji-Young;Lee, Ju-Youn;Kim, Hyun-Joo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.116-126
    • /
    • 2018
  • Purpose: The purpose of this study was to analyze the factors affecting the survival rate and the marginal bone level of dental implants that have functioned over 7-years. Materials and Methods: In 92 patients, 178 dental implants were included. Implant-related factors (diameter, length, prosthetic splint), patient-related factors (gender, smoking, plaque index, compliance to supportive periodontal therapy) and surgery-related factors (proficiency of surgeon, bone graft) were evaluated via clinical and radiographic examination. The marginal bone level was determined by intraoral standard radiography at the mesial and distal aspects of each implant using an image analysis software program. Results: The survival rate of all the implants was 94.94% and the marginal bone level was $0.89{\pm}1.05mm$, these results are consistent with other studies that present long-term good clinical results. Implant length and plaque index among several factors were statistically significant for implant survival rate (P < 0.05). Smoking and the presence of regeneration surgery were statistically significant for the marginal bone level (P < 0.05). Conclusion: Dental implant that have functioned over 7-years showed favorable long-term survival rates and marginal bone level. Implant length and plaque control should be considered for improving the long-term clinical results. It is needed that careful application of bone regeneration technique and smoking control for maintaining of marginal bone level.

A study on the correlation between oral health status and dental prosthetic treatment (구강보건 실태와 치과보철치료의 상관관계에 관한 연구)

  • Lee, Jong-Do;Kim, Jeoung-Sook
    • Journal of Technologic Dentistry
    • /
    • v.30 no.1
    • /
    • pp.109-119
    • /
    • 2008
  • The Status of oral health and dental prosthetic treatment in Daegu and Gyoung Buk area was examined. To investigate the correlation between factors such as demographic and socioeconomic characteristics and status of oral health and knowledge about oral preventive measures, a survey was performed. After analyzing the effects of knowledge levels about dental prosthetic treatment on the oral health status and preventive measures, following results were obtained. A Total of 625 people participated in the survey for three months from October 2007 to January 2008. The responses from the survey were then analyzed to assess whether those with less knowledge of preventive measures tended to have more dental prosthetic work. Of those that took part in the survey: ${\cdot}$ 30.2% were in their twenties ${\cdot}$ 56.2% were married ${\cdot}$ 51.4% of respondents had at least a college degree ${\cdot}$ 42.4% had monthly incomes below one million Won ${\cdot}$ 24.3% were students ${\cdot}$ 55.8% were from urban areas After studying the relationship between oral health and various demographics, researchers concluded that respondents' sex, income, job and place of residence had no effect on the overall status of their oral health. However, those that were divorcees or widows (1.95${_+}/{_-}$ 0.32), over the age of 70 (1.67${_+}/{_-}$0.31), or had little education (0.82${_+}/{_-}$0.28), all demonstrated a statistically significant effect on their oral health with a significance level of 0.05.Cross analysis revealed a p-value of 0.000. The correlation between knowledge of oral preventive measures and other factors was examined. No difference was found between men and women but people who were divorced or lost their spouse, people over the age of 60, and people with no education, the results of knowledge of oral preventive measure was poor as 1.74$\pm$0.44, 1.85$\pm$0.40, 1.85$\pm$0.44,and 1.60$\pm$0.47 separately. Cross analysis showed that p-value was 0.000 and correlation between knowledge of oral preventive measures and those factors were statistically significant at significance level of 0.05. The status of dental prosthetic treatment was investigated. Women, people with higher income, and married people had more dental prosthetic treatment and it was related to education, income, residential area, and the status of dental prosthetic treatment. The returns of those factors was 32.7%. Respondents$^{\circ}{\emptyset}$ oral hygiene status and knowledge of oral preventive measures was related to demographic or socioeconomic factors. Therefore, a preventive program for oral health care needs to be developed in advanced countries. Knowledge of oral health is below the international average and more research and effort needs to be put in to develop public knowledge of dental prosthetic treatment. Government intervention such as enacting an oral health initiative or dental insurance that covers prosthetic treatments is urgently needed.

  • PDF