• Title/Summary/Keyword: 보철

Search Result 5,141, Processing Time 0.034 seconds

Influences of luting cement shade on the color of various translucent monolithic zirconia and lithium disilicate ceramics for veneer restorations

  • Ghada Alrabeah;Nawaf Alamro;Atif Alghamdi;Ahmed Almslam;Meshari Azaaqi
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.5
    • /
    • pp.238-247
    • /
    • 2023
  • PURPOSE. The purpose of this study was to assess the effect of resin cement shade on the color of different novel ultratranslucent monolithic zirconia and lithium disilicate veneer materials. MATERIALS AND METHODS. For a total of 40 specimens, flat cylindrical discs with a 9-mm diameter and 0.5-mm thickness were created using CAD/CAM technology. The specimens were divided into five groups according to their material (n = 8) (e.max, Prettau, Aidite, Shofu and Dima) using A1 shade. Resin discs with the same diameter and shade as the specimens served as tooth-colored substructures. Three shades (neutral, light and warm) of resin cement try-in pastes (Variolink Esthetic LC) were used as the luting cement material. The color of each material group was measured before and after cementation using the three cement shades, and the CIE L*a*b* coordinates were obtained with a spectrophotometer. Values for the translucency parameter (TP) and color change delta E (E) before (baseline) and after cementation of each specimen were determined. To compare differences among the material groups within each shade of cement and among various shades of cement within each material, the data were analyzed using one-way ANOVA and post hoc testing. RESULTS. Color coordinates L*, a* and b* significantly changed after the application of try-in pastes relative to baseline values, with a noticeable decrease in lightness (L*) (P < .05). A significant color change (ΔE) was observed in all tested materials after cementation, with ΔE values exceeding 3.3 (P < .05). Although TP changed after cementation for most materials tested, these changes were not statistically significant (P > .05). Shofu and Dima ceramics showed the lowest TP values, while Aidite and Prettau showed the highest TP values. For e.max, translucency decreased after cementation with neutral and warm shades, and it significantly increased after cementation with a light shade. CONCLUSION. The shade of cement significantly altered the final color of the ceramic veneer material to a level above the threshold at which the clinical perception of color change occurred (> 3.3). The TP was not influenced by the cement shade. The translucency levels of the novel ultratranslucent multilayer monolithic zirconia ceramics Aidite and Prettau were higher than that of the lithium disilicate e.max material.

In vitro comparison of the accuracy of an occlusal plane transfer method between facebow and POP bow systems in asymmetric ear position

  • Dae-Sung Kim;So-Hyung Park;Jong-Ju Ahn;Chang-Mo Jeong;Mi-Jung Yun;Jung-Bo Huh;So-Hyoun Lee
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.5
    • /
    • pp.271-280
    • /
    • 2023
  • PURPOSE. This in vitro study aimed to compare the accuracy of the conventional facebow system and the newly developed POP (PNUD (Pusan National University Dental School) Occlusal Plane) bow system for occlusal plane transfer in asymmetric ear position. MATERIALS AND METHODS. Two dentists participated in this study, one was categorized as Experimenter 1 and the other as Experimenter 2 based on their clinical experience with the facebow (1F, 2F) and POP bow (1P, 2P) systems. The vertical height difference between the two ears of the phantom model was set to 3 mm. Experimenter 1 and Experimenter 2 performed the facebow and POP bow systems on the phantom model 10 times each, and the transfer accuracy was analyzed. The accuracy was evaluated by measuring the angle between the reference virtual plane (RVP) of the phantom model and the experimental virtual plane (EVP) of the upper mounting plate through digital superimposition. All data were statistically analyzed using a paired t-test (P < .05). RESULTS. Regardless of clinical experience, the POP bow system (0.53° ± 0.30 (1P) and 0.19° ± 0.18 (2P) for Experimenter 1 and 2, respectively) was significantly more accurate than the facebow system (1.88° ± 0.50 (1F) and 1.34° ± 0.25 (2F), respectively) in the frontal view (P < .05). In the sagittal view, no significant differences were found between the POP bow system (0.92° ± 0.50 (1P) and 0.73° ± 0.42 (2P) for Experimenter 1 and 2, respectively) and the facebow system (0.82° ± 0.49 (1F) and 0.60° ± 0.39 (2F), respectively), regardless of clinical experience (P > .05). CONCLUSION. In cases of asymmetric ear position, the POP bow system may transfer occlusal plane information more accurately than the facebow system in the frontal view, regardless of clinical experience.

Prediction accuracy of incisal points in determining occlusal plane of digital complete dentures

  • Kenta Kashiwazaki;Yuriko Komagamine;Sahaprom Namano;Ji-Man Park;Maiko Iwaki;Shunsuke Minakuchi;Manabu, Kanazawa
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.6
    • /
    • pp.281-289
    • /
    • 2023
  • PURPOSE. This study aimed to predict the positional coordinates of incisor points from the scan data of conventional complete dentures and verify their accuracy. MATERIALS AND METHODS. The standard triangulated language (STL) data of the scanned 100 pairs of complete upper and lower dentures were imported into the computer-aided design software from which the position coordinates of the points corresponding to each landmark of the jaw were obtained. The x, y, and z coordinates of the incisor point (XP, YP, and ZP) were obtained from the maxillary and mandibular landmark coordinates using regression or calculation formulas, and the accuracy was verified to determine the deviation between the measured and predicted coordinate values. YP was obtained in two ways using the hamularincisive-papilla plane (HIP) and facial measurements. Multiple regression analysis was used to predict ZP. The root mean squared error (RMSE) values were used to verify the accuracy of the XP and YP. The RMSE value was obtained after crossvalidation using the remaining 30 cases of denture STL data to verify the accuracy of ZP. RESULTS. The RMSE was 2.22 for predicting XP. When predicting YP, the RMSE of the method using the HIP plane and facial measurements was 3.18 and 0.73, respectively. Cross-validation revealed the RMSE to be 1.53. CONCLUSION. YP and ZP could be predicted from anatomical landmarks of the maxillary and mandibular edentulous jaw, suggesting that YP could be predicted with better accuracy with the addition of the position of the lower border of the upper lip.

Cellular responses to 3D printed dental resins produced using a manufacturer recommended printer versus a third party printer

  • Beatriz Sona Cardoso;Mariana Brito da Cruz;Joana Faria Marques;Joao Carlos Roque;Joao Paulo Martins;Rodrigo Cordeiro Malheiro;Antonio Duarte da Mata
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.2
    • /
    • pp.126-138
    • /
    • 2024
  • PURPOSE. The aim of this study was to evaluate the influence of different 3D dental resins, using a manufacturer recommended printer and a third-party printer, on cellular responses of human gingival cells. MATERIALS AND METHODS. Three NextDent resins (Denture 3D+, C&B MFH and Crowntec) were used to produce specimens on printers NextDent 5100 (groups ND, NC and NT, respectively) and Phrozen Sonic Mini 4K (groups PD, PC and PT, respectively). Human gingival fibroblasts were cultured and biocompatibility was evaluated on days 1, 3 and 7. IL-6 and IL-8 concentrations were evaluated at 3 days using ELISA. Surface roughness was evaluated by a contact profilometer. SEM and fluorescence micrographs were analyzed at days 1 and 7. Statistical analyses were performed using SPSS and mean differences were tested using ANOVA and post-hoc Tukey tests (P < .05). RESULTS. There was an increase in cellular viability after 7 days in groups PC and PT, when compared to group PD. ND group resulted in higher concentration of IL-6 when compared to PT group. SEM and fluorescence micrographs showed less adhesion and thinner morphology of fibroblasts from group PD. No significant differences were found regarding surface roughness. CONCLUSION. The use of different printers or resins did not seem to influence surface roughness. NextDent 5100 and Phrozen Sonic Mini 4K produced resins with similar cellular responses in human gingival fibroblasts. However, Denture 3D+ resin resulted in significantly lower biocompatibility, when compared to C&B MFH and Crowntec resins. Further testing is required to support its long-term use, required for complete dentures.

Regeneration of total tissue using alveolar ridge augmentation with soft tissue substitute on periodontally compromised extraction sites: case report (치주질환 원인의 심한 골소실을 동반한 발치와에 대한 치조제 증강술과 연조직 대체제를 이용한 조직 재생 효과: 증례보고)

  • Yerim Oh;Jae-Kwan Lee;Heung-Sik Um;Beom-Seok Chang;Jong-bin Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.276-284
    • /
    • 2023
  • After tooth extraction, alveolar bone is resorbed over time. Loss of alveolar bone and reduction of upper soft tissue poses difficulties in future implant placement and long-term survival of the implant. This case report focuses on increasing the soft and hard tissues at the implant placement site by using alveolar ridge augmentation and a xenogeneic collagen matrix as a soft tissue substitute in an extraction socket affected by periodontal disease. In each case, the width of the alveolar bone increased to 6 mm, 8 mm, and 4 mm, and regeneration of the interdental papilla around the implant was shown, as well as buccal keratinized gingiva of 4 mm, 6 mm, and 4 mm, respectively. Enlarged alveolar bone facilitates implant surgery, and interdental papillae and keratinized gingiva enable aesthetic prosthesis. This study performed alveolar ridge augmentation on patients with extraction sockets affected by periodontal disease and additionally used soft tissue substitutes to provide a better environment for implant placement and have positive effects for aesthetic and predictive implant surgery.

Shear Bond Strength of Composite Resin ($TESCERA^{TM}$ ATL) Veneering on Zirconia Surface with Various Surface Treatments (지르코니아의 표면처리 방법에 따른 압축강화형 복합레진 ($TESCERA^{TM}$ ATL)전장의 결합강도)

  • Park, Soo-Jeong;Lee, Richard Sung-Bok;Lee, Suk-Won;Ahn, Su-Jin;Lim, Ho-Nam
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.1
    • /
    • pp.1-13
    • /
    • 2011
  • The aim of this study was to evaluate shear bond strength of pressed reinforced composite resin ($TESCERA^{TM}$ ATL) veneering to zirconia with various surface treatments. Forty sintered zirconia specimens and forty pockmarked zirconia specimens were fabricated. All the materials were categorized as Group 1 (Control : porcelain veneering on zirconia surface), Group 2 ( $TESCERA^{TM}$ ATL dentine veneering after bonding agent application on zirconia surface), Group 3 ($TESCERA^{TM}$ ATL dentine veneering on pockmarked zirconia surface), Group 4 ($TESCERA^{TM}$ ATL dentine veneering after bonding agent application on pockmarked zirconia surface), Group 5 (Thermocycling on Group 1), Group 6 (Thermocycling on Group 2), Group 7 (Thermocycling on Group 3), and Group 8 (Thermocycling on Group 4). SBS(Shear bond strength) of 8 groups was determined with an Instron Universal Testing Machine. Also fractured surface of specimens were observed with a scanning electron microscope. There were no significant differences in the initial SBS between Group 1(control group), Group 3, and Group 4. (p>0.05) Group 2 presented the lowest SBS values. There was a no significant difference between just as 24hour water storage and simulated aging on pockmarked zirconia groups. (p>0.05) A formation of pockmarked irregularities on zirconia surface as mechanically pitted surface was reliable method for establishing a stronger bond between $TESCERA^{TM}$ ATL and zirconia-based material.

Study on Effective Preservation of Bovine Pericardium Using Decellulariation and ${\alpha}$-galactosidase for Eliminating Xenoreactive Antigen (이종 항원 제거를 위한 무세포화와 알파-갈락토시다아제를 이용한 효과적인 우심낭 보존 방법에 관한 연구)

  • Kim, Min-Seok;Park, Cham-Jin;Kim, Soo-Hwan;Lim, Hong-Gook;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.576-587
    • /
    • 2010
  • Background: Effective decellularization and fixation process is critical, in order to use xenogenic valves clinically. In the present study, we decellularized bovine pericardium using sodium dodecyl sulfate (SDS) and N-lauroyl sarcosinate, treated with $\alpha$-galactosidase, and then fixed in various manners, to find out the most effective tissue preservation & fixation procedure. Material and Method: Bovine pericardium was decellularized with SDS and N-lauroyl sarcosinate, and treated with $\alpha$-galactosidase. Both groups were fixed differently, by varying glutaraldehyde (GA) or EDC (1-ethyl-3-(3-dimethyl aminopropyl)-carbodiimide)/N-hydroxysuccinamide (NHS) treatment conditions. Thereafter, physical examination, tensile strength test, thermal stability test, cytotoxicity test, pronase test, pronase-ninhydrin test, purpald test, permeability test, compliance test, H&E staining, DNA quantification, and $\alpha$-galactose staining were carried out to each groups. Result: GA fixed groups showed better physical properties and thermal stability than EDC/NHS fixed groups, EDC/NHS-GA dual fixed groups showed better physical properties and thermal stability than EDC/NHS fixed groups, and showed better thermal stability than GA fixed groups. In pronase test and pronase-ninhydrin test, GA fixed groups and EDC/NHS-GA dual fixed groups showed stronger crosslinks than EDC/NHS groups. Permeability and compliance tended to increase in EDC/NHS-GA dual fixed groups, compared to GA fixed groups. But, EDC/NHS-GA dual fixed groups had stronger tensile strength and lower cytotoxicity than GA fixed groups. Conclusion: We have verified that EDC/NHS-GA dual fixation can make effective crosslinks and lower the toxicity of GA fixation. Henceforth, we will verify if EDC/NHS-GA dual fixation can lower calcifications & tissue failure in vivo experiment.

A Study for the development of the Korean orthodontic bracket (한국형 교정치료용 Bracket의 개발에 관한 연구)

  • Chang, Young-Il;Yang, Won-Sik;Nahm, Dong-Seok;Moon, Seong-cheol
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.565-578
    • /
    • 2000
  • The aim of this study was development of the Straight-Wire Appliance(SWA) suitable lot the treatment or Korean. To accomplish the object of this study, Korean adult with normal occlusion were selected with following criteria : 1) no functional abnormality in the craniofacial area, 2) good dental arch form and posterior occlusal relationship, 3) Angle Class I occlusal relationship, 4) no experience of orthodontic, nor prosthodontic treatment, especially, no dental treatment on labial and buccal surfaces of teeth, 5) good racial profile. Impression were taken for upper and lower dental arches or the selected normal occlusion samples and the orthodontic dental stone models were fabricated. 5 well-trained orthodontists had examined the acquired dental stone models to select study samples which satisfy the Six keys to optimal occlusion of Andrews. 155 pairs of dental stone models (92 pairs of Male, 63 of Female) were finally selected. 3 dimensional digitization were performed with the Coordinate Measuring Machine(CMM, MPC802, WEGU-Messtechnik, Germany) and measuring of Angulation, Inclination, In-and-Out, Molar offset angle and Arch form were accomplished with a measuring software to achieve data for the development of SWA. Before the measurement, error study was performed on the 3 dimensional digitization with CMM, and the analysis of reliability of computerized measuring method adapted in this study and conventional manual method Presented by Andrews was performed. Results of this study were as to)lows : 1. Equi-distance digitization with mesh size 0.25 mm, 0.5 mm and 1.0 mm were acceptable in 3 dimensional digitization of dental stone model with the CMM, and the digitization with 1.0 mm mesh size was recommendable in terms of efficiency. 2. Computerized measuring method with 3 dimensional digitization was more reliable than manual measuring method of Andrews. 3. Data were collected for the development of SWA suitable for the morphological characteristics of Korean with the computerized measuring method with 3 dimensional digitization.

  • PDF

A study of the arch length discrepancy and the diagnostic analysis (치열궁내 공간 부조화와 진단적 평가에 관한 연구)

  • Ryu, Young-Kyu;Ahn, Kwang-Seok
    • The korean journal of orthodontics
    • /
    • v.34 no.1 s.102
    • /
    • pp.1-11
    • /
    • 2004
  • Predicting the arch length discrepancy by simply comparing the available arch perimeter with tooth materials is merely a 2-dimensional analysis of the teeth movement. However, the real teeth movement takes place 3-dimensionally and is affected by various factors such as, the arch fen the curve of Spee and the axis of the incisors. The purpose of this study is to clarify the relationship between the decrease in the arch perimeter and the horizontal positional change of the incisors after extraction of the 1st bicuspids, for more analytic evaluation of the arch length discrepancy at pre-treatment model analysis stage. In addition to that to evaluate the effect of the curve of Spee, teeth axis to the basal plane, and the incisional crowding to the treatment outcome. All patients were treated at the department of orthodontics, dental hospital, Yonsei university. Inclusion criteria for patients selection were as follows. $\cdot$ Angle classification I malocclusion with bialveolar protrusion $\cdot$ Extraction of 4 1st bicuspids $\cdot$ No tooth anomaly or prosthesis $\cdot$ No abnormal attrition $\cdot$ No ectopically erupted teeth $\cdot$ Angle classification I canine and molar relationship $\cdot$ Less than 3mm of crowding Model analysis of the above patients was performed and the following conclusions were obtained. 1. When the intercanine distance was maintained, the available space for the distal movement of the mandibular incisors after the extraction of the 4 1st bicuspids was larger than the space provided by the extraction of the 4 1st bicuspids. However the difference was less than 1mm. The more tapered the anterior arch form, the larger the difference. 2. Compared to the situation in which the intercanine distance was maintained, when the intercanine distance was expanded to meet the width of the Posterior teeth, the incisors could move about 3mm more distally. 3. The positional difference of the incisal tip was insignificant whether the central incisors were moved by tipping or bodily movement. 4. When the anterior crowding was solved without changing the intercanine distance, the larger the anterior arch length was, the more the anterior movement of the incisors. 5. When the curve of Spee was levelled, the increase in the arch perimeter was less than half of the deepest curve of Spee.

The Effects of Professional Tooth Cleaning and Plaque Control Instruction on Reduction of Peri-implantitis (전문가치면세정술과 세균막관리교육의 임플란트 주위염 감소 효과)

  • Park, Kyung-Hwa;Han, Gyeong-Soon
    • Journal of dental hygiene science
    • /
    • v.12 no.2
    • /
    • pp.163-170
    • /
    • 2012
  • The purpose of this study was determine the effects of professional tooth cleaning and plaque control instruction(PT & PCI) on reduction of peri-implantitis. A total 80 implant patients were investigated using O'Leary plague index(PI), L${\ddot{o}}$e & Silness gingival index(GI), implant bone loss(BL). While the PT & PCI was conducted by using 'Watanabe method' after scaling for the experimental group, the engine polishing and a plaque control instruction was operated by rolling method after scaling for the control group. The collected data were analyzed with t-test, ANOVA, paired t-test and stepwise multiple regression. PI and GI of the experimental group significantly decreased than the control group(p<0.05). BL, also tended to decreased in the experimental group than the control group(p=0.155). Multiple regression analysis, the factors that was highly correlated with PT & PCI on the PI and GI. According to the implant characteristics, implant location and duration were closely related to PI(p<0.05). Therefore, the PT & PCI is one of the effective methods to reduce the failure caused by the peri-implantitis. Based on this conclusion, that it would be meaningful if the proposed PT & PCI is applied to the oral health management programs of the implant patients.