• Title/Summary/Keyword: 보일러 안전

Search Result 129, Processing Time 0.021 seconds

Thermal Stress Anaysis of Burning Plate by Configuration of Outdoor Gas Boiler (야외용 가스보일러의 연소판 형상에 따른 열응력 해석)

  • Lee, Suk Young
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.48-54
    • /
    • 2015
  • This study investigates the result of thermal stress analysis on burning plate by classes at outdoor gas boiler. In the analysis results at the steady state, the maximum stress and deformations are 666,8MPa at A type and 0.20476mm at B type respectively. The deformation becomes larger as the field goes on from the center to the outside at burning plate. As there are 8 types in the order of maximum stress and deformation, F and C type have safest among 8 types respectively. Therefore, F type becomes most excellent on strength and safety among 8 types. By using the analysis result of burning plate model at gas boiler, it is possible to design the model applied practically at the safe component parameters of boiler system.

산업용 보일러 효율개선을 위한 자동제어

  • 윤양균;박귀태;김석진
    • 전기의세계
    • /
    • v.37 no.6
    • /
    • pp.25-31
    • /
    • 1988
  • 본고에서는 에너지 효율개선의 측면에서 운전효율향상 뿐만 아니라 안전 및 수명연장에 기여할 수 있는 산업용 보일러의 자동제어장치에 대하여 그 개요 및 동향을 알아보기로 한다.

  • PDF

일본에서의 도시가스 안전대책

  • 관 정광
    • 보일러설비
    • /
    • s.20
    • /
    • pp.142-163
    • /
    • 1990
  • 금후 건물이나 기기의 성에너지화가 진척됨에 따라 에너지 수요를 둘러싼 에너지간의 경합이 더욱 심화될 것이 예상된다. 따라서 가스에너지의 메리트를 최대한으로 살리는 기술과 상품을 개발하여 마케팅활동의 일환으로 전개시키고 싶다. 여기서는 일본에서의 새로운 기기, 설비 및 금후의 기술개발을 중심으로 보고하고자 한다.

  • PDF

Development of Integrated Model of Boiler and Its Supporting Steel Structure of Coal-Fired Power Plant for Finite Element Analysis (유한요소해석을 위한 석탄화력발전소의 보일러와 지지 철골의 통합모델 개발)

  • Lee, Boo-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.9-19
    • /
    • 2020
  • An integrated finite element model composed of a boiler and its supporting steel structure for a 375-MW coal-fired power plant was developed. This study used the developed model for seismic analysis using SAP2000 software. For the complex superheaters, reheaters, economizers, and membrane walls of the boiler, which consisted of numerous tubes, a method of modeling them by the equivalent elements in the viewpoint of stiffness and/or inertia was proposed. In addition, a method of modeling for the connection between the boiler and steel structure was proposed. Many hangers that connect the boiler to the girders of a steel structure were transformed into equivalent hangers by decreasing the number. The displacements of the boiler stoppers on the buckstay and the posts of the steel structure were coupled by considering their interface condition. Static analysis under the self-loading condition for the developed integrated model was implemented, and the results of deformation indicated that the behavior of the steel members and the major components of the boiler were appropriate. In conclusion, the integrated model developed in this study can be used to evaluate the safety of the boiler and steel structure under seismic loads.

A Study on Accident Cases of Gas Boiler Carbon monoxide (가스보일러 일산화탄소 중독사고에 대한 사례 연구)

  • Lee, J.W.;Yeo, C.H.;Park, C.O.;Park, C.I.
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.10 no.1
    • /
    • pp.29-35
    • /
    • 2007
  • 가스보일러의 확대 보급으로 2006년도 932만대가 주택, 상가 및 산업현장 등에 보급되어 생활의 편리성이 높아지고 있으나 가스보일러의 설치불량, 관리소홀 및 제품의 노후 등으로 사고가 끊이지 않고 발생하고 있다. 가스보일러가 연소 중에 발생하는 배기가스가 실내에 유출되어 최근 5년간 30건의 사고로 사상자가 92명이 발생하는 등 1건의 사고로 3명이상의 높은 인명 피해를 나타냈다. 본 연구에서는 가스보일러의 사고통계분석과 2건의 사고사례를 분석한 결과 가스보일러의 제품의 안전성 향상과 실내에 배기가스가 누출되었을 때 신속히 검지할 수 있는 경보시스템의 방안이 필요할 것으로 보인다.