• Title/Summary/Keyword: 보온효과

Search Result 123, Processing Time 0.022 seconds

A Study of the Performance Improvement for Quilting Fabric via Postprocessing (퀼팅원단 후속가공을 통한 기능성 향상 연구)

  • Kim, Ji-Hoon;Ko, Hye-Ji
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.590-596
    • /
    • 2020
  • The fabric used for military winter inner clothing(top) is quilted with padded cotton to provide warmth. This quilting fabric is generally manufactured with yarns that intersect and are sewn substantially between the fabric and cotton. Thus, it is impossible to separate the fabric and cotton once after the quilting fabric is manufactured, which can result in a significant loss of fabric and cotton when separated. In this study, after fabricating the quilting fabric, we investigated a method to stabilize change rate of thickness and increase the warmth keeping property through subsequent processing without damaging the fabric. A relatively method of passing the quilting fabric through a part of the cotton production facility was used generally, and the following results were obtained. This indicates that after the quilting fabric was manufactured, the warmth keeping property was improved through the subsequent processing steps, so that the change rate of thickness due to washing was stabilized.

Effect of 1,8-NA and CGA 123'407 on Reducing Herbicide Injury of Rice Plants (1, 8-NA와 CGA 123'407 처리(處理)가 수도용(水稻用) 제초제(除草劑)의 약해경감(藥害輕減)에 미치는 영향(影響))

  • Pyon, J.Y.
    • Korean Journal of Weed Science
    • /
    • v.6 no.2
    • /
    • pp.154-161
    • /
    • 1986
  • Since herbicide damage has been occurred in subirrigated rice seedbed in Korea, the use of crop safener is required to reduce crop injury. Field studies were conducted to evaluate safening effect of 1,8-naphthalic anhydride (NA) and CGA 123'407 (4, 6-dichloro-2-phenyl-pyrimidine) against four kinds of paddy herbicides applied to subirrigated vinyl-covered rice seedbed. NA as a seed dressing at 0.5% (W/W) was effective in reducing rice injury from butachlor, pretilachlor, chlormethoxynil and benthiocarb, and increased number of seedling established, plant height, and dry weight of rice seedlings, while growth inhibition and stand loss were observed at 1% NA. Pretilachlor slightly decreased number of seedlings established and inhibited growth of rice seedlings. But pre-mix combination of pretilachlor (2%) and CGA 123'407 (0.5%) reduced rice injury caused by pretilachlor alone and increased number of seedlings established and dry weight of rice seedlings. The results indicate that NA and CGA 123'407 would permit the safe application of butachlor, pretilachlor, chlormethoxynil, and benthiocarb in subirrigated rice seedbed.

  • PDF

Application Effect of Heating Energy Saving Package on Venlo Type Glasshouse of Paprika Cultivation (파프리카 재배 벤로형 유리온실에서 난방에너지 절감 패키지 기술 적용효과)

  • Kwon, Jin Kyung;Jeon, Jong Gil;Kim, Seung Hee;Kim, Hyung Gweon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.225-231
    • /
    • 2016
  • Glasshouse heating package technologies to improve energy usage efficiency in winter were developed. Heating package was composed of the ground water source heat pump with heating capacity of 105kW, the aluminum multi-layer thermal curtain with six layers of different materials and the root zone local heater with XL pipes of ${\phi}20mm$. Venlo type glasshouse($461m^2$) with the heating package was compared with the same type and area control glasshouse with the light oil boiler, the usual non-woven fabric thermal curtain with respect to the glasshouse inside temperature, relative humidity, crop growth, and heating energy consumption. The results of test in paprika cultivation glasshouses showed that the air temperature inside glasshouse with aluminum multi-layer thermal curtain was maintained $2.2^{\circ}C$ higher than that of control glasshouse in un-heating night time and the temperature in bed with root zone local heating was $4.7^{\circ}C$ higher than that in bed without local heating. Average heating coefficient of performance(COP) of the ground water source heat pump used in paprika cultivation was 3.7 and the glasshouse inside temperature was maintained at $21^{\circ}C$ of heating set up temperature. The heating energy consumptions per 10a were measured at 14,071L of light oil and 364kWh of electric power for the control glasshouse and 35,082kWh for the glasshouse applied heating package. As results, the heating cost of the glasshouse applied heating package was 87 percent lower than that of control glasshouse. The growths of paprika in glasshouses of control and applied heating package did not show any significant difference.

Estimation of Heat Insulation and Light Transmission Performance According to Covering Methods of Plastic Greenhouses (플라스틱온실의 피복방식에 따른 보온 및 광투과 성능 평가)

  • Lee, Hyun-Woo;Kim, Young-Shik;Sim, Sang-Youn;Lee, Jong-Won;Diop, Souleymane
    • Journal of Bio-Environment Control
    • /
    • v.22 no.3
    • /
    • pp.270-278
    • /
    • 2013
  • The objective of the present study is to provide data needed to decide covering method to be able to increase the thermal insulation and light transmittance efficiency of commercial greenhouse. The thermal insulation effect, PPF transmittance and quantity of condensation water were estimated in experimental tomato greenhouses covered with three types of coverings of single layer, air inflated and conventional double layers covering. The overall heat flow of air inflated double layers greenhouse was similar to that of conventional double layers greenhouse, but the temperature between covering material and thermal screen in air inflated double layers greenhouse was lower than that in conventional double layers greenhouse at the same outside temperature condition due to air leakage through the gap of roof vent. The overall heat transfer coefficients acquired by experiment that was performed in single layer and conventional double layers greenhouses were close to those obtained from model experiment. Even though the PPF transmittance of air inflated double layers greenhouse was lower than that of single layer greenhouse, which was greater than that of conventional double layers greenhouse. The quantity of condensation water on covering surface of single layer greenhouse was greater than that of air inflated double layers greenhouse due to lower covering surface temperature.

Characteristics of Temperature, Humidity and PPF Distribution by Covering Method and Environmental Control in Double Covering Greenhouse (이중피복 온실의 피복방법과 환경조절에 따른 온습도 및 광합성유효광량자속 분포 특성)

  • Lee, Hyun-Woo;Sim, Sang-Youn;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.21 no.1
    • /
    • pp.1-11
    • /
    • 2012
  • The objective of the present study is to provide data needed to find double covering method to be able to improve environment of temperature, humidity and PPF in tomato greenhouse. The distribution charts of temperature, humidity and PPF which were measured in environment control conditions such as thermal insulation, air heating, roof ventilation and air fog cooling in conventional and air inflated double layers greenhouses were drawn and analysed. The thermal insulation effect of the air inflated greenhouse was the same as that of conventional greenhouse because the temperature between insulation curtain and roof covering material was equal in heating season. The ventilation effect of the air inflated greenhouse was superior to the conventional greenhouse. The temperature distribution in the fog cooled greenhouse was uniform and the cooling effect was about $3.5^{\circ}C$. The condensation on the roof covering surface could be controlled by removing the moisture between insulation curtain and roof covering by using humidifier. The PPF of conventional greenhouse was more decreased than the air inflated greenhouse as time went by because the transmittance of conventional greenhouse declined by dust collected on the inside plastic film owing to rolling up and down operation for ventilation.

Effects of Covering Materials on Prevention of Freeze Damage and Labor Saving in Saururus chinensis Baill During Wintering (삼백초의 월동 피복재 종류별 동해방지 및 노동력 절감효과)

  • Nam, Sang-Young;Kim, In-Jae;Kim, Min-Ja;Yun, Tae;Lee, Cheol-Hee;Park, Sung-Gue;Lee, Woo-Young;Kim, Hong-Sig
    • Korean Journal of Medicinal Crop Science
    • /
    • v.13 no.6
    • /
    • pp.287-292
    • /
    • 2005
  • To investigate the effects of heat conservation materials on freeze damage and weed occurrence during overwintering in Saururus chinensis, Temperature difference was $6.9^{\circ}C$ in chaff, and was lower than those ranged from 9.7 to $14.4^{\circ}C$ in other materials. Heat conservation index, calculated from average temperatures below $-10^{\circ}C$ of earth's surface during the winter, was higher $1.7^{\circ}C\;and\;1.5^{\circ}C$ in chaff and lagging, respectively than in straw. Preservation of water is greater $9.6{\sim}26.1%$ in covering than in open field, and it increased in the order of lagging > chaff > straw among heat conservation materials. The survival rate of rhizome was increased in the order of 99% in lagging > 75% in chaff > 58% in straw, 32% in open field after overwintering, budbreak began fast, and the numbers of total budbreak per unit area were greater 22 times in lagging than 35.0 units in open field. Weeds occurrence was decreased in covering, i.e., $12.0{\sim}33.2\;units/m^2,\;7.3{\sim}10.7\;kg/10a$ of dry weight, and $5.6{\sim}6.4\;hours/10a$ of labor input compared with $157.2\;units/m^2,\;28.9\;kg/10a$ of dry weight, and 65.7 hours/10a of labor input in open field. Growth of top part was better in covering than in open field, and the number of tillers per unit area showed $347{\sim}396$ compared with 293 in open field. Marketable yields of dried stem and leaves and rhizome were higher $69{\sim}87%\;and\;58{\sim}88%$, respectively in covering than in open field, and among heat conservation materials, those were highest in lagging.

The Actual State of Heat Conservation, Heating and Cooling in Greenhouses (온실의 보온 및 냉난방실태 분석)

  • 김문기;이석건;서원명;남상운;김란숙
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1998.05a
    • /
    • pp.39-44
    • /
    • 1998
  • 현재 국내에 보급되어 있는 현대화 온실 203개를 대상으로 냉난방과 관련된 설비현황을 조사하여 분석한 결과를 요약하면 다음과 같다. \circled1 온실의 건설방위는 남북동(58.1%)과 동서동(26.8%)이 대부분이었고, 철골온실은 Wide-span형이 81.8%, 플라스틱온실은 1-2W형 온실이 97.5%였다. 휴작하는 온실은 약 41%정도였고, 재배작물은 채소류가 약 80%, 화훼류가 약 20%정도였으며, 재배방식은 철골온실의 경우 양액재배가 57.2%, 플라스틱온실에서는 토양재배가 88.5%였다. \circled2 온실의 외부 피복재는 철골온실은 유리가 92.2%, 플라스틱온실에서는 PE가 43.3%, EVA가 51.9%로 대부분이었다. 철골온실은 1중피복이 98.7%로 거의 전부이었고, 플라스틱온실에서는 2중피복이 78.7%로 나타나, 철골온실에서 보온커튼을 통한 보온성 향상과 밀폐성이 더욱 중요함을 알 수 있다. \circled3 보온용 피복재는 부직포가 64.9%로 가장 많았고 대부분 2층커튼(85.9%)이었으며, 개폐방식은 대부분 예인식(92.7%)의 자동개폐방식(75.2%)이었다. 한편 바닥을 피복한 온실은 약 30% 정도로 나타나, 바닥피복으로 인한 축열이나 반사효과를 감안할 때 효율적인 바닥처리가 요망된다. \circled4 온실의 난방방식은 철골온실에서는 온수안방(47.3%)이 온풍난방(33.8%)보다 다소 많았으며, 플라스틱온실에서는 대부분 온풍난방(90.8%)이었다. 온실의 난방위치는 대부분 지상난방(89.8%)이었고 지중난방은 극소수로 나타나, 앞으로 지중난방을 통한 난방비 절감과 품질향상에 관한 실용화 연구가 요망된다. 난방용 연료는 대부분 경유(83.9%)로 나타나, 난방비를 절감할 수 있는 저가의 연료를 사용할 수 있는 난방시스템의 개발이 요청된다. \circled5 온실의 냉방방법은 차광(51.8%)과 지붕살수(33.9%)가 대부분이었으며 미스트와 포그시스템을 설치한 온실은 소수에 불과하였고, 극소수의 온실에서는 지붕위나 온실내에 지붕면과 평행하게 설치한 경우도 있었다.

  • PDF

Diurnal Variation of $CO_2$ Concentration and Air Temperature inb Polyethylene Film Covered Rice Seedbed Subjected to Various Ventilation Methods (벼 보온절충 못자리의 바람트기 방법에 따른 상내 2산화탄소 농도와 기온의 일변화)

  • 윤성호;이변우;김병찬;이정택
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.35 no.6
    • /
    • pp.543-547
    • /
    • 1990
  • Diurnal courses of $CO_2$ concentration and air temperature in the rice seedbed tunnel covered with polyethylene film, subjected to three different ventilation methods, were traced. Regaredless of ventilation methods, $CO_2$ concentrations in the tunnel on a clear day were lower than that in ambient air, and vice versa before dawn. $CO_2$ concentration during the day was lowest in the tunnel with non-ventilation (NV), followed by horizontal slit ventilation (HSV) and traditional one(TN), reaching down to the lowest level of 58ppm, 155ppm and 272ppm, respectively. Air temperature in the tunnel reached 46$^{\circ}C$ in NV, 37$^{\circ}C$ in HSV and 32$^{\circ}C$ in TV at the daytime when ambient air temperature was 22$^{\circ}C$. Even at night time of ambient air temperature below 15$^{\circ}C$, HSV was more effective than TV in raising the air temperature in the tunnel. The dry weight of 40-day old seedling weighed heaviest in HSV, followed by TV and NV.

  • PDF

A Study on the Optimum Generation Condition of Ultrasonic Guided Waves for Insulation Pipelines (단열된 배관의 유도초음파 최적 발생조건 선정에 관한 연구)

  • Lee, Dong-Hoon;Cho, Hyun-Joon;Kang, To;Park, Dong-Jun;Kim, Byung-Duk;Huh, Yun-Sil;Lee, Yeon-Jae
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.50-57
    • /
    • 2016
  • Pipeline is one of the most abundant components in petrochemical plant. It plays a critical role in transporting fluids. Some pipelines are thermally insulated by wrapping them with insulating materials to prevent the loss of energy. However, when corrosion begins under insulation, it cannot be easily seen without unwrapping the cover, and thus corrossion should be detected using a non-destructive ways such as ultrasound guided wave. In this paper, the piping where the CUI (Corrosion Under Insulation) which occurs in the insulation parts guided waves effectively the optimum condition which is theoretical for selected guided waves phase velocity dispersion curve and wave-structure. The results of this study are expected to be directly utilized for onsite inspection of pipeline's CUI in many petrochemical plants.

Effect of Fenelorim on Reducing Herbicide Injury of Rice Plaints in Vinyl-covered Subirrigated Seedbed (보온절충(保溫折衷)못자리에서 해독제(解毒劑) Fenclorim이 벼에 대한 제초제(除草劑)의 약해경감(藥害輕減)에 미치는 영향(影響))

  • Lee, H.Y.;Pyon, J.Y.
    • Korean Journal of Weed Science
    • /
    • v.8 no.3
    • /
    • pp.237-243
    • /
    • 1988
  • Field study was conducted to evaluate safening effect of fenclorim (4,6-dichloro-2-phenyl pyrimidine) against benthiocarb, butachlor, and pretilachlor injury in rice plants under vinyl-covered subirrigated seedbed. Combinated application of benthiocarb 210, and 315 g ai/10a with fenclorim 10 g ai/10a or higher concentration, butachlor 180, and 270 g ai/10a with fenclorim 20 g ai/10a or higher concentration, and pretilachlor 60, and 90 g ai/10a with fenclorim 30 g ai/10a reduced herbicide injury of rice, and thus increased standing, plant height, tillers, and dry weight of rice plants compared to no combined application of fenclorim.

  • PDF