• Title/Summary/Keyword: 보드

Search Result 2,684, Processing Time 0.031 seconds

Evaluation of the Usefulness of the Self-developed Kw-infrared Reflective Marker in Non-coplanar Treatment (비동일면 치료 시 자체 제작한 Kw-infrared Reflective Marker의 유용성 평가)

  • Kwon, Dong-Yeol;Ahn, Jong-Ho;Park, Young-Hwan;Song, Ki-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • Purpose: In radiotherapy that takes into account respiration using a RPM (Real time Position Management, Varian, USA) system, which can treat in consideration of the movement of tumor, infrared reflective markers supplied by manufacturers cannot obtain respiratory signal if the couch rotates at a certain angle or larger. In order to solve this problem, the author developed the 3D infrared reflective marker named 'Kw-marker' that can obtain respiratory signal at any angle, and evaluate its usefulness. Materials and Methods: In order to measure the stability of respiratory signal, we put the infrared reflective marker on the 3D moving phantom that can reproduce respiratory movement and acquired respiratory signal for 3 minutes under each of 3 conditions (A: $couch\;0^{\circ}$, a manufacturer's infrared reflective marker B: $couch\;0^{\circ}$, Kw-marker C: $couch\;90^{\circ}$, Kw-marker). By analyzing the respiratory signal using a breath analysis program (Labview Ver. 7.0), we obtained the peak value, valley value, standard deviation, variation value, and amplitude value. In order to examine the rotation error and moving range of the target, we placed a B.B phantom on the 3D moving phantom, and obtained images at a couch angle of $0^{\circ}$ and $90^{\circ}$ using OBI, and then acquired the X, Y and Z values (mm) of the ball bearing at the center of the B.B phantom. Results: According to the results of analyzing the respiratory signal, the standard deviation at the peak value was A: 0.002, B: 0.002 and C: 0.003, and the stability of respiration for amplitude was A: 0.15%, B: 0.14% and C:0.13%, showing that we could get respiratory signal stably by using the Kw-marker. When the couch rotated $couch\;90^{\circ}$, the mean rotation error of the ball bearing, namely, the target was X: -1.25 mm, Y: -0.45 mm and Z: +0.1 mm, which were within 1.3 mm on the average in all directions, and the difference in the moving range of the target was within 0.3 mm. Conclusion: When we obtained respiratory signal using the Kw-marker in non-coplanar treatment where the couch rotated, we could acquire respiratory signal stably and the Kw-marker was effective enough to substitute for the manufacturer's infrared reflective marker. When the rotation error and moving range of the target were measured, there was little difference, indicating that the displacement of the reflector movement in couch rotation is the cause of change in the scale and amplitude of respiratory signal. If the converted value of amplitude height according to couch angle is studied further and applied, it may be possible to perform non-coplanar phase-based gating treatment.

  • PDF

Evaluation of Skin Dose and Image Quality on Cone Beam Computed Tomography (콘빔CT 촬영 시 mAs의 변화에 따른 피부선량과 영상 품질에 관한 평가)

  • Ahn, Jong-Ho;Hong, Chae-Seon;Kim, Jin-Man;Jang, Jun-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose: Cone-beam CT using linear accelerator attached to on-board imager is a image guided therapy equipment. Because it is to check the patient's set-up error, correction, organ and target movement. but imaging dose should be cause of the secondary cancer when taking a image. The aim of this study is investigation of appropriate cone beam CT scan mode to compare and estimate the image quality and skin dose. Materials and Methods: Measurement by Thermoluminescence dosimeter (TLD-100, Harshaw) with using the Rando phantom are placed on each eight sites in seperately H&N, thoracic, abdominal section. each 4 methods of scan modes of are measured the for skin dose in three time. Subsequently, obtained average value. Following image quality QA protocol of equipment manufacturers using the catphan 504 phantom, image quality of each scan mode is compared and analyzed. Results: The results of the measured skin dose are described in here. The skin dose of Head & Neck are measured mode A: 8.96 cGy, mode B: 4.59 cGy, mode C: 3.46 cGy mode D: 1.76 cGy and thoracic mode A: 9.42 cGy, mode B: 4.58 cGy, mode C: 3.65 cGy, mode D: 1.85 cGy, and abdominal mode A: 9.97 cGy, mode B: 5.12 cGy, mode C: 4.03 cGy, mode D: 2.21 cGy. Approximately, dose of mode B are reduced 50%, mode C are reduced 60%, mode D are reduced 80% a point of reference dose of mode A. the results of analyzed HU reproducibility, low contrast resolution, spatial resolution (high contrast resolution), HU uniformity in evaluation item of image quality are within the tolerance value by recommended equipment manufacturer in all scan mode. Conclusion: Maintaining the image quality as well as reducing the image dose are very important in cone beam CT. In the result of this study, we are considered when to take mode A when interested in soft tissue. And we are considered to take mode D when interested in bone scan and we are considered to take mode B, C when standard scan. Increasing secondary cancer risk due to cone beam CT scan should be reduced by low mAs technique.

  • PDF

The Recognition and Requirement of Nutrition Labeling in Fast-Food Restaurants (패스트푸드업체에서 실시할 영양표시제 인식 및 필요성 분석 - 서울시를 중심으로 -)

  • Chung, Hea-Jung;Cheon, Hee-Sook;Kwon, Kwang-Il;Kim, Jee-Young;Yoo, Kwang-Soo;Lee, Jun-Hyung;Kim, Jong-Wook;Park, Hye-Kyung;Kim, So-Hee;Hong, Soon-Myung
    • Journal of Nutrition and Health
    • /
    • v.42 no.1
    • /
    • pp.68-77
    • /
    • 2009
  • This study was researched to provide the accurate nutrition information and the menu. We questionnaired an recognition and necessity of the nutrition labeling to 684 customers in fast-food restaurants. After data cleaning, we used spss package 14.0 and analyzed about the nutrition contents and place that display the nutrition labeling. First, we finded out lower recognition of nutrition labeling in restaurants than processed food. Second, many people hoped that calory and fat in various nutritions were displayed each 100 g or 100 mL. Third, the place displaying the nutrition information was the menu board and the counter to identify easily. Fourth, we analyzed the recognition and necessity of the nutrition labeling in fast-food restaurants by t-test and ANOVA. So, we knew that the recognition and necessity of the nutrition labeling was higher woman than man. And the more they earn much money and learned, the more the nutrition labeling are needed. But house-wife recognized the nutrition labeling lower than others.

A Study on the Serialized Event Sharing System for Multiple Telecomputing User Environments (원격.다원 사용자 환경에서의 순차적 이벤트 공유기에 관한 연구)

  • 유영진;오용선
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2003.05a
    • /
    • pp.344-350
    • /
    • 2003
  • In this paper, we propose a novel sharing method ordering the events occurring between users collaborated with the common telecomputing environment. We realize the sharing method with multimedia data to improve the coworking effect using teleprocessing network. This sharing method advances the efficiency of communicating projects such as remote education, tele-conference, and co-authoring of multimedia contents by offering conveniences of presentation, group authoring, common management, and transient event productions of the users. As for the conventional sharing white board system, all the multimedia contents segments should be authored by the exclusive program, and we cannot use any existing contents or program. Moreover we suffer from the problem that ordering error occurs in the teleprocessing operation because we do not have any line-up technology for the input ordering of commands. Therefore we develop a method of retrieving input and output events from the windows system and the message hooking technology which transmits between programs in the operating system In addition, we realize the allocation technology of the processing results for all sharing users of the distributed computing environment without any error. Our sharing technology should contribute to improve the face-to-face coworking efficiency for multimedia contents authoring, common blackboard system in the area of remote educations, and presentation display in visual conference.

  • PDF

Comparison of using CBCT with CT simulator for radiation dose of treatment planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Cho, jung-keun;Kim, dae-young;Han, tae-jong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1159-1166
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

  • PDF

Time Series Analysis of Park Use Behavior Utilizing Big Data - Targeting Olympic Park - (빅데이터를 활용한 공원 이용행태의 시계열분석 - 올림픽공원을 대상으로 -)

  • Woo, Kyung-Sook;Suh, Joo-Hwan
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.2
    • /
    • pp.27-36
    • /
    • 2018
  • This study suggests the necessity of behavior analysis as changes to a park environment to reflect user desires can be implemented only by grasping the needs of park users. Online data (blog) were defined as the basic data of the study. After collecting data by 5 - year units, data mining was used to derive the characteristics of the time series behavior while the significance of the online data was verified through social network analysis. The results of the text mining analysis are as follows. First, primary results included 'walking', 'photography', 'riding bicycles'(inline, kickboard, etc.), and 'eating'. Second, in the early days of the collected data, active physical activity such as exercise was the main factor, but recent passive behavior such as eating, using a mobile phone, games, food and drinking coffee also appeared as a new behavior characteristic in parks. Third, the factors affecting the behavior of park users are the changes of various conditions of society such as internet development and a culture of expressing unique personalities and styles. Fourth, the special behaviors appearing at Olympic Park were derived from educational activities such as cultural activities including watching performances and history lessons. In conclusion, it has been shown that people's lifestyle changes and the behavior of a park are influenced by the changes of the various times rather than the original purpose that was intended during park planning and design. Therefore, it is necessary to create an environment tailored to users by considering the main behaviors and influencing factors of Olympic Park. Text mining used as an analytical method has the merit that past data can be collected. Therefore, it is possible to form analysis from a long-term viewpoint of behavior analysis as well as to measure new behavior and value with derived keywords. In addition, the validity of online data was verified through social network analysis to increase the legitimacy of research results. Research on more comprehensive behavior analysis should be carried out by diversifying the types of data collected later, and various methods for verifying the accuracy and reliability of large-volume data will be needed.

Reaction Mechanism and Curing Characteristics of Chicken Feather-Based Adhesives and Adhesive Properties of Medium-Density Fiberboard Bonded with the Adhesive Resins (닭털로 제조한 접착제의 반응기작 및 경화 특성과 이를 이용하여 제조한 중밀도섬유판의 접착 특성)

  • Yang, In;Park, Dae-Hak;Choi, Won-Sil;Oh, Sei Chang;Ahn, Dong-uk;Han, Gyu-Seong
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.385-394
    • /
    • 2017
  • In this study, reaction mechanism and curing characteristics of adhesives formulated with NaOH- and $H_2SO_4$-hydrolyzed chicken feather (CF) and formaldehyde-based crosslinkers were investigated by FT-IR and DSC. In addition, adhesive properties and formaldehyde emission of medium-density fiberboards (MDF) applied with the adhesives were measured. CF-based adhesives having a solid content of 40% and over were very viscous at $25^{\circ}C$, but the viscosity reduced to $300{\sim}660m{\cdot}Pa{\cdot}s$ at $50^{\circ}C$. Consequently, the adhesives could be used as a sprayable resin. Through the FT-IR spectra of liquid and cured CF-based adhesives, addition reaction of methylol group and condensation reaction between the functional groups with the use of formaldehyde-based crosslinkers were identified. From the analysis of DSC, it was elucidated for CF-based adhesives to require a higher pressing temperature or longer pressing time comparing to commercial urea-formaldehyde (C-UF) resin. MDF bonded with CF-based adhesives, which was formulated with 5% NaOH-hydrolyzed CF (CF-AK-5%) and PF of formaldehyde to phenol mole ratio of 2.5 (PF-2.5), and pressed for 8 min had higher MOR and IB than those with other CF-based adhesives. MOR and IB of MDF bonded with the CF-based adhesives regardless of formulation type and pressing time were higher than those with C-UF resin. When the values compared with the minimum requirements of KS standard, IB exceeded the KS standard in all formulations and pressing time, but MOR of only MDF bonded with CF-AK-5% and PF-2.5 and pressed for 8 min satisfied the KS standard. What was worse, 24-TS of MDF bonded with all CF-based adhesives did not satisfied the KS standard. However, MOR and 24-TS can be improved by increasing the target density of MDF or the amount of wax emulsion, which is added to improve the water resistance of MDF. Importantly, the use of CF-based adhesives decreased greatly the formaldehyde emission. Based on the results, we reached the conclusion that CF-based adhesives formulated under proper conditions had a potential as a sprayable resin for the production of wood panels.

Development of the Monte Carlo Simulation Radiation Dose Assessment Procedure for NORM added Consumer Adhere·Non-Adhere Product based on ICRP 103 (ICRP 103 권고기반의 밀착형·비밀착형 가공제품 사용으로 인한 몬테칼로 전산모사 피폭선량 평가체계 개발)

  • Go, Ho-Jung;Noh, Siwan;Lee, Jae-Ho;Yeom, Yeon-Soo;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.124-131
    • /
    • 2015
  • Radiation exposure to humans can be caused by the gamma rays emitted from natural radioactive elements(such as uranium, thorium and potassium and any of their decay products) of Naturally Occurring Radioactive Materials(NORM) or Technologically Enhanced Naturally Occurring Radioactive Materials(TENORM) added consumer products. In this study, assume that activity of radioactive elements is $^{238}U$, $^{235}U$, $^{232}Th$ $1Bq{\cdot}g^{-1}$, $^{40}K$ $10Bq{\cdot}g^{-1}$ and the gamma rays emitted from these natural radioactive elements radioactive equilibrium state. In this study, reflected End-User circumstances and evaluated annual exposure dose for products based on ICRP reference voxel phantoms and ICRP Recommendation 103 using the Monte Carlo Method. The consumer products classified according to the adhere to the skin(bracelet, necklace, belt-wrist, belt-ankle, belt-knee, moxa stone) or not(gypsum board, anion wallpaper, anion paint), and Geometric Modeling was reflected in Republic of Korea "Residential Living Trend-distributions and Design Guidelines For Common Types of Household.", was designed the Room model($3m{\times}4m{\times}2.8m$, a closed room, conservatively) and the ICRP reference phantom's 3D segmentation and modeling. The end-user's usage time assume that "Development and Application of Korean Exposure Factors." or conservatively 24 hours; in case of unknown. In this study, the results of the effective dose were 0.00003 ~ 0.47636 mSv per year and were confirmed the meaning of necessary for geometric modeling to ICRP reference phantoms through the equivalent dose rate of belt products.

Preparation and Properties of Eco-friendly Waterborne Polyurethane-urea Primer for Thermoplastic Polypropylene Applied to Automobile Interiors (자동차 내장재용 열가소성 폴리프로필렌에 적용되는 선처리제용 친환경 수분산 폴리우레탄-우레아의 제조 및 성질)

  • Shin, Jong Sub;Park, Jin Myeong;Lee, Young Hee;Kim, Han Do
    • Clean Technology
    • /
    • v.20 no.3
    • /
    • pp.232-240
    • /
    • 2014
  • The significance of thermoplastic polyolefin polypropylene (PP) lies in its potential to replace polyvinyl chloride (PVC), the most widely used material for automobile interiors (door trim, dash board), which discharges harmful compounds in certain conditions. Another benefit of PP (0.855 amorphous - 0.946 crystalline $g/cm^3$) is its low density compared to that of PVC ($1.1-1.45g/cm^3$), which reduces vehicle weight. Market demand for eco-friendly water-based adhesive/coating material is rising significantly as a substitute for solvent-based adhesive/coating material which emits VOC and causes harmful working conditions. Under such context, in this study, a series of eco-friendly waterborne polyurethane-urea primer (a paint product that allows finishing paint to adhere much better than if it were used alone) for hydrophobic PP were prepared from different mix of DMPA content, NCO/OH molar ratio, various wt% of silicone diol and various soft segment content, among which DMPA of 21 mole %, NCO/OH molar ratio of 1.2, modified silicone diol of 5 wt% and soft segment content of 73 wt% led to good adhesion strength. Additionally, the incorporation of optimum content of additives (0.5 wt% dispersing agent, 0.5 wt% levelling agent, 1.5 wt% antifoaming agent, 3.0 wt% matting agent) into the optimum waterborne polyurethane-urea also enabled good stability, levelling, antifoaming and non-glossy.

Effects of Pretreatment and Chemical Additives on Wood Cement Board Qualities from Larix leptolepis Grown in Korea (한국(韓國) 낙엽송재(落葉松材)의 목질(木質)세멘트판(板) 재질(材質)에 미치는 전처리(前處理) 및 첨가제(添加劑) 효과(效果))

  • Park, Jong Young;Lee, Hwa Hyung
    • Korean Journal of Agricultural Science
    • /
    • v.9 no.1
    • /
    • pp.250-259
    • /
    • 1982
  • The Larch was known unsuitable species for the wood cement board owing to its some inhibitory substances. Therefore this research was carried out to evaluate the effect of pretreatments and chemical additives on the properties of woodflake cement board from Japanese larch (Larix leptolepis) grown in Korea. In order to improve the board qualities, the woodflakes were treated by cold water or dilute NaOH solutions(0.1, 0.5, and 2.0%), and also some chemicals($CaCl_2$, $Al_2Cl_3$ and $Na_2SiO_4$) added to the wood cement mixture. The results obtained are summarized as follow; 1. The wood cement boards from the woodflake treated with 0.1% NaOH showed remarkable higher bending strengths and internal bonding strengths than those from the flake pretreated with cold water. 2. The bending strengths showed over $60kg/cm^2$, i.e. the standard strength of JIS A-5417, with pretreatments of NaOH over 0.1% and additive of $CaCl_2$ 3.0%. The maximum strengths showed at about 0.5 of every additives. 3. Addition of $CaCl_2$ and $Al_2Cl_3$, in the case of pretreated wood with NaOH above 0.1%, had effects on increasing the internal bonding strengths of sample boards. 4. The thickness swellings became decreasing along with the increasing NaOH pretreatment concentntration. 5. The equilibrium conditions of the sample boards pretreated with NaOH over 0.1% and added with $Al_2Cl_3$ and $CaCl_2$ were maintained at 9.0~10.5% moisture contents. 6. The specific gravity of the samples showed close relationships with strength properties.

  • PDF