• Title/Summary/Keyword: 병소

Search Result 789, Processing Time 0.024 seconds

An Elimination of False-Positive I-131 Sites in Esophagus for Thyroid Carcinoma; Using Water with Vitamin C Dissolved (갑상선암의 방사성옥소 치료 후 전신 스캔에서 비타민C 용액을 이용한 식도의 위양성 병소 제거에 대한 고찰)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sa-Ron;Cho, Seok-Won;Choi, Young-Sook;Cho, Arther;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.49-56
    • /
    • 2008
  • Purpose: Whole body imaging with radioiodine can detect functioning metastases. Non-physiologic I-131 uptake detected on images usually is interpreted as suggesting functioning thyroid metastases. However, extra-thyroidal I-131 accumulation does not always imply thyroid cancer metastases and has been reported in many circumstances. In order to avoid unnecessary therapeutic interventions it is important to distinguish false-positive sites of I-131 localization. We study here to remove false-positive sites around esophagus region on I-131 whole body imaging in patients who were administrated thyroidectomy. Materials and Methods: From April to August in 2007, we had the patients who had visited our department after they received thyroidectomy due to thyroid cancer. They were given I-131, and performed radioiodine body scan after 41 to 50 hours. Patients were whole-body-scanned for the speed of 8 cm per minute. After that, we took anterior and posterior static images around the patients' neck measured by 300 thousand counts per image. We selected 44 patients who had hot spots around neck region, we divided the patients into two groups. One group was given 0.5 L of water and the other group was given 0.5 L of water with 1 g of Vitamin C dissolved. The patients were asked to drink the fluid for one minute in sitting position and after that, we measured 300 kilo counts per image again. We compared prior anterior, posterior static images with anterior, posterior images after the patients had water or water that Vitamin C resolved. Results: In using water, both observer 1 and 2 interpreted 6 patients were washed out. In the water with Vitamin C resolved, observer 1 and 2 interpreted 9 and 8 patients were washed out. Observer 1 and 2 interpreted 6 and 5 patients had 'indeterminate' when they used water. Both observer 1 and 2 interpreted 6 patients had 'indeterminate' when they used water with Vitamin C resolved. When they used water, observer 1 interpreted 10 patients had 'unchanged' and observer 2 interpreted 11 patients had 'unchanged'. Differently, when they used water with vitamin C resolved, observer1 had 8 patients having 'unchanged'and observer 2 had 9. Conclusion: As a result, by making patients drink 0.5 liter of water which has vitamin C resolved helped getting rid of false-positive sites in esophagus. Therefore, based on this study, we believe that drinking water with vitamin C dissolved is very in terms of reducing false-positive hot spot around the esophagus for the iodine-131 whole body scan.

  • PDF

Radiotherapy for Oral Cavity Cancer (구강암의 방사선치료)

  • Shim Jae Won;Yoo Seong Yul;Koh Kyoung Hwan;Cho Chul Koo;Yun Hyong Geun;Kim Jae Young
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.267-275
    • /
    • 1993
  • Eighty five patients of oral cavity cancer, treated with radiation at the Department of Therapeutic Radiology, Korea Cancer Center Hospital, during the period from March 1985 to September 1990 were analyzed retrospectively. Among 85 patients, 37 patients were treated with radiation only and 48 patients were treated with radiation following surgery. And 70 patients received external irradiation only by $^{60}Co$ with or without electron, the others were 7 patients for external irradiation plus interstitial implantation and 8 patients for external irradiation plus oral cone electron therapy. Primary sites were mobile tongue for 40 patients, mouth floor for 17 patients, palate for 12 patients, gingiva including retromolar trigone for 10 patients, buccal mucosa for 5 patients, and lip for 1 patient. According to pathologic classification, squamous cell carcinoma was the most common (77 patients). According to AJC TNM stage, stage I + II were 28 patients and stage III+IV were 57 patients. Acturial overall survival rate at 3 years was $43.9\%,$ 3 year survival rates were $60.9\%$ for stage I + II, and $23.1\%$ for stage III+IV, respectively. As a prognostic factor, primary T stage was a significant factor (p<0.01). The others, age, location, lymph node metastasis, surgery, radiation dose, and cell differentiation were not statistically significant. Among those factors, radiation plus surgery was more effective than radiation only in T3+T4 or in any N stage although it was not statistically sufficient (p<0.1). From those results, it was conclusive that definitive radiotherapy was more effective than surgery especially In the view of pertainig of anatomical integrity and function in early stage, and radiation plus surgery was considered to be better therapeutic tool in advanced stage.

  • PDF

The Role of Radiation Therapy in the Treatment of Intracranial Glioma : Retrospective Analysis of 96 Cases (뇌 교종 96예에 대한 방사선치료 성적의 후향적 분석)

  • Kim Yeon Sil;Kang Ki Mun;Choi Byung Ock;Yoon Sei Chul;Shinn Kyung Sub;Kang Jun Gi
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.249-258
    • /
    • 1993
  • Between March 1983 and December 1989, ninety-six patients with intracranial glioma were treated in the Department of Therapeutic Radiology, Kangnam St. Mary's Hospital, Catholic University Medical College. We retrospectively reviewed each case to evaluate variable factors influencing the treatment results and to develop an optimal therapy Policy. Median follow-up is 57 months (range: 31~133 months). Of the 96 patients, 60 $(63\%)$ were males and 36 $(37\%)$ were females. Ages ranged from 3 to 69 years (median 42 years). The most common presenting symtoms were headeche $(67\%)$ followed by cerebral motor and sensory discrepancy $(54\%),$ nausea and vomiting $(34\%),$ seizure $(19\%),$ mental change $(10\%)$ and memory and calculation impairment $(8\%).$ Eighty five $(88.5\%)$ patients all, except 11 $(11.5\%)$ brain stem lesions, were biopsy proven intracranial glioma. The distribution by histologic type was 64 astrocytomas $(75\%),$ 4 mixed oligoastrocytomas $(5\%),$ and 17 oligodendrogliomas $(20\%).$ Fourty nine patients $(58\%$ were grade I, II histology and 36 $(42\%)$ patients were grade III, IV histology. Of the 96 patients, 64 $(67\%)$ recieved postoperative RT and 32 $(33\%)$ were treated with primary radiotherapy. Gross total resection was peformed in 14 $(16\%)$ patients, subtotal resection En 29 $(34\%),$ partial resection in 21 $(25\%),$ and biopsy only in 21 $(25\%).$ Median survival time was 53 months (range 2~ 133 months), and 2- and, 5-year survival rate were $69\%,49\%$ respectively. 5-year survival rate by histologic grade was grade I, $70\%,$ grade II, $58\%,$ grade III, $28\%,$ and grade IV, $15\%.$ Multivariated analysis demonstrate that age at diagnosis (p=0.0121), Karnofsky performance Status (KPS) (p=0.0002), histologic grade (p=0.0001), postoperative radiation therapy (p=0.0278), surgical extent (p =0.024), cerebellar location of tumor (p=0.0095) were significant prognostic factors influencing on survival.

  • PDF

Evaluation of Electron Boost Fields based on Surgical Clips and Operative Scars in Definitive Breast Irradiation (유방보존술 후 방사선치료에서 수술 흉터와 삽입된 클립을 이용한 전자설 추가 방사선 조사야 평가)

  • Lee, Re-Na;Chung, Eun-Ah;Lee, Ji-Hye;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.236-242
    • /
    • 2005
  • Purpose: To evaluate the role of surgical clips and scars in determining electron boost field for early stage breast cancer undergoing conserving surgery and postoperative radiotherapy and to provide an optimal method in drawing the boost field. Materials and Methods: Twenty patients who had $4{\sim}7$ surgical clips in the excision cavity were selected for this study. The depth informations were obtained to determine electron energy by measuring the distance from the skin to chest wall (SCD) and to the clip implanted in the most posterior area of tumor bed. Three different electron fields were outlined on a simulation film. The radiological tumor bed was determined by connecting all the clips implanted during surgery Clinical field (CF) was drawn by adding 3 cm margin around surgical scar. Surgical field (SF) was drawn by adding 2 cm margin around surgical clips and an Ideal field (IF) was outlined by adding 2 cm margin around both scar and clips. These fields were digitized into our planning system to measure the area of each separate field. The areas of the three different electron boost fields were compared. Finally, surgical clips were contoured on axial CT images and dose volume histogram was plotted to investigate 3-dimensional coverage of the clips. Results : The average depth difference between SCD and the maximal clip location was $0.7{\pm}0.55cm$. Greater difference of 5 mm or more was seen in 12 patients. The average shift between the borders of scar and clips were 1.7 1.2, 1.2, and 0.9 cm in superior, inferior, medial, and lateral directions, respectively. The area of the CF was larger than SF and IF in 6y20 patients. In 15/20 patients, the area difference between SF and if was less than 5%. One to three clips were seen outside the CF in 15/20 patients. In addition, dosimetrically inadequate coverage of clips (less than 80% of prescribed dose) were observed in 17/20 patients when CF was used as the boost field. Conclusion: The electron field determined from clinical scar underestimates the tumor bed in superior-inferior direction significantly and thereby underdosing the tissue at risk. The electron field obtained from surgical clips alone dose not cover the entire scar properly As a consequence, our technique, which combines the surgical clips and clinical scars in determining electron boost field, was proved to be effective in minimizing the geographical miss as well as normal tissue complications.

Surgical Treatment of Ventricular Tachycardia After Total Correction of Tetralogy of Fallot- Report of a case (TOF 완전교정술후 발생한 심실빈맥의 외과적 절제술 -치험1례보고-)

  • 장병철;김정택
    • Journal of Chest Surgery
    • /
    • v.29 no.6
    • /
    • pp.639-645
    • /
    • 1996
  • A 14-year-old male patient with previous surgical repair of tetralogy of Fallot was admitted with hemodynamically significant ventricular tachycardia (VT). On preoperative electrophysiologic study (EPS), the morphology of documented VT was RBBB of vertical axis with 320 msec cycle length. The endocardial mapping during VT delineated the origin of VT at right ventricular outflow tract (RVOT), where the patch was attached. The clinical VT had a clockwise reentry circuit around the patch with the earliest activation at the same site seen during the preoperative EPS. The previously placed right ventricular outflow patch and fibrous tissue were removed. During a postoperative EPS, it was no longer possible to induce the VT. Ventricular tachycardia following repair of tetralogy of Fallot seen in this patient was caused by a macro-reentry around the right ventricular outflow patch. We were able to ablate the VT with the aid of a detailed mapping of its epicardial activation sequence.

  • PDF

Assessment of the Synovial Inflammation in Rheumatoid Arthritis with $^{99m}Tc$-labelled Polyclonal Human IgG(HIG): Prospective Comparison with Gadolinium Enhanced MRI ($^{99m}Tc$-labelled HIG 스캔을 이용한 류마티스 관절염 환자에서 활막염증의 평가 : 조영증강 자기공명영상과의 전향적인 비교)

  • Ryu, Young-Hoon;Lee, Jong-Doo;Suh, Jin-Suck;Park, Chang-Yun;Jeon, Pyoung;Na, Jae-Beom;Lee, Soo-Kon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.84-91
    • /
    • 1995
  • Many clinical and laboratory tests have been employed to evaluate disease activity in rheumatioid arthritis. $^{99m}Tc$-labelled polyclonal IgG(HIG) has been demonstrated to accumulate in focal sites of infection or inflammation in both animals and human subjects. The purpose of this study was to distinguish arthritis with active inflammation from those without active inflammation and to correlate relative intensities of $^{99m}Tc$-labelled HIG uptake of the rheumatoid arthritis with clinical and MR indices of the joint inflammation. This study included twelve patients with active rheumatoid arthritis, two with ankylosing spondylitis and one with degenerative osteoarthritis without active inflammation. A Whole-body and spot images were obtained 4 hours after intravenous injection of 20mCi of $^{99m}Tc$-labelled HIG. Scintigrams were assessed visually by 3 experienced radiologists, and graded as normal or mildly and markedly increased uptake within the joints, and the degree of uptake was compared with clinical and radiologic severity of synovial inflammation. MRI studies were done on the involved joints consisted of wrist(n = 11), knee(n = 2) and hip joint(n= 2). Active synovitis was defined when marked elevation of ESR and gadolinium enhancement of synovium on MRI were demonstrated. Markedly increased radiotracer uptake was seen in 10 of 11 rheumatoid arthritic patients with active synovitis whereas normal or mildly increased uptakes were noted in others, including rheumatoid arthritic patient(n=1) and non-rheumatoid patients(n = 3) without active synovitis. This study showed that the localization of involved joints in rheumatoid arthritis could be detected with $^{99m}Tc$-labelled HIG and that the degree of uptake correlated well with the degree and activity of inflammation. In conclusion, $^{99m}Tc$-labelled HIG scan is a useful method in the evaluation of active inflammation in rheumatoid arthritis.

  • PDF

Parametric Images of Standardized Uptake Values using P-18-FDG Attenuation Corrected Whole Body PET (F-18-FDG감쇠보정 전신 PET을 이용한 표준섭취계수 추정과 매개변수 영상의 구성)

  • Kim, Kyeong-Min;Kwark, Cheol-Eun;Lee, Dong-Soo;Jeong, Jae-Min;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Kim, Yong-Jin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.560-569
    • /
    • 1996
  • Background and Purpose : Standardized uptake value(SUV) has been used as a quantitative index for differentiating benign and malignant tumors with F-18-FDG PET In this study, we produced whole body parametric images of SUV(WBPIS) by body weight normalization, and validated the values by comparison with SUV's calculated with regional scans. Subjects and Methods : Whole body scans were followed by regional scans sequentially on 23 patients. In whole body study, transmission and emission scans were acquired for 2 minutes and 6 minutes for each bed position, respectively. In regional study, transmission and emission scans were acquired for 20 minutes. Measured and segmented/ smoothed attenuation correction were applied using these 2 min transmission scans in whole body studies. The effects of attenuation correction on SUVs were evaluated quantitatively using F-18 filled cylindrical phantom. The mean and peak SUVs obtained from WBPIS were compared with SUVs of the regional scans. Results : In phantom studies, with any method of attenuation correction using regional or whole body studies of phantom, SUVs were nearly consistent. In whole body scan, SUV obtained using measured attenuation correction method was a little higher than SUV of regional scan. SUV obtained using segmented/smoothed attenuation correction method was a little lower. In patient studies, WBPIS using segmented/smoothed attenuation correction method was much smoother and more readable. SUVs of WBPIS obtained with both methods of attenuation correction were well correlated with SUVs of regional scans(r=0.9). SUVs of WBPIS with measured attenuation correction method were 5% lower than SUVs of regional scans. SUVs of WBPIS with segmented/smoothed attenuation correction method were 10% lower than SUVs of regional scans. The differences of SUVs of WBPIS by the two attenuation correction methods were relatively small compared with the possible differences derived from biological characteristics of tumors. Conclusion : We concluded that WBPIS could be useful in the quantification of tumor as well as in localization of whole body lesions, which were often outside the field of view in regional scan. WBPIS made using segmented/smoothed attenuation correction method could be used in clinical routines and SUVs from attenuation corrected F-18-FDG PET could be used interchangeably with SUVs of regional studies.

  • PDF

The Usefulness Assessment of Attenuation Correction and Location Information in SPECT/CT (SPECT/CT에서 감쇠 보정 및 위치 정보의 유용성 평가)

  • Choi, Jong-Sook;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.214-221
    • /
    • 2008
  • Purpose: We make a qualitative analysis of whether Fusion SPECT/CT can find lesion's anatomical sites better than existing SPECT or not, and we want to show the usefulness of SPECT/CT through finding out effects of CT attenuation correction on SPECT images. Materials and Method: 1. The evaluation of fusion images: This study comprised patients who was tested $^{131}I$-MIBG, Bone, $^{111}In$-Octreotide, Meckel's diverticulum, Parathyroid MIBI with Precedence 16 or Symbia T2 from 2008 Jan to Aug. We compared SPECT/CT image with non fusion image and make a qualitative analysis. 2. The evaluation of attenuation correction: We classified 38 patients who was tested 201Tl myocardial exam with Symbia T2 into 5 sections by using Cedars Sinai' QPS program - Ant, Inf, Lat, Septum, Apex. And we showed each section's perfusion states by percentage. We compared the each section's perfusion-states differences between CT AC and Non AC by average${\pm}$standard deviation. Results: 1. The evaluation of fusion images : In high energy $^{131}I$ cases, it was hard to grasp exact anatomical lesions due to difference between regions and surrounding lesions' uptake level. After combining with CT, we could grabs anatomical lesion more exactly. And in meckel's diverticulum case or to find lesions around bowels or organs with $^{111}In$ cases, it demonstrates its superiority. Bone SPECT/CT images help to distinguish between disk spaces certainly and give correct results. 2. The evaluation of attenuation correction: There is no significant difference statistically in Ant and Lat (p>0.05), but there is a meaningful difference in Inferior, Apex and Septum (p<0.05). AC perfusion at inferior wall in the 5 sections of myocardium: The perfusion difference between Non AC perfusion image ($68.58{\pm}7.55$) and CT corrected perfusion image ($76.84{\pm}6.52$) was the largest by $8.26{\pm}4.95$ (p<0.01, t=10.29). Conclusion: Nuclear medicine physicians can identify not only molecular image which shows functional activity of lesions but also anatomical location information of lesions with more accuracy using the combination of SPECT and CT systems. Of course this combination helps nuclear medicine physician find out the abnormal parts. Moreover combined data sets help separate between normal group and abnormal group in complicated body part. So clinicians can carry out diagnosis and treatment planning at the same time with a single test image. In addition, when we examine a myocardium in thorax where attenuation can occur easily, we can trust perfusion more in a certain region in SPECT test because CT provides the capability for accurate attenuation correction. In these reasons, we think we can prove the justice after treatment fusion image.

  • PDF

Clinical Outcome of Pulmonary Metastasectomy in Patients with Pulmonary Metastasis (전이성 폐암에 대한 폐절제술의 성적)

  • Lee, Young-Ok;Lee, Eung-Bae;Ryu, Kyoung-Min
    • Journal of Chest Surgery
    • /
    • v.40 no.10
    • /
    • pp.674-679
    • /
    • 2007
  • Background: Surgical resection is accepted widely as the standard therapy for complete resectable pulmonary metastases. The number of cases of pulmonary metastasectomy and its survival rate is increasing due to the development of the therapeutic modalities. We attempted to analyze the survival rate and prognosis factors of pulmonary metastasectomy during the last 10 years. Material and Method: We retrospectively analyzed the data of 89 patients who underwent 96 procedures of pulmonary metastasectomy between January 1996 and December 2005. The factors that may influence the long term prognosis such as completeness of resection, the type of primary cancer, the disease-free interval, the number and size of metastasis and the laterality were investigated. Result: There was no operative mortality. The mean disease free interval (DFI) was $29.6{\pm}27.9$ months and there were 3 cases of synchronous metastasis (3.4%). The overall 3, 5 and 10 year survival rate was 52.5%, 32.1% and 20.7%, respectively. The median survival time was 38 months. The 5-year survival rate according to the IRLM appraisal was 63.5%, 33.3%, 22.1% and 0% for stage I, II, III and IV, respectively Univariate analysis showed a better prognosis for patients with a disease free interval of 36 months or more, unilateral metastasis and 4 or less metastases. Conclusion: The survival rate for completely resectable pulmonary metastasectomy was favorable. The disease free interval, laterality and the number of metastasis were the prognosis factors.

Longitudinal Study of the Subgingival Microbial Change after Tetracycline Topical Application (Tetracycline 국소도포가 치은연하 세균분포에 미치는 영향)

  • Choi, Kwang-Choon;Lee, Young-Hee;Lee, Jin-Yong;Chung, Chong-Pyoung;Son, Seong-Heui
    • The Journal of the Korean Society for Microbiology
    • /
    • v.21 no.4
    • /
    • pp.503-513
    • /
    • 1986
  • Previous studies have developed the technique of topical application of tetracycline(TC) into the periodontal pockets and examined the change of clinical parameters and subgingival microbial morphotypes. The purpose of this study was to longitudinally examine the clinical and microbiological effects of topically applied TC in a double-blind and split-mouth design. Thirteen patients with moderate periodontitis, who were treated with or without TC application and scaling treatment, were examined. TC gel(3%) was used to apply into the selected periodontal pockets twice a week for 2 weeks. During the experiment, clinical parameters and subgingival microbial morphotypes were examined, and for isolation of black-pigmented Bacteroides(BPB) and streptococci, an anaerobic sample culturing was done at week 0, 2, and 7. In clinical observation the TC-scaled group exhibited a significant decrease of Gingival Inflammatory Index, Plaque Index, Sulcus Bleeding Index, pocket depth, and gingival crevicular fluid when compared to the TC-unsealed, placebo-scaled, and placebo-unsealed groups. The result of microbial morphotype observation showed a significant increase of coccal form and a decrease of spirochetes in the TC-scaled, TC-unscaled, and placebo-scaled groups. The culture study of streptococci revealed that TC with scaling treatment resulted in a significant increase of S. sanguis I at week 2, but its proportion had returned to the base line level. The anaerobic culture study showed that BPB was significantly reduced in the TC-scaled and TC-unsealed groups at week 7. Among BPB species, B. intermedius declined significantly with time treatment(week 2 and 7) in the TC-scaled and TC-unsealed groups. These results suggest that the settled pathogenic microflora can be succeeded by nonpathogenic microflora in periodontal pockets after TC treatment.

  • PDF