• Title/Summary/Keyword: 병소

Search Result 789, Processing Time 0.033 seconds

REMINERALIZATION EFFECT OF INTERPROXIMAL CARIES ADJACENT TO GLASS IONOMER RESTORATIONS: IN VITRO STUDY USING QLF (QLF(Quantitative light-induced fluorescence)를 이용한 글라스 아이오노머 수복물의 인접면 우식 재광화 효과에 관한 연구)

  • Lee, Hyeok-Sang;Hyun, Hong-Keun;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.3
    • /
    • pp.244-249
    • /
    • 2011
  • This in vitro study compared the remineralization of incipient interproximal caries in the presence of three glass ionomer cements(highly-filled glass ionomer cement, resin-modified glass ionomer cement, compomer) and a resin composite(control). Thirty-two extracted premolars were selected based upon the lack of any visible demineralization. The teeth were coated in a transparent acid resistant nail varnish leaving $3{\times}3$ mm square. The teeth were subjected to the demineralizing buffer for 3 days and quantitative light-induced fluorescence(QLF) images of the subjects were taken. Proximal restoration was simulated by placing tooth specimens and the various glass ionomer cements in closed containers with artificial saliva at $37^{\circ}C$ and pH 7.0 with constant circulation. Further QLF images were subsequently taken at 30, 60, and 90 days. The changes of mineral loss(${\Delta}Q$) were evaluated by QLF and the change of ${\Delta}Q$(${\Delta}{\Delta}Q$) were compared between groups in order to evaluate the effects of remineralization. All data were analyzed using ANOVA and the post-HOC Dunnett C multiple comparison test at p<0.05. While ${\Delta}Q$(changes of mineral loss) increased for all treatments, the increases for three glass ionomer groups were significantly higher than that for the resin group at first month period. As time went on, the amount of ${\Delta}{\Delta}Q$ decreased.

Evaluation of the Clinical Usefulness of the Xeniss Rapid TB kit for the Diagnosis of Tuberculosis (결핵진단에서 Xeniss Rapid TB kit의 임상적 유용성)

  • Park, Seung-Kyu;Lee, Woo-Chul;Hwang, Soo-Hee;Kwon, Eun-Si;Lee, Hung-Soon;Lee, Duk-Hyoung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.4
    • /
    • pp.389-400
    • /
    • 2002
  • Background : The rapid diagnostic tests for tuberculosis are needed to facilitate early treatment of tuberculosis and prevention of Mycobacterium tuberculosis transmission. The Xeniss Rapid TB kit is a rapid, card-based immunochromatographic test for the detection of antibodies directed against M. tuberculosis antigens including antigen 5(38-kDa antigen). The objective of this study was to evaluate the performance of the Xeniss Rapid TB kit for the diagnosis of active tuberculosis with serums from patients, asymptomatic healthy and close contact controls. Methods : 188 patients with active tuberculosis were tested; 177 with pulmonary tuberculosis(18 with combined pleurisy), and 11 with extrapulmonary tuberculosis. The control groups were composed of 82 close contacts and 57 healthy adults. Study subject were drawn from one national tuberculosis hospital for patients and close contacts, and another private hospital for healthy adults in Masan city, Korea. The Xeniss Rapid TB kit(Xeniss Life Science Co., Ltd., Seoul, Korea) was evaluated by using serum samples according to the instructions of the manufacturer by an investigator masked to the clinical and microbiological status of the study subjects. Results : The diagnostic sensitivity of the Xeniss Rapid TB kit was 73.9% in patients and specificities were 73.2% and 93.0% in close contact and healthy adults respectively. The positive predictive value in patients was 84.2% and the negative predictive value in controls was 85.8%. Conclusion : This study shows that the Xeniss Rapid TB test is a simple and fast method to diagnose active TB. The results of the sensitivity and specificites suggest that serodiagnosis using this point of care testing(POCT) device would be valuable and advantageous for screening tuberculosis in the clinical field.

The Effect of Platelet-Rich Plasma on Allograft Transplantation after Curettage in Benign Bone Tumor (양성 골 종양의 소파술 후 실시한 동종골 이식에서 혈소판 풍부 혈장 투여의 효과)

  • Kim, Jae-Do;Kim, Ji-Youn;Jang, Su-Jin;Chung, So-Hak;Jung, Gu-Hee
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.16 no.1
    • /
    • pp.8-13
    • /
    • 2010
  • Purpose: This study was performed to evaluate the effi ciency of Platelet-rich plasma (PRP) for acceleration of bone healing process on allograft transplantation after curettage in benign bone tumor. Materials and Methods: From December 2007 to February 2009, twenty-one patients who had benign bone tumor and underwent allograft transplantation after curettage were evaluated. Mean follow-up period was 14.6 months (range, 12-26 months). We compared with 13 cases of PRP group and 8 cases of non-PRP group in terms of size of lesion, bone resorption, amount of applied PRP and complications. The mean age at surgery was 23.6 years (range, 4-73 years). The most common diagnosis was simple bone cyst (7) followed by enchondroma (4), giant cell tumor (3), undifferentiated benign bone tumor (3) and so on. Results: The mean size of lesion was 33.5 $cm^3$ (range, 2.3-181.9 $cm^3$) (29.4 $cm^3$ in PRP group and 40.2 $cm^3$ in non-PRP group). The mean volume of injected PRP was 7.4 cc (range, 3-12 cc). Bone union started at 3.0 months (range, 1.5-5.8 months) in PRP group and 5.3 months (range, 4-8 months) in non-PRP group. Three cases for each group were excluded due to recurrence and pathologic fracture. One patient had febrile episode 3 weeks later after surgery which subsided with antibiotics. Conclusion: The PRP could accelerate bone union in allograft transplantation after curettage of benign bone tumor. Furthermore, we expect that PRP can accelerate bone union in fracture or non-union.

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF

Prophylactic and therapeutic studies on intestinal giant-cystic disease of the Israel carp caused by yhelohunellus kitauei I. Course of formation and vanishment of the cyst (향어의 장포자충(Thelohanellus kitauei)증의 예방 및 치료에 관한 기초적 연구 I . 종유의 소장 과정)

  • 이재구;김종오
    • Parasites, Hosts and Diseases
    • /
    • v.28 no.3
    • /
    • pp.183-194
    • /
    • 1990
  • In an attempt to develop prophylactic and therapeutic measures of the intestinal giant-cystic disease caused by Thelohanellus kitauei in the Israel carp, Cyprinus carpio nodus, pathological observations were conducted upon the carps which were hatched in May 1988 and raised in a net cage fish farm at the Soyang lake, managed by Horim Fisheries for the period of 21 months with 1~2 months interval. After a gross inspection of the carps, necropsy was carried out periodically in order to clarify the pathological changes in various internal organs and muscular tissues. Also. the prevalence of the disease was checked during the period from 1988 to 1990. Gross inspections revealed that the infected carps showed some degree of fading in body and gill color, back-emaciation symptoms, reddish anus accompanying erosion and relaxation and pot-belly, as well as discharge of yellowish white mucoid material from the anus. However, most carps died eventually of intestinal obstruction. Other significant necropsy fadings included cyst formation of various size in the intestinal mucosa, ascites, anemic condition through internal organs and muscular tissues, hyperemia and dilation of intestines with decreased tension, thinness and fragility, and full contents of semi-fluid or yellowish white mucoid material in the intestinal canals. Based on the morphological characteristics of the spores found in the cysts, parasitic location in the intestines, macro- and microscopic findings of the lesions, the parasites were identised as Thelohanellus kitauei Egusa os Nakajima, 1981. Although monthly changes of water temperature were distinct, the extrusion rates of the polar filaments of the spores stayed constant throughout the year with an exception of a lower rate in July, The lesions initiated from mucosa and submucosa in early July became large swellings and then complete mature (orms following the peracute course. From late August the upper cysts were gradually opened and most of the spores were dispersed from anus into the surrounding water through December but only a few lasted until next April. The cysts were completely recovered until next September. Comparing the incidence and prevalence of the disease by year tremendous infection and death rates were checked in the first prevalent year, 1988, but the rates were significantly decreased in the second year, and showed an almost normal status in the third year, 1990. As the above summarized results showed, the disease entity might come to an end in three years after the first prevalent year, however, the spores must be strictly prevented because they could be infective in the water for one year.

  • PDF

Preoperative Detection of Hepatic Metastases from the colorectal Cancers: Comparison of Dual-phase CT scan, Mn-DPDP enhanced MRI, and combination of CT and MRI (대장암의 간 전이 진단: 이중시기 CT, Mn-DPDP 조영증강 MRI, 그리고 CT-MRI 종합 판독의 비교)

  • Shin, Kyung-Min;Kim, Jong-Yeol;Choi, Gyu-Seok;Kim, Hye-Jeong;Lee, Jong-Min;Chang, Yong-Min;Kim, Yong-Seon;Kang, Duk-Sik;Ryeom, Hun-Kyu
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.2
    • /
    • pp.109-116
    • /
    • 2005
  • Purpose : To determine the usefulness of additional Mn-DPDP MRI for preoperative evaluation of the patients with colorectal cancers by comparison of dual-phase CT scan, Mn-DPDP enhanced MRI and combination of CT and MRI. Materials and Methods : Fifty-three colorectal cancer patients with 92 metastatic nodules underwent dualphase (arterial and portal) helical CT scan and Mn-DPDP MRI prior to surgery. The indication of MRI was presence or suspected of having metastatic lesions at CT scan and/or increased serum carcinoembryonic antigen (CEA) levels (10 ng/mL or more). The diagnosis was established by the combination of findings at surgery, intraoperative ultrasonography, and histopathologic examination. Two radiologists interpreted CT, MRI, and combination of CT-MRI at discrete sessions and evaluated each lesion for location, size, and intrinsic characteristics. The lesions were divided into three groups according to their diameter; 1cm<, 1-2 cm, and >2 cm. Diagnostic accuracy was evaluated using the alternative-free response receiver operating characteristic method. Detection and false positive rate were also evaluated. Results : In the lesions smaller than 1 cm, detection rate of combined CT-MRI was superior to CT or MRI alone (82%, p=0.036). The mean accuracy (Az values) of combined CT and MRI was significantly higher than that of CT in the lesions smaller than 2 cm (1 cm<, p=0.034; 1-2 cm, p=0.045). However, there was no significant difference between MRI and combined CT-MRI. The false positive rate of CT was higher than those of combined CT-MR in the lesions smaller than 1 cm (28%, p=0.023). Conclusion : Additional MRI using Mn-DPDP besides routine CT scan was helpful in differentiating the hepatic lesions (<2 cm) and could improve detection of the small hepatic metastases (<1 cm) from colorectal carcinoma.

  • PDF

Ictal Cerebral Perfusion Patterns in Partial Epilepsy: SPECT Subtraction (부분적 간질에서 SPECT Subtraction을 이용한 발작 중 뇌혈류 변화에 대한 연구)

  • Lee, Hyang-Woon;Hong, Seung-Bong;Tae, Woo-Suk;Kim, Sang-Eun;Seo, Dae-Won;Jeong, Seung-Cheol;Yi, Ji-Young;Hong, Seung-Chyul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.169-182
    • /
    • 2000
  • Purpose: To investigate the various ictal perfusion patterns and find the relationships between clinical factors and different perfusion patterns. Materials and Methods: Interictal and ictal SPECT and SPECT subtraction were performed in 61 patients with partial epilepsy. Both positive images showing ictal hyperperfusion and negative images revealing ictal hypoperfusion were obtained by SPECT subtraction The ictal perfusion patterns of subtracted SPECT were classified into focal hyperperfusion, hyperperfusion-plus, combined hyperperfusion-hypoperfusion, and focal hypoperfusion only. Results: The concordance rates with epileptic focus were 91.8% in combined analysis of ictal hyperperfusion and hypoperfusion images of subtracted SPECT, 85.2% in hyperperfusion images only of subtracted SPECT, and 68.9% in conventional ictal SPECT analysis. Ictal hypoperfusion occurred less frequently in temporal lobe epilepsy (TLE) than extratemporal lobe epilepsy. Mesial temporal hyperperfusion alone was seen only in mesial TLE while lateral temporal hyperperfusion alone was observed only in neocortical TLE. Hippocampal sclerosis had much lower incidence of ictal hypoperfusion than any other pathology. Some patients showed ictal hypoperfusion at epileptic focus with ictal hyperperfusion in the neighboring brain regions where ictal discharges propagated. Conclusion: Hypoperfusion as well as hyperperfusion in ictal SPECT should be considered for localizing epileptic focus. Although the mechanism of ictal hypoperfusion could be an intra-ictal early exhaustion of seizure focus or a steal phenomenon by the propagation of ictal discharges to adjacent brain areas, further study is needed to elucidate it.

  • PDF

Treatment of Articular Cartilage Defects of The Knee with Microfracture (미세 천공술을 이용한 슬관절 관절 연골 손상의 치료)

  • Shin, Sung-Il;Song, Kyoung-Won;Lee, Jin-Young;Lee, Seung-Yong;Kim, Gab-Lae;Hyun, Yoon-Suk;Seo, Eun-Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.205-210
    • /
    • 2008
  • Purpose: To evaluate the clinical results after microfracture surgery for full-thickness chondral lesion of the knee. Materials and Methods: Thrity-seven patients, who had underwent microfracture surgery for full-thickness chondral lesion of the knee between January 1999 and December 2005, were reviewed. Their mean age at the time of operation was 31 years (range, 21~38 years) and mean follow up period was 2.7 years. All patients were reviewd every 6 months after operation. Clinical outcomes were evaluated by activity of daily living (ADL), Tegner activity scale, International Knee Documentation Committee (IKDC) knee examination form, Lysholm score and satisfaction of treatment. Results: ADL and Tegner activity score improved in 83% of patients during first 18 months, but decreased during next 6months. IKDC score improved from 58 points at operation time to 86 points after 12 months, but decreased to 79 points and 68 points at 18 and 24 months after operation, respectively. Also, Lysholm score improved from 61 points at operation time to 89 points after 12 months, to 92 points after 18 months, but 73 points after 24 months. At the last follow-up, 22 patients were excellent or good in satisfaction of treatment, whereas 12 patients were fair, 3 patients were poor. Conclusion: Microfracture surgery for full-thickness chondral lesion of the knee has a good functional improvement for first 12 months after operation, but its effectiveness has decreased over time.

  • PDF

Evaluation of Average CT to Reduce the Artifact in PET/CT (PET/CT 검사에서 호흡에 따른 인공산물을 줄이기 위한 Average CT의 유용성)

  • Kim, Jung-Sun;Nam, Ki-Pyo;Park, Seung-Yong;Ryu, Jae-Kwang;Cha, Min-Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.3-7
    • /
    • 2010
  • Purpose: The usefulness of Positron Emission Tomography (PET) images in diagnosis, staging, recurrent and treatment response evaluation has already been known. However, tumors which are small size, located in lower lobe of lung or upper lobe of liver are shown misalignment, distortion and different Standard Uptake Value (SUV) by respiration in PET images. Therefore, if radiotherapy based on normal respiration, it may cause low treatment response or more side effects because targets which had to treat, out of treat range or over dose to normal tissue. The purpose of this study is to evaluate attenuation-correction with Average CT (ACT) for more accuracy SUV measurement and minimize artifact by respiration. Materials and Methods: 13 patients, who had tumors which are around the diaphragm, underwent ACT scan after Helical CT (HCT) scan with PET/CT (Discovery DSTE 8; GE Healthcare). We quantified the differences between attenuation corrected image with HCT and attenuation corrected image with ACT in artifact size and maximum SUV ($SUV_{max}$). Artifacts were evaluated by measurement of the curved photogenic area in the lower thorax of the PET images for all patients. $SUV_{max}$ was measured separately at the primary tumors. Analysis program was Advantage Workstation v4.3 (GE Healthcare). Patients were injected with 7.4 MBq (0.2 $mC_i$) per kg of $^{18}F$-FDG and scanned 1 hour after injection. The PET acquisition was 3 minute per bed. Results: Significantly lower artifact were observed in PET/ACT images than in PET/HCT images (below-thoracic artifacts caused by under corrected $1.5{\pm}3.5$ cm vs. $13.4{\pm}4.2$ cm). Significantly higher $SUV_{max}$ were noted in PET/ACT images than in PET/HCT images in the primary tumor. Compared with PET/HCT images, $SUV_{max}$ in PET/ACT images were higher by $5.3{\pm}3.9%$ (mean value) tumor. The highest difference was observed in Lower lobe of lung (7.7 to 8.7; 13%). Conclusion: Due to its significantly reduced artifacts in lower thoracic, attenuation corrected image with ACT images provided more reliable $SUV_{max}$ and may be helpful in monitoring treatment response. Moreover, ACT can separate upper lobe of liver and lower lobe of lung, it may be helpful in interpretation. ACT will be clinically useful, considering increased dose caused by ACT scan and adapt.

  • PDF

The Usefulness of Q.Clear Technique in PET / CT (PET/CT 검사에서 Q.Clear 기법의 유용성에 대한 고찰)

  • Choi, Yong Hoon;Kim, Jung Yul;Choi, Young Sook;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.31-36
    • /
    • 2017
  • Purpose Recently, the performance of PET/CT scanner has been improved and various techniques have been developed to increase the image quality such as Sensitivity and Resolution. The purpose of this study is to evaluate the usefulness of Q.Clear (a fully convergent iterative reconstruction) technique of GE Discovery IQ equipment to enhance the image quality. Materials and Methods All scans were acquired by Discovery IQ (GE Healthcare, MI, USA). In NEMA IEC Body Phantom test, Background to Hot-sphere (10 mm, 13 mm, 17 mm, 22 mm) ratio was 1:4 and scan time was 3 minutes. The images were reconstructed by VPHDs (VUE Point High-Definition + SharpIR) and Q.Clear to evaluate each Contrast. We injected 18F-FDG 187 M㏃ to PET/SPECT Performance Phantom. And then it was scanned for 4 minutes to evaluate Resolution and Uniformity. T-test statistical analysis was performed on SUVmax of small lesions less than 2 cm in 100 clinical patients regardless of disease type. Results In the NEMA IEC Body Phantom, the Contrast was $63.6{\pm}5.7%$ (VPHDs) and $75{\pm}4.8%$ (Q.Clear). In the PET/SPECT Performance Phantom, the Resolution was 9.2 mm (VPHDs) and 7.3 mm (Q.Clear). Uniformity of Q.Clear was 10.8% better than VPHDs. T-test statistic of the clinical patients showed a significant difference of p value of 0.021. Conclusion Both the phantom test and the clinical results showed that the quality of the image was improved in Q.Clear was applied. The SUVmax was highly measured in Q.Clear and the lesions were clearly distinguished visually. Therefore Q.Clear can be useful in various aspects such as dose-reduction, patients evaluation and image analysis.

  • PDF