• Title/Summary/Keyword: 병렬 배치

Search Result 108, Processing Time 0.021 seconds

Performance Evaluation of VBR MPEG Video Storage and Retrieval Schemes in a VOD System (VOD 시스템에서의 가변 비트율 MPEG 비디오 저장 및 검색 기법의 성능 평가)

  • 전용희;박정숙
    • Journal of Korea Multimedia Society
    • /
    • v.4 no.1
    • /
    • pp.13-28
    • /
    • 2001
  • In a VOD(Vide-On-Demand) system, video data are generally stored in magnetic disk array. In order to provide real-time requirement for data retrieval, video streams must be delivered continuously to the clients such that the delivery of continuous media can be guaranteed in a timely fashion. Compared to the increased performance of processors and networks, the performance of magnetic disk systems have improved only modestly. In order to improve the performance of storage system, disk array system is proposed and used. The array system improves I/O performance by placing disks in parallel and retrieving data concurrently. In this paper, two approaches are considered in order to access the video data in a VOD system, which are CTL(Constant Time Length) and CDL(Constant Data Length) access policies. Disk scheduling policies are also classified into the two categories and compared in terms of the maximum allowable video streams with different degrees of disk array synchronization, under the mixed environments in which both data access policy and disk scheduling policy are considered. Among the compared scheduling policies, LOOK was shown to have the best performance. In terms of degree of disk synchronization, more gain was achieved with large degree of synchronization. In comparisons of performance of CTL and CDL, CTL was proved to have a little superior performance in terms of number of maximum allowable streams.

  • PDF

Design of Binary Constant Envelope System using the Pre-Coding Scheme in the Multi-User CDMA Communication System (다중 사용자 CDMA 통신 시스템에서 프리코딩 기법을 사용한 2진 정진폭 시스템 설계)

  • 김상우;유흥균;정순기;이상태
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.5
    • /
    • pp.486-492
    • /
    • 2004
  • In this paper, we newly propose the binary CA-CDMA(constant amplitude CDMA) system using pre-coding method to solve the high PAPR problem caused by multi-user signal transmission in the CDMA system. 4-user CA-CDMA, the basis of proposed binary CA-CDMA system, makes binary output signal for 4 input users. It produces the output of binary(${\pm}$2) amplitude by using a parity signal resulting from the XOR operation of 4 users data. Another sub-channel or more bandwidth is not necessary because it is transmitted together with user data and can be easily recovered in the receiver. The extension of the number of users can be possible by the simple repetition of the basic binary 4-user CA-CDMA. For example, binary 16-user CA-CDMA is made easily by allocating the four 4-user CA-CDMA systems in parallel and leading the four outputs to the fifth 4-user CA-CDMA system as input, because the output signal of each 4-user CA-CDMA is also binary. By the same extension procedure, binary 64 and 256-user CA-CDMA systems can be made with the constant amplitude. As a result, the code rate of this proposed CA-CDMA system is just 1 and binary CA-CDMA does not change the transmission rate with the constant output signal(PAPR = 0 ㏈). Therefore, the power efficiency of the HPA can be maximized without the nonlinear distortion. From the simulation results, it is verified that the conventional CDMA system has multi-level output signal, but the proposed binary CA-CDMA system always produces binary output. And it is also found that the BER of conventional CDMA system is increased by nonlinear HPA, but the BER of proposed binary CA-CDMA system is not changed.

Determination on the component arrangement of a hybrid rain garden system for effective stormwater runoff treatment (강우유출수 처리를 위한 하이브리드 빗물정원 시스템의 구성요소 배열 연구)

  • Flores, Precious Eureka D.;Geronimo, Franz Kevin F.;Alihan, Jawara Christian P.;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.19 no.3
    • /
    • pp.271-278
    • /
    • 2017
  • Low impact development (LID) technology has been recently applied for the treatment of nonpoint source pollutants. Rain garden is one of the widely used LIDs since it utilizes various mechanisms such as biological and physico-chemical treatment to reduce pollutants. However, problem such as clogging has been one of the issues encountered by the rain garden that do not undergo constant maintenance. Therefore, this research was conducted to develop and determine the component arrangement of a rain garden system for a more efficient volume and pollutant reduction. Two hybrid rain garden systems having different characteristics were developed and evaluated to determine the optimum design and arrangement of the system. The results showed that the components arranged in a series manner showed a volume reduction of 93% and a pollutant reduction efficiency of approximately 99%, 93% and 95% was observed for particulates, nutrients and heavy metals, respectively. While when the system is connected in a combined series-parallel, the volume and average pollutant reduction efficiency for the TSS, nutrients and heavy metals are 65%, 94%, 80% and 85%, respectively. Moreover, the component arrangement in the order of sedimentation tank, infiltration tank and plant bed exhibited a high pollutant reduction efficiency compared when the infiltration tank and plant bed were interchanged. The findings of this research will help in the further development and optimization of rain garden systems.

Analysis on Multi-Components of Neurotransmitter Release in Response to Light of Retinal ON-Type Bipolar Cells (망막 ON형 쌍극세포의 광응답에 따른 다중성분의 전달물질 방출에 관한 해석)

  • Jung, Nam-Chae
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.4
    • /
    • pp.222-230
    • /
    • 2013
  • Retinal bipolar cells according to the light stimulus respond to potential slowly, emit neurotransmitter release(glutamine acid) to depend on membrane potential. In this paper, the several physiological information on neurotransmitter release mechanism in the presynaptic terminal of the ON-type bipolar cells are incorporated into the formula model. The source of fast components and slow components of neurotransmitter release was arranged in parallel, this model was able to reproduce the membrane potential and intracellular $Ca^{2+}$ concentration dependence of neurotransmitter release faithfully. In addition, because the fast releasable components of neurotransmitter was represented by the membrane potential dependence of trapezoid type, whereas the slow releasable components was represented by the membrane potential dependence of a bell type, $Ca^{2+}$ concentration rise in intracellular is suppressed by $Ca^{2+}$ buffer to reduce slow releasable components, it was confirmed that the membrane potential dependence of neurotransmitter release was characteristics of a trapezoid type. And, in the light response of ON type bipolar cell, the result of the simulation of the neurotransmitter release caused by the components of transient and persistent was that the start of light response occurred the fast release of neurotransmitter, it was confirmed that the transient component and persistent component of the light response occurred the slow release. It was confirmed that the later of persistent component of the light response occurred due to the continuous release by synaptic vesicle supplemented from the storage pool.

Robust Trajectory Tracking Control of a Mobile Robot Combining PDC and Integral Sliding Mode Control (PDC와 적분 슬라이딩 모드 제어를 결합한 이동 로봇의 강인 궤도 추적 제어)

  • Park, Min-soo;Park, Seung-kyu;Ahn, Ho-kyun;Kwak, Gun-pyong;Yoon, Tae-sung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.7
    • /
    • pp.1694-1704
    • /
    • 2015
  • In this paper, a robust trajectory tracking control method of a wheeled mobile robot is newly proposed combining the PDC and the ISMC. The PDC is a relatively simple and easy control method for nonlinear system compared to the other non-linear control methods. And the ISMC can have robust and stable control characteristics against model uncertainties and disturbances from the initial time by placing the states on the sliding plane with desired nominal dynamics. Therefore, the proposed PDC+ISMC trajectory tracking control method shows robust trajectory tracking performance in spite of external disturbance. The tracking performance of the proposed method is verified through simulations. Even though the disturbance increases, the proposed method keeps the performance of the PDC method when there is no disturbance. However, the PDC trajectory tracking control method has increasing tracking error unlike the proposed method when the disturbance increases.

Condenser Characteristics of Dielectric Soil Moisture Sensor (유전율 토양 수분 쎈서의 콘덴서 특성)

  • Oh, Yong-Taeg;Eorn, Ki-Cheol;Jo, In-Sang;Shin, Jae-Sung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.33 no.1
    • /
    • pp.15-23
    • /
    • 2000
  • RC oscillation method was applied to study the condenser characteristics of two metal sticks insulated by vinyl tube and used in the dielectric constant determinations of most soils. Its capacitance as influenced by the contacted ambient materials was measured as relative capacitance of the sensor sticks compared with the standard one on the RC oscillation circuit. According to the equivalent circuit of the sensor stick set, the measured capacitance was composed of a basic capacitance connected in parallel with sensor stick capacitance, which was composed of lineally connected vinyl tube capacitances and the sensing part capacitance. The dielectric constant (U) of the contacted ambient moist soil located in the sensing part around the sticks interrelated with the other parameters as following equation. $$\frac{1}{C-B}=\frac{k}{U}+Z$$ where C is the output total relative capacitance, B is the hidden and fixed basic relative capacitance, k is a constant related with U, and Z is a constant for the insulating vinyl tube capacitances determined by its thickness and dielectric constant. The constant k is determined by the spacing and length of sensor sticks. The Z value is theoretically an invariable constant, but it may become considerably bigger than the determined in lab if air tube is formed on the surface of sensor sticks by some shocks on them after their installation in soil. Due to the unstability of lab Z value, it may be better to revise it after sensor stick's installation in soil and no shaking shocks should be applied on them.

  • PDF

Generation of calibration standard gases using capillary gas divider: uncertainty measurement and method validation (다중 모세관을 이용한 교정용 표준가스의 제조: 불확도와 유효성 평가)

  • Lee, Sangyun;Hwang, Eun-Jin;Jung, Hye-Ja;Lee, Kwang-Woo;Chun, Ki-Joon
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.369-375
    • /
    • 2006
  • Calibration gas mixtures were prepared using dynamic volumetric method according to ISO 6145-5 and the uncertainty was evaluated. Ten identical capillaries with 0.25 mm in inner diameter and 50 cm in length were applied in this system. Dilution ratio of parent gas was determined by the number of capillaries that passes parent gas and that passes balance gas through. Capillaries were made of Teflon which had good chemical stability against adsorption of gaseous substances. Mechanical valves were introduced in this system in order to minimize the thermal effect of solenoid valves. Concentration of prepared gases were compared with master grade standard gases in cylinders made by RiGAS Co. and calibration of the instrument were completed using comparison method according to ISO 6143. Experimental results showed that the coefficient of variance of diluted oxygen standard gases showed less then 0.2% in most dilution range, that of diluted hydrogen sulfide standard gases showed less then 1.0%. Therefore, it is proven that the standard gases prepared by this system are appropriate to be used as a calibration standards in ambient monitoring, etc.

Assessment of the Activities of General Physicians in Health Subcenters and a Scheme to Improve the Training Program (보건지소 공중보건 일반의사의 업무수행정도와 수련개선방안)

  • Park, Jung-Han;Chun, Byung-Yeol;Woo, Kuck-Hyeun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.19 no.2 s.20
    • /
    • pp.193-202
    • /
    • 1986
  • The activities of general physicians (GPs) in health subcenters and their competency for clinical skills were assessed to develop a scheme to improve the training program. One hundred-twenty GPs in southern four provinces (Kyungpook, Kyungnam, Chunpook, Chunnam) were randomly selected and 97 were interviewed between January 9 and February 10, 1984. Of the 97 GPs, 86 provided all the information we requested. Average number of patient visits per health subcenter in a day was 30-40 in the demonstration project area for the class II medical insurance whereas it was 3-4 visits in other area. The interviewees were asked to rate their competency in 63 clinical skills. The skills in which over 50% of the interviewees rated themselves competent were only 12 items including IM injection, IV injection, wound dressing, etc. Less than 10% of the interviewees rated themselves competent in such skills as maternal health care, emergency medical care, preventive and promotive health services. Most part of the training program of the NIH for the GPs were not applicable to their field work as the training contents were unrealistic. Clinical training at a local general hospital was of great help in 38.8% and the rest of training was not much helpful as the training was inadequate due to lack of trainer or indifference of the trainer. For more effective training of the GPs, the training program of the NIH should be modified to be more realistic and utilize competent field workers as the instructors. It may be more effective if the training is carried out at several local centers. Ideal length of the clinical training for the GPs is 4 months. A pocketbook should be developed that includes specific skills to master during the clinical training and require the trainer to confirm the achievement. The Ministry of Health and Social Affairs should provide the training hospitals with a training guideline and evaluate the training activities and make sure that the training hospital has specialist for each of the 4 major clinical departments. The Ministry of Health and Social Affairs should provide the GPs with a continuing education to assist the problem solving in the field and motivate them to actively carry out the health program. A province may be divided into several regions and a supervisory committee may be organized with specialists in each region. The committee may hold a meeting for the GPs periodically and respond to the specific questions of the GPs by mail.

  • PDF