• Title/Summary/Keyword: 변환에너지

Search Result 2,541, Processing Time 0.032 seconds

Effect of Electrode Configuration on the Substrate Degradation in Microbial Fuel Cells (미생물연료전지에서 전극구조가 기질분해에 미치는 영향 연구)

  • Shin, Yujin;Lee, Myoung-Eun;Park, Chi-Hoon;Ahn, Yongtae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.8
    • /
    • pp.489-493
    • /
    • 2017
  • Microbial fuel cells (MFC) are bio-electrochemical processes that can convert various organic materials present in wastewater into electrical energy. For scaling-up and practical application of MFC, it is necessary to investigate the effect of anode size, electrode distance, and total area of anode on substrate degradation. Spaced electrode assembly (SPA) type microbial fuel cell with multiple anodes treating domestic wastewater was used for simulation. According to computer simulation results, the shorter the distance between electrodes than the size of single electrode, the faster the substrate degradation rate. Particularly, when the total area of the anode is large, the substrate decomposition is the fastest. In this study, it was found that the size of the anode and the distance between the electrodes as well as the cathode electrode, which is known as the rate-limiting step in the design of the microbial fuel cell process, are also important factors influencing the substrate degradation rate.

Characteristics Analysis of Induction Motor by Operation of Non-linear Loads under the 3-Phase 4-Wire Grid System (3상 4선식에시 비선형 부하의 운전시 유도전동기의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.8
    • /
    • pp.54-62
    • /
    • 2006
  • Voltage unbalance will be generated by the load unbalance operation such as combination operation of single & three phase load and current unbalance will be more severe by the deteriorated voltage quality. Under the these unbalance conditions, all power electronic converters used in different types of electronic systems can increase harmonic disturbances by injecting harmonic currents directly into the feeder grid of three phase 4-wire. Harmonic current may cause torque to decrease. it may also overheat or become noisy and torque oscillation in the rotor can lead to mechanical resonance and vibration. This paper presents a scheme on the characteristics of induction motor under the combination of linear & non-linear loads at the three phase 4-wire power distribution system by the unbalance and harmonic components. It was able to confirm that the number of torque pulsation decreased and torque ripple values increased by the harmonics that reduction was difficult by five harmonics filters at additional driving time of single-phase non-linear load.

A Study on Optimal Operation Method of Multiple Microgrid System Considering Line Flow Limits (선로제약을 고려한 복수개의 마이크로그리드 최적운영 기법에 관한 연구)

  • Park, Si-Na;An, Jeong-Yeol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.7
    • /
    • pp.258-264
    • /
    • 2018
  • This paper presents application of a differential search (DS) meta-heuristic optimization algorithm for optimal operation of a micro grid system. The DS algorithm simulates the Brownian-like random-walk movement used by an organism to migrate. The micro grid system consists of a wind turbine, a diesel generator, a fuel cell, and a photovoltaic system. The wind turbine generator is modeled by considering the characteristics of variable output. Optimization is aimed at minimizing the cost function of the system, including fuel costs and maximizing fuel efficiency to generate electric power. The simulation was applied to a micro grid system only. This study applies the DS algorithm with excellence and efficiency in terms of coding simplicity, fast convergence speed, and accuracy in the optimal operation of micro grids based on renewable energy resources, and we compared its optimum value to other algorithms to prove its superiority.

Fire-Flame Detection using Fuzzy Finite Automata (퍼지 유한상태 오토마타를 이용한 화재 불꽃 감지)

  • Ham, Sun-Jae;Ko, Byoung-Chul
    • Journal of KIISE:Software and Applications
    • /
    • v.37 no.9
    • /
    • pp.712-721
    • /
    • 2010
  • This paper proposes a new fire-flame detection method using probabilistic membership function of visual features and Fuzzy Finite Automata (FFA). First, moving regions are detected by analyzing the background subtraction and candidate flame regions then identified by applying flame color models. Since flame regions generally have continuous and an irregular pattern continuously, membership functions of variance of intensity, wavelet energy and motion orientation are generated and applied to FFA. Since FFA combines the capabilities of automata with fuzzy logic, it not only provides a systemic approach to handle uncertainty in computational systems, but also can handle continuous spaces. The proposed algorithm is successfully applied to various fire videos and shows a better detection performance when compared with other methods.

The Multi-legged Small Sized Robot Drive using Piezoelectric Benders (압전벤더를 이용한 소형 다족 로봇 구동원)

  • Park, Jong-man;Kim, Young-hyun;Jeong, Won-chan;Ryu, Jeong-min
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.5
    • /
    • pp.444-449
    • /
    • 2020
  • I proposed small ambulatory robot actuators using piezoelectric benders. In order to make the motion of the biomimetic robot legs similar to the movements of the cockroaches or similar insects, two pairs of legs in the diagonal direction in the four leg structures are required to make the same movement. And elliptical displacement is realized by taking into account horizontal and vertical displacement of multimode oscillations and driving them by electrical signals with differences step by step, for example of 90° the T-shaped robot actuator showed wide range of speed (From 2 mm/sec. up to 266 mm/sec.) and ability of transportation (up to 10 g with 50 mm/s). Locomotive performance of the robot was competitive to the preceding robots, and moreover, the modular type actuators of a segmented myriapods robot could be added and removed for different tasks or performances.

Estimation of Harmonics on Power System of AC Electric Railway (교류 전기철도 전력계통의 고조파 예측량 계산)

  • 송진호;황유모
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.2
    • /
    • pp.68-79
    • /
    • 2003
  • We estimated harmonics on power system of AC railway based on quantitatively measured harmonics and investigated the need of facilities for harmonics reduction. In order to analysis harmonics which inflow into power system due to increase in collector voltages and harmonic currents generated from the train when the railway is in operation, the railway system Is sectioned into power supply, railway line, AT, sectioning Post and subsectioning post. For analysis of extension of currents resulting from the railway loads, PWM converter, VVVF inverter and the feeder system are modeled based on the dynamic node technique(DNT). In order to test the usefulness of the DNT for analysis of harmonic effects, the measured harmonic currents and harmonic magnification ratios at the S/K substation are compared with simulation results using DNT modelling, which include the results for two cases with and without filters for suppression of harmonic currents. When 8 cars(4M4T) are in operation, the total sum of harmonic currents resulting from the train at M and T phases, which inflow into the substation along with the railway line, is calculated. Using the harmonics analysis program for railway feeder system with these data, the total harmonic distortion factor(710) at the outgoing point of KEPCO substation is computed. The calculation shows that when the maximum THD at the receiving point of H/K substation was 0.0443% which is much lower than 1.5% which is the allowable value of KEPCO at 154kV as well as IEEE-519 above 132kV This result indicates that any measure for harmonics reduction in Incheon International Airport Railway is not needed.

자기펄스압축성형법 및 방전 플라즈마 소결법의 연속공정을 이용한 $95%Bi_2Te_3-5%Bi_2Se_3$ 소결체제조 및 열전특성평가

  • Lee, Cheol-Hui;Kim, Hyo-Seop;Kim, Taek-Su;Gu, Ja-Myeong;Hong, Sun-Jik
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.48.2-48.2
    • /
    • 2011
  • 열전재료는 열과 전기에너지의 상호 변환이 가능한 재료로 이를 이용한 응용제품의 개발이 크게 주목을 받고 있으며, 특히 $Bi_2Te_3$계 합금의 경우 상온에서 가장 우수한 성능지수를 가지는 재료로 많은 연구가 진행되고 있다. 그러나 기존의 $Bi_2Te_3$계 합금은 일방향응고법으로 제조되어 많은 시간과 비용을 필요로 하고, 특히 C축의 Van der Waals 결합으로 인해 기계적 강도가 약하다는 단점이 있었다. 최근 분말야금법을 이용하여 기계적강도를 높이고, 격자산란에 의한 열전도도의 감소로 성능지수를 높일수 있는 방법들이 제시되고 있다. 본 연구에서는 급속응고공정인 가스분무법을 이용하여 n-type의 $95%Bi_2Te_3-5%Bi_2Se_3$분말을 제조하였고, 이 재료의 경우 성형조건에 따라 조직이 쉽게 변하기 때문에 이를 제어하기 위해 단시간동안 고압으로 성형가능한 자기펄스압축성형법(Magnetic Pulsed Compaction)을 이용하여 성형체를 제조하였다. 제조된 성형체는 밀도를 증가시키고 결정립성장을 억제시킬수 있는 방전플라즈마소결법(Spark Plasma Sintering)을 이용하여 소결체로 제조되었으며, 각각의 공정이 열전성능에 미치는 영향을 고찰하였다. OM (Optical Microscope) 및 SEM (Scaning Electric Microscope)을 이용하여 미세구조를 관찰하였고 XRD (X-Ray Diffraction)를 이용하여 상의 변화를 분석하였으며, 상온에서 경도를 측정함으로서 공정조건에 따른 기계적강도를 비교하였다. Seebeck계수는 시편의 양단에 온도차를 주어 발생하는 기전압을 측정하여 계산하였고, 전기비저항은 4point probe방법으로 측정하였다. 전하이동도 및 전하농도는 Hall측정으로부터 구하였고 열전도도를 측정하여 종합적인 열전성능을 평가하였다.

  • PDF

Frame Reliability Weighting for Robust Speech Recognition (프레임 신뢰도 가중에 의한 강인한 음성인식)

  • 조훈영;김락용;오영환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.3
    • /
    • pp.323-329
    • /
    • 2002
  • This paper proposes a frame reliability weighting method to compensate for a time-selective noise that occurs at random positions of speech signal contaminating certain parts of the speech signal. Speech frames have different degrees of reliability and the reliability is proportional to SNR (signal-to noise ratio). While it is feasible to estimate frame Sl? by using the noise information from non-speech interval under a stationary noisy situation, it is difficult to obtain noise spectrum for a time-selective noise. Therefore, we used statistical models of clean speech for the estimation of the frame reliability. The proposed MFR (model-based frame reliability) approximates frame SNR values using filterbank energy vectors that are obtained by the inverse transformation of input MFCC (mal-frequency cepstral coefficient) vectors and mean vectors of a reference model. Experiments on various burnt noises revealed that the proposed method could represent the frame reliability effectively. We could improve the recognition performance by using MFR values as weighting factors at the likelihood calculation step.

인터뷰 - 세계원자력협회(WNA) Agneta Rising 사무총장

  • Kim, So-Yeon
    • Nuclear industry
    • /
    • v.35 no.9
    • /
    • pp.46-52
    • /
    • 2015
  • 1975년 우라늄협회로 출발한 세계원자력협회(WNA)는 원자력을 평화적으로 이용하는 것을 적극 지원하고, 원자력 발전과 핵연료주기 전반에 걸친 원자력 산업 발전을 위하고자 설립한 세계적 민간 기구로, 우라늄 채광부터 변환, 농축, 핵연료 제조, 원자력발전 운영, 기자재(설비) 제작 및 사용후핵연료 처분에 이르기까지 원자력발전의 전 주기 산업을 촉진하고 관련 정보를 지원하고 있다. 2001년 지금의 명칭으로 변경한 WNA는 전 세계 원자력산업체와 원자력 관련 기관, 대학 등 175개 회원사를 두고 상호 협력과 전문 인력 교육 기반 강화, 국제화에 적극 나서고 있으며, 원자력산업 정보 제공과 교환을 위해 관련 보고서와 자료도 수시로 발행하고 있다. 2013년부터 WNA를 이끌고 있는 아그네타 라이징 사무총장은 지난 11월 영국 런던 소재 WNA를 방문한 <원자력신문>과의 인터뷰를 통해, 원전과 주변지역 주민의 갑상선암 발병에 대한 인과 관계에 대하여 "갑상선암 발병이 원전과 연관성 있다는 주장은 과학적 근거가 없다"고 단호히 말하고, "한국과 유사한 사례가 해외 원자력계(과학계)와 의학계에 보고된 적이 있냐"는 질문에 "해외에서 정상 운영되고 있는 원전 시설은 국제방사선방호위원회(ICRP)의 엄격한 기준(ICRP-60)이 적용하고 있으며, 방사선 방호와 관련된 연구보고서(논문)를 꾸준히 내고 있지만 원전 주변 주민에 대한 여러 역학 조사에서도 갑상선암이 증가했다는 사례는 보고된 바 없다"고 말했다. 또한 "실제로 일본 원폭 생존자 연구와 체르노빌 원전 주변 주민 연구에 의하면 20세 이상의 성인에서 방사선 노출에 의해 갑상선암이 증가한다는 증거는 없었다."면서 "체르노빌 사고와 후쿠시마 원전 사고 이후 방사선 누출로 인해 방사선이 갑상선암의 발생률을 증가시키는 것으로 알려졌지만 실제로 원전에서 발생하는 방사능은 갑상선암을 유발시킬 수 있는 양에 비해 아주 적다. 그럼에도 원전 시설에서 나오는 방사능 수치에 대해 제대로 밝히는 기관이 없기 때문에 원전 주변에 살아도 영향을 받는 것으로 오해할 수 있다."고 덧붙였다. 아그네타 라이징 사무총장은 스웨덴 출신의 방사선 방호 전문가로, 스웨덴 국영기업 Vattenfall AB 그룹에서 원자력 에너지 환경 분야 최고 전문가로 활동했으며, 스웨덴원자력학회, 유럽원자력학회, 세계여성원자력전문인회(WiN-Global) 회장 등을 역임했다. 인터뷰 전문을 게재한다.

  • PDF

Analysis of Harmonic Effects on Substation Power System and its Countermeasure (지하철 전력계통의 고조파 영향 분석 및 그 대책에 관한 연구)

  • Song, Jin-Ho;Hwang, Yu-Mo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.4
    • /
    • pp.210-220
    • /
    • 2002
  • We analysised the effect of harmonics on electric machines of substation power system barred on quantitatively measured harmonics and proposed the methods for prevention of harmonics through checking on transformer, rectifier and cable's capacities against harmonics with reference to KEPCO's electricity service standard. In order to analysis harmoninics of silicon rectifier that is power source in DC substation, computer simulations for a substation with TR of high voltage distribution switchboard are performed. Simulation results show that the total harmonic distortion factor becomes smaller for TR primary and receiving points in order rather than silicon rectifier which is harmonic generation source so that the harmonics generated frets each rectifier are outflowed to power supply and high voltage distribution switchboard The result of higher distortion factors of voltage and current for rectifier with 100% load than those with 50 % and 30% indicates that the waveform of voltage and current for the real substation power system at the office-going and the closing hours with heavy loads might be more distorted. As proposed methods for harmonic reduction, the conventional 6 pulse-type for substation is required to be replaced by 12 pulse-type for reduction of 5th and 7th harmonics. The active filter rather than the passive filter is more effective due to severe variance of rectifier loads, but the high cost is price to be paid. In view of installation area and costs, the use of 12 pulse-type transformer is desirable and then the parallel transformer and the rectifier within the substation must be replaced at the same time. Other substations with parallel feeder can use 6 pulse-type transformer.