A Study on Grounding Resistance Measurement of Power Supplying Substation using Grounding Current Division Factor and FOP Profile Method (접지전류 분류계수 및 전위강하곡선법을 이용한 운전 중인 변전소의 접지저항 측정 방법에 관한 연구)

  • An, Yong-Ho;Choi, Jong-Ki;Kim, Yong-Hak;Han, Jeong-Yeol;Lee, You-Jin;Han, Byoung-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.100-107
    • /
    • 2011
  • Since transmission and distribution neutral wires are connected with a substation grounding grid, it is very difficult to measure grounding resistance of isolated substation grounding grid after the substation is energized. It is impractical to isolate the grounding grid from other parallel connections such as distribution line neutrals and overhead ground wires for grounding resistance measurement only. In this paper, we proposed and demonstrated a novel measurement method of grounding resistance of isolated substation grounding grid. For this method, grounding current division factor and conventional FOP(Fall-Of-Potential) profiles were measured at power supplying 154[kV] substation. The obtained FOP profile was processed with the measured grounding current division factor to produce the grounding resistance of isolated grounding grid. Simulated FOP profile agreed well with the measured one showing the validity of the proposed method.

Wireless Diagnostic Technique for Pole Transformer Using SMS of Mobile Telecommunication Network (이동통신망의 SMS 방식을 이용한 주상변압기 무선 진단 기법)

  • Kim Jin-Cheol;Lee Hyang-Beom
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.2 no.3
    • /
    • pp.61-71
    • /
    • 2003
  • This paper suggests a wireless diagnostic technique using SMS (Short Message Service) of mobile telecommunication network for pole transformer. The temperature and current of pole transformer are acquired and the average and standard deviation are transmitted using SMS of mobile telecommunication network when transformer is overloaded The algorithm and protocol is design to fit the wireless diagnostic technique. By using the wireless method, the weak point of accessability can overcome. It is possible to manage, control, and monitor many transformers with just one server.

  • PDF

Analysis of Transient Voltage by Lightning Stroke at 345kV Step-up Transformer (345kV 승압용 변전소의 뇌격에 의한 이상전압 해석)

  • Cho, Man-Young;Shin, Ho-Jeon;Huh, Jae-Sun;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.10
    • /
    • pp.95-101
    • /
    • 2012
  • Typically, large scale power generation facilities are linked to 345kV transmission line through a step-up transformer. If the value of transient voltage by generating lightning stroke is large more than electric equipment's BIL, devices insulation is destroyed. LA(Lighting Arrester) is used as a main means of prevention. However, the installation of LA takes the constraints of installation place and expensive installation costs. Therefore, we need to carefully study whether installation of installation can be omitted and the most efficient place of installation. In this paper, we simulated the transient voltage detected by lightning stroke at each equipments in the 345kV transmission power grid by using EMTP-RV program.

The Prediction of Transformer Noise by Operating Situation at the Indoor Substation (옥내변전소 운전상황에 따른 변압기 소음예측)

  • Koo, Kyo-Sun;Kweon, Dong-Jin;Kwak, Ju-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.104-110
    • /
    • 2008
  • Desire about agreeable habitat by enhancement of standard of living has been increased, and common complaints by transformer noise have been happening constantly. It has been installed resonator and sound-proof shutter in order to solve substation's noise problems. But those methods are not effective. Therefore, It is necessary to study transformer noise level that can satisfy noise regulation standard. In this paper described that predicted transformer noise level of substation boundary by operating situation at the indoor substation. Also, Presented most suitable noise level of transformer that satisfy noise regulation standard at the indoor substations through predicted results.

Earth Resistance Measurement Method by Clamp-one Type Current Comparison (클램프온식 전류비교 접지저항 측정방법)

  • Jeong, M.S.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.353-355
    • /
    • 2007
  • 피접지체의 접지는 전력설비의 절연파괴,낙뢰 등으로 전압이 침입할 경우 접지전극의 접지저항이 높으면 접지전극으로 유입되는 전류와 접지저항의 곱에 해당하는 접지전극의 전위가 상승하게 되므로 설비의 파손 인축의 피해 등이 발생 할 수 있다. 따라서 접지저항은 낮은 값으로 유지하는것이 필요하고 정기적으로 측정하여 관리하도록 규정하고 있다. 대표적인 접지저항측정방법으로는 3전극법(Fall of potential method)과 Hook-on 측정법이 있다. 그러나 3전극법은 측정하고자 하는 접지전극으로부터 일정한 거리에 전류를 흘려주고 이때 대지 전위를 측정 할 수 있는 2개의 보조전극 설치가 필수적이나 접지극과 접지선의 단자와는 설치 위치가 다르므로 접지전극의 설치점을 확인하기 곤란하고 건물내부, 지하철, 터널 등에는 보조전극의 설치가 거의 불가능하므로 처음 설치한 접지극의 접지저항측정관리에 어려움이 크다. 또한 Hook-on 측정법은 다중 접지 계통에 사용하는 방법으로 접지극이 수십 또는 수백개를 병렬로 연결한 경우 측정하고저 하는 접지그의 접지저항값에 비해 나머지 접지전극 전체의 합성저항이 무시할 수 있을 만큼 적은 경우에만 측정할 수 있으므로 건물이나 변전실 등 수개의 접지극이 설치된 경우는 사용할 수 없다. 본 연구는 보조전극을 설치하지 않고 측정하고자하는 접지전극 상호간의 전류분배 비율을 저항의 역수 비율로 하여 각각의 접지 전극의 접지저항값을 운전 중인 상태에서 간단하고 정확하게 측정할 수 있는 새로운 접지저항 측정 방법에 관한 연구이다.

  • PDF

A Study on the Simulation Model of PV Generation System for its Application to Real Power System (계통 연계형 태양광 발전 시스템의 실계통 적용을 위한 시뮬레이션 모델에 관한 연구)

  • Lee, Kye-Byung;Son, Kwang-Myung;Jeon, In-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.6
    • /
    • pp.70-78
    • /
    • 2008
  • This paper deals with the simulation modeling of PV generation system for its application to utility distribution network PSCAD/EMIDC simulation model is developed for use in studying the effect of the PV generation to the distribution system. Simulation results show that the addition of the PV system improves the voltage profile of the area by decreasing the power flow from the utility substation. Case studies also show that power quality at the load side is also improved via voltage compensation at the load bus.

Harmonic Frequency Analysis of Interlocking System for Rolling Stock Operation in Electrical Railroads (전기철도 구간에서의 철도차량 운행에 따른 연동장치 고조파 분석)

  • Baek, Jong-Hyen;Kim, Yong-Kyu;Oh, Seh-Chan;Lee, Kang-Mi;Jo, Hyun-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3610-3616
    • /
    • 2011
  • Electrical Railroads provide electric power, which can operate vehicles, via feeder wires. And the supplied current returns to the transformer substation through lines and ground net. The used load current depending on the operation of rail vehicles in the electric railway sections returns to the substation through a track which is a return circuit. The load current contains harmonics because of the power conversion equipment used in rolling stocks and such harmonic currents should not affect train control system. In this paper we present the test result in order to verify that the harmonics produced by the operation of rail vehicles in the newly built electric railway sections can affect interlocking systems. The test in question was performed in a linking section that trackside equipment under railway operating conditions and interlocking are linked in order to identify whether or not the interlocking fitted in a signal machine room can be affected by harmonics according to railway operation.

Study of Deterioration Improvement of Power Fuse (전력퓨즈의 열화현상 개선에 관한 연구)

  • Song, Jae-Ki;Kim, Hwan-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3827-3831
    • /
    • 2014
  • This paper aims to solve the problem deterioration of power fuses. The deterioration of a power fuse is a cause of failure misoperation by a normal current flowing reduplicatively to fuse the element. An extension survey of a load feature rerating power fuse examined the power fuse deterioration removal, the cause of the deterioration of the power fuse, the front-after, and the thermal variation of the inside transformer room electric power equipment. The transformer showed an average improvement of $6[^{\circ}C]$. The temperature of the electrical line showed $7{\sim}8[^{\circ}C]$ improvement. The static condenser and direct reactor was $2{\sim}3[^{\circ}C]$ high-state maintenance the temperature and equipment syntonization relationship. In the subject of study $0.5{\sim}1.0[^{\circ}C]$ stabilizing three phase power fuse temperature differential was. Suggestion in the transformer room environment power equipment between the cause temperature happen elimination to deterioration of power fuse and temperature rise control.

Analysis of Probability Distribution of Tsunami Heights for Development of Tsunami Prediction Model (지진해일고 예측모델 개발을 위한 지진해일고 확률분포 분석)

  • Kim, Byung-Ho;Yu, Jae-Ung;Cho, Yong-Sik;Kwon, Hyun-Han
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.268-268
    • /
    • 2022
  • 지진해일은 발생빈도는 높지 않지만, 한 번 발생하게 되면 막대한 피해를 일으킬 수 있다. 우리나라에서는 1,900년대 4건의 지진해일이 기록되었으며, 이로 인해 동해안 및 남해안 등에 인명피해 및 재산피해가 발생하였다. 또한 2011년 동일본 지진해일로 인해 후쿠시마 원자력 발전소 변전설비가 침수됨에 따라 냉각수 공급이 중단되고 방화벽이 파괴되어 방사능이 누출되어 큰 피해로 연결되었다. 이러한 피해를 저감하기 위해 지진해일 수치해석과 확률론적 분석방법 등 다양한 방법을 활용한 연구가 국내외 적으로 활발히 수행되고 있다. 본 연구는 확률분포기반 지진해일고 예측모델 개발을 위해 수치해석을 수행하여 지진해일고(tsunami heights)를 산출하고 결과값에 대한 적절한 확률분포 분석을 실시하는 것이다. 지진해일고는 원자력발전소에서 취수구를 통한 냉각수 공급가능 여부를 판단하기 위해 최대 지진해일고(maximum tsunami height)와 최저 지진해일고(minimum tsunami height)로 구분하였다. 지진해일 수치해석은 지진원(단층매개변수) 조사, 조사된 지진원 중 지진해일 수치해석 case 선정을 위한 파향선추적기법(wave ray tracing) 수행, 선정된 지진원에 대해 로직트리(logic tree) 기법 적용, 로직트리를 적용한 지진원 case에 대한 수치해석 순서로 수행하였다. 수치해석을 통해 산출된 최대 및 최저 지진해일고 자료를 기반으로 확률분포형을 선정하기 위하여 확률분포별 적합성 평가를 실시하였다. 선정된 분포를 기준으로 처오름 및 처내림높이와 관련된 다양한 변수간의 의존관계를 파악하였다. 향후, 파악된 의존관계를 기반으로 예측모델을 개발하여 수치해석 결과와 연계함으로써 국내에 적용할 수 있는 확률론적 지진해일재해도를 제시할 수 있을 것으로 판단된다.

  • PDF

Development of Dissolved Gas Analysis/Diagnosis System with Transformer Fault Test Chamber (I) (변압기 내부 결함 모의시험장치를 통한 유중가스 분석/진단 시스템 개발(I))

  • Kim, Sung-Jik;Seo, Hwang-Dong;Kim, Young-Min;Jung, Jae-Ryong;Yang, Hang-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1554-1555
    • /
    • 2011
  • 안정적인 전력공급을 위해 전력설비 진단이 중요시 되고 있고 이를 위해 변전기기인 변압기의 초기고장 검출을 통한 예방진단 기술을 필요로 하고 있다. 변압기 예방진단 기술 중에서도 유중가스진단은 가장 오래되고 신뢰성이 입증된 기술이다. 기존의 유중가스진단법들은 가스비분석법을 이용하고 있는데 대상 가스들이 절연유에의 열화에 의해 발생하는 가스들이고 주위 운전환경에 대한 고려가 부족하여 진단이 불가능하거나 진단오류가 발생한다. 본 연구에서는 절연유뿐만 아니라 고체절연물에 대한 열화를 고려하기 위하여 변압기 내부 결함 모의 시험 쳄버를 제작하고 시험 결과를 바탕으로 진단 알고리즘을 개발하고자 한다.

  • PDF