• Title/Summary/Keyword: 변위응답

Search Result 598, Processing Time 0.025 seconds

Evaluation of Inelastic Displacement Response of Bridge Structures Using Lateral Load Distributions (횡하중 분배방법을 이용한 교량구조물의 비탄성 변위응답 평가)

  • Song, Jong-Keol;Nam, Wang-Hyun;Chung, Yeong-Hwa
    • Journal of Industrial Technology
    • /
    • v.25 no.A
    • /
    • pp.15-22
    • /
    • 2005
  • In order to evaluate seismic performance of multi-degree-of-freedom bridge structure, moderate lateral load distribution methods using the pushover analysis were developed by many researchers. One of important variables to improve an accuracy of pushover analysis is lateral load distribution. In this study, pushover analyses were performed using the five types of lateral load distribution and seismic performances were evaluated by capacity spectrum method (CSM). To verify an accuracy of suggested lateral load distribution, the maximum displacement estimates by the CSM were compared to those by inelastic time history analysis.

  • PDF

플로팅 함체와 상호 거동에 따른 상부 골조의 모멘트 증대효과

  • Lee, Yeong-Uk;Park, Jeong-A;Choe, Ji-Hun;Chae, Ji-Yong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2011.06a
    • /
    • pp.198-199
    • /
    • 2011
  • 플로팅 함체는 육상과 달리 지진하중의 영향을 받지 않으며 파랑하중의 영향을 크게 받는다. 파랑하중에 대한 안전성을 확보하기 위하여 범용구조해석 프로그램을 이용하여 해석하였다. 상부구조물의 영향을 확인하기 위하여 함체의 밀도를 변화시켜 상부하중에 대한 함체의 변위 응답을 확인을 한 결과, 밀도에 따른 함체 거동의 변화는 미미하였다. 해석을 통해 얻은 각 주기별 변위를 하중에 적용한 상부구조물의 모멘트 증가비는 파랑하중의 주기가 단주기에서 장주기로 갈수록 감소하는 양상을 보였으며, 축력은 파랑주기의 영향을 적게 받는 것으로 나타났다.

  • PDF

Effect of Dampers on Preventing Progressive Collapse in Steel Frames (감쇠기가 철골조 건물의 연쇄붕괴 방지에 미치는 효과)

  • Lee, Seung-Jun;Choi, Hyun-Hoon;Kim, Jin-Koo;Huynh, Chanh Trung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.154-157
    • /
    • 2010
  • 본 논문에서는 비선형 동적해석법을 이용하여 감쇠기의 적용이 철골조 건물의 연쇄붕괴 방지에 미치는 영향을 평가하였다. 단자유도 구조물에서 감쇠비의 변화에 따라 폭발하중이 구조물의 응답에 미치는 영향을 분석하였고, 15층 3경간 철골조 건물에서는 일정한 감쇠비 하에서 경간을 6m, 9m, 12m로 달리 하면서 감쇠기 설치 효과를 비교하였다. 단자유도 시스템의 경우 감쇠비가 증가 할수록 폭발하중에 의한 진동이 빠르게 감소하고 변위의 감소폭도 커지는 경향을 보였다. 15층 철골조 건물에서도 역시 감쇠기를 설치할 경우 수직 처짐 및 초기 진동을 제어하는 효과가 있었다. 구조물의 경간이 증가하여 수직 변위가 증가 할수록, 감쇠기에 의해 소산된 에너지도 증가하기 때문에 수직 처짐 제어효과가 큰 것으로 나타났다.

  • PDF

Dynamic Response of Plate Structure Subject to the Characteristics of Explosion Load Profiles - Part A: Analysis for the Explosion Load Characteristics and the Effect of Explosion Loading Rate on Structural Response - (폭발하중 이력 특성에 따른 판 구조물의 동적응답 평가 - Part A: 폭발하중 특징 및 재하속도의 영향 분석 -)

  • Kang, Ki-Yeob;Choi, Kwang-Ho;Ryu, YongHee;Choi, JaeWoong;Lee, Jae-Myung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.2
    • /
    • pp.187-195
    • /
    • 2015
  • The gas explosions in offshore installations are known to be very severe according to its geometry and environmental conditions such as leak locations and wind directions, and a dynamic response of structures due to blast loads depends on the load profile. Therefore, a parametric study has to be conducted to investigate the effects of the dynamic response of structural members subjected to various types of load shapes. To do so, a series of CFD analyses was performed using a full-scale FPSO topside model including detail parts of pipes and equipments, and the time history data of the blast loads at monitor points and panels were obtained by the analyses. In this paper, we focus on a structural dynamic response subjected to blast loads changing the magnitude of positive/negative phase pressure and time duration. From the results of linear/nonlinear transient analyses using single degree of freedom(SDOF) and multi-degree-of freedom(MDOF) systems, it was observed that dynamic responses of structures were significantly influenced by the magnitude of positive and negative phase pressures and negative time duration.

Seismic Response Control of Cable-Stayed Bridge using Fuzzy Supervisory Control Technique (퍼지관리제어기법을 이용한 사장교의 지진응답제어)

  • Park, Kwan-Soon;Koh, Hyun-Moo;Ok, Seung-Yong;Seo, Chung-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.4
    • /
    • pp.51-62
    • /
    • 2004
  • Fuzzy supervisory control technique for the seismic response control of cable-stayed bridges subject to earthquakes is studied. The proposed technique is a hybrid control method, which adopts a hierarchical structure consisting of several sub-controllers and a fuzzy supervisor. Sub-controllers are independently designed to reduced the responses to be controlled of a cable-stayed bridge, and a fuzzy supervisor achieves improved seismic control performance by tuning the pre-designed sub-controllers. It is realized by converting static gains of the sub-controllers into time-varying dynamic gains through the fuzzy inference mechanism. To evaluate the feasibility of the proposed technique, the benchmark control problem of cable-stayed bridge proposed by Dyke et al. is adopted. The control variables for the seismic response control of the cable-stayed bridge are determined to be t도 shear forces and bending moments at the base of the towers, the longitudinal displacements at the top of the towers, the relative displacements between the deck and the tower, and the tensions in the stay cables. Comparative results between the fuzzy supervisory controller and LQG controller demonstrate the effectiveness of the proposed control technique.

Estimation of Applicability of Empirical Design Procedure for Predicting Seismic Response of Buried Gas Pipelines through 3D Time-history Analysis (3차원 시간이력해석을 통한 매설가스배관 종방향 지진응답 예측을 위한 경험적 설계법의 적용성 평가)

  • Kwak, Hyungjoo;Park, Duhee;Lee, Jangguen;Kang, Jaemo
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.9
    • /
    • pp.53-68
    • /
    • 2015
  • Longitudinal strain is an important component of seismic design for buried pipelines. A design procedure which determines the wavelength from site natural period and shear wave velocity of the soil layer and closed-form solutions of pipelines under a harmonic motion is typically used in design. However, the applicability of the procedure has not yet been thoroughly investigated. In this paper, displacement-time histories extracted from 1D site response analyses are used in 3D shell-spring model to accurately predict the response of pipelines. The results are closely compared to those from the design procedure. The area of interest is East Siberia. Performing a site response analysis to determine site specific displacement time history is highlighted. The site natural period may be used to predict the predominant period of the acceleration time history, but cannot be used to estimate the predominant period of the displacement time history. If an accurate estimate of the predominant period of the displacement time history is provided, it is demonstrated that the design equation can be successfully used to predict the response of pipelines.

The Properties of a Nonlinear Direct Spectrum Method for Estimating the Seismic Performance (내진성능평가를 위한 비선형 직접스펙트럼법의 특성)

  • 강병두;김재웅
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.4
    • /
    • pp.65-73
    • /
    • 2002
  • It has been recognized that the damage control must become a more explicit design consideration. In an effort to develop design methods based on performance it is clear that the evaluation of the nonlinear response is required. The methods available to the design engineer today are nonlinear time history analyses, monotonic static nonlinear analyses, or equivalent static analyses with simulated nonlinear influences. Some building codes propose the capacity spectrum method based on the nonlinear static analysis(pushover analysis) to determine the earthquake-induced demand given by the structure pushover curve. These procedures are conceptually simple but iterative and time consuming with some errors. This paper presents a nonlinear direct spectrum method(NDSM) to evaluate seismic performance of structures, without iterative computations, given by the structural initial elastic period and yield strength from the pushover analysis, especially for MDF(multi degree of freedom) systems. The purpose of this paper is to investigate the accuracy and confidence of this method from a point of view of various earthquakes and unloading stiffness degradation parameters. The conclusions of this study are as follows; 1) NDSM is considered as practical method because the peak deformations of nonlinear system of MDF by NDSM are almost equal to the results of nonlinear time history analysis(NTHA) for various ground motions. 2) When the results of NDSM are compared with those of NTHA. mean of errors is the smallest in case of post-yielding stiffness factor 0.1, static force by MAD(modal adaptive distribution) and unloading stiffness degradation factor 0.2~0.3.

Comparative Study on Seismic Performance of Viscously Damped Self-Centering SDOF Systems with Elasto-Plastic SDOF Systems (점성 감쇠기를 가진 셀프 센터링 단자유도 시스템과 탄소성거동의 단자유도 시스템의 내진성능 비교에 관한 연구)

  • Kim, Hyung-Joon
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.6
    • /
    • pp.553-561
    • /
    • 2010
  • The purpose of this paper is to analytically find the approximate supplement damping ratio of the viscous damper installed in self-centering (SC) single-degree-of-freedom (SDOF) systems with maximum displacements that are similar to those of elasto-plastic (EP) SDOF systems. The behavior of an SC SDOF system under harmonic cyclic loading was first described. Then an analytical model that can capture the behavior of the viscously damped SC SDOF system was introduced. Analysis parameters that characterize the hysteresis of the EP and SC SDOF systems were chosen, and nonlinear time-history analyses were performed using 20 historical accelerograms. Most of the SC SDOF systems with viscous dampers with approximately 10-15% damping ratios presented mean maximum displacement values that were similar to those of the EP SDOF systems. To investigate in detail the seismic performance of both systems, three EP SDOF systems and six corresponding SC SDOF systems were selected. The analyses showed that all the SC SDOF systems eliminated the residual displacements after the end of their shaking, and that the SC SDOF systems with 15% damping ratios performed better than the EP SDOF systems in terms of maximum displacement and acceleration response.

A proposal of simple evaluation on the seismic performance of tunnel lining (터널 라이닝의 내진성능 간편 평가법 제안)

  • Ahn, Jae-Kwang;Byun, Yoseph;Lee, Gyuphil;Lee, Seongwon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.361-374
    • /
    • 2018
  • The country has built and is operating IT-based integrated management system for efficient management of national highway tunnels used publicly these days. Since this system doesn't include the management function on earthquakes, it is impossible to promptly respond to earthquakes and to select the sections requiring seismic reinforcement. Tunnels designed and constructed after 1999 have been subjected to seismic design for an earthquake with a return period 1000 years. Therefore, it is necessary to evaluate the stability of structures in case of earthquakes more than this. Since it takes a lot of time to perform the stability evaluation on various earthquake magnitudes, a method that can easily evaluate earthquakes is needed. In this paper, the empirical simplification method that can easily evaluate the earthquake was proposed. For this, the study calculated ground displacement by conducting one-dimensional ground response analysis, and examined the safety of tunnels in the event of occurrence of an earthquake using two means of response displacement method (analytics and numerical analysis).

Wind Tunnel Test Study on the Characteristics of Wind-Induced Responses of Tall Buildings with Openings (중공부(中空部)를 가진 고층건축물(高層建築物)의 풍응답(風應答) 특성(特性)에 관한 풍동실험(風洞實驗) 연구(硏究))

  • Kim, Dong Woo;Kil, Yong Sik;Ha, Young Cheol
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.4 s.77
    • /
    • pp.499-509
    • /
    • 2005
  • The excessive wind-induced motion of tall buildings most frequently result from vortex-shedding-induced across-wind oscillations. This form of excitation is most pronounced for relatively flexible, lightweight, and lightly damped high-rise buildings with constant cross-sections. This paper discusses the aerodynamic means ofmitigating the across-wind vortex shedding induced in such situations. Openings are added in both the drag and lift directions in the buildings to provide pressure equalization. Theytend to reduce the effectiveness of across-wind forces by reducing their magnitudes and disrupting their spatial correlation. The effects of buildings with several geometries of openings on aerodynamic excitations and displacement responses have been studied for high-rise buildings with square cross-sections and an aspect ratio of 8:1 in a wind tunnel. High-frequency force balance testshave been carried out at the Kumoh National University of Technology using rigid models with 24 kinds of opening shapes. The measured model's aerodynamic excitations and displacement were compared withthose of a square cylinder with no openings to estimate the effectiveness of openings for wind-induced oscillations. From these results, theopening shape, size, and location of buildings to reduce wind-induced vortex shedding and responses were pointed out.