• Title/Summary/Keyword: 변위손상

Search Result 322, Processing Time 0.037 seconds

Crack Mitigation of Reinforced Concrete and Expansive SHCC Composite Slabs (콘크리트와 팽창형 SHCC 합성 슬래브의 균열제어 성능)

  • Yun, Hyun-Do;Lim, Sung-Chan;T., Iizuka;Y., Sakaguchi;K., Rokugo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.23-24
    • /
    • 2009
  • This paper explores the structural application of an expansive SHCC to improve the crack-damage properties of RC flexural members. The results of test on four simply supported slabs are described. The effect of the type of SHCC (Non-and expansive SHCC) and thickness of SHCC layer (10 and 20mm) on the ultimate flexural load, first crack load, crack width and spacing, and the load-deflection relationship of one-way slabs was investigated.

  • PDF

Building Response to Excavation-Induced Ground Movements and Damage Estimation (굴착유발 지반변위에 의한 인접구조물의 거동 및 손상도 예측)

  • Son, Moo-Rak;Cording, E.J.
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.249-256
    • /
    • 2006
  • New infrastructures and buildings are being constructed increasingly in congested urban areas, and excavation-induced ground movements often cause distortion and damage to adjacent buildings. Protection of adjacent structures occupies a major part of the cost, schedule and third-party impacts of urban development. To limit damage or mitigate their effects on nearby structures, it is highly important to understand the whole mechanism from excavation to building damage, and to estimate building damage reliably before excavation and provide appropriate measures. This paper investigates the effects of excavation-induced ground movements on nearby structures, considering soil-structure interactions for ground and structures, and a building damage criterion, which is based on the state of strain, is proposed. The criterion is compared with other existing damage estimation criteria and a procedure is finally provided for estimating building damage due to excavation-induced ground movements.

  • PDF

The Verification Test for the Primary Piping System of Nuclear Power Plant (원자력 발전소 1차계통 배관 건전성 평가)

  • Lee, Hyun;Kim, Yearn-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.318-321
    • /
    • 1995
  • 원자력 발전소의 안전성 보장 및 신뢰성 향상을 위하여 시운전 단계에서 원자력 발전소내 안전등급에 해당하는 배관계통의 상태 확인을 위하여 각종시험을 하도록 되어있다. 특히 새로운 설계기념, 크기 또는 용량을 갖는 원자로 모델에 대해서는 필수적으로 건전성 평가를 하게 되었다. 이를 위해 발전소 건설기간에 시행하는 고온 기능시험 중에 원자로 주변 주요 시스템인 원자로 냉각재 루프 계통에 대한 건전성 확인을 위해 압전형 고온 가속도 센서를 이용하여 정상운전상태의 진동을 측정하여 시스템 진동거동을 규명하였다. 배관시스템의 일상운전상태는 유체의 흐름과 기기운전이 일정한 정상상태와 펌프의 기동 또는 정지 및 밸브의 급격한 개폐등으로 발생하는 과도상태로 나눌 수 있다. 따라서 두 가지 상태의 진동을 측정해야 한다. 배관계통은 정상운전 상태로 설계수명을 유지할 수 있어야 하므로 정상진도잉 최소화 되어야 한다. 진동 평가기준은 배관재질의 응력(S/N 커브) 곡선을 참조하여 설계수명내에 손상이 일어나지 않도록 재료의 허용응력을 산정하고 이를 진동변위로 환산하여 정한 것이며 이 값에 측정 데이타를 비교하여 1차계통 배관의 건전성을 확인하였다.

  • PDF

Development of Fast Neutron Detector and its Characteristics (속중성자 탐지용 반도체 소자의 개발과 특성분석)

  • Lee, Nam-Ho;Cho, Jae-Wan;Jung, Hyun-Kyu;Kim, Sung-Ho;Kim, Yang-Mo;Han, Min-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1562-1565
    • /
    • 2002
  • 속중성자 피폭 시 실리콘 다이오드 내부에서 발생되는 변위 손상을 이용한 속중성자 탐지용 PIN 다이오드를 개발하고 중성자장에서 특성변화 및 감도 실험을 통하여 성능을 검증하였다. 시뮬레이션과 다양한 구조로 제작된 소자에 대한 방사선 실험을 거쳐 집합체 형태와 개별 PIN 다이오드를 제작한 다음 중성자 반응 특성과 감도 분석을 위한 중성자 방사선 실험을 수행하였다. 여러 개의 PIN 다이오드 샘플에 대한 중성자 특성변화를 실시간으로 측정하기 위해 디지털 정전류 구동 방식의 온라인 전자적 선량계 모듈을 제작하여 사용한 실험의 결과. 본 연구에서 개발한 PIN 다이오드 소자는 중성자 방사선에 대하여 우수한 감도 특성을 갖는다는 것과 입사 중성자에 대한 방향 의존성이 거의 없다는 사실을 알 수 있었다. 그리고 이어 수행된 300여 시간의 열화실험을 통하여 본 연구에서 제작된 PIN 다이오드 소자는 중성자 탐지소자로서의 사용 가능성이 충분함을 확인할 수 있었다.

  • PDF

A Experimental Study for the Disaster Monitoring by Integration of USN and Spatial Information (변위측정센서를 이용한 대형 시설물 안전관리 방안 연구)

  • Yeon, Sang-ho;Yeon, Chun-Hum;Kim, Jong-Soo
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2016.05a
    • /
    • pp.195-196
    • /
    • 2016
  • 본 연구는 건설된 구조물의 주요 구조부재에 각종 계측 Sensor를 설치하여 이로부터 다양한 정보를 제공받아 Monitoring하는 계측 System은 대형구조물의 구조적 응답을 계측하여 분석하고, 구조물의 위험요소를 사전에 발견하고 분석하여 적절한 대책을 수립함으로써 대형 시설물의 수명연장 및 유지관리 비용의 효율성을 높이고, 구조물의 사용성 및 안전성을 확보하고, 그 설계수명을 유지할 수 있는 것이다. 계측전 초기치와의 비교 및 시간 경과에 따른 추이 분석을 통해 이상상태를 발견하는 신호 기반 감시 수행하고 있고, 상태판정 및 손상도 추정이 가능하므로 향후 계속해서 발전시켜 나갈 수 있는 지식기반 감시시스템이 필요하므로 본 연구에서는 공간 정보기반의 정보를 재생하여 GNSS/USN기술을 접목시켜감으로 대형시설물 안전관리가 매우 용이하게 적용할 수 있도록 하였다.

  • PDF

OPTIC NERVE BLINDNESS FOLLOWING MIDFACIAL FRACTURES (중앙 안면부 골절후 발생한 시신경 실명)

  • Lee, Jae Hwy
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.3
    • /
    • pp.324-331
    • /
    • 1991
  • Ocular injuries often accompany midfacial trauma Blindness related to indirect optic nerve injury in midfacial fractures is an uncommon and usually permanent complication. Opic nerve blindness is secondary to an indirect optic nerve injury due to the skeletal distortion that occurs in a facial fracture and almost all are caused by frontal, nasoethmoido-frontal or Le Fort III type fractures. When the loss of vision following midfacial fractures is complete and immediate, the prognosis is poor in spite of treatment. Computed tomography revealed compressin of the optic nerve by bony fragments. And so if injury to the optic nerve is suspected, a CT-scan must be performed and massive steroid therapy must be started as soon as possible. Surgery must be performed if there are hematoma or bony fragments injuring the nerve. The following report concerns two patients who suffered immediate and total loss of vision due to a midfacial fracture with no improvement after massive steroid therapy and surgial decompression.

  • PDF

A Numerical Study of the Shear Behavior of a Rock Joint Considering Quantitative Roughness Parameters (정량적인 거칠기 파라미터를 고려한 절리면 전단거동의 수치해석)

  • 김대복;손봉기;이정인
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.4
    • /
    • pp.279-288
    • /
    • 2001
  • 암반내에 존재하는 불연속면은 지하구조물의 안정성에 큰 영향을 미친다. 불연속면을 해석하기 위한 구성법칙에 대한 많은 연구가 진행되어 왔으나, 객관적인 거칠기 파라미터를 이용한 전단거동 모사에 관한 연구는 아직 미흡한 실정이다. 본 연구에서는 정량적인 거칠기 파라미터를 이용한 두 가지의 새로운 구성방정식을 만들어 절리 거동을 모사하였다. 첫 번째 구성법칙은 탄소성 이론에 근거하여 두께가 없는 개별절리요소 이용한 방법이고, 두 번째 구성법칙은 3차원 레이저 변위 측정 데이터를 직접 이용하여 Ohnishi가 제안한 거칠기 손상모델을 도입하였다. 제안된 두 모델을 가지고 직접 전단시험을 모사해본 결과 실제 실험에 나타나는 변형률 경화 및 연화현상 그리고 잔류전단강도와 같은 현상을 볼 수 있었다.

  • PDF

Probabilistic Neural Network for Vibration Control of Structures (구조물의 능동제어를 위한 확률신경망 이론)

  • Kim, Doo-Kie;Chang, Seong-Kyu;Kim, Dong-Hyawn;Lee, Jong-Jae
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.382-389
    • /
    • 2006
  • 구조 재료와 시공기술의 발달로 구조물은 높고 길게 설계할 수 있게 되었으나, 그에 따른 진동 문제와 사용성에 관한 문제가 발생하였고 구조물의 과다한 변위는 구조물에 심각한 손상을 발생 시켰다. 이러한 구조물의 진동 문제를 해결하기 위하여 본 논문에서는 확률신경망이론을 사용한 구조물의 능동제어방법을 제안하였다. 구조물의 제어를 위하여 LQR 제어알고리즘을 이용하여 구조물의 상태벡터와 제어력을 구한 후, 상태벡터를 입력으로 제어력을 출력으로 하는 확률신경망의 훈련패턴을 구성하였다. 제안된 방법을 사용하여 지진하중을 받는 3층 빌딩구조물을 제어하였고, 기존의 인공신경망의 제어 결과와 비교하였다.

  • PDF

A Study on Integrated Control and Safety Management Systems for LNG Membrane Storage Tank (멤브레인식 LNG 저장탱크용 통합제어안전관리시스템에 대한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.2
    • /
    • pp.40-46
    • /
    • 2010
  • In this study, the integrated control and safety management system for a super-large LNG membrane storage tank has been presented based on the investigation and analysis of measuring equipments and safety analysis system for a conventional LNG membrane storage tank. The integrated control and safety management system, which may increase a safety and efficiency of a super-large LNG membrane storage tank, added additional pressure gauges and new displacement/force sensors at the steel anchor between an inner tank and a prestressed concrete structure. The displacement and force sensors may provide clues of a membrane panel failure and a LNG leakage from the inner tank. The conventional leak sensor may not provide proper information on the membrane panel fracture even though LNG is leaked until the leak detector, which is placed at the insulation area behind an inner tank, send a warning signal. Thus, the new integrated control and safety management system is to collect and analyze the temperature, pressure, displacement, force and LNG density, which are related to the tank system safety and leakage control from the inner tank. The digital data are also measured from measurement systems such as displacement and force of a membrane panel safety, LNG level and density, cool-down process, leakage, and pressure controls.

CONSERVATIVE APPROACH ON THE SEVERELY DISPLACED ROOT FRACTURE OF PRIMARY INCISORS : CASE REPORT (심하게 변위된 유전치 치근파절의 보존적 접근)

  • Kim, Jee-Young;Lee, Kwang-Hee;Kim, Dae-Eop;Ra, Ji-Young;Lee, Dong-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.571-577
    • /
    • 2008
  • Root fracture of primary teeth is relatively uncommon because the more pliable alveolar bone allows displacement of the tooth. Root fracture of primary teeth is occupied $2{\sim}7%$ in trauma pattern of primary teeth. A horizontal root fracture is classified based on the location of the fracture in relation to the root tip : the apical third, middle third, or cervical third of the root. The prognosis worsens the further cervically the fracture has occurrer. Root fracture of primary teeth should be treated by splinting the incisor to the adjacent normal teeth with a resin-wire splint for $8{\sim}12$ weeks. However, if a portion of the root is abscessed or extremely mobile, it can be extracted, and the remaining root fragment will resorb normally. For coronal third fracture in primary teeth, the coronal third is extracted, leaving the apical portion of the root to resorb normally. These root fracture cases of primary teeth were treated by resin-wire splinting despite extremely mobile coronal fragment. Even though they seems like healing well, They need to be monitored regularly until their successors erupt.

  • PDF