• Title/Summary/Keyword: 벡터인버터

Search Result 188, Processing Time 0.022 seconds

MPPT Control of PV Water Pumping Using BLDC Motor-Inverter (BLDC 모터용 인버터를 이용한 PV 양수펌프의 MPPT 제어)

  • 김성남;백승길;조정민;이승환;오봉환;이훈구;한경희
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.498-505
    • /
    • 2001
  • This paper shows how to design a global control of water pumping system using PV array, and tracked maximum power point of PV array only the inverter using the vector control of BLDC motor, and finding the relationships among the DC magnitudes and AC ones in order to omit the DC/DC converter. Conventional MPPT controller was unstable of reason of the ripple-current of DC link in three-phase invertor. Thus, in this paper the control algorithm of BLDC motor using $i_qs$ current is composed to improve the insecurity of conventional MPPT controller To prove the excellence of the proposed method, the contents of this paper is analyzed by means of simulation and testing for the results applying the method that J. A Domfnguez had applied to asynchronous motor to BLDC motor and that of the proposed method in this paper.

  • PDF

A New Two-Phase Random Pulse Position PWM Scheme (새로운 2상 랜덤 펄스 위치 PWM기법)

  • 魏 昔 吾;鄭 榮 國;羅 碩 煥;任 永 徹
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.194-204
    • /
    • 2002
  • In this paper, a new two-phase space vector RPWM(Random PWM) is proposed. In the proposed RPWM, each of two-phase PWM pulses is located randomly in each switching interval. Based on the space vector modulation technique, the duty ratio of the pulses is calculated. Along with the randomization of the PWM pulses, we can obtain the effects of spread spectra of inverter output voltage, d.c link current and audible switching acoustic noise as in the case of randomly changed switching frequency. To verily the validity of the proposed two-phase RPWM scheme, the experiment based on the Cl67 micro-controller was executed. The performance of the proposed scheme was compared with traditional PWM schemes experimentally.

A Novel Direct Torque Control of Induction Machines based on Stator Flux (고정자 자속을 기반으로 한 유도전동기의 새로운 직접 토크 제어)

  • 박준현;정종진;최종우;김흥근;노의철;부경대학교전기제어계측공학부조교수
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.297-302
    • /
    • 2002
  • The direct torque control(DTC) of induction machines has the advantages of a simple control scheme and a very quick and robust torque response and its application is extended in the traction field. However, some drawbacks of the conventional DTC strategy using a hysteresis controller are the relatively large torque ripple in the steady state and the variation of switching frequency according to the amplitude of hysteresis bands and the motor operating conditions. In this paper, a navel direct t()roue control scheme of induction machines based on stator flux control and Space Vector Modulation Is proposed to acquire the advantage of a fixed switching period and the minimization of the torque and stator current ripple in a wide speed range. The effect of proposed method has been proven by simulations and experiments.

Reduction of Torque Ripple due to Current-Sensing Errors in Inverter-Fed AC Motor Systems (인버터의 전류측정 오차에 기인하는 교류전동기의 토크리플 저감)

  • 윤덕용;홍순찬
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.280-286
    • /
    • 1998
  • This paper proposes a novel method to reduce the torque ripple due to the non-ideality of the current sensing parts in vector-controlled inverter-fed AC motor drive systems. For PMSM(Permanent Magnet Synchronous Motor), motor output torque equations are derived in terms of their offset voltages and different voltage transducing gains. And the effects of phase current errors on motor torque are analyzed for both salient PMSM and non-salient PMSM. The proposed method can eliminate the torque ripple by nulling the offset voltages and setting the voltage transducing gains to the same value. To verify the proposed method, digital simulations are carried out for non-salient PMSM.

  • PDF

Evaluation of Energy Saving with Vector Control Inverter Driving Centrifugal Pump System (벡터 제어 인버터 구동 원심펌프시스템의 에너지 절감 평가)

  • Suh, Sang-Ho;Kim, Kyungwuk;Kim, Hyoung-Ho;Yoon, In Sik;Cho, Min-Tae
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.2
    • /
    • pp.67-72
    • /
    • 2015
  • The purpose of this study is to achieve energy saving effect of inverter driving multistage centrifugal pump. For determining the operation points in the pump system, the system curves should be obtained experimentally. To get the system curves, three pumps combined in parallel and one pump operated with different rotational speeds. But for variable speed pump system, energy saving rates can not be evaluated from operation efficiencies. That is why operation efficiencies, system curves, duty cycles, and input powers of the pump system were measured by the constructed experimental apparatus. The duty cycle segmented into different flow rates and weighting the average value for each segment by the interval time. The system was operated with two different periods. The mean duty cycles were collected from apartment and found that the system operated at 40% and at 50% or below capacity. Measured energy saving rate was 58.16%. Estimating method of energy saving rate could be more effective operation index than that of operation efficiency.

Modeling of SVPWM and Control Method for Driving Systems of High-speed Trains by using Multi-level Power Converters (고속전철 추진시스템을 위한 멀티레벨 전력변환기의 제어기법 및 SVPWM 모델링)

  • Lee, Dong-Myung;Hong, Chan-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.136-145
    • /
    • 2009
  • This paper proposes control methods and simulation models of a driving system, which consists of converters and inverters, for high speed trains employing multi-level power converters. The control method of a single phase three-level converter for high-speed trains is designed to use DC values instead of instantaneous current values which are usually used in single-phase application, so that it results in a fast and robust voltage control response. In addition, simulation models of Space Vector Pulse Width Modulation (SVPWM) for single phase three-level converters as well as three level inverters are proposed. Experimental results demonstrate the validity of the simulation model for three-level inverters.

Modified space vector modulation for minimum inductor current ripple in QZSI fed induction motor drive system (QZSI를 이용한 유도 전동기 구동 시스템에서 인덕터 전류 리플을 최소화하기 위한 변형공간벡터변조방법)

  • Han, Sang-Hyup;Kim, Heung-Geun;Cha, Honnyong;Chun, Tae-Won;Nho, Eui-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.515-516
    • /
    • 2016
  • QZSI(Quasi Z-Source Inverter)를 이용한 유도전동기 제어 시스템은 암단락 상태를 제어에 이용할 수 있어서 추가 컨버터 없이도 단일 구조로 가변 배터리 전압을 일정하게 승압할 수 있다. 암단락을 이용한 승압은 직류단 전압제어가 보장되어야 하며 전압 제어기 성능이 인버터 출력 전류 제어에 상당한 영향을 미친다. 본 논문은 QZSI에서 직류 전압을 승압시키기 위한 암단락 시간을 효율적으로 제어하여 인덕터 전류 리플을 감소시키는 변형 공간벡터방식을 이용하여 유도 전동기를 제어하고 시뮬레이션과 실험을 통해 이를 검증한다.

  • PDF

Sensorless Control of IPM with flux estimator (자속추정기를 사용한 IPM Sensorless 제어 방법)

  • Kim Kwang-Min;Kim Sun-Ja;Kim Jeong-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.98-100
    • /
    • 2006
  • 본 논문은 매입자석형 동기전동기 (Interior Permanent Magnet Motor, 이하 IPM)의 Sensorless 제어에 관한 것이다. IPM에서 벡터제어를 수행하기 위해서는 계자분 전류와 토크분 전류로 나누어서 제어를 해줘야 한다. 이때, 토크는 영구자석과 직교하는 방향으로 토크분 전류를 인가해줘야 하기 때문에, 영구자속에 의해 발생하는 자속의 정확한 위치를 알아야 하고, 그로 인하여 엔코더 등의 자극위치센서를 사용해야 한다. 따라서, IPM은 일반적으로 Sensored제어를 하게 된다. 그러나, 고가의 장치인 엔코더 등의 자극위치센서를 사용하지 않고 적절한 제어를 수행해주기 위하여 여러 sensorless 기법들이 개발되어 발전되었다. 본 논문에서는 자속추정기를 이용하여 자속을 추정하고, 이를 이용하여 모터의 회전속도 및 회전각을 추정함으로써 Sensorless제어가 가능하였다. 본 제어 알고리즘은 자사 벡터제어 인버터인 iV5를 통해 실험하여 확인하였다.

  • PDF

Dead Time Compensation of Vector Controlled Inverter Using Space Vector Modulation Method (공간벡터 전류제어 기법을 이용한 벡터제어형 인버터의 dead time 보상)

  • Hong, Ki-Phil;Oh, Won-Seok;Kim, Young-Tae;Kim, Hee-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.265-269
    • /
    • 1994
  • The switching dead time avoiding a bridge leg short circuit in PWM voltage source inverter produces distortions of the controlling inverter output performance such as current waveform, voltage vector, and torque. In this paper, the influence of dead time is investigated. The on-line space voltage vector modulation method is used for current controller. It is possible to compensate dead time by space voltage vector modulation which generates additional pulse compensating voltage distortion caused by dead time. In addition, narrow pulse which is generally neglected can be compensated. All the algorithms, including field-oriented control are performed by one chip microprocessor 80C196MC and DSP TMS320C31. Experimental results probe that the proposed scheme provides a good inverter output performance.

  • PDF

Induction Motor Drive System Using QZSI With Modified Space Vector Modulation (변형 공간벡터변조방식을 적용한 QZSI 유도 전동기 구동 시스템)

  • Han, Sang-Hyup;Kim, Heung-Geun;Cha, Honnyong;Chun, Tae-Won;Nho, Eui-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.181-182
    • /
    • 2015
  • QZSI(Quasi Z-Source Inverter)를 이용한 유도전동기 제어시스템은 암단락 상태를 제어에 이용할 수 있어서 추가 컨버터 없이도 단일 구조로 가변 배터리 전압을 일정하게 승압할 수있다. 암단락을 이용한 승압은 직류단 전압제어가 보장되어야 하며 전압 제어기 성능이 인버터 출력 전류 제어에 상당한 영향을 미친다. 본 논문은 QZSI에서 직류 전압을 승압시키기 위한 암단락 시간을 효율적으로 제어하기 위한 변형 공간벡터방식을 이용하여 유도 전동기를 제어하고 시뮬레이션과 실험을 통해 이를 검증한다.

  • PDF