The study of Shear Bond Strength on recasting of non-beryllium non-precious alloy for Porcelain between Metal (베릴륨이 포함되지 않은 도재용착주조관용 비 귀금속 합금의 재사용에 따른 금속과 도재간의 전단결합강도에 관한 연구)

  • Kim, So-Ri;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.35 no.1
    • /
    • pp.43-48
    • /
    • 2013
  • Purpose: This study aimed to investigate the shear bond strength for non-precious alloy castings without beryllium, which has been used repeatedly for economical reason. Methods: The Schmitz-Schulmeyer test method was used to evaluate the shear bond strength between the non-beryllium Ni-Cr alloy Vera Bond 2V(AlbaDent, Inc. USA) and the Ceramco 3(Dentstply, York, PA, USA) porcelain powder. The maximum loading and shear bond strength were measured. The average shear strength(MPa) was analyzed with the one-way ANOVA and the Tukey's test( =.05). The fracture specimens were examined using Microscope to determine the failure pattern. Results: The mean shear bond strengths(SD) in MPa were group A(100% new metal) control 28.72(3.31); group B(50% new + 50% reused) 27.28(1.13); group C(all reused) 26.61(5.47). Microscope examination showed that group A and B specimens presented mixed failure, and group C specimens showed adhesive failure. Conclusion: In conclusion, forward this non-precious alloy dose not contain beryllium for how should use a more systematic study and for future advanced research is performed giving effect to be considered desirable.

Evaluation of the Concentration Distribution and the Contamination Influences for Beryllium, Cobalt, Thallium and Vanadium in Soil Around the Contaminated Sources (오염원 인근 토양 중 베릴륨(Be), 코발트(Co), 탈륨(Tl), 바나듐(V)의 농도분포 및 오염영향 평가)

  • Lee, Hong-gil;Noh, Hoe-Jung;Yoon, Jeong Ki;Lim, Jong-hwan;Lim, Ga-Hee;Kim, HyunKoo;Kim, Ji-in
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.4
    • /
    • pp.48-59
    • /
    • 2018
  • Beryllium (Be), cobalt (Co), thallium (Tl) and vanadium (V) are candidates of 21 priority soil pollutants in Korea. The distribution of their concentration in soils from three contamination sources including industrial, roadside and mining areas was investigated. Concentrations of the metals were evaluated quantitatively using pollution indices and the fractionation of metals was conducted using modified SM&T (Standards Measurements and Testing programme) sequential extraction. Concentrations of the metals for all samples from industrial and roadside soils were within the range of natural background levels, while some of Be in soils from abandoned mines exceeded that the range. Enrichment Factor (EF) and Nemerow Integrated Pollution Index (NIPI) for Be, Co, Tl and V showed that there are effects or possibilities of anthropogenic activities. Pollution Load Index (PLI) analyses indicated all investigated sites needed further monitoring. The results of sequential extractions indicated mobile fractions (F1+F2) of Be, Tl and V were below 30% except some of Co in soil, which implies their low mobility to neighboring environment media. Variable tools like sequential extraction, comparison with background/actual concentration and pollution indices, as well as aqua regia extraction should be considered when evaluating Be, Co, Tl, V in soil.

Evaluating Activation for 50 MeV Cyclotron Irradiation Service using Monte Carlo Method and Inventory Code (50 MeV 사이클로트론 조사 서비스로 인한 방사화 평가)

  • Kim, Sangrok;Kim, Gi-sub;Heo, Jaeseung;Ahn, Yunjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.415-427
    • /
    • 2021
  • Korea Institute of Radiological and Medical Sciences has provided various beam irradiation services to researchers using a 50 MeV cyclotron beam line. In particular, since the neutron beam service uses the nuclear reaction between protons and beryllium, the possibility of activation of the irradiated sample increases by using a high current. In this study, MCNP 6.2 and FISPACT-II 4.0 were used to evaluate the possible activation during the 35 MeV 20 ㎂ neutron beam service, which is preferred by the researchers. As a result of the calculation, if the iron, copper, and tungsten samples were irradiated for more than 1 hour, long-lived radioisotopes were produced and their radioactivity exceeded the standard level for self-disposal. Under the conditions of 2 hours of daily irradiation, no activation occurred in the building materials, and the internal exposure of workers due to air activation inside the irradiation room was very insignificant. And when this air was discharged to environment, the radioactivity including this air was also satisfied the emission standard.

A Study of Be Levels in p-GaSb:Be/GaAs Epitaxial Layers (p-GaSb:Be/GaAs 에피층의 Be 준위에 관한 연구)

  • Noh, S.K.;Kim, J.O.;Lee, S.J.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.2
    • /
    • pp.135-140
    • /
    • 2011
  • By investigating photoluminescence (PL) spectra (20 K) of undoped and Be-doped p-type GaSb/GaAs epilayers, the origin has been analyzed by the change due to doping density. We have observed that the PL peak shifts to higher energy and the full-width half-maximum (FWHM) decreases with increasing the doping density below ${\sim}10^{17}cm^{-3}$, contrasted to shift to low energy and increasing FWHM above the density of ${\sim}10^{17}cm^{-3}$. From the variation of the integrated PL intensities of three peaks dissolved by Gaussian fit, it has been analyzed that, as the density increases, the $Be[Be_{Ga}]$ acceptor level (0.794 eV) reduces, whereas the intrinsic defect of $A[Ga_{Sb}]$ (0.778 eV) enhances together with a new $Be^*$ level (0.787 eV) locating between A and Be. We have discussed that it is due to coexistence of the Be acceptor level (${\Delta}E=16meV$) and the complex level (${\Delta}E=23meV$), $Be^*[Ga_{Sb}-Be_{Ga}]$combined by Be and A, in Be-doped p-GaSb, and that the level density of $Be[Be_{Ga}]$ may be reduced above ${\sim}10^{17}cm^{-3}$.

Design of X-ray Target for a CNT-based High-brightness Microfocus X-ray Tube (탄소나노튜브를 이용한 고휘도 마이크로빔 X-선원 발생부 설계)

  • Ihsan Aamir;Kim Seon Kyu;Heo Seong Hwan;Cho Sung Oh
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.1
    • /
    • pp.103-109
    • /
    • 2006
  • A target for a high-brightness microfocus x-ray tube, which is based on carbon nanotubes (CNT) as electron source, is designed. The x-ray tube has the following specifications: brightness of $1\times10^{11}phs/s.mm^2. mrad^2$, spot size $\~5{\mu}m$, and average x-ray energy of $20\~40 keV$. In order to meet the specifications, the design parameters of the target, such as configuration, material, thickness of the target as well as the required beam current, were optimized using computer code MCNPX. The design parameters were determined from the calculation of both x-ray spectrum and intensity distribution for a transmission type configuration. For the thin transmission type target to withstand vacuum pressure and localized thermal loading, the structural stability and temperature distribution were also considered. The material of the target was selected as molybdenum(Mo) and the optimized thickness was $7.2{\mu}m$ to be backed by $150{\mu}m$ beryllium (Be). In addition, the calculations revealed that the maximum temperature of the transmission target can be maintained within the limits of stable operation.

Shear bond strength analysis of non beryllium PFM metal with degassing and opaque firing techniques (도재용착용 Non beryllium 합금의 degassing과 opaque의 소성술식에 따른 결합강도 분석)

  • Im, Joong-Jae;Lee, Sang-Houck
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4357-4363
    • /
    • 2015
  • This study is to compare the differences of bonding strength based on the Degassing temperatures and various opaque materials for Ni-Cr alloy specimen which does not contain beryllium(Be). Numerous comparison tests have been performed to measure the bonding strength by experimenting 3-point flexural rigidity tests in order to find out ways of stabilization and enhancement of bonding strength between metal and porcelain. AVOVA, surface component observation experiment by SAM/EDS, and Tukey's HSAD posteriori tests results are as follows: First, The bonding strength in all groups has exceeded the minimum (25MPa) of ISO9693 bonding strength regulation for dental mental-porcelain specimen. Second, The bonding strength of Group V1 was $32.37{\pm}1.91MPa$, $38.25{\pm}1.38MPa$ in Group V2, $46.43{\pm}2.14MPa$ in Group V3 and $47.21{\pm}1.72MPa$ Group V4. The difference has been statistically meaningful. Tukey's HSAD posteriori tests results have shown that the bonding strength in Group V4 was higher than that of Group V1. Third, the bonding strength between metal and porcelain without degassing process was higher than that of with degassing process, and the bonding strength of powder opaque was higher than that of paste opaque. Fourth, Group V4 has ranked the highest on the comparison table of metal and porcelain bonding strength.

Evaluation of a metal level in non-precious metal alloys dental casting having beryllium by lactic acid Solution (베릴륨함유 치과 주조용 비귀금속 합금의 젖산용액에 의한 금속 노출수준 평가)

  • Park, Soo-Chul;Jang, Eun-Jin;Han, Sok-Yoon
    • Journal of Technologic Dentistry
    • /
    • v.33 no.2
    • /
    • pp.121-128
    • /
    • 2011
  • Purpose: The purpose of this study is to investigate the level of each metal in non-precious metal alloys dental casting, still used even banned for use and trade by the law, for oral health. Methods: Two kinds of metal alloys were analyzed. One was Ticonium 100 for removable prosthesis and the other was Rexillium V for dental porcelain. Two samples of each metal alloy were made in 0.5g, 1.0g, and 1.5g. Total number of samples were 12. Two kinds of lactic acid Solution, pH7 and pH4.6, were injected into each samples. After injection, each samples had been for 21days ${\pm}$ 1 hour in the water tank of which temperature was $37^{\circ}C$. The level of metal was measured in each sample by inductively couplled plasma-atomic emission spectrometer. Results: In both metal alloys, metals, chrome, nickel, beryllium, and molybdenum, were founded. In Ticonium 1000, the highest level of nickel was 2.531ppm in 1.5g pH4.6 sample while the highest level of nickel was 4.062ppm in 1.5g pH4.6 sample of Rexillium V. In chemical composition of these methal alloys, chrome(14~17%) was much more than beryllium(1.95~1.99%) and molybdenum(5.0~9.0%) but berllium and molybdenum were founded more than chrome in samples. Therefore, chrome showed better anti-corrosion than other metal alloys. In both metal alloys, more metals were founded in higher pH level and more mass. Levels of chrome was significantly different in samples of both metal alloys in each pH level(p<0.05). Levels of nickels was significantly different in samples of both metal alloys in each pH level(p<0.05). Conclusion: For oral health, further studies are needed in nickel-chrome metal alloy and cobalt metal alloy of non-beryllium in addittion to beryllium metal alloy and also long-term studies needed in various period and other non-percious metal alloys for dental casting.

Rubidium Market Trends, Recovery Technologies, and the Relevant Future Countermeasures (루비듐 시장 및 회수 동향에 따른 향후 관련 대응방안)

  • Sang-hun Lee
    • Resources Recycling
    • /
    • v.32 no.3
    • /
    • pp.3-8
    • /
    • 2023
  • This study discussed production, demand, and future prospects of rubidium, which is an alkali group metal that is highly reactive to various media and requires carefulness in handling, but no significant environmental hazard of rubidium has been reported yet. Rubidium is used in various fields such as optoelectronic equipment, biomedical, and chemical industries. Because of difficulty in production as well as limited demand, the transaction price of rubidium is relatively high, but its detail information such as market status and potential growth is uncertain. However, if the mass production of versatile ultra-high-performance equipment such as quantum computers and the necessity of rubidium use in the equipment are confirmed, there is a possibility that the rubidium market will expand in the future. Rubidium is often found together with lithium, beryllium, and cesium, and may be present in granite containing minerals such as lepidolite and pollucite, as well as in seawater and industrial waste. Several technologies such as acid leaching, roasting, solvent extraction, and adsorption are used to recover rubidium. The maximum recovery efficiency of the rubidium from the sources and the processing above is generally high, but, in many practices, rubidium is not the main recovery target, and therefore the actual recovery effects should depend on presence of other valuable components or impurities, together with recovery costs, energy consumption, environmental issues, etc. In conclusion, although the current production and consumption of rubidium are limited, with consideration of the possible market fluctuations according to the emergence of large-scale demand sources, etc., further investigations by related institutions should be necessary.

Evaluation of Biological Characteristics of Neutron Beam Generated from MC50 Cyclotron (MC50 싸이클로트론에서 생성되는 중성자선의 생물학적 특성의 평가)

  • Eom, Keun-Yong;Park, Hye-Jin;Huh, Soon-Nyung;Ye, Sung-Joon;Lee, Dong-Han;Park, Suk-Won;Wu, Hong-Gyun
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.280-284
    • /
    • 2006
  • $\underline{Purpose}$: To evaluate biological characteristics of neutron beam generated by MC50 cyclotron located in the Korea Institute of Radiological and Medical Sciences (KIRAMS). $\underline{Materials\;and\;Methods}$: The neutron beams generated with 15 mm Beryllium target hit by 35 MeV proton beam was used and dosimetry data was measured before in-vitro study. We irradiated 0, 1, 2, 3, 4 and 5 Gy of neutron beam to EMT-6 cell line and surviving fraction (SF) was measured. The SF curve was also examined at the same dose when applying lead shielding to avoid gamma ray component. In the X-ray experiment, SF curve was obtained after irradiation of 0, 2, 5, 10, and 15 Gy. $\underline{Results}$: The neutron beams have 84% of neutron and 16% of gamma component at the depth of 2 cm with the field size of $26{\times}26\;cm^2$, beam current $20\;{\mu}A$, and dose rate of 9.25 cGy/min. The SF curve from X-ray, when fitted to linear-quadratic (LQ) model, had 0.611 as ${\alpha}/{\beta}$ ratio (${\alpha}=0.0204,\;{\beta}=0.0334,\;R^2=0.999$, respectively). The SF curve from neutron beam had shoulders at low dose area and fitted well to LQ model with the value of $R^2$ exceeding 0.99 in all experiments. The mean value of alpha and beta were -0.315 (range, $-0.254{\sim}-0.360$) and 0.247 ($0.220{\sim}0.262$), respectively. The addition of lead shielding resulted in no straightening of SF curve and shoulders in low dose area still existed. The RBE of neutron beam was in range of $2.07{\sim}2.19$ with SF=0.1 and $2.21{\sim}2.35$ with SF=0.01, respectively. $\underline{Conclusion}$: The neutron beam from MC50 cyclotron has significant amount of gamma component and this may have contributed to form the shoulder of survival curve. The RBE of neutron beam generated by MC50 was about 2.2.