• 제목/요약/키워드: 베릴륨

검색결과 37건 처리시간 0.026초

베릴륨이 포함되지 않은 도재용착주조관용 비 귀금속 합금의 재사용에 따른 금속과 도재간의 전단결합강도에 관한 연구 (The study of Shear Bond Strength on recasting of non-beryllium non-precious alloy for Porcelain between Metal)

  • 김소리;김웅철;김혜영;김지환
    • 대한치과기공학회지
    • /
    • 제35권1호
    • /
    • pp.43-48
    • /
    • 2013
  • Purpose: This study aimed to investigate the shear bond strength for non-precious alloy castings without beryllium, which has been used repeatedly for economical reason. Methods: The Schmitz-Schulmeyer test method was used to evaluate the shear bond strength between the non-beryllium Ni-Cr alloy Vera Bond 2V(AlbaDent, Inc. USA) and the Ceramco 3(Dentstply, York, PA, USA) porcelain powder. The maximum loading and shear bond strength were measured. The average shear strength(MPa) was analyzed with the one-way ANOVA and the Tukey's test( =.05). The fracture specimens were examined using Microscope to determine the failure pattern. Results: The mean shear bond strengths(SD) in MPa were group A(100% new metal) control 28.72(3.31); group B(50% new + 50% reused) 27.28(1.13); group C(all reused) 26.61(5.47). Microscope examination showed that group A and B specimens presented mixed failure, and group C specimens showed adhesive failure. Conclusion: In conclusion, forward this non-precious alloy dose not contain beryllium for how should use a more systematic study and for future advanced research is performed giving effect to be considered desirable.

지자기 방향변화 및 베릴륨 동위원소비를 이용한 북동 적도 태평양 주상시료의 층서확립 (Stratigraphy of a Sediment Core Collected from the NE Equatorial Pacific Using Reversal Patterns of Geomagnetic Field and Be Isotope Ratio)

  • 김원년;형기성;공기수
    • Ocean and Polar Research
    • /
    • 제36권4호
    • /
    • pp.395-405
    • /
    • 2014
  • A 570 cm-long sediment core was retrieved at $9^{\circ}57^{\prime}N$ and $131^{\circ}42^{\prime}W$ in 5,080 m water depth from the northeast equatorial Pacific and its stratigraphy was established with $^{10}Be/^9Be$ and paleomagnetic measurements. Successive AF demagnetization reveals eight geomagnetic field reversals. In the reference geologic time scale, the eight reversal events correspond to an age of about 4.5 Ma. However, $^{10}Be/^9Be$-based age yields 9.5 Ma at a depth of 372 cm. Such a large discrepancy in determined ages is attributed to an extremely low sedimentation rate, 0.4 mm/kyr on average, of the study core and resultant loss or smoothing of geomagnetic fields. The composite age model reveals a wide range in the sedimentation rate - varying from 0.1 to 2.4 mm/kyr. However, the sedimentation rate shows systematic variation depending on sedimentary facies (Unit II and III), which suggests that each lithologic unit has a unique provenance and transport mechanism. At depths of 110-80 cm with a sedimentation rate of about 0.1 mm/kyr, ancient geomagnetic field reversal events of at least a 1.8 Myr time span have not been recorded, which indicates the probable existence of a hiatus in the interval. Such a sedimentary hiatus is observed widely in the deep-sea sediments of the NE equatorial Pacific.

오염원 인근 토양 중 베릴륨(Be), 코발트(Co), 탈륨(Tl), 바나듐(V)의 농도분포 및 오염영향 평가 (Evaluation of the Concentration Distribution and the Contamination Influences for Beryllium, Cobalt, Thallium and Vanadium in Soil Around the Contaminated Sources)

  • 이홍길;노회정;윤정기;임종환;임가희;김현구;김지인
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제23권4호
    • /
    • pp.48-59
    • /
    • 2018
  • Beryllium (Be), cobalt (Co), thallium (Tl) and vanadium (V) are candidates of 21 priority soil pollutants in Korea. The distribution of their concentration in soils from three contamination sources including industrial, roadside and mining areas was investigated. Concentrations of the metals were evaluated quantitatively using pollution indices and the fractionation of metals was conducted using modified SM&T (Standards Measurements and Testing programme) sequential extraction. Concentrations of the metals for all samples from industrial and roadside soils were within the range of natural background levels, while some of Be in soils from abandoned mines exceeded that the range. Enrichment Factor (EF) and Nemerow Integrated Pollution Index (NIPI) for Be, Co, Tl and V showed that there are effects or possibilities of anthropogenic activities. Pollution Load Index (PLI) analyses indicated all investigated sites needed further monitoring. The results of sequential extractions indicated mobile fractions (F1+F2) of Be, Tl and V were below 30% except some of Co in soil, which implies their low mobility to neighboring environment media. Variable tools like sequential extraction, comparison with background/actual concentration and pollution indices, as well as aqua regia extraction should be considered when evaluating Be, Co, Tl, V in soil.

새로운 금속 킬레이트 착물 발광체의 합성과 전기화학적 특성 연구 (Synthesis and Electrochemical Characterization of The New Luminescent Metal-Chelate Complexes)

  • 박지영;최돈수;김영관;하윤경
    • 대한화학회지
    • /
    • 제44권3호
    • /
    • pp.243-248
    • /
    • 2000
  • 다층 구조로 이루어진 유기 전계발광소자(OELD)는 평판 디스플레이에 응용될 수 있으므로 활발히 연구되고 있다. 금속 킬레이트 착물은 발광층을 구성하는 물질로 개발되고 있는데 이 중 몇 가지는 효율적인 전계발광(EL) 특성을 가진다고 알려져 있다. 본 연구에서는 청색 발광을 나타내는 몇 가지 금속 킬레이트 착물들을 합성하였다. 리간드 quinaldat나 8-quinoline carboxylate를 사용하였고 중심 금속으로는 베릴륨과 아연을 도입하였다. 이 착물들에 대하여 FT-IR, MS/FAB, $^1$H-NMR, UVvis, 광발광(PL) 특 성을 고찰하였다. 또한 순환 전압전류법(CV)으로 이들 착물로 형성된 필름의 전기화학적 밴드갭(Eg), 전자친화도(EA), 이온화 에너지(IP)를 조사하였다. 앞에서 얻은 UV-vis의 에너지 홉수 파장과 순환 전압전류법으로 구한 전기화학적 밴드갭올 비교, 논의하였다. 이러한 연구는 새로운 고효율 금속 착물 발광체의 개발에 밑거름이 될 것이며, 현재 이들 화합물로 EL 소자를 제작하는 연구가 진행 중에 있다.

  • PDF

베릴륨이 함유되지 않은 니켈-크롬 합금 코어와 코발트-크롬 합금 코어의 적합도 비교평가 (Comparison of the marginal and internal fit of cores fabricated by Ni-Cr alloy(non-beryllium) and Co-Cr alloy)

  • 김기백;김재홍;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제34권4호
    • /
    • pp.353-359
    • /
    • 2012
  • Purpose: The aim of this study measured and compared the marginal and internal fit of metal cores with two base metal alloy (Ni-Cr alloy(non-beryllium), Co-Cr alloy). Methods: Maxillary right first molar abutment fabricated by titanium was prepared for this study. Impressions(10ea) were made from titanium model, and study models were poured with improved dental stone. Wax cores of twenty were prepared for burn-out and casting. Ten wax cores cast Ni-Cr alloy(non-Be), and finally ten cast Co-Cr alloy. Marginal and internal fit of cores was evaluated using silicone replica technique and digital microscope(x160). The data were statistically analyzed with the independent samples t-test (${\alpha}$ <.05). Results: Mean(standard deviation, SD) marginal and internal fit total size of Ni-Cr alloy(non-Be) group was $73.3(14.4){\mu}m$ and of Co-Cr alloy group $65.6(17.4){\mu}m$. The marginal and internal fit total size of Ni-Cr alloy group(non-Be) was statistically significantly greater than that of Co-Cr alloy group (P=.004). Conclusion: Co-Cr alloy cores in this study had a better marginal fit than Ni-Cr alloy(non-Be) cores.

베릴륨 불포함 치과 주조용 니켈-크롬 합금 중 금속의치상용 합금과 금속소부도재관용 합금의 부식에 관한연구 (Corrosion of the non-beryllium dental casting Ni-Cr alloys for the denture base framework metal and the porcelain-fused-to-metal crown)

  • 김홍식;송재상;박수철
    • 대한치과기공학회지
    • /
    • 제34권4호
    • /
    • pp.337-344
    • /
    • 2012
  • Purpose: This study examined the corrosion level by alloy type and pH, and used the corrosion levels as the dental health data. The study utilized one Ni-Cr alloy for the full and removable partial denture metal frameworks and two Ni-Cr alloys for porcelain-fused-to-metal crown, among the non-beryllium dental casting non-precious Ni-Cr alloys. Methods: The alloy specimens were manufactured in $10cm^2$ and stored in the corrosive solution(pH 2.2-4.4) in the electrical water bath($37^{\circ}C$) for seven days. Afterwards, the metal ions were quantitatively analyzed using the ICP. Results: Of the three metal alloys, Bellabond-Plus$^{(R)}$alloy and SOLIBOND N$^{(R)}$alloy, with 22% or higher chrome chemical contents, had higher corrosion resistance than Jdium-100$^{(R)}$alloy with 20% chrome chemical content. In all three alloys, the corrosion of Ni was highest, and metal ion corrosion was higher in the pH 2.2 corrosive solution. Conclusion: Although Ni-Cr alloy was not very corrosive, a Ni-allergic patient should not have Ni-Cr alloy prosthesis. The Ni-Cr alloy for porcelain-fused-to-metal crown should be designed for the dental porcelain to cover the whole crown.

장반감기 우주선유발 동위원소, $^{10}Be$과 그 응용 (Long-lived cosmogenic nuclide, Beryllium-10 and its applications)

  • 김경자;;우형주
    • 한국제4기학회지
    • /
    • 제20권2호
    • /
    • pp.30-50
    • /
    • 2006
  • 반감기가 긴 $^{10}Be$ (Beryllium-10)은 지구의 대기뿐만 아니라, 지구의 표면 그리고 다른 행성의 대기와 표면에서도 생성된다. 가속기질량분석기술(AMS)이 1970년 후반기에 개발되면서 지질분야 연구에서 매우 중요한 추적자 중의 하나인 $^{10}Be$ 측정이 가능해졌으며, 이후 지구와 지구외 시료를 이용한 다양한 $^{10}Be$ 응용연구가 방사성탄소 응용연구와 함께 이루어져 왔다. 본 논문은 지구와 행성의 대기와 표면에서의 $^{10}Be$ 생성에 관한 메카니즘과 지형학, 해양학, 고고학, 빙하학, 우주방사화학, 기후학, 그리고 행성학 등의 여러 학문 분야에서의 $^{10}Be$의 응용연구들에 대하여 정리하였으며, 아울러 $^{10}Be$ 가속기질량분석을 이용한 향후 연구과제들을 고찰하였다.

  • PDF

50 MeV 사이클로트론 조사 서비스로 인한 방사화 평가 (Evaluating Activation for 50 MeV Cyclotron Irradiation Service using Monte Carlo Method and Inventory Code)

  • 김상록;김기섭;허재승;안윤진
    • 한국방사선학회논문지
    • /
    • 제15권4호
    • /
    • pp.415-427
    • /
    • 2021
  • 한국원자력의학원에서는 50 MeV 사이클로트론의 빔 라인을 이용하여 연구자들에게 다양한 빔 조사 서비스를 수행하고 있다. 특히 중성자 빔 서비스는 양성자와 베릴륨의 핵반응을 이용하기 때문에 높은 전류를 사용하므로 조사 시료의 방사화 가능성이 높아진다. 본 연구에서는 연구자들이 선호하는 35 MeV 20 ㎂ 중성자 빔 서비스에 의해 발생 가능한 방사화에 대해 MCNP 6.2와 FISPACT-II 4.0을 이용해 평가했다. 평가결과 철, 구리, 텅스텐 시료는 1시간 이상 조사하는 경우 장반감기 핵종이 생성되는 방사화가 발생하여 자체처분농도를 초과했다. 매일 2시간 사용 조건에서 건축물에 대한 방사화는 발생하지 않았고 조사실 내부 공기의 방사화로 인한 종사자의 내부피폭은 매우 미비했고, 이 공기를 배기하는 경우 배출기준도 만족했다.

도재용착용 Non beryllium 합금의 degassing과 opaque의 소성술식에 따른 결합강도 분석 (Shear bond strength analysis of non beryllium PFM metal with degassing and opaque firing techniques)

  • 임중재;이상혁
    • 한국산학기술학회논문지
    • /
    • 제16권7호
    • /
    • pp.4357-4363
    • /
    • 2015
  • 본 연구는 베릴륨 함유하지 않은 Ni-Cr계 도재용 금속에 전용도재를 도포, 소성된 시편을 3점 굴곡 시험으로 결합강도를 측정하고, SAM/EDS로 표면성분관찰 실험한 AVOVA와 Tukey HSAD 사후검정을 실시한 결과는 다음과 같은 결론을 얻었다. 첫째. 모든 군에서 ISO 9693의 치과용 금속-도재 시편의 최소 결합강도의 최소치인 25 MPa의 전단결합강도를 상위하며 안정적인 결과값을 나타냈다. 둘째. 결합 강도는 대조군 V1은 $32.37{\pm}1.91MPa$으로 나타났고, 실험군 V2 $38.25{\pm}1.38MPa$, 실험군 V3 $46.43{\pm}2.14MPa$, 그리고 실험군 V4 $47.21{\pm}1.72MPa$, 순으로 나타났으며 통계적으로 유의한 차이를 보였다. 사후 검정 (Tukey's HSD test) 결과, 결합강도 실험결과 실험군 V4는, 대조군 V1보다 높게 나타났다. 셋째. 금속-도재의 결합에서 산화처리를 시행한 군보다 시행하지 않고 불투명 도재를 도포하고 소성한 군이 높게 나타났으며, paste불투명 도재보다 분말 불투명도재의 사용에 따른 결합강도가 더 높게 나타났다. 넷째. 실험군 V4는 금속과 도재의 결합강도 비교에서 가장 높게 나타났다.

탄소나노튜브를 이용한 고휘도 마이크로빔 X-선원 발생부 설계 (Design of X-ray Target for a CNT-based High-brightness Microfocus X-ray Tube)

  • ;김선규;허성환;조성오
    • 한국진공학회지
    • /
    • 제15권1호
    • /
    • pp.103-109
    • /
    • 2006
  • 전자빔원으로 탄소나노튜브에 기초를 두고 있는 고휘도 마이크로빔 X선원용 타첫이 설계되었다. X-선원은 다음과 같은 제원을 따른다. $1\times10^{11} phs/s.mm^2.mrad^2$. 고휘도, 5 mm의 빔의 크기, $20\~40keV$ 평균 X-선 에너지. 제원을 만족시키기 위해서 구성, 물질, 타겟의 두께와 필요한 빔전류와 같은 타켓의 설계 변수들은 MCNPX code를 통해서 최적화되었다. 설계 변수들은 투과형 타겟 구조를 위해 X-선원의 스펙트럼과 세기의 분포의 계산으로부터 결정되었다 진공압력과 국소화된 열의 누적을 견디기 위한 투과형 타겟 구조를 위해서 구조적인 안정성과 온도 분포도 또한 고려되었다. 타겟 물질은 몰리보덴으로 선택되었고 최적화된 두께는 2mm로서 150mm 두께의 베릴륨이 붙여져 있다 부가적으로 투과형 타겟의 최대 온도가 안정적인 작동의 한계 내에서 유지될 수 있다는 것을 계산을 통하여 알게 되었다.