• Title/Summary/Keyword: 범위주기

Search Result 811, Processing Time 0.036 seconds

The Research of Comparison Evaluation on the Decline in Artifact Using Respiratory Gating System in PET-CT (PET-CT 검사 시 호흡동조 시스템을 이용한 인공물 감소에 대한 비교 평가)

  • Kim, Jin-Young;Lee, Seung Jae;jung, Suk;Park, Min-Soo;Kang, Chun-Goo;Im, Han-Sang;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.63-67
    • /
    • 2015
  • Purpose Among various causes that influence image quality degradation, various methods for decrease in Artifact occurred by respiration of patients are being used. Among them, this study intended to evaluate CTAC Shift correction method and additional scan compare to the Scan(Q static scan) using respiratory gated system. Materials and Methods This study was conducted on 10 patients, and used PET-CT Discovery 710 (GE Healthcare, MI, USA) and Varian's RPM system. 5.18 Mbq per kg of $^{18}F$-FDG was injected on patients, asked them to take a rest for 1 hour in the bed, and conducted test after urination. Images were visualized through Q static scan, CTAC Shift correction method, Additional scan based on the Whole body scan(WBS) with Artifact. Decrease in Artifact was compared in each image, conducted Gross Evalution, and measured changes of SUVmax. Results For image obtained through the CTAC Shift correction method through WBS with Artifact, 12~56%, Q static scan image showed 17~54% of change rate and Additional Scan showed -27~46% of change rate. In Blind Test, the CTAC Shift correction image showed the highest point with 4 points, Q static scan image showed 3.5 points, and Additional scan image showed 3.4 points. The standardized WBS scan through Oneway ANOVA and three types of Scan method showed significant difference(p<0.05), and did not show significant difference between the three Scan methods(p>0.05). However, the three Scan methods showed significant difference in Blind test. Conclusion Additional scan and Q static scan require more time than the CTAC Shift correction method, there is concern about excessive exposure to patients by CT rescan and Q static scan is difficult to apply on patients with inconsistent respiration or irregular respiration cycle due to pain. For CTAC Shift correction method, limited correction is possible and the range is limited as well. It is considered as a useful method of improving diagnostic value when hospitals use the system appropriately and develop various advantageous factors of each method.

  • PDF

A Study of the Core Factors Affecting the Performance of Technology Management of Inno-Biz SMEs (기술혁신형(Inno-Biz) 중소기업의 기술경영성과에 미치는 핵심요인에 관한 연구)

  • Yoon, Heon-Deok;Seo, Ri-Bin
    • Journal of Technology Innovation
    • /
    • v.19 no.1
    • /
    • pp.111-144
    • /
    • 2011
  • This study is to confirm the core factors of innovative capabilities and technological entrepreneurship affecting the performance of technology management and business management of small and medium-sized enterprises (SMEs). Through the consideration about the complex natures of technological innovation affecting by multidimensional factors, this study designs the research model that innovative capabilities, the performances of technology and business management are arranged in accordance with the innovation process; input-output-outcome. To meet this research purpose, the hypothesis are set up based on the previous research studies and the research samples are selected from members of the Innovative Business (INNO-BIZ) Association, located in Seoul and Geyonggi province. As a result of regression analysis to the responses gathered from 360 firms, the performance of business management is influenced positively by the technology superiority, market growth and business profitability which are the dominant factors of performance of technology management. In addition, three sub-variables of innovative capabilities such as R&D, strategic planning and learning capability, have positive effects on both the managerial performances. Innovativeness and progressiveness of technological entrepreneurship affect both the performances positively. Moreover, the co-relation between technological entrepreneurship of an innovation leader and innovative capabilities of organizational members are identified. Lastly, technological entrepreneurship has the mediating effect on the path of leading innovative capabilities to the managerial performances. In conclusion, the research results imply that technological innovation-type firms should periodically evaluate the performance of technology management which are the output of technological innovations and the reinvestment for ultimate business success. And improving and developing innovative capabilities and technological entrepreneurship is required to continuously and consistently investing and supporting resources on technological innovations at the firm-and government-level. It is considered that these are the crucial methods for securing the technologically competitive advantage of SMEs with less resources and narrow innovation range.

  • PDF

Immunomodulatory Activities by Difference in Molecular Size of the Proteoglycan Extracted from Ganoderma lucidum IY009 (Ganoderma lucium IY009 유래 단백다당류의 분자량 차이에 따른 면역증강활성)

  • Lee, June-Woo;Baek, Seong-Jin;Bang, Kwang-Woong;Kim, Yong-Seuk;Kim, Kwang-Soo;Chun, Uck-Han
    • The Korean Journal of Mycology
    • /
    • v.29 no.1
    • /
    • pp.15-21
    • /
    • 2001
  • This study was conducted to investigate the immunomodulatory activities of proteoglycan extracted from cultured mycelia of Ganoderma lucidum IY009. The proteoglycan contained two polymer peaks, one was the higher MW peak of 2,000 kD and the other was low peaks of 12kD. To understand the part of strong pharmaceutical activity between two peak, the proteoglycan was separated by ultrafiltration and column chromatography and then examined the various pharmaceutical effects. High molecular weight fraction possesing high content of ${\beta}-linked$ glucan was exhibited high antitumor activity, against sarcoma 180 bearing ICR mouse. And also, anticomplementary activity was highly observed in high molecule fraction than low it fraction. When the raw 264.7 and murine peritoneal macrophage treated with low fraction, high fraction and other stimuli. The activities inducing tumor necrosis factor of the high factions were $2.2{\sim}2.5$ times stronger than that of low fraction.

  • PDF

A Product Model Centered Integration Methodology for Design and Construction Information (프로덕트 모델 중심의 설계, 시공 정보 통합 방법론)

  • Lee Keun-Hyoung;Kim Jae-Jun
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.99-106
    • /
    • 2002
  • Researches on integration of design and construction information from earlier era focused on the conceptual data models. Development and prevalent use of commercial database management system led many researchers to design database schemas for enlightening of relationship between non-graphic data items. Although these researches became the foundation fur the proceeding researches. they did not utilize the graphic data providable from CAD system which is already widely used. 4D CAD concept suggests a way of integrating graphic data with schedule data. Although this integration provided a new possibility for integration, there exists a limitation in data dependency on a specific application. This research suggests a new approach on integration for design and construction information, 'Product Model Centered Integration Methodology'. This methodology achieves integration by preliminary research on existing methodology using 4D CAD concept. and by development and application of new integration methodology, 'Product Model Centered Integration Methodology'. 'Design Component' can be converted into digital format by object based CAD system. 'Unified Object-based Graphic Modeling' shows how to model graphic product model using CAD system. Possibility of reusing design information in latter stage depends on the ways of creating CAD model, so modeling guidelines and specifications are suggested. Then prototype system for integration management, and exchange are presented, using 'Product Frameworker', and 'Product Database' which also supports multiple-viewpoints. 'Product Data Model' is designed, and main data workflows are represented using 'Activity Diagram', one of UML diagrams. These can be used for writing programming codes and developing prototype in order to automatically create activity items in actual schedule management system. Through validation processes, 'Product Model Centered Integration Methodology' is suggested as the new approach for integration of design and construction information.

  • PDF

Comparison of Multi-Satellite Sea Surface Temperatures and In-situ Temperatures from Ieodo Ocean Research Station (이어도 해양과학기지 관측 수온과 위성 해수면온도 합성장 자료와의 비교)

  • Woo, Hye-Jin;Park, Kyung-Ae;Choi, Do-Young;Byun, Do-Seung;Jeong, Kwang-Yeong;Lee, Eun-Il
    • Journal of the Korean earth science society
    • /
    • v.40 no.6
    • /
    • pp.613-623
    • /
    • 2019
  • Over the past decades, daily sea surface temperature (SST) composite data have been produced using periodically and extensively observed satellite SST data, and have been used for a variety of purposes, including climate change monitoring and oceanic and atmospheric forecasting. In this study, we evaluated the accuracy and analyzed the error characteristic of the SST composite data in the sea around the Korean Peninsula for optimal utilization in the regional seas. We evaluated the four types of multi-satellite SST composite data including OSTIA (Operational Sea Surface Temperature and Sea Ice Analysis), OISST (Optimum Interpolation Sea Surface Temperature), CMC (Canadian Meteorological Centre) SST, and MURSST (Multi-scale Ultra-high Resolution Sea Surface Temperature) collected from January 2016 to December 2016 by using in-situ temperature data measured from the Ieodo Ocean Research Station (IORS). Each SST composite data showed biases of the minimum of 0.12℃ (OISST) and the maximum of 0.55℃ (MURSST) and root mean square errors (RMSE) of the minimum of 0.77℃ (CMC SST) and the maximum of 0.96℃ (MURSST) for the in-situ temperature measurements from the IORS. Inter-comparison between the SST composite fields exhibited biases of -0.38-0.38℃ and RMSE of 0.55-0.82℃. The OSTIA and CMC SST data showed the smallest error while the OISST and MURSST data showed the most obvious error. The results of comparing time series by extracting the SST data at the closest point to the IORS showed that there was an apparent seasonal variation not only in the in-situ temperature from the IORS but also in all the SST composite data. In spring, however, SST composite data tended to be overestimated compared to the in-situ temperature observed from the IORS.

Development and Feasibility Study for Phase Contrast MR Angiography at Low Tesla Open-MRI System (저자장 자기공명영상 시스템에서의 위상대조도 혈관조영기법의 개발과 그 유용성에 대한 연구)

  • Lee, Dong-Hoon;Hong, Cheol-Pyo;Lee, Man-Woo;Han, Bong-Soo
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.177-187
    • /
    • 2012
  • Magnetic resonance angiography (MRA) techniques are widely used in diagnosis of vascular disorders such as hemadostenosis and aneurism. Especially, phase contrast (PC) MRA technique, which is a typical non contrast-enhanced MRA technique, provides not only the anatomy of blood vessels but also flow velocity. In this study, we developed the 2- and 3-dimensional PC MRA pulse sequences for a low magnetic field MRI system. Vessel images were acquired using 2D and 3D PC MRA and the velocities of the blood flow were measured in the superior sagittal sinus, straight sinus and the confluence of the two. The 2D PC MRA provided the good quality of vascular images for large vessels but the poor quality for small ones. Although 3D PC MRA gave more improved visualization of small vessels than 2D PC MRA, the image quality was not enough to be used for diagnosis of the small vessels due to the low SNR and field homogeneity of the low field MRI system. The measured blood velocities were $25.46{\pm}0.73cm/sec$, $24.02{\pm}0.34cm/sec$ and $26.15{\pm}1.50cm/sec$ in the superior sagittal sinus, straight sinus and the confluence of the two, respectively, which showed good agreement with the previous experimental values. Thus, the developed PC MRA technique for low field MRI system is expected to provide the useful velocity information to diagnose the large brain vessels.

Development of Preliminary Quality Assurance Software for $GafChromic^{(R)}$ EBT2 Film Dosimetry ($GafChromic^{(R)}$ EBT2 Film Dosimetry를 위한 품질 관리용 초기 프로그램 개발)

  • Park, Ji-Yeon;Lee, Jeong-Woo;Choi, Kyoung-Sik;Hong, Semie;Park, Byung-Moon;Bae, Yong-Ki;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.113-119
    • /
    • 2010
  • Software for GafChromic EBT2 film dosimetry was developed in this study. The software provides film calibration functions based on color channels, which are categorized depending on the colors red, green, blue, and gray. Evaluations of the correction effects for light scattering of a flat-bed scanner and thickness differences of the active layer are available. Dosimetric results from EBT2 films can be compared with those from the treatment planning system ECLIPSE or the two-dimensional ionization chamber array MatriXX. Dose verification using EBT2 films is implemented by carrying out the following procedures: file import, noise filtering, background correction and active layer correction, dose calculation, and evaluation. The relative and absolute background corrections are selectively applied. The calibration results and fitting equation for the sensitometric curve are exported to files. After two different types of dose matrixes are aligned through the interpolation of spatial pixel spacing, interactive translation, and rotation, profiles and isodose curves are compared. In addition, the gamma index and gamma histogram are analyzed according to the determined criteria of distance-to-agreement and dose difference. The performance evaluations were achieved by dose verification in the $60^{\circ}$-enhanced dynamic wedged field and intensity-modulated (IM) beams for prostate cancer. All pass ratios for the two types of tests showed more than 99% in the evaluation, and a gamma histogram with 3 mm and 3% criteria was used. The software was developed for use in routine periodic quality assurance and complex IM beam verification. It can also be used as a dedicated radiochromic film software tool for analyzing dose distribution.

The Study of Factor Concerning Ovum Pick-up and Conception Rate by Ultrasound-Guided Follicular Aspiration in Hanwoo Heifers (한우에 있어서 초음파기기를 이용한 생체내 난자 채취시 채란조건 및 수태율에 관한 연구)

  • 박성재;양보석;임기순;성환후;장원경;정일정;박충생
    • Korean Journal of Animal Reproduction
    • /
    • v.24 no.2
    • /
    • pp.199-208
    • /
    • 2000
  • This study was carried out to investigate of factors concerning to ultrasound-guided follicular aspiration; level of vacuum pressure, diameter of use needle, effect of FSH hormone and conception rate after embryos transfer. 1. Oocytes collection number were 4.2$\pm$2.9 e.a to luteuml phase and follicular phase were 4.4$\pm$3.5 e.a to ovaries of Hanwoo. 2. We taked proper level of aspiration vacuum pressure was 40~120 mmHg to oocytes collection. Oocytes collected number were 4.2$\pm$3.2, 4.3$\pm$3.4, 4.5$\pm$3.4 e.a. to 40, 80, 120mmHg, respectively, follicles aspiration rate were 49, 47, 45%. 3. Effect of collection needle diameter was not difference significantly(P<0.05), oocytes collected number were 4.4$\pm$3.5 e.a to 170 and 3.0$\pm$1.8 e.a to 18G needle, collected oocytes quality were no difference significantly (P<0.05). 4. Follicles increase number to FSH hormone injection were 6.2$\pm$2.3 e.a to intramuscle and 1.1$\pm$2.7 e.a. to epithelial injection method. 5. Conception rate derived from E.T. was 11.1% to freezing embryos and 46.2% to fresh E.T., difference significantly(P<0.05).

  • PDF

Evaluate the implementation of Volumetric Modulated Arc Therapy QA in the radiation therapy treatment according to Various factors by using the Portal Dosimetry (용적변조회전 방사선치료에서 Portal Dosimetry를 이용한 선량평가의 재현성 분석)

  • Kim, Se Hyeon;Bae, Sun Myung;Seo, Dong Rin;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.167-174
    • /
    • 2015
  • Purpose : The pre-treatment QA using Portal dosimetry for Volumetric Arc Therapy To analyze whether maintaining the reproducibility depending on various factors. Materials and Methods : Test was used for TrueBeam STx$^{TM}$ (Ver.1.5, Varian, USA). Varian Eclipse Treatment planning system(TPS) was used for planning with total of seven patients include head and neck cancer, lung cancer, prostate cancer, and cervical cancer was established for a Portal dosimetry QA plan. In order to measure these plans, Portal Dosimetry application (Ver.10) (Varian) and Portal Vision aS1000 Imager was used. Each Points of QA was determined by dividing, before and after morning treatment, and the after afternoon treatment ended (after 4 hours). Calibration of EPID(Dark field correction, Flood field correction, Dose normalization) was implemented before Every QA measure points. MLC initialize was implemented after each QA points and QA was retried. Also before QA measurements, Beam Ouput at the each of QA points was measured using the Water Phantom and Ionization chamber(IBA dosimetry, Germany). Results : The mean values of the Gamma pass rate(GPR, 3%, 3mm) for every patients between morning, afternoon and evening was 97.3%, 96.1%, 95.4% and the patient's showing maximum difference was 95.7%, 94.2% 93.7%. The mean value of GPR before and after EPID calibration were 95.94%, 96.01%. The mean value of Beam Output were 100.45%, 100.46%, 100.59% at each QA points. The mean value of GPR before and after MLC initialization were 95.83%, 96.40%. Conclusion : Maintain the reproducibility of the Portal Dosimetry as a VMAT QA tool required management of the various factors that can affect the dosimetry.

  • PDF

Treatment Outcome of Postoperative Radiotherapy in Extrahepatic Bile Duct Cancer (간외담관암의 수술 후 방사선치료 성적)

  • Choi, Young-Min;Cho, Heung-Lae
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.27-34
    • /
    • 2003
  • Purpose : To evaluate the efficacy of radiotherapy, and the factors affecting survival in patients of extrahepatic bile duct cancer, by analyzing the results of postoperative radiotherapy Materials and Methods : Between October 1991 and July 2001, 21 patients with extrahepatic bile duct cancer, who received radiotherapy after a radical resection, were retrospectively reviewed. The patients' ages ranged from 39 to 75 years, with a median of 61 years, and a male to female ratio of 16 to 5. The numbers of patients with proximal and distal bile duct cancer were 14 and 7, respectively. From the postoperative pathological examination, 19 of the patients were found to have microscopic residues, and 7 to be lymph node positive. Patients with AJCC stages I, II and III were 10, 10 and 1, respectively. The total radiation dose administered was 4,500$\~$6,300 cGy, with a median dose of 5,040 cGy. The follow up period was 20$\~$81 months, with a median of 57.5 months. Results : The overall and disease free survival rates at 3 and 5 years were 41.0 and 29.3$\%$, and 41.6 and 29.7$\%$, respectively. The influences of age, sex, tumor location, differentiation, microscopic residue, neural invasion, 7 and N stage, the stage itself, the dose of radiation and chemotherapy, on survival were evaluated. The T stage and the stage itself were found to be significant from a univariate analysis (p<0.05), but the degree of significance was limited by the small number of patients. A recurrence occurred in 12 patients (57.1$\%$), 5 in locoregional sites, 4 in distant sites and 3 in a combination of locoregional and distant sites, and the sites of distant metastasis were the liver, 6, and the bone, 1 Grade 2 or 3 acute leucopenias occurred in 2 patients and grade 2 chronic peptic ulcers occurred in 4, who were all recovered by conservative management. Conclusion : Postoperative radiotherapy is feasigbls in extrah데atic bile duct cancer, with tolerable toxicity, but prospective studies, with a large patient enrollment, are needed for the evaluation of the effects of postoperative radiotherapy and the related prognostic factors.