• Title/Summary/Keyword: 밸브 시스템

Search Result 850, Processing Time 0.024 seconds

Pressure Recovery in a Supersonic Ejector of a High Altitude Turbofan Engine Testing Chamber (터보팬 엔진의 고고도 성능의 초음속 이젝터의 압력회복에 관한 연구)

  • Omollo, Owino George;Kong, Chang-Duk
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.6
    • /
    • pp.53-59
    • /
    • 2010
  • This research aims in finding a more optimal ejector size for evacuating engine exhaust gasses and 20% of the cell cooling air. The remaining 80% of cell cooling air pumped into the test chamber is separately exhausted from the test chamber via a discharge port fitted with flow control valves and vacuum pump. Unlike its predecessor this configuration utilizes a smaller capture area to improve pressure recovery. The modified ejector size has a diameter of 1100mm enough to evacuate 66kg/s jet engine exhaust in addition to about 20%, 24kg/s of the cell cooling air tapped from the sterling chamber. This configurations has an area ratio of the engine exit and ejector inlet of about 1.2. Simulation results of the proposed ejector configuration, indicates improved pressure recovery.

Evaluation on Mechanical Properties of a Smart Composite Using the finite Element Method and the Acoustic Emission Technique (FEM과 AE를 이용한 지적복합재료의 기계적특성 평가)

  • Park, Young-Chul;Lee, Jin-Kyung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.3
    • /
    • pp.233-239
    • /
    • 2004
  • Smart material is used in various applications such as for glass frame, for medical instruments and for a part of sensors. Smart composite materials ran be applied to a part of aircraft and to the on-line monitoring system for industrial structures, using the shape memory effect. However, it is very difficult to simulate and analyze the shape memory effect in smart composites. In this paper, a two dimensional axisymmetric model was proposed to analyze the smart composite of one fiber and matrix using the finite element method(FEM). The finite element analysis was carried out in two renditions of the room temperature(293K) and a higher temperature (363K). The results we.e compared with the experimental results to confirm the validity of the analysis. In addition, the acoustic emission(AE) technique was used to study the microscopic damage behavior and the effect of pre-strains on TiNi/A16061 shape memory alloy composite.

Thermodynamic Analysis on Hybrid Molten Carbonate Fuel Cell - Turbo Expander System for Natural Gas Pressure Regulation (용융탄산염연료전지와 터보팽창기를 이용한 천연가스 정압기지의 열역학적 분석)

  • Sung, Taehong;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.2
    • /
    • pp.28-34
    • /
    • 2014
  • In the natural gas pressure regulation station, high pressure natural gas is decompressing using pressure regulation valves. Waste pressure occurred in the pressure regulation process can be recovered through adopting turbo expanders. However, in the waste pressure recovery process, Joule Thompson effect causes below $0^{\circ}C$ and this low temperature freezes outside land of pipeline or generates methane hydrate in the pipeline which can block the pipeline. Therefore, turbo expander systems are accompanying with a boiler for preheating natural gas. Molten carbonate fuel cell (MCFC), one of the high temperature fuel cell, can use natural gas as a direct fuel and is also exhausting low emission gas and generating electricity. In this paper, a thermodynamic analysis on the hybrid MCFC-turbo expander system is conducted. The fuel cell system is analyzed for the base load of the hybrid system.

Analysis of Character Types for FPS Game -based on Team Fortress2- (FPS 게임에서의 캐릭터 성격 분석 연구 -FPS 게임 팀 포트리스2를 중심으로-)

  • Park, Myoung-Hoon;Noh, Seung-Seok;Park, Jin-Wan
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.2
    • /
    • pp.152-161
    • /
    • 2011
  • The FPS, featured with high quality graphic of superior visual reality, is steadily growing because of the improvement of computer performance and technological advancement of game production. But most of the FPS games provide monotonous freedom with which players can only change the weapons in one character and this will make users lose their interests when playing games for long hours. Valve has introduced 'Team Fortress Classic' in 1999, in order to change the monotonous game methods. This game has attracted great attention because of the composition of various and unique characters through the introduction of military specialty system: that is the first trial in the history of FPS game. I, by analyzing this using MBTI, intend to analyze how much of immersion and interest the characters of various military specialties can provide to players when FPS games are developed.

Development of Intelligent IoT Exhaustion System for Bag Filter Collector (백필터 집진기의 지능형 IoT 탈진 시스템 개발)

  • Jang, Sung-Cheol;Lee, Jung-Won
    • Journal of Internet of Things and Convergence
    • /
    • v.5 no.1
    • /
    • pp.29-34
    • /
    • 2019
  • A bag filter collector is a kind of air purifier that organizes several or dozens of filters to purify fine dust and release clean air into the atmosphere. If the bag filter length is less than 5m, the dust and fume attached to the bag filter could be effectively removed by passing the compressed air generated by the diaphragm valve through the venturi. Injectors that are more efficient and economical are urgently needed to achieve satisfactory results for long-bag exhaustion of more than 7 meters. In the case of existing domestic and foreign injectors, a number of blow tubes were dismantled during maintenance, and the injector and blow tube were combined to pose a number of problems, including inconvenience of work due to weight increase. In this study, injector flow for the development of the best use of interpretation of the coanda effect and the fourth round of industrial technology Intelligent automation of exhaustion, have been engineered energy than standard equipment. lowering costs and filter life to radically improve the commercial studies.

A Study on a Precision Temperature Control of Oil Coolers with Hot-gas Bypass Manner for Machine Tools Based on Fuzzy Control (퍼지제어를 이용한 공작 기계용 오일 쿨러의 핫가스 바이패스방식 정밀 온도 제어에 관한 연구)

  • Lee, Sang-Yun
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.3
    • /
    • pp.205-211
    • /
    • 2013
  • Recently, the needs of system performances such as working speed and processing accuracy in machine tools have been increased. Especially, the working speed increment generates harmful heat at both moving part of the machine tools and handicrafts. The heat is a main drawback to progress accuracy of the processing. Hence, a oil cooler to control temperature is inevitable for the machine tools. In general, two representative control schemes, hot-gas bypass and variable speed control of a compressor, have been adopted in the oil cooler system. This paper deals with design and implementation method of fuzzy controller for obtaining precise temperature characteristic of HB oil cooler system in machine tools. The opening angle of an electronic expansion valve are controlled to keep reference value and room temperature of temperature at oil outlet. Especially, the fuzzy controller is added to suppress temperature fluctuation under abrupt disturbances. Through some experiments, the suggested method can control the target temperature within steady state error of ${\pm}0.22^{\circ}C$.

A Study on Dynamic Characteristics of Hydraulic Motor Brake System with Counter Balance Valve (카운터 밸런스 밸브를 내장한 유압 모터 브레이크 시스템의 동특성)

  • Yun, So-Nam;Lee, Ill-Yeong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.29 no.3
    • /
    • pp.214-219
    • /
    • 1993
  • Counter balance valve is used as one part of hydraulic motor brake system. The function of this valve is to protect over-run or free falling of inertia load. But occasionally the brake system with counter balance valve makes some undesirable problems such as pressure surges or vibrations. These problems may hurt system safety and driver's conformability. Nevertheless, studies on dynamic characteristics of hydraulic system including counter balance valve are very rare, so further accumulation of research results are required. In this study, for the purpose of easy estimation about dynamic characteristics of hydraulic system including counter balance valve, precise formulation describing fluid dynamics and valve dynamics under various boundary conditions were made. The equations obtained in the preceding process include some parameters that must be got experimentally. Flow coefficients of valve and choke are the most significant ones among the parameters. So these parameters are obtained experimentally in this study, and experimental equations obtained from the experimental data were used for numerical calculation. The equations were analysed by numerical integration using Runge-Kutta method, because the equations contain various nonlinear terms. From the numerical analysis, it was verified that the dynamic response of counter balance valve and pressure variation at each elements can be estimated very easily. So the analysing method developed in this study enabled very easy estimating the relation between the performances of counter balance valve and various physical parameters related to the valve. Conclusively, it is said that the results obtained in this study can be used very usefully to develop a new type counter balance valve or to apply the valve to actual hydraulic system for various industrial equipments.

  • PDF

진공펌프 배기속도 측정 방식에 따른 구조적 오차 및 보정

  • In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.169-169
    • /
    • 2011
  • 진공펌프의 성능을 나타내는 여러 파라미터가 있지만 가장 중요한 성능지표는 역시 배기속도라고 할 수 있다. 배기속도는 물리적으로 체적유량(volume flow rate, L/s 또는 m3/hr) 즉 단위시간당 펌프 흡기구에 들어오는 기체의 체적을 가리킨다. 펌프 흡기구 단면을 지나가는 체적을 직접 측정하는 것은 거의 불가능하므로 진공 전문가들은 흡기구로 들어가는 기체 유량(flow rate, mbar${\cdot}$L/s 또는 Pa${\cdot}$m3/s)과 흡기구 압력(mbar 또는 Pa)을 측정한 후 유량을 압력으로 나누어 주는 방식으로 배기속도를 측정한다. 유량은 표면 기체 방출을 고려하더라도 실용적인 측면에서 보면 위치에 상관없이 불변하는 값으로 볼 수 있어서 유량을 어떻게 정밀하게 잴 것인가 하는 방법만 있으면 편리한 위치에서 측정하면 된다. 반면에 압력을 정밀하게 측정하는 방식은 확립되어 있지만 막상 어디서 측정하는 것이 옳은가 하는 것은 의외로 쉽지 않다. 펌프의 배기속도를 측정하는 상황을 몇 가지로 가정해 보면, 규격에 입각한 표준용기에 달아 정식으로 재는 것, 게이지가 부착된 마구리판을 달고 간이로 재는 것, 펌프가 사용되고 있는 시스템 현장에서 재는 것이 있을 수 있고 펌프가 달려 있는 상태도 직접 용기에 달거나, 도관 또는 어댑터 및 밸브를 통해 달리는 경우가 있다. 앞에서 펌프 배기속도 계산 시 사용하는 흡기구 압력이란 엄밀히 말하면 흡기구를 바라보는 방향으로 가해지는 압력을 말하는데 이는 진공 게이지를 펌프 흡기구 면에서 상류를 향하도록 놓을 때 얻을 수 있는 값으로 막상 실행하는 것은 어렵다. 표준용기의 구조는 진공 게이지를 특정 위치에 달 때 마치 흡기구 면에 놓인 게이지처럼 흡기구 압력을 정확하게 측정할 수 있도록 고안된 것이지만 때에 따라서는 여러 변형된 측정 방식을 사용할 수밖에 없는 상황이 만들어지므로 어떤 보정을 거치면 올바른 배기속도 값을 구할 수 있는지 살펴볼 필요가 있다.

  • PDF

Stagnation of Droplet for Efficient Merging in Microfluidic System (미세유체의 효율적인 액적 합류를 위한 정체현상 조절)

  • Jin, Si Hyung;Kim, Jongmin;Jang, Sung-Chan;Noh, Young Moo;Lee, Chang-Soo
    • Korean Chemical Engineering Research
    • /
    • v.52 no.1
    • /
    • pp.106-112
    • /
    • 2014
  • Here, we demonstrated the optimum design of pillar microstructure for efficient microdroplet merging. The microfluidic device mainly consisted of programmable microvalves and pillar microstructures. Based on the system, aqueous droplets were continuously generated at T-junction using actuating of integrated programmable microvalaves under the immiscible continuous fluid (mineral oil containing 0.5 wt% Span 80). The principle of merging process depended on the competitive correlation of hydraulic pressure of continuous phase and Laplace pressure of the droplet. We found that the design of the micropillars controls above two pressures. Finally, it was demonstrated that the microfluidic system could be able to efficient biochemical reaction. We expect that the microfluidic system is useful analytical or reaction tools in fundamental science, biotechnology, and chemical engineering.

A Fuzzy Controller for the Steam Generator Water Level Control and Its Practical Self-Tuning Based on Performance (증기발생기 수위제어를 위한 퍼지제어기 구현 및 제어성능지수를 이용한 제어기 의 Self-Tuning)

  • Na, Nan-Ju;Bien, Zeun-Gnam
    • Nuclear Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.317-326
    • /
    • 1995
  • The oater level control system of the steam generator in a pressurized water reactor and its control Problems are analysed. In this work a stable control strategy Particularly during low Power operation based on the fuzzy control method is studied. The control strategy employs substitutional information using the bypass valve opening instead of incorrectly measured signal at the low How rate as the fuzzy variable of the flow rate during low power operation, and includes the flexible scale adjusting method for fast response at a large transient. A self-tuning algorithm based on the control performance and the descent method is also suggested for tuning the membership function scale. It gives a practical way to tune the controller under real operation. Simulation was carried out on the Compact Nuclear Simulator set up at Korea Atomic Energy Research Institute and its result showed the good performance of the controller and effectiveness of its tuning.

  • PDF