• Title/Summary/Keyword: 밸브 손실계수

Search Result 33, Processing Time 0.024 seconds

Evaluation of Loss Coefficient of a Butterfly Valve with Valve Closed Angles (밸브 닫힘각 변화에 따른 버터플라이밸브의 손실계수 평가)

  • Lee, Jee-Keun;Rho, Byung-Joon;Choi, Hee-Joo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.1
    • /
    • pp.14-21
    • /
    • 2008
  • In this study, flow characteristics of a small-sized butterfly valve with the valve disk diameter of 25.4 mm have been investigated experimentally for the valve closed angles. In order to examine the flow characteristics of the butterfly valve, loss coefficient (Kv) was obtained at the valve closed angles of 0$^{\circ}$, 5$^{\circ}$, 10$^{\circ}$, 20$^{\circ}$ and 30$^{\circ}$. In addition, the effects of the valve disk edge shape were examined. As the result of the experiment, the maximum loss coefficient (Kvmax) was decreased with the increase of the valve closed angle, and it had the maximum decrease ratio at the valve disk angles of 0$^{\circ}$~5$^{\circ}$. The valve disk edge shape have an effect on the loss coefficient of the valve around the small valve closed angle.

A Study on the Performance Analysis of Butterfly Valve in Water Fire Extinguishing System (수계소화시스템 버터플라이 밸브의 성능해석에 관한 연구)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.91-96
    • /
    • 2007
  • Performance analysis of the butterfly valve in water fire extinguishing has been carried out. Performance analysis of the butterfly valve are investigated for torque characteristics, pressure loss and cavitations. The torque characteristics of disc are corrected for the angles of attack of valve disc by theoretical torque equation, and correction equation is added. The pressure loss coefficient on opening angle of valve has been formulated by applying the Carnot's equations. The torque characteristics, pressure loss and cavitations of the butterfly valve are analyzed for the ratio of disc thickness to the valve diameter. Cavitations are analyzed from the pressure loss coefficient of valve. The analysis of pressure loss and cavitation has been carried out change of the thickness ratio on opening angle of valve. These analysis data are utilize to necessary engineering data to develope of the butterfly valve.

Study of Flow Control Range according to Valve Type (밸브 형식별 유량제어범위 결정에 관한 연구)

  • Park, Jong-Ho;Park, Han-Yung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.5
    • /
    • pp.39-47
    • /
    • 2011
  • Flow control range of valve, which is installed on pipeline, varies according to valve type, pipe diameter, pipe length, roughness, and elevation difference of both ends of pipeline. A lot of computation efforts and knowledge are needed to estimate flow control range of valve, considering above many parameters. The table of flow control range of each valve type is presented for convenience of pipeline design engineers who must make decision of valve size and type in this study. Also the reason that butterfly valve is recommended for flow control, and gate valve is forbidden is presented via quantification and figures in this study.

A Study on the Flow Characteristics of a Butterfly Valve in Fire Protection (소화용 버터플라이 밸브의 유동특성에 관한 연구)

  • 이동명;김엽래
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.59-64
    • /
    • 2002
  • Investigation of flow characteristics on pressure loss and cavitations of the butterfly valve has been carried out. The pressure loss coefficient on opening angle of valve has been formulated by applying the Carnot's equations. Cavitations (such as cavitation Inception, super cavitation inception, cavitation damage inception, choking cavitation) have been predicted from the pressure loss coefficient of valve. The prediction of pressure loss and cavitation has been carried out change of the thickness ratio on opening angle of valve. The prediction data is utilize to necessary engineering data to develope of the butterfly valve.

Study of Butterfly Valve Loss Coefficient Equation (버터플라이밸브 손실계수 표현식에 관한 연구)

  • Park, Jong-Ho;Park, Han-Yung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.4
    • /
    • pp.31-37
    • /
    • 2011
  • Linear curve or hyperbolic curve interpolation equations have been used to represent loss coefficient of butterfly valve according to a certain opening(for example, each 10 degree up to 90 degree) so far, and these equations are not precise and inconvenient to use with computer programming. Method of representing loss coefficient of butterfly valve using experiment data with several equations is presented and It is verified that log equation is most precise and convenient to use with computer programming in this research.

Study on the improvement in Cv of a Main Oxidizer shut-off Valve (CC 산화제 개폐밸브 유량계수 향상에 관한 연구)

  • Hong, Moon-Geun
    • Aerospace Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.140-148
    • /
    • 2009
  • MOV(Main Oxidizer shut-off Valves) control the combustion of launch vehicle systems by the supply and the isolation of liquid oxygen to a main combustion chamber in launch vehicle systems. Moreover, in the steady operational state, the MOV should secure a constant flow rate of liquid oxygen for combustion instability in the combustion chamber. Concerning the development of MOV, TM(Technology Model) has been manufactured and normal operations of the valve have been verified. However, the Cv of TM has been proved to be too low as compared with a design specification value. Therefore, CFD analysis have been performed by modification of the configurations of TM in order to increase sufficiently Cv of EM(Engineering Model), which is the following model of TM. The modifications of TM configurations such as partial scale-up of valve, increase of stroke length, and outlet angle of 120o would result in a considerable augmentation of Cv. It has been verified by flow capacity tests that the improved Cv of EM is min. 212, which is higher than Cv of TM, 161 by about 32%.

  • PDF

Study of Waterhammer Suppression Technique due to Valve Closing on Water Supply Pipeline (송수관로 밸브폐쇄에 따른 수충격현상 완화기법 연구)

  • Park, Jong-Ho;Park, Han-Yung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.6
    • /
    • pp.11-17
    • /
    • 2011
  • The cause of waterhammer phenomenon due to valve closing which is installed on pipeline is clarified in this study. Also if waterhammer phenomenon occurs on simple pipeline, expensive facilities like pressure relief valve is adapted to protect pipeline from waterhammer so far. But this study shows that waterhammer phenomenon can be suppressed by just simple modification of valve control sequence, and this technique is verified by simulation and site experiment.

Bingham Charateristics of Electrorheological Fluid and Its Application to ER valve and ER Damper (전기유변유체의 빙햄특성과 밸브 및 댐퍼에의 응용)

  • 배종인
    • The Korean Journal of Rheology
    • /
    • v.10 no.1
    • /
    • pp.31-37
    • /
    • 1998
  • 전기장이 인가되고 있는 유로를 유동하는 전기유변유체의 기본성질을 파악하기 위 한 실험 및 해석적 연구를 수행하여 빙햄유체로서의 유효성에 대해 알아보고 전기장과 유로 면 형상 및 진동유동으로 인한 영향에 대해 조사함으로써 ER밸브 및 ER대퍼로의 응용과 관련한 감쇄력 제어에 대해 검토하였다. 첫 번째 실험은 ER밸브의 높이가 2mm인 적극면이 평탄한것과 요철로 된 것을 사용하여 압력손실을 압력변환기로 측정함으로써 전기장 및 유 로형상에 대한 영향을 알아보았다. 압력손실 및 전단응력이 전기자세기와 함수관계를 가짐 을 알수 있었고 전기장세기와 유속의 변화시 손실계수에 의한 ER효과의 상이함이 확인되었 으며 레이놀즈수가 커지면 항복전단응력의 영향은 나타나지 않았다. 두 번째 실험은 실린더 를 정현파로 진동시켜 ER밸브에서 감쇠력제어가 가능한가를 알아보고 빙햄유체모델로 설계 된 ER댐퍼의 모델과 비교하였다. ER배르와 ER댐퍼의 수학적 모델을 시뮬레이션한 결과는 약간 벗어남이 보이기는 하나 실험결과와 일치하요 있다. 이것은 ER유체를 단순히 빙행유 체로 취급할수없으나 거시적으로는 빙햄유체로 취급할수 있음을 시사한다.

  • PDF

Effects of the Blockage Ratio of a Valve Disk on Loss Coefficient in a Butterfly Valve (밸브 디스크 차단비 변화가 버터플라이밸브의 손실계수에 미치는 영향에 관한 실험적 연구)

  • Rho, Byung-Joon;Choi, Hee-Joo;Lee, Jee-Keun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.1
    • /
    • pp.39-46
    • /
    • 2008
  • The loss coefficient of the butterfly valve which allows partial opening of the valve at closed position and is applicable to the small-sized pipe system with the diameter of 1 inch was measured for the variation of the valve disk blockage ratio. Two different types of the valve disk configuration to adjust the blockage ratio were considered. One was the solid type valve disk of which the diameter was changed into the smaller size rather than the pipe diameter, and the other was the perforate type valve disk on which some holes were perforated. The results from two types of valve disk were compared to identify their characteristics in the loss coefficient distributions. The loss coefficient and the controllable angle of the valve disk were decreased exponentially with the decrease of the blockage ratio. In addition, the perforate valve disk had the effect on the higher loss coefficient rather than the solid type valve disk.

Comparison of Loss Coefficient using 1-inch Ball and Glove Valve Opening Ratio (1인치 볼 밸브 및 글로브 밸브에 대한 개도율에 따른 손실계수(k) 비교에 관한 연구)

  • Kang, Chang-Won;Yi, Chung-Seob;Lee, Chi-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.9
    • /
    • pp.63-69
    • /
    • 2021
  • This study aims to determine the flow characteristics of a one-inch small ball valve and glove valve used in industrial plants. The flow was changed through an experimental equipment, and the internal flow characteristics of the valves were compared. Considering the pressure drop, the decrease in the slope of the ball valve based on the degree of the valve opening was relatively greater than that of the glove valve; further, the slope of the glove valve was gentle while the pressure drop was high. The flow velocity of the ball valve remains consistent after the valve was opened by 70%, whereas the flow velocity of the glove valve constantly increased. The valve loss factor of the ball valve was relatively low compared with that of the glove valve. When the valve was opened by 20%, which is the beginning stage of the valve opening, the valve loss factor of the ball valve was high and gradually became low. This is a structural problem of the ball valve, and the loss factor is significant because the flow path installed at the ball valve has a considerably small area. However, the overall loss factor of glove valve is high because it has a complicated structure of flow path.