• Title/Summary/Keyword: 배치효과

Search Result 1,415, Processing Time 0.027 seconds

RFID-Based Concrete Pour Monitoring System Implementation (RFID 기반의 콘크리트 타설 모니터링 시스템의 구현)

  • Moon, Sung-Woo;Hong, Seung-Moon
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2006.11a
    • /
    • pp.529-532
    • /
    • 2006
  • The application of ubiquitous technology offers many chances for improving construction management technologies. Currently the Construction System Integration Lab (CSIL) at Pusan National University is executing research on applying ubiquitous technology for better communication in the construction process. One of the research area is the implementation of RFID for monitoring the concrete pour process. The objective of this study is to collect data occurring in the process and use the data be properly planning concrete pour activities. Case study has been done on an actual concrete work. For the study a user environment was developed interfacing on internet with RFID devices that were installed in a batch plant and a construction site. The result of the test demonstrated that the RFID-based concrete monitoring can be a feasible approach for improving the communication in the construction process.

  • PDF

A Numerical Study of Cathode Block and Air Flow Rate Effect on PEMFC Performance (고분자전해질 연료전지의 환원극 블록과 공기 유량 영향에 대한 전산 해석 연구)

  • Jo, Seonghun;Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.33 no.1
    • /
    • pp.96-102
    • /
    • 2022
  • Reactants of PEMFC are hydrogen and oxygen in gas phases and fuel cell overpotential could be reduced when reactants are smoothly transported. Numerous studies to modify cathode flow field design have been conducted because oxygen mass transfer in high current density region is dominant voltage loss factor. Among those cathode flow field designs, a block in flow field is used to forced supply reactant gas to porous gas diffusion layer. In this study, the block was installed on a simple fuel cell model. Using computational fluid dynamics (CFD), effects of forced convection due to blocks on a polarization curve and local current density contour were studied when different air flow rates were supplied. The high current density could be achieved even with low air supply rate due to forced convection to a gas diffusion layer and also with multiple blocks in series compared to a single block due to an increase of forced convection effect.

A Study on Behavior Characteristics of Soft Ground by DCM Arrangement Type (DCM 배치 형상에 따른 연약지반 거동 특성에 관한 연구)

  • You, Seung-Kyong;Lee, Jong-Young;Hong, Gigwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.20 no.4
    • /
    • pp.125-131
    • /
    • 2021
  • This study described the relationship of settlement-lateral displacement and settlement-heaving according to the DCM type using the model test results, in order to evaluate the behavioral characteristics of the soft ground improved with DCM. As a result, it was found that the total settlement of the model ground was relatively small in the soft ground, to which the DCM was applied, and the settlement was less in the order of the grid type, wall type, and pile type under the same load conditions. This trend was also the same for the lateral displacement and heaving. In addition, the relationship between settlement and lateral displacement of soft ground was analyzed to be similar to that of previous study (Leroueil et al., 1990). Therefore, the DCM of grid type was evaluated to be superior to other types for lateral flow and heaving in the improvement effect of soft ground.

Analysis on the Behavior of Reticulated Root Piles for Reinforcing Footing using Computer Program (컴퓨터 프로그램을 이용한 기초보강용 그물식 뿌리말뚝의 거동 분석)

  • 박영호;변광욱
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1991.10a
    • /
    • pp.348-361
    • /
    • 1991
  • When reinforcing strip footing on a sand 8round with reticulated root piles, reinforcing effect depends on the length , number, cross sectional area, penetration angle, spacing, and Young's modulus of piles. the mode of action of reinfocement tendons in soil isn't one of carring developed tensile stresses but of anisotropic(uni-directional) reduction or even supression of one normal strain rate. R. H. Bassett and N. C. Last proposed that the reinforcement should be located on the direction of minor strain rate which coincides with the tensile strain rate in the velocity characteristics. Based on this proposal the author carried out a series of 2 - dimentional finite element analysis which varies the parameters mentioned above.

  • PDF

Analysis and Implications of Staffing Standards for Public Library in Korea and Foreign Countries (국내외 공공도서관 직원배치기준의 분석과 시사점)

  • Yoon, Hee-Yoon
    • Journal of Korean Library and Information Science Society
    • /
    • v.42 no.1
    • /
    • pp.73-95
    • /
    • 2011
  • The success or failure of the public library system depends upon the effective management of the human resources. It means that public library's staff is the most important resource in the operation and delivery of services. In order to provide the best service to the community, therefore, it is necessary to maintain excellent staff to make effective use of the information resources of the library and to meet the demands of the community. The goal of this study is to compare and analyse the staff standards and guidelines of public libraries in international organizations(IFLA/UNESCO, ISO), major developed countries(USA, UK, Canada, Australia, Taiwan, Japan), and Korea. In addition, the implications derived from this study will be used to provide a valuable theoretical background and rationale for the future research.

Nonparametric Method in One-way Layout for Umbrella Alternatives based on Placement (일원배치법에서 Umbrella Alternatives에 대한 위치를 이용한 비모수 검정법)

  • Lee, Hyejung;Kim, Dongjae
    • The Korean Journal of Applied Statistics
    • /
    • v.28 no.6
    • /
    • pp.1181-1189
    • /
    • 2015
  • The treatment effect in clinical tests depending on dose of the drug; however, it can show a decreasing trend in fixed dose level due to side effects. The trend is known as an umbrella pattern; in addition, the method for the umbrella alternative is quite useful when the tendency is predicted in advance. In this paper, we propose a nonparametric method of umbrella alternatives for a one-way layout by using linear placement described in Orban and Wolfe (1982). The Monte Carlo simulation is adapted to compare the power of proposed procedure with previous methods.

Effect of Cell Shape on Design of CDMA Systems for Urban Microcells (도심 MICROCELL의 CDMA 시스템 용량에 대한 기지국 배치 효과)

  • Min, Seung-Wook;Choi, Gin-Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.3B
    • /
    • pp.153-160
    • /
    • 2007
  • Placing antennas of low power base stations below surrounding buildings, as in urban microcells, makes propagation characteristics strongly dependent on the building environment. As a result, propagation in these urban microcells is non-isotropic, so that the assumption of circular cells used in planning of conventional cellular sys toms is no longer valid. Assuming circular cells leads to a more conservative system design, implying more base stations. This work investigates the effect of cell shape, due to non-isotropic propagation, on the out-of-cell interference and Erlang capacity of CDMA system. Propagation is described by measurement derived models for low antennas in a rectangular urban street grid. The analysis is done for soft handoff protocols.

Evaluation of Effect on CFS Location (CFS 입지에 따른 경제적 효과 평가)

  • Song, Yong-Seok;Nam, Ki-Chan;Kwak, Kyu-Seok
    • Journal of Navigation and Port Research
    • /
    • v.28 no.1
    • /
    • pp.69-74
    • /
    • 2004
  • Container Freight Station(CFS), which would be located inside terminal or outside, plays the role of consolidating less than container load(LCL) cargo gathered from multi shippers and deconsolidating full container load cargo into individual consignment. When CFS is allocated inside terminal it muses several problem such as traffic gam around terminal, high social and logistics cost and deterioration of terminal condition. This study, therefore, tries to evaluate the location of CFS, inside and outside of terminal, with respect to the social and logistics costs.

A Study on Riprap Size in Meandering Channels by Hydraulic Model Test (수리모형 실험에 의한 사행하도의 사석 크기에 관한 연구)

  • 문수남
    • Water for future
    • /
    • v.28 no.4
    • /
    • pp.205-213
    • /
    • 1995
  • Flow in meandering channel is a great concern to civil engineers and may further be characterized as one of the key problems in river morphology. It is difficult to state generalized criteria for channel improvement applicable to any particular river. But it is important to provide some principles and quidelines for the design engineer. The objective of this experimental study is to suggest riprap size, principles and quidelines for the design engineer by the hydraulic model test. For the sake of effective uses for the bank stabilization, hydraulic model tests about riprap weight and size are performed and examing thoroughly. Riprap weight for the upstream of the curvature appex can be computed by U.S.B.R. and Brahms' equation, and the size by Mavis and Laushey's equation. Those for the downstream can be computed using Brahms' and Steinberg's equations, respectively.

  • PDF

System-Level Simulation for Efficient Displacement of Base Station Antennas for CDMA Uplink System in Urban Microcells (도심 마이크로셀에서 CDMA 시스템을 위한 효율적인 기지국 배치를 위한 모의실험)

  • Min, Seung-Wook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.5A
    • /
    • pp.517-525
    • /
    • 2008
  • In this paper, we cary out system level simulations to investigate the effect of cell shape(i.e., different base station displacements in the two directions defined by the street grid) on minimizing transmitter power, interference power, and blocking probability for CDMA system in urban microcellular environments. In urban microcell, path loss to the base station depends on the orientation of the street where the mobile is located. Interference from mobile stations to the base station in the reference cell is considered up to second tier. The wrap around method is used to include the second tier interference with realistic computational complexity without reducing the accuracy of interference calculations. The investigation shows that the transmitter power, interference power, and blocking probability in a cell can be reduced by proper selection of the efficient cell shape.