• Title/Summary/Keyword: 배출농도

Search Result 1,447, Processing Time 0.034 seconds

Characterization on Air Pollution of Gunpo City by Measurement of VOCs in Air (대기중 휘발성 유기화합물 측정을 통한 군포시 대기 오염 특성 규명)

  • Park, Hyun-Mee;Kim, Jee-Hyuon;Park, Il-Yong;Kim, Young-Man;Lee, Kang-Bong
    • Analytical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.556-566
    • /
    • 2002
  • Gunpo city, a medium sized city formed with a basin is populated with a little more than 270,000 peoples and includes the industrial area with about 600 factories. It has been recognized for a long time that peoples living nearby industrial area have complained on serious air contamination due to the geographical and environmental factors. This study was performed on measurement of volatile organic compounds (VOCs) and malodor for the air sampled in various places of Gunpo city, and made comparison with VOCs levels in specific area of Seoul. This work would play important role for the efficient management of air contamination of Gunpo city. Samplings were done in the rooftop of eleven village office buildings including Gunpo station in June 12th, 2001. Analytical results indicate that VOCs levels of Gunpo-1-dong, Gunpo station and Kumjungdong regions neighboring industrial area were much higher than the rest of areas, and this fact shows that the origin for air contamination of Gunpo would be industrial area than car exhaustion gases.

Operation of CROM System and its Effects of on the Removal of Seston in a Eutrophic Reservoir Using a Native Freshwater Bivalve (Anodonta woodiana) in Korea. (담수산 이매패 펄조개를 이용한 흐름형 유기물 제어(CROM) 운영 - 퇴적물의 영향)

  • Kim, Baik-Ho;Baik, Soon-Ki;Hwang, Su-Ok;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.2
    • /
    • pp.161-171
    • /
    • 2009
  • A 'continuous removal of organic matters (CROM) system' using a native freshwater bivalve in Korea Anodonta woordiana, was developed to determine its potential of controlling various sestons in eutrophic lake system, and to evaluate its effect on water quality improvement under consideration of sediment addition as habitat. We designed CROM experiments with four treatments: no mussels and no sediment (W, negative control), no mussels and sediment (WS, positive control), mussels and no sediment (WM), and mussels and sediment (WMS). The experiments were performed at the condition of 18${\sim}$25 L $h^{-1}$ of inflow, mussel density of 486.1 indiv. $m^{-2}$, and temperatures between 15 and $22^{\circ}C$ for 13 consecutive days. Physicochemical and biological parameters were measured at daily (10:00 am) intervals after the mussel addition. Results indicated that mussel stockings without addition of sediment effectively removed sestons (suspended solids and chlorophyll-a) at nearly same level over 80 percentage of the control during the study, while there were no differences in removal activities of sestons between with and without sediment (P>0.5). Therefore, it clearly suggests that CROM system using A. woordiana has a strong potential to control the seston in surface water of eutrophic lake.

Effects of Ozone Treatment to Pig Liquid Manure on Reduction of Odorous Gases (돈분뇨 액비의 악취저감을 위한 오존처리 효과)

  • Jeong, J.W.;Yoo, Y.H.;Park, K.H.;Kam, D.H.;Choi, H.J.;Kim, T.I.;Cho, Y.S.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.3
    • /
    • pp.161-170
    • /
    • 2007
  • Ozone from a pilot-scale ozone generator was treated on fermented pig liquid manure stored in a storage tank in order to reduce odor substances during the process of fermented liquid manure production. The group of ozone treatment showed one less than the organic matter compared that of the control. The preferable condition for characteristic changes was when the ratio of BOD to COD was less than 1.5. Ozone treatment showed better oxidizing power than control as it removed more suspended solids and had less methyl isobutyl ketone(P<0.05). Odor reduction measured by olfactory method was higher in ozone treatment than in control.

  • PDF

Angiotensin Converting Enzyme Inhibitory Activity in Peptic Hydrolysates of Cooking Discards from Anchovy Factory Ship (멸치 가공선 자숙폐액 Pepsin 가수분해물의 Angiotensin 전환효소 저해작용)

  • Ji, Cheong-Il;Lee, Ji-Hye;Park, Douck-Choun;Gu, Yeun-Suk;Kim, In-Soo;Lee, Tae-Gee;Jung, Kyoo-Jin;Park, Yeung-Ho;Kim, Seon-Bong
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.3
    • /
    • pp.529-532
    • /
    • 2002
  • The angiotensin converting enzyme (ACE) inhibitory activity in peptic hydrolysate of raw anchovy cooking discards was 51.3% at 1 mg of protein per $100\;{\mu}L$ sample solution. While, after the treatment of pepsin for 4 h, was 65.8%. The crude peptides fractionated through Bio-gel P-2 column chromatography consisted of five fractions $({P-1}{\sim}{P-5})$ and had maximum inhibitory activity in the fraction P-2 ($IC_{50}$=0.319 mg protein/mL). The fraction P-2 was rich in aspartic acid, glutamic acid, and glycine.

Generation Characteristics and Prediction of Acid Rock Drainage(ARD) of Cut Slopes (건설현장 절취사면의 산성암반배수 발생특성과 잠재적 산발생능력 평가)

  • Lee, Gyoo-Ho;Kim, Jae-Gon;Lee, Jin-Soo;Chon, Chul-Min;Park, Sam-Gyu;Kim, Tack-Hyun;Ko, Kyung-Seok;Kim, Tong-Kwon
    • Economic and Environmental Geology
    • /
    • v.38 no.1
    • /
    • pp.91-99
    • /
    • 2005
  • Acid Rock Drainage(ARD) is the product formed by the atmospheric(i.e. by water, oxygen and carbon dioxide) oxidation of the relatively common iron-sulphur mineral pyrite($FeS_2$). ARD causes the acidification and heavy metal contamination of water and soil and the reduction of slope stability. In this paper the generation characteristics and the prediction of ARD of various cut slopes were studied. An attempt to classify the rocks into several groups according to their acid generation potentials was made. Acid Base Accounting(ABA) tests, commonly used as a screening tool in ARD predictions, were performed. Fourteen rock samples were classified into PAF(potentially acid forming) group and four rock samples into NAF(non-acid forming) group. The chemical analysis of water samples strongly suggested that ARD with high content of heavy metals and low pH could pollute the ground water and/or stream water.

A study on the dye wastewater treatment by Fenton oxidation process (Fenton 산화공법을 적용한 염색폐수처리 연구)

  • Ahn, June-Shu;Park, Tae-Sool;Cho, Jung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.9
    • /
    • pp.4274-4282
    • /
    • 2011
  • In this study, Fenton reaction was studied for the possibility of applying as advanced treatment and its optimal condition for the removal of refractory organics from the dye wastewater. Fenton reaction was applied to remove refractory organics after the bio-treatment (secondary treatment) inside test laboratory and on-site pilot plant. Wastewater from the secondary treatment was used and its $COD_{Mn}$ was measured as 30~50mg/L. After the Fenton reaction, the optimal condition was found as pH 3~3.5, reaction time 2~2.5hr, chemical input ratio of ($FeCl_2$(33%)/$H_2O_2$(35%)) was 3 : 1. When chemical input ratio of ($FeCl_2$(33%)/$H_2O_2$(35%)) was at its optimal, amount of sludge volume ($SV_{2hr}$) was 21~28%. With pilot plant test, removal rate was heavily influenced by the hydraulic retention time(HRT), and optimum value of HRT was 2.0 hr. When pilot plant($2m^3/d$) was placed on-site and operated continuously, it showed steady and fairly good treatment of COD where COD removal rate was 60~70%, treated water showed below 20mg/L.

Study of continuous regeneration of carbon dioxide sorbent using amino acid salt (아미노산염을 이용한 이산화탄소 흡수제 연속 재생에 관한 연구)

  • Choi, Jin-Sik;Kim, Jae Gang;Lee, Jun Hyung;Chu, Yeon Jin;Lee, Ju-Yeol;Park, Byung Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.947-953
    • /
    • 2017
  • In this study, the regeneration efficiency of the amino acid salt absorbent which can be applied to carbon dioxide absorption / regeneration process was confirmed. The regeneration efficiency has a great influence on the economical judgment of the process. so, continuous regeneration experiment was conducted to establish economical process. The amino acid salts used in the experiments are Potassium L-lysinate and Potassium L-alaninate. Each amino acid and potassium hydroxide(KOH) were mixed at a 1: 2 molar ratio. In order to confirm the regeneration efficiency of the absorbent, carbon dioxide was absorbed in the two materials, and the carbon dioxide desorption experiment was carried out by heating. The initial reaction rate was L-alanine was faster. Over time, L-lysine, desorption higher concentrations of carbon dioxide. L-lysine showed higher regeneration efficiency than L-alanine, (L-alanine 47.26% and L-lysine 62.11%). As a result of the continuous regeneration experiment using the L-lysine having good absorption and regeneration efficiency, it was confirmed that the regeneration efficiency decreases as the number of regeneration increases.

Experimental Study on Reduction of Particulate Matter and Sulfur Dioxide Using Wet Electrostatic Precipitator (습식전기집진기를 활용한 입자상 물질 및 황산화물 저감 성능에 관한 실험적 연구)

  • Kim, Jong-Lib;Oh, Won-Chul;Lee, Won-Ju;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.6
    • /
    • pp.898-904
    • /
    • 2021
  • This experimental study aims to investigate the use of a wet electrostatic precipitator as a post-treatment device to satisfy the strict emission regulations for sulfur oxides and particulate matter (PM). The inlet/outlet of a wet electrostatic precipitator was installed in a funnel using a marine four-stroke diesel engine (STX-MAN B&W) consuming marine heavy fuel oil (HFO) with a sulfur content of about 2.1%. Measurements were then obtained at the outlet of the wet electrostatic precipitator; an optical measuring instrument (OPA-102), and the weight concentration measurement method (Method 5 Isokinetic Train) were used for the PM measurements and the Fourier transform infrared (FT-IR; DX-4000) approach was used for the sulfur oxide measurements. The experimenst were conducted by varying the engine load from 50%, to 75% and 100%; it was noted that the PM reduction efficiency was a high at about 94 to 98% under all load conditions. Additionally, during the process of lowering the exhaust gas temperature in the quenching zone of the wet electrostatic precipitator, the sulfur dioxide (SO2) values reduced because of the cleaning water, and the reduction rate was confirmed to be 55% to 81% depending on the engine load.

A study on the improvement of hydrophilic properties of activated carbon surface by nitric acid treatment (질산 처리에 따른 활성탄 표면의 친수성 특성 향상에 관한 연구)

  • Kang, Hye Ju;Yang, So Yeong;Kim, Tae Min;Kim, Yong Ryeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.5
    • /
    • pp.1241-1248
    • /
    • 2021
  • In order to figure out various environmental problems, various governments and companies are investigating more environmentally policies and technologies. In other words, activated carbon is widely used for the adsorption of different harmful gases and waste liquid treatment. However since the required surface properties are different in various industry, depending on the adsorption properties, the development of activated carbon demand in different ways. In this work, we have investigated and developed the activated carbon surface to improve the hydrophilic properties by nitric acid treatment through reforming of activated carbon.

Effect of SUS316L Bipolar Plate Corrosion on Contact Resistance and PEMFC Performance (SUS316L 분리판 부식에 의한 접촉저항 및 고분자전해질 연료전지 성능에 미치는 영향)

  • Kim, Junseob;Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.32 no.6
    • /
    • pp.664-670
    • /
    • 2021
  • Stainless steel was applied as bipolar plate (BP) of polymer electrolyte membrane fuel cell (PEMFC) due to high mechanical strength, electrical conductivity, and good machinability. However, stainless steel was corroded and increased contact resistance resulting PEMFC performance decrease. Although the corrosion resistance could be improved by surface treatment such as noble metal coating, there is a disadvantage of cost increase. The stainless steel corrosion behavior and passive layer influence on PEMFC performance should be studied to improve durability and economics of metal bipolar plate. In this study, SUS316L bipolar plate of 25 cm2 active area was manufactured, and experiments were conducted for corrosion behavior at an anode and cathode. The influence of SUS316L BP corrosion on fuel cell performance was measured using the polarization curve, impedance, and contact resistance. The metal ion concentration in drained water was analyzed during fuel cell operation with SUS316L BP. It was confirmed that the corrosion occurs more severely at the anode than at the cathode for SUS316L BP. The contact resistance was increased due to the passivation of SUS316L during fuel cell operation, and metal ions continuously dissolved even after the passive layer formation.