• 제목/요약/키워드: 배전 선로

검색결과 671건 처리시간 0.045초

외부 배전선 사고에 대한 분산전원 보호 알고리즘의 동작 수준 평가 (Assessment of the Protection Algorithm Applied in Distributed Generations for Faults Occurred in the Interconnected Distribution Networks)

  • 장성일;김세근;박용업;김광호;최정환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.337-340
    • /
    • 2003
  • This paper describes the operational characteristics of protection algorithm applied in distributed generations(DG) for faults occurred in the interconnected distribution networks. The DG can be Influenced by abnormal grid conditions such as disturbances occurring in the neighboring distribution feeders as well as the interconnected power line. Particularly, in case of the fault happening in the neighboring distribution feeders emanated from the substation to which DG is connected, the protective devices in the DG might mis-operate. The mis-operation of protective devices can be varied by the fault conditions. The simulation results for Hoenggye substation model composed of five feeders using PSCAD/EMTDC showed that the number of mis-operation of protective devices applied in DG is about 0.66 times per one year.

  • PDF

배전선로 고장징후 검출 파라메타 선정을 위한 데이터 취득 시스템의 개발과 시간변수의 적용기법 (Development of Data Acquisition System and Application of Time-Domain Parameters for detecting Fault Symptoms on Distribution Feeders)

  • 신정훈;전명열;유명호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.152-156
    • /
    • 1996
  • Identification of incipient faults and various events on the distribution feeders is very important to develop the prediction method of fault symptom. In this paper, the configuration of data acquisition system to get the real field data is introduced. And the Quantification of incipient faults is also discussed. Based on the acquired field data, how the time domain parameters of voltage and current signals are applied to this research is partly introduced.

  • PDF

적정 배전계통 구성을 위한 선로분할 효과 분석 (Analysis of Distribution Line Sectionalizing Effects for The Probable Distribution System Configuration)

  • 김재환;하복남;남기영;이주광
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.86-89
    • /
    • 1993
  • This paper contains the various effect of distribution feeder sectionalizing by distribution automation. The effect by automatic sectionalizing switch and the effect by manual switch are analyzed and shown according to the radial feeder and the loop feeder respectively. Based on the reliability analysis, the reference for the feeder division and sectionalization is recommended. Also, the necessary number of manual switch where the automatic switch is installed is recommended through the reliability analysis.

  • PDF

배전선 자동운전을 위한 MMI System 개발사례 (Development of Man Machine I/F for Distributed Power Line Automation)

  • 이재덕;김국헌;김광령;옥기정
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.427-429
    • /
    • 1993
  • In this paper, GIS (Geographical Information System) for KODAS (Korea Distribution Automation System) will be presented. It has been developed to display the status of distribution power line facilities with background geographical map information (eg. address, street, railways and building) and provides various menu screen that can be handled easily. We will discuss computer system I/F between Host computer and GIS, DB structure for GIS and It's functions.

  • PDF

지중배전선로 서지해석의 실증적 연구 (A Study on the Field Test for Surge Analysis in Underground Distribution Systems)

  • 윤창섭;이종범;이재봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.701-702
    • /
    • 2007
  • This paper describes the modelling techniques for surge analysis in underground distribution systems with power cables. To evaluate the Analysis model, the change of line model and permittivity is considered. power cable parameters calculated by LCC of EMTP are considered to evaluate surge model in underground distribution systems. It is evaluated that impulse model according to the shape of impulse source model. However it is confirmed through comparison with measurement value in field test of underground distribution systems.

  • PDF

신재생 에너지 전원을 고려한 배전선로 고장구간 판단 기법 (Faulted Section Identification Method in The Distribution Systems with Renewable Energy Resources)

  • 이한성;전철우;김영국;임성일
    • 전기학회논문지
    • /
    • 제63권10호
    • /
    • pp.1321-1327
    • /
    • 2014
  • Faulted section identification is one of the most important function in distribution automation systems. Conventional over current detection based fault indicators frequently mal-operate due to the reverse fault current from the renewable energy resources. This paper present a new faulted section identification method based on the fuzzy decision making technique. In order to establish feasibility of the proposed method, case studies using Matlab Simulink has been performed.

초전도 한류기를 주변압기 접지선에 설치시 배전계통의 순간전압품질 분석 (Voltage Quality Analysis in Power Distribution System with Superconducting Fault Current Limiter at Grounding Line)

  • 문종필
    • 전기학회논문지P
    • /
    • 제62권4호
    • /
    • pp.159-163
    • /
    • 2013
  • In this paper, voltage quality improvement is analyzed in case of Superconducting Fault Current Limiter (SFCL) installed in grounding line of main transformer in power distribution system. First, a resistive-type SFCL model is used. Next, Korean power distribution system is modeled. Finally, when SFCL is installed in the starting point of feeder and grounding line of main transformer, voltage qualities are evaluated according to various fault locations and resistance values of SFCL using PSCAD/EMTDC. The voltage quality results in case of grounding line are compared with the voltage in case of feeder.

혼합 배전선로에 직격낙뢰시 전주와 케이블직선접속재가 케이블 동심중성선 전위상승에 미치는 영향 (A Study of Concentric-Neutral Line Voltage Increase Related by Pole and Cable Joint When Lightening Overvoltage Injected in Combined Distribution Line)

  • 전용주;전명수
    • 전기학회논문지
    • /
    • 제67권6호
    • /
    • pp.702-707
    • /
    • 2018
  • In case of Lighting occurs in Domestic combined distribution line, normally the voltage for the neutral line increase dramatically. General connection for underground cable is bundled common earth type so the lightning over voltage increase at the concentric-neutral line is not big enough to give impact on cable sheath. But in case of Non bundled common earth type it is necessary to analyze the phenomena on cable sheath caused by lightening overvoltage. Especially pole and cable joint are the core factor to consider. In this paper concrete pole and cable joint were evaluated in case of Non bundled common earth type combined distribution Line. EMTP simulation model has been designed and several case study were made. Also several experimental test were made to verify the simulation result.

전력선 통신을 위한 저압 배전 시스템의 임피던스 연구 (Study on Characteristic Impedance in LV Distribution System for PLC)

  • 김용성;김재철;이양진;조성민
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.78-81
    • /
    • 2006
  • In this paper, the investigation of characteristic impedance on low voltage distribution system is described The residential area of LV distribution systems is researched for the modeling. At frequency range from 1MHz to 30Mhz, the input characteristic impedances of low-voltage distribution network are obtained with experiments. The low-voltage distribution system based on the model is built at the laboratory building. S parameters are measured by performing experiments. Finally, the characteristic impedances are reported.

  • PDF

최소신장트리를 이용한 배전선로 다중 과부하 해소 방법 (Load Balancing Technique to Release Multiple Overloading of Distribution Feeders using Minimum Spanning Tree)

  • 오성현;이한성;김영국;임성일
    • 조명전기설비학회논문지
    • /
    • 제29권2호
    • /
    • pp.33-39
    • /
    • 2015
  • Power supplying capacity of the distribution feeder should be maintained within thermal capacity of the wire. This paper presents the minimum spanning tree based load balancing technique to release multiple overloading of distribution feeders. In order to minimize number of involved backup feeders, Dijkstra and Prim algorithm are adopted to construct minimum spanning tree. Simulation testing result based on part of KEPCO's commercial distribution systems shows effectiveness of proposed scheme.