• 제목/요약/키워드: 배전 선로

검색결과 671건 처리시간 0.028초

EMTP 시뮬레이션을 통한 배전선로의 1선 지락 사고시 화재 조사 기법에 관한 연구 (A Study on Fire Investigation Technique For Single Line to Ground Faults in Distribution Line Using EMTP Simulation)

  • 유정현;김희식;이훈기;조용선
    • 한국안전학회지
    • /
    • 제33권3호
    • /
    • pp.21-26
    • /
    • 2018
  • Approximately 20% of the total fire is electrical fire, and electrical energy is a potential source of heat. Large-scale fault currents that occur during a line ground fault flow into electric utility poles, electric power equipment, or electric appliances of the customer, and cause simultaneous electrical fire. In this paper, we investigated the possibility of fire through the change of fault current flowing in faulty and sound feeder in case of 1 line ground fault in 22.9 kV distribution line. We propose a fire investigation analysis method for simultaneous multiple electrical fire such as evidence analysis method, and fault current occurrence confirmation method in case of fire accident by analyzing the fault current occurring in the ground fault in the distribution line using EMTP, electric power system analysis program.

高調波 中性電流를 低減시키기 위한 3相4線 竝列形 能動필터에 關한 硏究 (A Novel Three-Phase Four-Wire Shunt Active Filter to Eliminate Neutral Current)

  • 고경수;김래기;유권종;송진수;김시경
    • 전력전자학회논문지
    • /
    • 제3권3호
    • /
    • pp.184-190
    • /
    • 1998
  • 대부분의 빌딩과 공장에서는 3상 4선식 저압 배전 시스템으로 전력을 공급받고 있다. 이 방식은 중성선에 전류가 흐르게 하는데 오늘날 전력 변환 기술의 개발과 컴퓨터의 보급으로 심각한 중성 전류가 발생하고 있다. 본 논문은 병렬형 3상 4선 능동 필터를 사용하여 계통의 전원 전압이 불평형이고 불평형 부하 및 비선형 부하가 접속된 상태에서 전원쪽으로 흐르는 중성 전류를 제거시키고, 전원전류의 파형을 정현파로 개선하는데 목적이 있으며, 부하 조건을 변화시키면서 시뮬레이션을 실행하여 능동 필터의 우수한 성능을 입증하였다.

  • PDF

국내 강모래의 다짐특성 분석 (The Compaction Characteristics Analysis of Domestic River Sands)

  • 황성춘;오병현
    • 한국도로학회논문집
    • /
    • 제7권4호
    • /
    • pp.31-39
    • /
    • 2005
  • 본 연구는 지중배전관로 시공시 되메움재로 많이 사용되는 대표적인 국내 강모래의 다짐특성을 규명하고자 한국공업규격(KS 규격)에 따른 기본 물성시험 및 다짐시험을 실시하였다. 시험결과 비중은 2.63$\sim$2.67 범위에 해당되어 입도분포는 빈입도의 영역에 속함을 알 수 있었다. 또한, 다짐시험결과 최대 건조단위중량은 $1.70. 최적함수비는 11.30$\sim$13.80%의 범위로 나타났다. 다짐에너지에 따른 다짐도의 변화경향은 일련의 쌍곡선 함수식으로 잘 근사되는 것을 알았으며, 이와 같이 구해진 다짐도로 우리나라의 대표적인 강모래의 다짐특성을 규명하는 것이 가능했다.

  • PDF

고압배전선로용 선로전압조정장치(SVR)의 최적 도입방안에 관한 연구 (A Study on the Optimal Introduction of Step Voltage Regulator(SVR) in Distribution Feeders)

  • 이은미;김미영;노대석;손상욱;김재언;박창호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권11호
    • /
    • pp.610-618
    • /
    • 2004
  • With the development of industry and the improvement of living standards, better quality in power electric service is required more than ever before. Under these circumstances, to deliver reasonable voltage regulation methods in distribution systems need to be developed. So, This paper deals with optimal introduction of the line voltage regulator (SVR : Step Voltage Regulator) in power distribution systems. First, This paper investigates characteristics of SVR and performs economic evaluation of SVR's introduction by using Present Worth Method. This paper, also suggests proper location and optimal voltage regulation algorithm. In order to deliver suitable voltages to as many customers as possible, the optimal sending voltage of SVR should be decided by the effective operation of voltage regulators at the distribution feeders. The simulation results using a model distribution system and real distribution systems show that the proposed methods can be a practical tool for the voltage regulation in distribution systems.

영구자석형 동기기에 의한 가변속 풍력발전 시스템의 PSCAD/EMTDC 시뮬레이션 모델 개발 (PSCAD/EMTDC Simulation Model of Variable Speed Wind Power Generation System Using Permanent Magnet Synchronous Machine)

  • 김정재;송승호
    • 전력전자학회논문지
    • /
    • 제10권6호
    • /
    • pp.610-617
    • /
    • 2005
  • 가변속 풍력발전 시스템의 시뮬레이션 모델을 PSCAD/EMTDC 기반으로 개발하였다. 개발된 시뮬레이션 모델은 바람 모델, 회전자 다이나믹스, 동기 발전기, 전력 변환기, 변압기, 배전 선로, 무한 모선 등으로 구성되어 있다. 특히 블레이드의 공기역학적 특성과 전력 변환기의 제어 전략도 포함되어 실질적인 풍력발전기의 동작 특성을 시뮬레이션 할 수 있다. 개발된 시뮬레이션 모델을 이용하여 입력 풍속의 변동, 발전기 주변 부하의 변동, 계통측 전원 전압의 불평형 등의 다양한 조건에서 풍력발전기의 과도 상태 거동 특성을 확인하였다. 본 연구 결과는 앞으로 가변속 풍력발전기와 전력계통의 연계 운전시 신뢰성을 높이고 전력 시스템을 보호하기 위한 기초자료로서 활용될 수 있을 것으로 기대된다.

송배전 선로 고장력 인장시험기 개발 (Development of High Tension Tensile Tester for Transmission Line)

  • 신동화;이병호
    • 한국산업융합학회 논문집
    • /
    • 제21권5호
    • /
    • pp.219-225
    • /
    • 2018
  • In this paper, for the testing of tensile strength of dead-end clamp used in transmission line, resulting values were estimated by designing and producing the horizontal version of widely-used vertical tensile tester. Tensile strength test of dead-end clamp for transmission line is essential for quality test of products. Moreover, tensile tester is an equipment that requires high level of reliability which needs to be examined through sampling tests commensurate with total inspection. Frames of tensile tester were made up of H-beams so that it can endure more than 20 [tons] of load capability and the test was implemented for 60[seconds] applying five types of tension. In consequence, the tester could withstand up to 21,600[kg] of weight as well as all types of tension. This newly developed horizontal tensile tester can be utilized in figuring out properties of various materials by estimating tensile strength of materials such as metal, rubber and fiber.

배전 선로 부하예측 모델의 신뢰성 평가를 위한 비교 검증 시스템 (Development of Comparative Verification System for Reliability Evaluation of Distribution Line Load Prediction Model)

  • Lee, Haesung;Lee, Byung-Sung;Moon, Sang-Keun;Kim, Junhyuk;Lee, Hyeseon
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제7권1호
    • /
    • pp.115-123
    • /
    • 2021
  • Through machine learning-based load prediction, it is possible to prevent excessive power generation or unnecessary economic investment by estimating the appropriate amount of facility investment in consideration of the load that will increase in the future or providing basic data for policy establishment to distribute the maximum load. However, in order to secure the reliability of the developed load prediction model in the field, the performance comparison verification between the distribution line load prediction models must be preceded, but a comparative performance verification system between the distribution line load prediction models has not yet been established. As a result, it is not possible to accurately determine the performance excellence of the load prediction model because it is not possible to easily determine the likelihood between the load prediction models. In this paper, we developed a reliability verification system for load prediction models including a method of comparing and verifying the performance reliability between machine learning-based load prediction models that were not previously considered, verification process, and verification result visualization methods. Through the developed load prediction model reliability verification system, the objectivity of the load prediction model performance verification can be improved, and the field application utilization of an excellent load prediction model can be increased.

전력배전 시스템에서의 취약 선로 분류를 위한 출현 패턴 마이닝 (Emerging Patterns Mining for Classifying Non-Safe Electrical Sections in Power Distribution System)

  • ;;이헌규;신진호;류근호
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2008년도 추계학술발표대회
    • /
    • pp.325-327
    • /
    • 2008
  • In electrical industry, classification methodology has been an important issue for analyzing power consumption patterns. It has many applications including decisions on energy purchasing, load switching as well as helping in infrastructure development. Our aim in this work is to classify the electrical section and find potentially non-safe electrical sections. For this purpose, we use Emerging Patterns based classification. The classification method uses the aggregate score of emerging patterns to build classifier. The proposed methodology was applied to a set of electrical section data of the Korea power. The test data and relational electricity information and knowledge are supported by Korea Electric Power Research Institute (KEPRI).

3상 4선식 배전계통에서 단상 능동필터를 이용한 중성선 전류의 보상 (Neutral Current Compensation Using Single Phase Active Power Filter in Three-Phase Four-Wire Electric Distribution Systems)

  • 최시영;김병섭;송종환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1046-1048
    • /
    • 2002
  • The increase of triplen harmonics in three-phase four-wire systems leads to overloaded neutral conductor, common-mode noise problems, derating of transformers, and so on. Various compensator has been designed to prevent the problems associated with the triplen harmonics. But these can not protect distribution system effectively because the triplen harmonic source is distributed extensively and distribution system type is diverse. This paper explain the operation and installation of single phase active power filter to eliminate triplen harmonics and then it is verified by simulation.

  • PDF

풍력발전이 연계된 배전선로 전압 및 과도상태 해석 (Voltage and Transient State Analysis of Distribution Line connected to Wind Power Generation)

  • 김세호;나경윤;김건훈
    • 한국태양에너지학회 논문집
    • /
    • 제26권2호
    • /
    • pp.61-67
    • /
    • 2006
  • The use of the wind energy resource is a rapidly growing area world-wide. The number of installed units is continuously increasing, and therefore, it is important to respect and to deal with the impact of wind power generation system. From the view of an electric grid utility, there is a major problem with the impact of the wind system on the voltage of the electric grid, to which a turbine is connected. In this paper, it is investigated the voltage impact and transient state analysis on distribution line, with which wind power generation system is connected. Connections of wind power system usually occur to voltage drop due to reactive power absorption and sometime result in higher than nominal voltage.