• 제목/요약/키워드: 배전 선로

검색결과 671건 처리시간 0.028초

고압배전선로의 선로전압조정장치(SVR)의 최적운용에 관한 연구(3) (A study on the Optimal Operation of Step Voltage Regulator(SVR) in the Distribution Feeders(3))

  • 이은미;노대석;박창호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.97-99
    • /
    • 2003
  • This paper deals with optimal voltage regulation methods of line voltage regulator(SVR : Step Voltage Regulator) in power distribution systems. In order to deliver suitable voltages to as many customers as possible, the optimal sending voltage of SVR should be decided by the effective operation of voltage regulators at the distribution feeders and substations. In this paper, a new voltage regulation method based on the existing method is presented and an optimal coordination method of multiple voltage regulators is extended. The results from a case study show that the proposed methods can be a practical tool for the voltage regulation in distribution systems.

  • PDF

인체모델 이용한 고전압 감전사고 모의 (Simulation of a High Voltage Electric Shock Accident using a Human body Model)

  • 장태준;정연하;송길목;노영수;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2238-2240
    • /
    • 2005
  • 고전압 감전은 순간적인 사고로서 접촉사고와 비접촉 사고로 나뉘어 진다. 이러한 사고를 모의하기 위하여 고전압 임펄스 발생장치를 이용하여 접촉과 비접촉시의 사고를 모의하고자 한다. 본 논문에서는 우리나라의 배전선로인 3상 4선의 수전설비의 감전위험성을 조사 한 후 인체모델을 가지고 직접 및 간접적으로 가해지는 전압, 전류를 실험을 통해 측정하고자 한다.

  • PDF

배전선로 선로전압을 이용한 과부하 사고 예방장치 개발에 관한 연구 (A Study on Development of Over-load Fault Prevention Apparatus using Distribution Line Voltage)

  • 곽동걸;박동훈;박영직;정도영;김동균
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.617-618
    • /
    • 2012
  • Recently as the inactive response characteristics of the existing RCD(Residual Current protective Device) used on low voltage power distribution system, so control of overload and electric short circuit faults, major causes of electrical fires, are not enough. Therefore, this paper is proposed a prevention apparatus using neutral line voltage and semiconductor switching devices for the prevention of electrical disasters in low voltage power distribution system caused by overload or electric short circuit faults. The proposed prevention apparatus confirms the excellent characteristics in response velocity and accuracy in comparison with the conventional circuit breaker(RCD) through various operation performance analysis.

  • PDF

분압용 적층형 소자를 이용한 고전압 계측에 관한 연구 (A Study on the High Voltage Measurement using Stack element for Voltage Division)

  • 윤광희;이용우;류주현;박창엽;하복남
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.319-322
    • /
    • 1999
  • In order to accurately measure the high voltage of 22.9[kV] power distribution lines, we investigated the temperature dependence of measuring voltage for single element and stack elements(22, 44, 66 layers, respectively). When one line voltage is 13, 20O[V], the error of measuring voltage with temperature(-25[$^{\circ}C$]~50[$^{\circ}C$]) was decreased with increasing of stack number and stack element with 66 layers was the least error of ${\pm}0.87%$.

  • PDF

트래킹억제형 알루미늄피복강심 알루미늄 절연전선 평가기술 (Assessment of Tracking Retardant Aluminium Stranded Conductor Aluminium Cald Steel Reinforced Outdoor Cable (ACSR/AW-TR/OC))

  • 소진중;심대섭;김규섭;윤기택
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.227-228
    • /
    • 2005
  • 사용중인 OC의 사고가 외물접촉, 자연현상, 일반인 과실 등으로 인하여 전체 배전선로 일시고장의 대부분을 차지하고 있음으로, 피복의 트래킹 성능을 개선하여 수목 및 조류와의 접촉으로 인한 접촉부 전개 집중 시 또는 지지금구의 바인더부에 고전계 인가 시 트래킹에 의한 절연물의 탄화, 침식 등에 의하여 발생할 수 있는 절연파괴 등의 사고 위험을 줄이기 위하여 개발된 제품으로 산악지역 등에서 내트래킹, 내부식성, 수밀성 및 전기적인 특성이 우수하다. 본 평가기술에서는 알루미늄 묘|복강선, 연선 및 절연체의 일반적인 특성과 트래킹성, 도체수밀, 내후성, 밀착도, 교류파괴전압 등의 주요한 평가시험에 대한 방법을 검토하여 평가시험에 적용하여 평가시험시 문제점을 도출하고 평가시험방법을 정립하고자 한다.

  • PDF

분산전원이 연계된 배전 계통의 고장 선로 구분 (Identification of the faulted Feeder it Distribution Networks with Distributed Generations)

  • 김세근;김광호;장성일;강용철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.257-259
    • /
    • 2004
  • This paper proposes the identification method for the faulted feeder, where it identify whether the faulted feeder is the DG-connected feeder or the neighboring feeder (but sharing the same bus of the substation). In general, DG has to be disconnected from the grid when the fault occurs on the interconnected distribution feeder as soon as possible. However, the faults occured on the neghboring feeder would mistakenly cause the disconnection of the DG. For reliable operation of DG, DG should be sustained at the fault occurred on neighboring distribution feeders. The proposed identification method utilizes the impedance monitored from the DG and examines the coordination of overcurrent relay of the distribution system. This paper describes how the proposed method to identify the faulted feeder and how the method can be utilized.

  • PDF

무선센서네트워크의 지연시간을 고려한 라우팅 알고리즘 (A Routing Algorithm for Low Latency Time in Wireless Sensor Networks)

  • 박재연;박명순
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2010년도 춘계학술발표대회
    • /
    • pp.619-622
    • /
    • 2010
  • 무선센서네트워크는 한정된 에너지 자원을 장기간 사용하기 위하여 주로 에너지 절약을 위한 연구에 중점을 두게 됨으로써 상대적으로 지연시간에 대한 고려는 멀어지게 되었다. 그러나 송배전 선로 등과 같이 일렬로 진행하는 설비 감시에 관한 무선센서네트워크를 구축할 경우에는 일정 구간 단위로 클러스터 헤드의 중계가 반드시 거치게 되므로 클러스터링 자체가 어렵거나 지나치게 많은 전송지연을 유발하며, 한개 노드 장애시 전체 노드에 영향을 주게 되었다. 이를 개선하기 위하여 본 논문에서는 일렬로 진행하는 소규모 클러스터의 효과적 클러스터링 방법과 Every Other Hop(EOH) 중계전송 기법을 사용하여 전송지연시간을 줄이고, Single Point of Failure 문제 해결을 가능하게 하였다.

풍력발전(DFIG)의 고압배전선로의 사고특성 해석에 관한 연구 (A Study on Fault Characteristics of Wind Power in Distribution Feeders)

  • 김소희;김병기;노대석
    • 한국산학기술학회논문지
    • /
    • 제13권3호
    • /
    • pp.1288-1295
    • /
    • 2012
  • 2008년도 지식경제부의 전망에 의하면 신재생에너지전원 중 풍력발전의 보급전망은 2020년 37%, 2030년 42%에 달하고, 2012년부터 시행 예정인 신재생에너지 의무할당제(Renewable Portfolio Standard-RPS)의 도입으로 태양광 및 풍력 등의 신재생에너지가 향후 지속적으로 배전계통에 연계 운용될 것으로 예상된다. 현재 풍력은 배전계통에 전용선로로 연계되어 계통에 미치는 영향은 미미하지만, 3[MW] 이상의 대규모 풍력발전이 일반 배전선로로 확대 운용되면, 풍력발전 연계용 변압기 및 풍력발전기의 %임피던스에 의한 사고전류 변동으로 보호계전기(OCR, OCGR)의 오 부동작을 야기할 수 있다. 따라서 본 논문에서는 대표적인 풍력발전기인 이중여자유도발전기(Double-Fed Induction Generator-DFIG)가 고압 배전선로에 연계되어 운전되는 경우, 3상단락, 2선단락 및 1선지락의 사고특성을 분석하기 위하여, 전력계통 상용소프트웨어인 PSCAD/EMTDC를 이용하여 풍력발전기의 모델링과 시뮬레이션을 수행하고, 대칭좌표법을 통한 이론적인 수치해석의 결과치를 비교/분석하여, 제안한 수법의 유용성을 확인하였다.

비접지 배전계통 지락고장 검출 알고리즘 및 프로그램 개발 (Development of Algorithm and Program for the Ground Fault Detection in Ungrounded Distribution Power System)

  • 박소영;신창훈
    • 한국산학기술학회논문지
    • /
    • 제10권10호
    • /
    • pp.2619-2627
    • /
    • 2009
  • 비접지 배전계통에서 전체고장의 약 70%를 차지하는 지락고장 발생시에는 지락전류가 작아 검출이 어렵지만 고장상태로 전원 공급을 지속할 경우 사고 파급 및 기기 소손을 유발할 가능성이 있기 때문에 지락고장 처리는 매우 중요하다. 본 논문에서는 GPT(접지형 계기용 변압기, Ground Potential Transformer)에서 감지하는 영상전압 신호를 이용하여 고장선로를 검출하고, 비상시 연계선로를 이용하여 정전구역을 복구하기 위해 평상시 개폐기가 열려 있는 상태로 배전선로 사이를 연결하는 상시개방점을 이동하며 각 구간을 차례로 분리하면서 GPT 신호의 사라짐 여부를 감시하여 고장구간을 검출하는 방법을 제안한다. 고장구간 탐색 시 전체 정전이 없고, 고장구간 검출과 건전구간 복구가 동시에 가능하며 다양한 형태의 배전계통 구성에 적용 가능하다는 점에서 효율적이다. 본 논문에서 제안하는 고장처리 방법을 프로그램으로 개발하여 베트남 배전자동화 시범사업에 적용함으로써 알고리즘 및 프로그램의 적정성을 검증하였다.

차량하중을 받는 지중연성관의 거동특성 (Behavior of Underground Flexible Pipes Subject to Vehicle Load)

  • 이대수;상현규;김경열
    • 한국지반공학회논문집
    • /
    • 제18권4호
    • /
    • pp.65-73
    • /
    • 2002
  • 본 연구에서는 지중배전선로를 건설함에 있어 전력케이블용 보호관으로 사용되고 있는 PE파형관의 매설깊이별 작용압력-변형률 특성을 분석하기 위해 전산해석 및 실내 모형토조실험을 수행하였으며, 더불어 고전이론에 의한 해석과 비교 분석하여 지중연성관이 어느 매설깊이에서 안전하고 그 때의 거동특성이 어떤 양상을 보이는지 규명하였다. 실내 모형토조실험에 사용된 토조는 현장조건을 정확히 모사하기 위해 대규모로 제작(350$\times$220$\times$300cm)하였으며, 토조의 크기는 전산해석값을 이용하여 벽체에 의한 응력의 반발이 없도록 치수를 결정하였다. 가압장치로는 최대 25ton까지 압력을 가할 수 있는 Actuator시스템을 이용하였다. 각 해석방법에 적용된 매설형태는 A-1급 도로포장 아래 에 PE파형관이 묻히고, 임계하중으로 DB-24차량이 매설관 상단 중앙에 정차했을 때 관이 받는 작용압력-변형률 특성을 분석하였다. 해석결과, KS-C8455에 명시되어 있는 지중연성관의 허용변형률 기준인 3.5%에 만족하는 매설깊이는 약 40cm 이상인 것으로 판명되었고, 실내 모형토조실험 결과값에 대한 회귀분석을 통해 우리나라 지중배전선로의 현장조건에 잘 적용될 수 있는 지중연성관의 매설깊이에 따른 변형률 상관공식을 제안하였다.