• Title/Summary/Keyword: 배전피뢰기

Search Result 67, Processing Time 0.028 seconds

The electrical properties of in 18kV ZnO surge arrestor with mixed direct and 60Hz Alternating Voltage (중첩전압(직류 +60Hz 교류)에서 18kV 배전용 피뢰기의 전기적 특성)

  • Lee, Bok-Hee;Lee, Seung-Ju;Lee, Su-Bong;Jung, Dong-Cheol;Baek, Young-Hwan
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.291-294
    • /
    • 2007
  • This paper preserts the characteristics of leakage currents flowing through 18 kV zinc oxide (ZnO) surge arrester under the mixed DC and AC voltages. The I-V curves of ZnO surge arrester were measured as a function of the voltage ratio K The I-V curves under the mixed DC and AC voltages lay between the pure DC and AC characteristics, and the cross-over phenomenon in I-V curves was observed at the low current region As a result, the increase of DC component to mixed voltages causes the increase of resistive component of total leakage current th ZnO surge arrester.

  • PDF

A study on analysis of thermal and electrical parameters of the ZnO arrester block (배전용 ZnO 피뢰기 소자의 열적/전기적 파라미터 분석에 관한 연구)

  • Lee, Bok-Hee;Lee, Su-Bong;Lee, Seung-Ju;Jeon, Byung-Wook;Kim, Dong-Sung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.353-356
    • /
    • 2007
  • This paper presents the thermal and electrical characteristics of ZnO arrester blocks under the AC voltages. The leakage currents of ZnO arrester blocks were measured as a function of time. The temperature distributions of ZnO arrester blocks were observed by the forward looking infrared camera The degradation and thermal runaway of ZnO arrester blocks were closely related with the temperature limit of ZnO arrester blocks which decided heat generation and dissipation As a result, the degradation and thermal runaway of ZnO arrester blocks depend on the temperature and leakage current of ZnO arrester blocks.

  • PDF

Analysis of Shielding Effect with Installation Methods of Arresters in Double Circuits Distribution Systems (2회선 배전계통에서 피뢰기 설치방법에 따른 차폐 효과 분석)

  • 정채균;김상국;이종범;정영호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.2
    • /
    • pp.104-110
    • /
    • 2004
  • This paper describes the lightning overvoltage occurred differently according to installation methods of arresters and overhead grounding wire in case of double circuits distribution systems. First, the analysis models are established considering the severe case between upper and lower distribution line, when the direct lightning surge strikes to the overhead grounding wire. The lightning overvoltage is variously analyzed with the change of grounding interval and resistance, arrester installation interval as well as the magnitude of surge using EMTP. After simulation results are compared with the BIL which is now used at field, the authors propose the methods for suitable shielding in domestic distribution systems.

The Installation Technique of Grounding Electrode Conductors for Metal Oxide Distribution Surge Arresters (배전용 피뢰기의 접지도선 설치기법)

  • Lee, B.H.;You, I.S.;Lee, T.R.;Ahn, C.H.;Youn, J.S.;Youn, H.H.;Kim, J.S.;Kim, J.C.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1718-1720
    • /
    • 2001
  • The route of surge arrester connection is very important because bends and kinds of leads increase the impedance to lightning surges and tend to nullify the effectiveness of a grounding electrode conductor. There is a need to know how effective installation of lightning surge arresters is made in order to control voltage and to absorb energy at high lightning currents. The effectiveness of a grounding conductor and bonding for 18[kV] metal oxide distribution line arresters was experimentally investigated with lightning and oscillating impulse voltages.

  • PDF

A Study on the Improvement of ZnO Varistor for Distribution Class Surge Arrester(18kV, 5kA) (배전급 피뢰기(18kV, 5kA)용 산화아연바리스타의 성능향상에 관한 연구)

  • Yoo, Deok-Son;Yoon, Han-Soo;Kim, Suk-Soo;Choi, Yeon-Gyu;Jang, Sung-Do
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.744-746
    • /
    • 2003
  • A ZnO varistor with reference voltage 250V/mm was fabricated through the control of particle size in slurry and the variation of sintering conditions. It was found that to measure the flatness of the V-I characteristic curve in the small-current region and the flatness of the V-I characteristic curve in a large-current region was improved nonlinearity of the fabricated ZnO varistor. According to the IEC 60099-4 was measured the accelerated aging test and high current test of the distribution class surge varistor which is excellent in respect to the property of ZnO varistor.

  • PDF

Degradation properties of ZnO surge arrester due to lightning impulse current (뇌임펄스 전류에 의한 ZnO 배전용 피뢰기의 열화특성)

  • Lee, Seung-Ju;Lee, Bok-Hee;Lee, Su-Bong;Kim, Dong-Soung;Shin, Hee-Kyung;Jung, Dong-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1305-1306
    • /
    • 2008
  • In this work, in order to investigate the effect of lightning impulse currents on ZnO surge arrester. and the deterioration characteristics of ZnO surge arrester, 8/20 [${\mu}s$], 2.5 [kA] impulse currents were applied to the ZnO surge arrester under test. The leakage currents of ZnO surge arrester were measured and ZnO element was analyzed by X-ray photoelectron spectroscopy. As a result, the resistive leakage current of ZnO surge arrester was increased with the injection number of lightning impulse currents.

  • PDF

Electrical properties of 18kV ZnO surge arrester according to the variation of surrounding conditions (외부환경 변화에 따른 배전용 피뢰기의 전기적 특성)

  • Lee, Bok-Hee;Lee, Seung-Ju;Lee, Su-Bong;Jung, Dong-Sung;Shin, Hee-Kyung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.289-292
    • /
    • 2008
  • This paper describes the electrical characteristics of the ZnO surge arrester according to the variation of surrounding conditions. To investigate the characteristics of degraded ZnO surge arrester, 8/20 [${\mu$s], 2.5 [kA] impulse currents were applied to the ZnO surge arrester to be test. To present the effect of the surrounding con야tions, the leakage currents of ZnO surge arrester were measured to the surrounding temperature and wet conditions. As a result, the increase of ambient temperature causes the increase of resistive leakage current of ZnO surge arrester. Also, in the wet test, the outside leakage current through the ZnO surge arrester housing is much larger than the intrinsic leakage current.

  • PDF

Lightning Overvoltage Characteristics in Distribution System with Arrester Application (피뢰기 적용에 따른 다양한 배전계통의 뇌과전압 변화특성)

  • Kim, Sang-Kuk;Jung, Chae-Kyun;Lee, Jong-Beom;Ha, Dong-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.355-357
    • /
    • 2002
  • Distribution lines are spanned on a much large area as compared to transmission lines, and therefore, are more often susceptible to lightning strokes. The selection of the proper value of basic insulation level(BIL), for particular insolation components of distribution structures in specific, is very important. Lightning strikes has current risetimes ranging from 0.1 to several $\mu s$ and can produce transient overvoltages substantially greater than the BIL of many distribution systems in spite of lightning arresters. This paper describes lightning overvoltage of a 22.9kV distribution system due to lightning strike. This study will provide the information on insulation coordination studies to adopt BIL.

  • PDF

Leakage Current Analysis of 18 kV Lighting Arrester (18kV 배전용 피뢰기의 누설전류 분석)

  • Park, J.N.;Lee, Y.H.;Shin, Y.S.;Su, J.M.;Jang, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1906-1908
    • /
    • 2002
  • In general, ZnO lighting arrester are known to exhibit an increases in resistive current with time, the rate of increase being exacerbated with increasing applied voltage. In addition, since the resistive leakage current caused by deterioration of ZnO lighting arrester mainly caused an increase of the third harmonic component, thereby it is possible the arrester degradation diagnosis by measuring the third harmonic component in the total leakage current. So, in this paper, we presents a leakage current measuring and analysis system of 18[kV] ZnO lighting arrester.

  • PDF

Characteristics analysis of field aged distribution surge arresters (경년에 따른 배전용 피뢰기의 열화특성)

  • Cho, Seong-Soo;Kim, Ju-Yong;Kim, Chan-Young;Song, Il-Keun;Park, Jung-Shin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2323-2325
    • /
    • 1999
  • This paper presents characteristics of the aged and new 18kV surge arresters. In order to investigate aging characteristics, we measured total leakage current and resistive leakage current using specially made leakage current measurement system and also investigated $tan{\delta}$ of the arresters and microstructure of the elements. Through the investigation we found that all of the arresters does not aged for 2 years field operation.

  • PDF