• Title/Summary/Keyword: 배연효과

Search Result 61, Processing Time 0.124 seconds

A Study on Reaction Characteristics for NOx Reduction in Flue Gas Denitrification using Plasma (플라즈마 배연탈질에서 NOx 저감에 관한 반응제 특성 연구)

  • Baek, Hyun Chang;Shin, Dae Hyun;Woo, Je Kyung;Kim, Sang Guk;Kim, Dong Chan;Park, Yeong Seong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.12
    • /
    • pp.2247-2254
    • /
    • 2000
  • This study was carried out to investigate the reaction characteristics of NOx with reagents to grope the power consumption rate reduction and NOx removal rate improvement for the non-thermal plasma denitrification process. The experiments were performed using the real flue gas and wire-plate type plasma reactor. and the flow rate of real flue gas is $20Nm^3/hr$. Paraffinic and olefinic hydrocarbons and ammonia were used as reagents. Olefinic hydrocarbon oxidizes NO more actively than paraffinic hydrocarbon under the non-thermal plasma conditions, resulting in the generation of large amount of $NO_2$ and a very small amount of CO. When the initial NOx concentration increases. oxidation rate of NO decreases and the consumption rate of olefinic hydrocarbon increases significantly. On the other hand. $NH_3$ did not promote reduction reaction with NO under non-thermal plasma conditions. however, there was a tendency that the NHa was effective to remove the $NO_2$ oxidized by olefinic hydrocarbon.

  • PDF

Mock-up Test of Improving Super Retarding Concrete to Control of Hydration Heat Crack of Foundation Mat Mass Concrete (기초매트 매스콘크리트의 수화열 균열제어로서 초지연콘크리트 활용에 관한 Mock-up 실험)

  • Lee, Jae-Sam;Bae, Yeoun-Ki;Noh, Sang-Kyun;Kim, Suk-Il;Chung, Sung-Jin;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.777-780
    • /
    • 2008
  • According to the recent tendency that the buildings in the downtown are gradually Manhattanized, the very thick massive concrete is selected as the foundation of architectures. By the way, because this mass concrete cannot be simultaneously pour in a great quantity due to the circumstance at the field, not only the questions on the unification between the concretes pour on the upper layer and the lower layer are presented but also the cracks by the internal force from the difference of hydration exothermic period are occurred, which are pointed out as the problems. Thus, this study performed Mock-up test to apply the hydration heat controlling method of massive concrete for horizontal partition pouring construction to the building sites for the purpose of securing the stability on the cracks by the internal force from the difference of hydration exothermic period on the upper layer and the lower layer of massive concrete and checked the efficiency. As the results of test, in case of setting time difference method by super retarder with 2 layers and 4 layers, the effect that temperature gaps between upper part and lower part were lowered and the possibility of crack occurrence was decreased as the peak time of the heat of hydration became delayed to the latter term could be confirmed.

  • PDF

A Study on Optimization of Spray Type Flue Gas Desulfurization (FGD) System (모사 탈황흡수탑을 이용한 Spray Type 탈황설비 최적운전 방안에 관한 연구)

  • An, Hi-Soo;Park, Seung-Soo;Kim, Ki-Hyoung;Kim, Young-Ho
    • Applied Chemistry for Engineering
    • /
    • v.18 no.1
    • /
    • pp.29-35
    • /
    • 2007
  • Recently, due to narrow margin on design factor of flue gas desulfurization (FGD) systems or aging of systems, some problems such as decrease of $SO_2$ removal efficiency and difficulty on coping with unstable state are arising on FGD systems. On this study, to cope with these problems several methods such as adjustment of reagent pH, inlet $SO_2$ concentration, variation of units of operation pump, installation of liquid distribution ring (LDR) were attempted to increase the $SO_2$ removal using spray type simulated FGD system. Also, sulfite and Al/Fx ion effects on limestone blinding were experimented. When three absorber recirculation pumps were operated, $SO_2$ removal was increased by 12% in comparison with that of two pumps operation. $SO_2$ removal was increased by 2~7% after installation of LDR. Dissolved oxygen increased up to 0.5 ppm and limestone binding effect was alleviated after injection of dibasic acid (DBA) with the concentration of 500 and 1,000 ppm. When $Al^{3+}$ and $F^-$ ions were coexisting, the dissolution rate of limestone was decreased by 20%.

Glass-alumina Composites Prepared by Melt-infiltration: Ⅰ. Effect of Alumina Particle Size (용융침투법으로 제조한 유리-알루미나 복합체: Ⅰ. 알루미나 입도 효과)

  • Lee, Deuk-Yong;Jang, Ju-Woong;Kim, Dae-Joon;Park, Il-Seok;Lee, Jun-Kwang;Lee, Myung-Hyun;Kim, Bae-Yeon
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.9
    • /
    • pp.799-805
    • /
    • 2001
  • Two commercial alumina powders having different particle size of $0.5{\mu}m$ and 3${\mu}$m were presintered at 1120$^{\circ}$C for 2h and then lanthanum aluminosilicate glass was infiltrated at 1100$^{\circ}$C for up to 4h to obtain the densified glass-alumina composites. The effect of alumina particle size on packing factor, microstructure, wetting, porosity and pore size, and mechanical properties of the composite was investigated. The optimum mechanical properties and compaction behavior were observed for the 3${\mu}$m alumina particle dispersed composite. The 3${\mu}$m alumina particle size and distribution for he preform were within 0.1 to 48${\mu}$m and bimodal and random orientation. The strength and the fracture toughness of the composite having 3${\mu}$m alumina particles were 519MPa and $4.5MPa{\cdot}m^{1/2}$, respectively.

  • PDF

The Relationship between Basic Psychological Needs and Postpartum Depression: Focused on the Mediating Effects of Spousal Support and Marital Satisfaction (기본심리욕구와 산후우울의 관계: 배우자지지, 결혼만족도의 매개 효과)

  • Bae, Yeon Wook;Yu, Kum Lan
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.3
    • /
    • pp.518-528
    • /
    • 2021
  • Based on the Self-Determination Theory and previous studies, this study confirmed that basic psychological needs among Self-Determination Theory have an indirect influence on the postpartum depression through mediation of spousal support and marital satisfaction. A sample of 313 mothers who raises her child within a year of giving birth completed a questionnaire survey, and a structural equation model was utilized to analyze the data. Results indicated that both the measurement model, and the hypothesized structural model fit to the data. Meanwhile, when compared with the hypothesized model in which the path between all variables is established, the competitive model excluding the path from spousal support to postpartum depression has no difference in fitness, and was relatively simple and adopted as the final model. In the final model, the link between basic psychological needs and postpartum depression was partially mediated by spousal support and marital satisfaction. In addition, marital satisfaction was found to mediate completely the relationship between spousal support and postpartum depression. Based on the results, it would be helpful to identify the status of basic psychological needs, spouse support, and marriage satisfaction in counseling related to postpartum depression.

An experimental study of smoke extraction efficiency along with ventilation building location in the mad tunnel (도로터널 내 환기소 위치별 방재 효율에 관한 실험적 연구)

  • Rie, Dong-Ho;Kim, Ha-Young;Yoon, Chan-Hoon;Kim, Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.3
    • /
    • pp.215-222
    • /
    • 2010
  • An experimental study was carried out on a reduced scale model tunnel to investigate the efficiency of disaster prevention at underground and ground ventilation equipments for the fire in road tunnels. Based on Froude modeling, the 1/50 scaled model tunnel (20 m long) was manufactured. The vertical shafts that are used in the analysis of efficiency of disaster prevention are the two models that had considered when the real tunnels are designed and the amounts of smoke exhaust are applied the miniature of the real tunnels' smoke exhaust, 560 and $280\;m^3/s$. As the result of analysis, it is the possible the emissions of the entire quantity of CO gas through the vertical shafts. In the ground ventilation equipments, the concentration of CO is discharged 2.23~2,73 ppm smaller than the underground ventilation equipments. And the temperature rise in the ground ventilation equipments is $0.53{\sim}0.94^{\circ}C$ lower than in the underground ventilation equipments because of a cooling effect of the surface of the tunnel wall. As a result of analysis of CO concentration and the temperature rise in the modeling ventilation equipment, the position of ground ventilation equipment is more effective than the underground ventilation equipment in disaster prevention measures.

Effects of an Artificial Habitat Creation of Menyanthes trifoliata L. Using Planting Module (식재모듈을 활용한 조름나물(Menyanthes trifoliata L.) 인공서식지 조성의 효과)

  • Heo, Jinok;Kim, Heung-Tae;Kim, Cheol Min;Bae, Yeon Jae;Kim, Jae Geun
    • Journal of Wetlands Research
    • /
    • v.17 no.1
    • /
    • pp.53-61
    • /
    • 2015
  • Habitat creation for endangered species Menyanthes trifoliata L. using planting module represents a habitat type such as the rhizome grows horizontally to open water at the margin of the lake. The objectives of this mesocosm experiment are habitat creation with easy construction and low management effort, and to investigate the potential of providing a habitat for aquatic macroinvertebrates. Planting modules had three different substrates of bed soil, perlite and K-SOIL (artificial lightweight soil using bottom ash). These modules were established in two different size of the tub($1170{\times}2250{\times}300mm^3$, $900{\times}1360{\times}190mm^3$). According to the monitoring results, number of leaves and coverage of M. trifoliata showed significant difference with substrate and tub size. The number of leaves showed similar growth responses in bed soil (mean 22.979) and K-SOIL (mean 28.042) substrates but growth was poor in perlite substrate (mean 1.667). The number of leaves in the large tub was more than small tub (p=0.015). Similar responses were obtained with the coverage, the length of rhizome and the number of rhizome in M. trifoliata. A total of 21 taxa of aquatic macroinvertebrates including 1,145 individuals was found in the mesocosm. The Shannon diversity index and colonization index in the mesocosm were similar to the previous studies. These results suggest that the experimental mesocosm could provide sufficient habitats for aquatic macroinvertebrates. If planting modules use bed soil or K-SOIL by planting substrate, establish that taking into account open water surfaces for M. trifoliata growth and manage about 30cm of water depth control, then habitat creation for M. trifoilata will be successful.

Changes of Benthic Macroinvertebrate Communities after a Small Dam Removal from the Gyeongan Stream in Gyeonggi-do, Korea (경기도 경안천에서 소형 보(洑)의 철거 이후에 변화된 저서성 대형무척추동물 군집)

  • Kil, Hye-Kyung;Kim, Dong-Gun;Jung, Sang-Woo;Shin, Il-Kwon;Cho, Kang-Hyun;Woo, Hyo-Seop;Bae, Yeon-Jae
    • Korean Journal of Environmental Biology
    • /
    • v.25 no.4
    • /
    • pp.385-393
    • /
    • 2007
  • Benthic macroinvertebrate communities were studied after a small dam removal from the mid-section of the Gyeongan stream in Gyeonggi-do, Korea. Quantitative sampling was conducted at immediately upstream (upper) and downstream (lower) sites from the dam as well as at the site where the dam was located (dam site: middle) using a Surber sampler (50$\times$50 cm, mesh 0.25 mm), four times (November 2004, May 2005, January 2006, and May 2006) after the dam removal. As a result, 46 species of benthic macroinvertebtates, belonged in 35 genera, 27 families, 11 orders, 5 classes, and 4 phyla, were sampled from the stream sites, but the number of species that occurred at each sampling trial was different (ranged 3$\sim$17 spp.) according to the seasons and sites. Approximately one year after the dam removal, the species number has in-creased and taxa composition has changed as the microhabitat became more heterogeneously due to a riffle formation in the upstream site. Chironomid larvae and tubificid worms, which are common in Korean urban streams, were the dominant species, while Hydropsyche kozhantschikovi was the 2nd dominant species at some sampling trials. In general, McNaughton's dominance indices decreased and Shannon species diversity indices increased approximately one year after the dam removal. Compositions of collector-filterers, clingers, and swimmers increased as hydropsychid caddisflies, heptageniid mayflies, and baetid mayflies increased, respectively, in the upstream site. The group pollution index and the ecological score using benthic macroinvertebrates both indicated that water environment has been improved in the upstream site after the dam removal.

Effects of quality grade, trimming, and packaging method on shelf life of king oyster mushrooms (큰느타리의 품질 등급, 손질 및 포장 방법에 따른 유통 수명)

  • Choi, Ji-Weon;Lee, Ji Hyun;Oh, In-Ho;Lim, Sooyeon;Im, Ji-Hoon;Yang, Hae Jo;Choi, Hyunjin;Shin, Sheob;Hong, Yoon Pyo
    • Journal of Mushroom
    • /
    • v.19 no.3
    • /
    • pp.234-245
    • /
    • 2021
  • To extend the shelf life of king oyster mushrooms for export, we investigated the impacts of mushroom quality grade, fruiting body trimming, and packaging method (tray container sealed packaging vs string-tied OPP bag packaging). Quality is divided into two grades: 1st grade, which is mushrooms adapted by lowering the cultivation temperature to 9~11℃, and 2nd grade, mushrooms held at 13~15℃ prior to harvest. Using selected 1st and 2nd grade mushrooms, 3 treatments were carried out to assess effects of trimming and packaging method. Test groups included 1) trimming plus string-tied OPP bag packaging (Cut & OPP), 2) no trimming plus string-tied OPP bag packaging (Uncut & OPP), and 3) trimming plus tray container sealing packaging (Cut & Tray). Gas composition inside the packaging, changes in quality factors, and sensory evaluation for fresh quality were performed over 42 days of 0℃ storage. Overall freshness was best maintained in the following order: Cut & Tray > Cut & OPP > Uncut & OPP for both 1st and 2nd grade mushrooms. The shelf-life of 1st grade mushrooms was about 30 days for Cut & Tray, 28 days for Cut & OPP, and 21 days for Uncut & OPP. The shelf-life of 2nd grade mushrooms was about 22 days for Cut & Tray, 17 ays for Cut & OPP, and 14 days for Uncut & OPP. Factors affecting fresh mushroom quality included browning of cap and stalk, and mushroom decay index. Browning of the lower part of the stalk, with related color change as noted in a* and b* values were the main factors indicating quality deterioration of king oyster mushrooms.

A study on the fire characteristics according to the installation type of large smoke exhaust port in a small cross sectional tunnel fire (소단면 대심도 터널 화재시 대배기구의 설치형태에 따른 화재특성 연구)

  • Choi, Pan-Gyu;Baek, Doo-San;Yoo, Ji-Oh;Kim, Chang-Yong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.201-210
    • /
    • 2019
  • Recently, due to the efforts to mitigate traffic congestion and expansion of space efficiency, the construction of underground roads has been increased in big-scale cities. Since tunnels in the city have a higher chance for a fire leading to a great tragedy during a severe traffic jam than mountain tunnels, it is highly likely that it will be constructed as a tunnel, having a small cross section, for small vehicles. However, if they are constructed as such small-vehicle tunnels, it would be possible to reduce the design fire intensity while the concentration of harmful gases would increase due to a reduction in the small cross sectional area, led by a decrease in the tunnel height. In this study, behaviors of fire smoke by the installation interval and format of large-scale exhaust-gas ports were examined and compared in the analysis of temperatures and CO concentrations of a tunnel and its results were as the following. Although there were no significant differences in the smoke spreading distance between installation intervals, but in this study, 100 m was found to be the most effective installation interval. The smoke exhaustion performance was found to be excellent in the order of $4m{\times}3m$, $6m{\times}2m$, and $3m{\times}2m$ (2 lane) of the smoke spreading distance. Although there was no significant difference in the smoke spreading distance between formats of large-scale exhaust-gas ports, it was found that the smoke spreading distance was larger than other cases when it was $3m{\times}2m$ in the fire growing process. The analysis of smoke spreading distances by the aspect ratio showed that a smoke spreading distance was shorted when its the smoke spreading distance was found to be shorter when its traverse distance was relatively longer than its longitudinal distance.